Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder |
Tender Value
₹34.5 L
EMD Value
₹69,100
Closing Date
22 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Kapurthala
GE Kapurthala
Provn of one Vocational Lab of PM SHRI KV at New Mil Stn Kapurthala under GE Kapurthala.
2025_MES_699262_2
GE KPT- /2024-25
Open Tender
Civil Works
Item Rate
180 days
Area under GE Kapurthala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Kapurthala
₹69,100
Yes
13 Jun 2025
1 Apr 2025
29 Apr 2025
1 Apr 2025
22 Apr 2025
8 Apr 2025
Amount
Excavating in trenches not exc 1.5 m wide and not exc 1.5m deep and area not exceeding 10 sqm on plan for foundation/foundation of poles/stays/laying of cable etc and getting out in soft/loose soil complete all as specified and as directed by Engineer-in- Charge. Breakdown of Qty :- Bldg Works -120 Cum Electrical Works - 37.00 Cum
M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregate in foundation complete all as specefied and directed by Engr-in-Charge.
M&L for formwork to sides of concrete foundations, footings, bases of columns, plinth beam and similar work for fair finished surface complete all as specefied and directed by Engr-in-Charge.
M&L for formwork to sides of pillars, posts, columns etc in square, rectangular and similar work for fair finished surface complete all as specefied and directed by Engr-in-Charge.
M &L, for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping) complete all as specefied and directed by Engr-in-Charge.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, splays between floors and beams, etc complete all as specefied and directed by Engr-in-Charge.
M & L for Reinforced cement concrete (design mix) M-25 (20mm graded stone aggregates) as in foundation, including rafts, plinth beams, footings etc complete all as specefied and directed by Engr-in-Charge.
M&L for Reinforced cement concrete (design Mix) M-25 (20mm graded stone aggregates) as in lintels & roof beam complete all as specefied and directed by Engr-in-Charge.
M & L for Reinforced cement concrete (design mix) M-25 ( 20mm graded stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specefied and directed by Engr-in-Charge.
M&L for Reinforced cement concrete (design Mix) M-25 (20mm graded stone aggregates) as in slabs complete all as specefied and directed by Engr-in-Charge.
Supply and fix TMT bars 10mm dia and over, cut to length, bent to shape required, including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specefied and directed by Engr-in-Charge.
Supply and fix TMT bars 6 to 8 mm dia and over as in stirrups, cut to length, bent to shape required, including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-Charge.
M&L for moorum filling in floors laid in layers not exc. 15cm thick spread, levelled and rammed including watering complete all as specefied and directed by Engr-in-Charge. Note : Moorum for filling shall be brought from outside the defence Land and shall be approved from GE before filling)
M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregates , 100mm thick as in sub base complete all as specified and directed by Eng-in-Charge.
M& L for hard core of gauge not exc 63mm deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface of 100mm thick with broken/stone/bouldres complete all as specified and directed by Eng-in-Charge.
M&L for Brick work with sub class 'B' Bricks burnt bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:4 complete all as specified and directed by Eng-in-Charge.
Material and labour for brick work with fly ash bricks (old size bricks) straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick on fair faces or other than fair faces of brick work in CM 1:4 with WPC finished even & fair without using extra cement complete all specified and directed by Engineer-in-charge . Note - WPC shall be measured and paid seprately.
M&L for 10mm thick rendering in CM 1:3 on brick work or concrete surfaces finished even and smooth without using extra cement in ceiling complete all as specified and as directed by Engr-in-Charge.
M&L for rendering 15mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
Material & Labour for preparation of new plastered surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including 1mm thick plaster of paris putty over plastered surface to make it smooth complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new plasterd surfacs of walls, distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50gms/litre, of approved manufacturer, of required shade and colour complete as per manufacturer's specification with Two or more coats on new plastered surface over a coat of 2mm thick plaster of paris putty to make the surface smooth including rubbing with sand paper of requisite micron complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distermper over a coat 3mm thick wall care putty over a coat of appropriate primer complete all as specified and as directed by Engr-in-Charge.
M & L for 75mm thick PCC (1:3:6) type C-1 (using 20mm graded stone aggregates) as in plinth protection and finishing the surface even and fair without using extra cement complete all as specified and directed by Engr-in-Charge.
Supply only integral water proofing compound complete all as specified and as directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm thick each complete all as specified complete all as specified and directed by Eng-In-Charge. Breakdown of Qty :- Bldg Works -62.00 Cum Electrical Works - 19.00 Cum
Removing of surplus excavated soil to a distance not exc 50m away and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Eng-In-Charge. Breakdown of Qty :- Bldg Works -52.00 Cum Electrical Works - 18.00 Cum
Supply and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete all as specified and as directed by Engr-in-Charge.
S&F framed work Fe 410-W(Gde-E-250) Quality-A as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering.Doors etc. to be prepared for hanging or sliding with and incl hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete all as specified and as directed by Engr-in-Charge.
S&F Plain framed, panelled shutter 35 mm thick of 2nd class hardwood (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed by Engr-in-Charge.
S&F GI tubing 15mm dia medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and as directed by Engr-in-Charge.
S&F kitchen sink with drain board made of stainless steel 1mm thick sheet with plugs, washers and wastes including bedding in cement mortar including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm complete all as specified and as directed by Engr-in-Charge.
S & F 300mm long aluminium alloy, anodized sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolt and sliding bolt of extruded section complete all as specified and as directed by Engr-in-Charge.
S & F 200mm aluminium anodized barrel tower bolt of extruded section and fixed complete all as specified and as directed by Engr-in-Charge.
S&F 200mm long extruded aluminium alloys handles frabicated type anodized complete all as specified and as directed by Engr-in-Charge.
M&L for preparation of new wooden surface exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Eng-In-Charge
M & L for preparation of new painted steel surfaces of any description over 10 cm in width of girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge.
M&L for glazed ceramic coloured tiles of approved pattern in vertical surface 450 x350 x 7mm thick set and jointed in neat cement slurry pointed in white or colour cement to match the shade of times, with 10 mm thick cement screed bed (1:4) complete all as specified and as directed by Engr-in-Charge.
M&L for for Non-skid Ceramic coloured tiles of approved pattern 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the sahde of tile including 15 mm thick cement screed bed 1:6 complete all as specified and as directed by Engr-in-Charge.
Supply and fixing 15mm dia bib taps, cast copper alloy with crutch or butter fly handles, screwes down, screwes for iron pipe complete all as specified and as directed by Engr-in-Charge.
Supply and fixing 20mm dia stop valves cast copper alloy, screwed down, high pressure with crutch or butter fly handles, screwed both ends for iron pipe complete all as specified and as directed by Engr-in-Charge.
S&F PVC (SWR) floor trap 110mm, setting and jointing with solvent cement complete all as specified and directed by Engr-in-Charge.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or floor complete all as specified and as directed by Engr-in-Charge.
S&F for 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to walls complete all as specified and directed by Engr-in-Charge.
S&F 110mm dia PVC (SWR) bends complete all as specified and as directed by Engr-in-Charge.
S&F PVC (SWR) junction (single ‘T’) with oval access door for 110mm dia pipe complete all as specified and as directed by Engr-in-Charge.
Supply and fixing rotational moulded polythelene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position as per SSR Part-1 of 500 ltrs capacity including fittings complete all as specified and as directed by Engineer-in-Charge.
S&F gunmatal globe and gate valve with iron welded hand secrewed both and for iron pipe 20mm fixed complete all as specified and directed by Engr-in-Charge. Breakdown of Qty :- Bldg Works -1.00 Each Electrical Works - 1.00 Each
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engr-in-Charge.
M& L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed by Engr-in-Charge.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed by Engr-in-Charge.
M&L for treating the soil under plinth protection at the rate of 5 litres of mulsion per square metre of surface area complete all as specified and directed by Engr-in-Charge.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed by Engr-in-Charge.
M&L for rendering 10mm thick cement mortar 1:3 on concrete surface even and smooth with waterproofing compound as directed by Engr-in-Charge
Preparation of newly plastered surface making surface completely dry and applying a coat of bitumen primer confirming to IS :3384-1965 @ 0.40kg/sqm and after drying of primer apply APP modified water proofing membrane with non woven polyster reinforcement 3mm thick superior multipolymericweighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers laid with torching application to the surface over a coat of hot blown bitumen 85/25 @1.20 Kg/Sqm complete and sealing the side as well as end laps (overlaps should not be less than 10 cm) complete all as specified and directed by Engineer-in-charge.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in loose / soft soil complete all as specified and directed by Engr-in-Charge.
Removal of excavated material to a distance exceeding 250m and but not exceeding 500m complete all as specified and directed by Engr-in-Charge.
M&L, for Machine pressed precast concrete interlocking paver block of approved shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed by Engr-in-Charge.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-Charge.
M&L for continuous brick edging with width equal to the depth of the brick, laid dry, on edge complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete Type E2, 1:5:10 (40 mm graded stone aggregates) as in foundations, filling and mass concrete complete all as specified and directed by Engr-in-Charge.
Material and labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC (FRLS) insulated cable in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 1.5 Sqmm insulated un-sheathed PVC insulated copper conductor common earth and connecting to earth dolly for :-
(a) One light point controlled by one, one way switch complete all as specified and directed by Engr-in-Charge.
(b) One fan point controlled by one, one way switch complete all as specified and directed by Engr-in-Charge.
(c) One socket outlet 3 Pin, 5 Amp on independent board complete all as specified and directed by Engr-in-Charge.
(d) One socket outlet 3 Pin, 5 Amp on same board complete all as specified and directed by Engr-in-Charge.
M&L for point wiring with 2.50 Sq mm single core multi-stranded copper conductor PVC (FRLS) insulated, unsheathed cable 1100 volt grade in PVC concealed conduit of size 19/20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 1.50 Sq mm single core, multi-stranded copper conductor, PVC insulated, unsheathed cable for common earth and connecting for earth dolly for 5 pin, 15 Amp socket outlet on Independent board.
S&F switch piano flush type single pole one way 5 Amp (ISI Marked) complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush type single pole one way 15 Amp (ISI Marked) complete all as specified and directed by Engr-in-Charge.
S&F socket out let 2 in 1, 3 pin 5 Amp flush type (ISI Marked) complete all as specified and directed by Engr-in-Charge.
S&F socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked) complete all as specified and directed by Engr-in-Charge.
M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked) complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of 20 watt 4 ft long LED Batten housing made of extruded alluminium with milky white diffuser and inbuilt electronic driver system lumen output should be at least 1800 lumen with a CCT of 6000 K, power factor should be greater than 0.9 with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 complete all as specified and directed by Engr-in-Charge.
S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including LED lamp 09W complete all as specified and directed by Engr-in-Charge.
Supply and fixing factory made sheet metal enclosure double door distribution board class IP-43 with 200 Amp rated copper bus bar 415 volts 4 way Triple pole and neutral link complete all as specified and directed by Engr-in-Charge.
Supply & fix following type/rating MCB’s including necessary connection as under :-
(a) S & F of MCB, 10 to 32 Amp, SP, 240 Volt complete all as specified and directed by Engr-in-Charge.
(b) S&F of MCB, TPN/FP 40 to 100 AMP complete all as specified and directed by Engr-in-Charge.
M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper condutor, multi stranded cable of size 6.00 Sqmm 1100 volts grade drawn PVC concealed conduit of size 19/20 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good etc including one run of 6.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Three run of 6.00 Sqmm cable and one run of PVC Conduit shall be measured & paid as one unit.)
S&F Exhaust fans of 230 Volt 300 mm sweep ventilator DB bouble ball bearing heavy duty motor, metal blade with protection steel bird guard and roubst complete including M&L for providing/cutting the round hole of required size in wall finishing the same supply and grounting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/.0076 copper cable rubber insulated from ceiling rose to exhaust fan motor and writing MES No. with black synthetic enamel paint 2.0 cm high complete all as specified and directed by Engr-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engr-in-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as specified and directed by Engr-in-Charge.
Supplying, laying, jointing and testing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 vols grade cross sectional area 16 Sqmm 4 core laid in trences, in floor, in duct, through pipes or along the pole including taking down old one complete all as specified and directed by Engr-in-Charge.
Material and labour for sand cushioning to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable complete all as specified and directed. Note :- For payment purpose 18cm punned down thickness shall be considered.
Material and labour for brick protection using old size sub class ‘B’ bricks, laid flat, dry adjacent to each other laid length wise perpendicular to the axis of cable complete all as specified and directed by Engr-in-Charge.
Supply and fixing GI tubing medium grade 20 mm bore in any length with all fitting laid in trench and connecting up with water supply main complete all as specified and directed by Engr-in-Charge.
Supply and fixing GI tubing medium grade 25 mm bore in any length with all fitting laid in trench and connecting up with water supply main complete all as specified and directed by Engr-in-Charge.
Supply and fixing of gun metal globe or gate valve with iron wheel head screwed both ends suitable for galvanised pipe 25 mm bore complete all as specified and directed by Engr-in-Charge.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .