Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.8 LAccepted-AOC R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | 1 | Accepted-AOC Being lowest bidder. | |
| 2 | 2₹14.8 L+₹2.7 L (22.6%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | 2 | Rejected-Finance Being other than lowest bidder | |
| 3 | 3₹16.1 L+₹4.1 L (33.6%)Rejected-Finance | 3 | Rejected-Finance Being other than lowest bidder | |
| 4 | 4₹17.3 L+₹5.3 L (44.0%)Rejected-Finance H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | 4 | Rejected-Finance Being other than lowest bidder |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
10 Nov 2023, 6:00 pmClosed
GE AF JAMMU
GE AF JAMMU
CA NO GE/AFJ-34/2023-24 REPAIR/MAINTENANCE OF LIFTS AND FIRE FIGHTING EQUIPMENTS INSTALLED AT AF STN JAMMU UNDER GE (AF) JAMMU
2023_MES_615743_2
CA NO GE/AFJ-34/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
JAMMU
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) JAMMU
₹39,000
Yes
16 Jan 2024
20 Oct 2023
13 Nov 2023
20 Oct 2023
10 Nov 2023
27 Oct 2023
Amount
SCHEDULE 'A' PART-I FIRE ALARM/SPRINKLER SYSTEM WORK
Repair/maintenance and complete servicing and greasing of main fire hydrant centifugal pump by disconnecting the pump (make- Kirloskar) from horizontally mounted electrically driven three phase induction motor of capacity 75 HP located at fire fighting room near Auditorium and UGBO in technical area, mounted on a common base frame. Sevicing includes repair to casing, impeller and coupling, replacement of complete sealing of gaskets and greasing of various parts of pump, replacement of damaged bearings if any, motor and pump alignment and installing it in pre existing serviceable condition complete all as specified and directed by Engr-in-Charge
Repair/maintenance and complete servicing and greasing of electrically driven jockey pump by disconnecting the pump (make- Kirloskar) from horizontally mounted electrically driven three phase induction motor of capacity 15 HP located at fire fighting room near Auditorium and UGBO in technical area ,mounted on a common base frame.Sevicing includes repair to casing, impeller and coupling, replacement of damaged bearings if any and complete sealing of gaskets and greasing of various parts of pump alignment and installing it in pre existing serviceable condition complete all as specified and directed by Engr-in-Charge
Repair /maintenance and complete servicing and greasing of fire pump diesel engine driven centrifugal type by disconnecting the pump (make- Kirloskar) from horizontally mounted DG Set of capacity 84 HP located at fire fighting room near Auditorium and UGBO in technical area, mounted on heavy duty mild steel plate. Servicing includes complete repair of shafts, coupling, casing and impeller replacement of damaged bearings if any and installing it in pre existing serviceable condition all as specified by engineer-in-charge.
Servicing of Diesel engine driven pump set capacity 70 KVA/84 HP installed at Fire fighting section at Auditorium and UGBO at AF STN Jammu including carrying out maintenance check alongwith following repairs: (a) Drain out the lubricating oil from sump and refilling after proper cleaning.( Engine oil will be provided by department if required.) (b) Replace engine oil filter catridge with new one. (c) Renew fuel filter catridge with new one. (d) Check tightness of all nuts and bolts. (e) Check adjustment of V belt for driving engine water pump and alternator. (f) Assembling complete old serviceable parts and replacement of old unserviceable parts by new ones as per direction of Engineer-in-Charge. (g) Testing of Disel operated pump set after servicing to entire satisfaction of Engineer-in-Charge. (h) Cleaning of air cleaner filter and renew after period of hrs run as specified by manfacturers manual. Note:- (i). Any minor parts such as screws, washers, split pins, clips etc shall be supplied by the contractor and rate for the same shall be deemed to be included in the unit rate quoted. (ii) The job shall be carried out minimum twice during the contract period or more than two times during the entire contract period if required. (iii) Any parts required to be replaced during servicing of engine shall be deemed to be included in the unit rate quoted all as specified and directed by Engineer-in-charge.Note:-
Complete setting ofconvential/addressable Fire Alarm/sprinkler control panel setting ,repair of unserviceable fire alarm at various locations in station(Map quarters,UGBO,Auditorium,SRE, 3003 SQN etc),checking of control panel for any defect once in a month in prescence of MES Rep,user and contractor and servicing once every month,change of PCBs if required,proper checking of electronic circuit and maintaining its records every month complete, all as specified and as directed by the Engr-in-Charge.
S&F in repair Zone card for conventional /addressable/automatic fire alarm control panel upto 24 zones, complete all as specified and as directed by the Engr-in-Charge.
S&F in repair Power Supply Card for conventional /addressable/automatic fire alarm control panel upto 24 zones, complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair Alarm ACK/Reset Card for conventional /addressable/automatic fire alarm control panel upto 24 zones, complete all as specified and as directed by the Engineer-in-Charge.
Repair/maintenance and complete servicing and greasing of electric motor driven mono block booster pump suitable for 450 LPM discharge @ 35 mtr head located at fire fighting room near Auditorium. Sevicing includes repair to casing, impeller and coupling, replacement of complete sealing of gaskets and greasing of various parts of pump, replacement of damaged bearings if any, motor and pump alignment and reinstalling it in serviceable condition complete all as specified and as directed by the Engineer-in-Charge.
Cleaning of foot valve of pipes in connection to underground sump by emptying the sump well including replacement of minor unserviceable parts like gasket etc of foot valve up to 200 mm dia and refilling the sump well and making it in operational conditioncomplete all as specified and as directed by the Engineer-in-Charge.
Proper cleaning of UG Sump by emptying the sump and cleaning it properly once in six months i.e. two times during the entire contract period and refilling the sump and making it in operational condition complete all as specified and as directed by the Engineer-in-Charge.
Repair/Replacement of Response indicator with in built LED red and green colour by taking down the old U/S one and fixing new one including all fitting complete all as specified and as directed by the Engineer-in-Charge.
Repair of leakage of gate valves/butterfly valves/joints .etc. connected in any size dia pipe if any during operation by proper tightening of nuts and bolts or replacing old washers and gaskets/seal by new one and removing any kind of leakages for proper functioning of sprinkler system as per requirement.
Supply and fixing in replacement of Pressure Switch for Auto operation of fire pumps with fittings including taking down of U/S one and fixing the new one all as specified and directed by Engineer-in-charge .
Supply and fixing of 15mm dia nominal bore quartzoid bulb type sprinklers with temperature rating of 68 deg C any type and approved make including taking down old U/S one and fixing the new one including necessary fittings all in quoted rate as specified and directed by engineer-in-charge.
Supply and fixing in replacement of following items including any necessary change in the previous fitting by taking down the u/s one and fixing the new one and fixing the new one all as specified and directed by engineer-in-charge .Quoted rate includes nuts ,bolts,screws and labour.
MCCB 200 Amps,4 Pole 25 KA electronic release
MCCB 100 Amps, 4 Pole 16 KA electronic release
MCCB 63 Amps,4 Pole 16 KA electronic release
Supply and fixing Air Break 3pole power Contactors MNX-80 (for panel) Including taking down unserviceable contactors. Make: L&T
Supply and fixing of 15 mtr long RRL hose pipe ISI Marked (IS-636-1988 type A) 63 mm dia with SS instantaneous brass male/female end fittings 63 mm dia X15m long all acessories complete including taking down the new one all as specified and directed by engineer in charge.
S&F in repair 18 SWG thick mild steel hose box of size 800 mm x 600 mm x 250 mm, double door with 4 mm thick glass and door frame made of 16 guage MS sheet painted fire red outside and brilliant white inside yard suitable for 2 numbers 63 mm dia hose and 01 number branch pipe, including writing the BOX Sl no with synthetic enamel paint as per sample complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair 63 mm dia gun metal branch pipe, instantenous inlet, male threaded outlet, 15 mm bore nozzle long suitable for fire hydrant, complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair Conventional /addresable type Smoke Detector including base as specified and as directed by the Engineer-in-Charge.
S&F in repair Conventional/addresable type Heat Detector including base complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair Conventional/addresable type Manual Call Point complete all as specified and as directed by the Engineer-in-Charge. (Make-Honeywell/Agni)
S&F in repair fire alarm sounders/sirens /hooter housed in 16 SWG sheet enclosure, electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 500 mtr range suitable for fire alarm control panel complete all as specified and as directed by the Engineer-in-Charge.
M&L for complete removal of old painted surfaces of fire fighting MS pipes and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (using spray gun) including preparation of surfaces for any description/type with arrow mark of pipes (with other color as directed by engr-in-charge) complete all as specified and as directed for the following size of pipes :-
80 to 100 mm bore pipes
150 to 200 mm bore pipes
S&F in repair gun metal double male / female suction hose coupling, 63 mm dia, ISI marked, complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs SS hydrant valve for fire fighting equipment 63 mm bore complete all as specified and as directed by the Engineer-in-Charge.
M&L for complete removal of old painted surfaces of mild steel hose box of size 800 mm x 600 mm x 250 mm, double door (any description) and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (fire red outside and brilliant white inside yard) including preparation of surfaces for any description/type complete all as specified and as directed by the Engineer-in-Charge.
M&L for testing of Wet riser/Down comer system including pipe lines of high rise bldgs of SRE Bldg /Map Qtrs (B-1,B-3,B-4,Offrs S+5) and auditorium and UGBO complete with all connected panel and valves on regular basis incl minor repair of Panel, gauge and other equipment all major items mentioned in above schedule will be measured and paid separately all as specified and directed by Engr-in-Charge. (Note: Testing of fire fire fighting system shall be carried out through reputed agency having minimum 05 Yrs experience in fire fighting works. Necessay supporting documents shall be submitted by bidder for approval of Accepting Officer before commencement of work. All major items mentioned in above schedule will be meaured and paid separetely).
Repair/Maintenance and complete servicing and greasing of 75 HP induction motor of any type and make located at Auditorium and UGBO buildings. (a) Dismantling of motor from electrical connection in presence of MES representative and display all the parts without damage any portion for inspection of Engineer in Charge to ascertain the serviceability of existing parts and assembling the same . (b) Heating, varnishing to stator, rotor with super quality varnish and drying out properly with external heat. (c) Cleaning, washing of bearing and use right quantity of ball bearing grease for bearing. (d) Assembling of motor with old serviceable parts and replacement of unserviceable parts with new as ordered where necessary. (e) Installation of motor by making connections as per existing and testing on load. Note (i) Any parts required to be replaced during servicing, maintenance of motor, pump set, compressor etc to be included in the quoted rates and also labour cost in repair shall be deemed to be included in the quoted rates. (ii) Any minor / major repairs involved to make the motor, pump functional even if notified by the Engineer in Charge shall be carried out by the contractor without any extra cost to the department. (iii) Rewinding of stator of motor (if required and will be measured and paid separately). (iv) Greasing / oiling etc of parts as required shall be done by the contractor without any extra cost to the department.
Repair/Maintenance and complete servicing and greasing of 15 HP induction motor of any type and make located at Auditorium and UGBO connected to jockey pump (a) Dismantling of motor from electrical connection in presence of MES representative and display all the parts without damage any portion for inspection of Engineer in Charge to ascertain the serviceability of existing parts and assembling the same . (b) Heating, varnishing to stator, rotor with super quality varnish and drying out properly with external heat. (c) Cleaning, washing of bearing and use right quantity of ball bearing grease for bearing. (d) Assembling of motor with old serviceable parts and replacement of unserviceable parts with new as ordered where necessary. (e) Installation of motor by making connections as per existing and testing on load. Note (i) Any parts required to be replaced during servicing, maintenance of motor, pump set, compressor etc to be included in the quoted rates and also labour cost in repair shall be deemed to be included in the quoted rates. (ii) Any minor / major repairs involved to make the motor, pump functional even if notified by the Engineer in Charge shall be carried out by the contractor without any extra cost to the department. (iii) Rewinding of stator of motor (if required and will be measured and paid separately). (iv) Greasing / oiling etc of parts as required shall be done by the contractor without any extra cost to the department.
M& L for dismantling induction motor of capacity 75 HP from pump assembly , shifting to workshop and removing unserviceable spares, replacing with new spares such as bush, seal etc of same specifications / type / model. removing burnt copper winding from motor and rewinding with same guage and type of insulation copper conductor winding wires and insulation sheets , applying insulating varnish over the complete winding , drying up by heating , assembling back and testing for proper function including necessary machining works as required , bringing back and reinstalling to the desired platform as specified and as directed by Engineer-in-charge.
M& L for dismantling induction motor of capacity 15 HP from jockey pump assembly , shifting to workshop and removing unserviceable spares, replacing with new spares such as bush, seal etc of same specifications / type / model. removing burnt copper winding from motor and rewinding with same guage and type of insulation copper conductor winding wires and insulation sheets , applying insulating varnish over the complete winding , drying up by heating , assembling back and testing for proper function including necessary machining works as required , bringing back and reinstalling to the desired platform as specified and as directed by Engineer-in-charge.
Repair/Maintenance and complete servicing and greasing of 7.5 HP centrifugal pump of any type and make located at various map buildings. (a) Dismantling of pump from electrical connection in presence of MES representative and display all the parts without damage any portion for inspection of Engineer in Charge to ascertain the serviceability of existing parts and assembling the same . (b) Heating, varnishing to stator, rotor with super quality varnish and drying out properly with external heat. (c) Cleaning, washing of bearing and use right quantity of ball bearing grease for bearing. (d) Assembling of motor with old serviceable parts and replacement of unserviceable parts with new as ordered where necessary. (e) Installation of motor by making connections as per existing and testing on load. Note (i) Any parts required to be replaced during servicing, maintenance of motor, pump set, compressor etc to be included in the quoted rates and also labour cost in repair shall be deemed to be included in the quoted rates. (ii) Any minor / major repairs involved to make the motor, pump functional even if notified by the Engineer in Charge shall be carried out by the contractor without any extra cost to the department. (iii) Rewinding of stator of motor (if required and will be measured and paid separately). (iv) Greasing / oiling etc of parts as required shall be done by the contractor without any extra cost to the department.
Supply and fixing of PVC/ABS nozzles of hose reels With 0.75" or 1" serrated end by taking down the old U/S one and fixing the new one including all essential fitting as specified and directed by engineer in charge.
S&F in repair gun metal female adaptor outlet 63mm dia, suitable for fire hydrant, complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair gun metal male adaptor outlet 63mm dia, suitable for fire hydrant, complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair 30 metre palex hose reel drum complete with pipe and Gm nozzle with roll diameter upto 80 mm of existing make, complete all as specified and as directed by the Engineer-in-Charge.
Complete servicing of fire hydrant valves installed at site for any leakage and unserviceability due to non operation and making it in good operational condition by replacing or repairing washers and kits as specified and directed by enginner in charge.
S&F in repair of wafer type butter fly valve of any size and of existing make at site, complete all as specified and as directed by the Engineer-in-Charge.
S&F Fire alarm panel Battery-Replacement Batteries 12V-24V of existing make as and when required as specified and directed by Engineer-in-charge.
Supply and fixing in repairs lead Maintenance free battery 12 Volts, 150 Ah Make-Exide/ Amaron/Tata in approved make all as directed by Engineer-in-Charge
Supply and fix in repair of Pressure gauge 4"dial 0-14 kgs rating
Supply and fix in repair of Pressure gauge 4"dial 0-21 kgs rating
Supply and fix in repair of Pressure gauge but 8"dial 0-14 kgs rating
Supply and fix in repair of Pressure gauge but t 8"dial 0-21 kgs rating
S&F in repairs PVC Conduit of 25mm dia (medium grade) for fire fighting wiring complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair PVC insulated armoured copper conductor cable size 1.5 sqmm 2 core FRLS, 1100 volts fixed on wall/celling with fixing accessories complete all as specified and as directed by the Engineer-in-Charge.
NOTE- (A)The fire fighting equipments installed near auditorium,UGBO /Map Qtrs (B-1,B-3,B-4,Offrs s+5)and SRE building will be tested for their operation once in a month in prescence of MES Rep,contractor and User and proper documentation will be done which will be the responsibility of the contractor.The contractor will maintain a log sheet for each site as mentioned above and no any extra amount will be paid to the contractor for this by the department. The Contractor shall visit the site before quoting the tender. (B) All fire fighting equipments installed at various location under GE(AF) Jammu will be properly checked for serviceability in emergency condition on monthly basis once in a month throughout the contract period in presence of Engr in charge ,user and contractor.No extra amount will be paid to the contractor for this serviceability check.
SCHEDULE 'A' PART-II LIFT WORK
Supply,installing and fixing of following items in 13 passengers lift in Map building block B-4 for unit 2-10-S12067 and making it in operational condition as specified and directed by engineer-in-charge (a) Track roller W Ball bearing Dia 48(Qty 04) (b) PCB MCU Motherboard Tic V (Qty-01) (c) Spp Uspd 1 Din Rail Type(Qty-01)
Supply only of maintenance free batteries of 12 V 18 AH for automatic rescue device (ARD) suitable for 8 to 13 passenger lift installed at map qtrs Officers and ORs at vahu vihar and domestic area by taking down the old U/S one and properly fixing the new one as specified and directed by engineer-in-charge Make- EXIDE/AMARON/AMAR RAJA
Supply only of elevator cabin LED Ceiling COB spot recessed down light fittings,(circular/square type )with driver complete all as specified and directed.Make-As per existing OEM of above lift(Havells,Panasonic.etc)
Supply only of blower/fan for elevator 8 &13 passenger lift installed at map qtrs Officers and ORs at vahu vihar and domestic area by taking down the old U/S one and properly fixing the new one as specified and directed by engineer-in-charge.(Brand-Cronax)
Supply only the following item of lift for making the lift serviceable completely to the entire satisfaction of the Engineer in charge.
Door beading(as per sample)
Cabin fan for car cabin, single phase, wall mounted, 300mm sweep, 240 volts ISI marked with grill complete (as per sample),
Car light fittings (as per sample),
Car push button (ISI Marked) (as per sample)
Buzzer (as per sample)
Automatic door driver unit with motor on car top with VVF01 - 1HP capacity complete (as per sample)
Alarm Device (as per sample)
Car Flooring as per sample suitable for Lifts
Preventive maintenance/Repair & replacement of certain U/S item item of 02 Nos of lifts for 08 passengers and 13 passengers for Bldg B-03 Map Qtr under GE AF Jammu Repair/maintenacne of lifts including carrying out periodical 24x7 FOR 11 months call back services of fully automatic electrical lift with power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes,door, PCB Controller cards,car door sills, landing door sills, door locks, control cards, and its contacts, hall push buttons and its spares, connector/links, welding of crack/broken and MS parts, Landing operating Panel of any size and capacity, repairs /maint of u/s damaged door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, ARD system and all connected accessories, necessary wiring of hall push button assembly, repair/ maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen button glass, Intercom, alarm/hooters, Maintenance of damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for illuminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement for safe operation of lifts , fixing of loose rail bracket with necessary masonry work ,cabin, minor repair of cabin light and minor repair of cabin fan, ensure safe and smooth functioning of lift and complete maint of car top, including repair/maint of motor, binding of loose wire at control panel and dewatering of lift wells in case of any emergency arise all as directed by Engineer-in-Charge. for the 8 Passanger & 13 Passenger Lift operating for G+7 floors at MAP B-3 Block at AF Jammu.
Preventive maintenance/Repair & replacement of certain U/S item item of 02 Nos of lifts for 08 passengers and 13 passengers for Bldg B-04 Map Qtr under GE AF Jammu Repair/maintenacne of lifts including carrying out periodical 24x7 FOR 11 months call back services of fully automatic electrical lift with power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes,door, PCB Controller cards,car door sills, landing door sills, door locks, control cards, and its contacts, hall push buttons and its spares, connector/links, welding of crack/broken and MS parts, Landing operating Panel of any size and capacity, repairs /maint of u/s damaged door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, ARD system and all connected accessories, necessary wiring of hall push button assembly, repair/ maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen button glass, Intercom, alarm/hooters, Maintenance of damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for illuminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement for safe operation of lifts , fixing of loose rail bracket with necessary masonry work ,cabin, minor repair of cabin light and minor repair of cabin fan, ensure safe and smooth functioning of lift and complete maint of car top, including repair/maint of motor, binding of loose wire at control panel and dewatering of lift wells in case of any emergency arise all as directed by Engineer-in-Charge. for the 8 Passanger & 13 Passenger Lift operating for G+7 floors at MAP B-4 Block at AF Jammu.
Preventive maintenance/Repair & replacement of certain U/S item of 01 Nos of lifts for 13 passengers for Bldg Officer Map Qtr under GE AF Jammu Repair/maintenacne of lifts including carrying out periodical 24x7 for 11 months call back services of fully automatic electrical lift with power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes,door, PCB Controller cards,car door sills, landing door sills, door locks, control cards, and its contacts, hall push buttons and its spares, connector/links, welding of crack/broken and MS parts, Landing operating Panel of any size and capacity, repairs /maint of u/s damaged door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, ARD system and all connected accessories, necessary wiring of hall push button assembly, repair/ maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen button glass, Intercom, alarm/hooters, Maintenance of damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for illuminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement for safe operation of lifts , fixing of loose rail bracket with necessary masonry work ,cabin, minor repair of cabin light and minor repair of cabin fan, ensure safe and smooth functioning of lift and complete maint of car top, including repair/maint of motor, binding of loose wire at control panel and dewatering of lift wells in case of any emergency arise all as directed by Engineer-in-Charge. for the 13 Passenger Lift operating for A+5 floors at MAP Officers Block at AF Jammu.
Note:- (A)The DLP of this item is getting over on 30 Jan 2024.so the contractor will resposible to maintain he operation of this item with authorised OEM from 31 Jan 2024 onward till entire contract period. (B) The lifts shall be maintained by TK Elevator India Private Limited(formerly known as thyssenkrupp Elevator India Private Limited) For item No.2.14,2.15&2.16
Repair/maintenacne of lifts including carrying out periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes,door cards,car door sills, landing door sills, door locks, control cards, and its contacts, hall push buttons and its spares, connector/links, welding of crack/broken and MS parts, Landing operating Panel of any size and capacity, repairs /maint of u/s damaged door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, and all connected accessories, necessary wiring of hall push button assembly, repair/ maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen button glass, Intercom, alarm/hooters, Maintenance of damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for illuminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement for safe operation of lifts , fixing of loose rail bracket with necessary masonry work ,cabin, minor repair of cabin light and minor repair of cabin fan, ensure safe and smooth functioning of lift and complete maint of car top, including repair/maint of
motor, binding of loose wire at control panel and rust painting at car top and door and allied parts with testing, two coats of Painting of Gear motor, all MS channels and Control panels using spray gun complete, dewatering of lift wells in case of any emergency arise all as directed by Engineer-in-Charge. for the 8Passanger Lift operating for G+4 floors at SRE Bldg at AF Jammu
Note :- (a) The above service shall be made on monthly basis and as and when any breakdown arise (b) The Contractor shall be porvide authorised service personnel of Johnson company as and when required in case of any emergency occured at any time included odd hrs/sunday/Holiday and cost to this effect shall be deemed to included in quoted rates. (c) The Contractor shall visit the site before quoting the tender. (d) Cost of minor spare parts / routine material required for above mentioned maintenance is deemed to be included in the quoted rate . No additional cost of spares is admissible for the above maintenance. Decision of the Accepting Officer shall be final & binding regarding minor spares /routine material (e) All Items required to be replaced/renewed during comprehensive maintenance period shall be supplied by OEM and quoted rate shall be deemed to be inclusive of price of these items except car enclosure, hoist way enclosure, car and landing door panel, surrounds, frames and sill, all finishes, landing door, wall panel, light diffuser, cabin fans, blower fans, cabin handrails, mirror, glass sides and hoist way, special display and lift shaft lighting, replacements of batteries, light bulbs in the shaft and machine room, treatment of surfaces of component as e.g. painting and replacements of decorative elements, cleaning of building, car and door.
(f) Make and model of part to be replaced shall be as existing at site or as per OEM recommendation. (g) The cost of transportation and other necessary equipments shall be arranged/brought by contractor in this effect. (h) The contractor shall visit the site before quotating the tender. (j) All fire fighting equipments insatalled at various locations under GE AF Jammu will be properly checked for seviceability in emergency condition on monthly basis once in a month throughout the contract period in prescence of engineer-in-charge,user and contractor.No extra amount will be paid to the contractor for this serviceability check. B) All fire fighting equipments installed at various location under GE(AF) Jammu will be properly checked for serviceability in emergency condition on monthly basis once in a month throughout the contract period in presence of Engr in charge ,user and contractor.No extra amount will be paid to the contractor for this serviceability check.
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
ANIKET TRADERS
M/S VIDYA ENTERPRISES
M/s Shakti Electric Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .