Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹1.9 CrAWARDED | ₹1.9 Cr | AWARDED |
Tender Value
₹1.9 Cr
EMD Value
₹2.9 L
Closing Date
23 Sept 2025, 9:30 pmClosed
Karnataka Urban Water Supply and Drainage Board
Operation and Maintenance of Civil works of water supply systems of Channapatna City up to End User point and for enroute villages upto tapping point and pumphouse, pumping machinery, electrical installation and allied accessories of Electromechanical works at T K Halli WTP, Guruvinapura IPS and Channapatna IPS for providing water supply facilities to Channapatna city
KUWSDB/2025-26/WS/WORK_INDENT396
KUWSDB/2025-26/WS/WORK_INDENT396
Open
Water supply/sewage lines
Two Tender Document System(Two Cover)
KUWSDB Chief Engineer Revenue zone Bengaluru
₹4,870
₹2.9 L
9 Sept 2025
9 Sept 2025
24 Sept 2025
15 Sept 2025
16 Sept 2025
Operation and Maintenance of Civil works of water supply systems of Channapatna City up to End User point and for enroute villages upto tapping point and pumphouse, pumping machinery, electrical installation and allied accessories of Electromechanical works at T K Halli WTP, Guruvinapura IPS and Channapatna IPS for providing water supply facilities to Channapatna city
I - Operation and Maintenance of Civil Works of bulk & distribution from T.K.Halli to Channapatna city upto consumer point
I PART A - FIXED COST
Management Contract for Operation and Maintenance of w...
do 2 Nos Operators (For Bulk Maintainance ) - Rural area (Per person per month) including reserved/ weekly off adjustment
do 5 Nos Helper / unskilled workers (For Bulk Maintainance) (In rural area) (Per person per month) including reserved/ weekly off adjustment ( 4 Nos Helpers + 1 No Enroute )
do 2 Nos Security for WTP at TK halli and IPS Guruvinapura (For Bulk Maintainance) (In rural area) (Per person per month) including reserved/ weekly off adjustment
do 9 Nos of Clerks/meter readers (for distribution System) Urban area (Per person per month) including reserved/ weekly off adjustment
do 11 Nos of Helpers( for distribution System ) Urban area (Per person per month) including reserved/ weekly off adjustment
do 2 Nos of Helpers( for distribution System ) Urban area (Per person per month) including reserved/ weekly off adjustment ( 1 No Security/WM+1 No IPS at Channapatna & office premises )
do 12 Nos of Valveman ( for distribution System ) Urban area (Per person per month) including reserved/ weekly off adjustment
Service Charge for code 01 to code 08 @ 2%
I PART B - GENERAL ITEMS - Supply of Bleaching Powder for washing/Chlorination purpose at all Pumping stations confirming to relevant IS and specifications with all applicable taxes, transportation, l...
Supply of Liquified Chlorine Gas Cylinders for WTP at T.K.Halli and IPS at Channapatna confirming to relevant IS and specifications with all applicable taxes, transportation, loading and unloading, st...
Supply of PAC Powder at T K Hally confirming to relevant IS and specifications with all applicable taxes, transportation, loading and unloading,stacking as per directions of EIC.
I PART C Event Oriented works (Civil) - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to lin...
do PVC pipes 75mm dia., 6 kg/sqcm & class 3
do PVC pipes 90mm dia., 6 kg/sqcm & class 3
do PVC pipes 110mm dia., 6 kg/sqcm & class 3
do PVC pipes 140mm dia., 6 kg/sqcm & class 3
do PVC pipes 160mm dia., 6 kg/sqcm & class 3
do PVC pipes 200mm dia., 6 kg/sqcm & class 3
Supply of DI pipes conforming to IS 8329:2000 with latest amendments and conveying to work site from Board stores, rolling and lowering into trenches, laying true to line and level and perfect linking...
do For 150 mm dia. DI pipe K-7 Class
do For 200 mm dia. DI pipe K-7 Class
do For 250 mm dia. DI pipe K-7 Class
Supply of valves conforming to relevant ISS with latest amendments as detailed below including loading, unloading, stacking using labours from Part A with all lead and lift, transportation etc. comple...
do For 100mm dia Suilce Valve of PN - 1.0
do For 150mm dia Suilce Valve of PN - 1.0
do For 200mm dia Suilce Valve of PN - 1.0
do For 250mm dia Suilce Valve of PN - 1.0
Supply of the following DI specials confirming to relevent 8329-2000 with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
- All D.I. Flanged...
do All D.I. Flanged Socketed 150.00 mm
do All D.I. Flanged Socketed 200.00 mm
do All D.I. Flanged Socketed 250.00 mm
do All D.I. Flanged Spigot 100.00 mm
do All D.I. Flanged Spigot 150.00 mm
do All D.I. Flanged Spigot 200.00 mm
do All D.I. Flanged Spigot 250.00 mm
do MJ COLLAR 100.00 mm
do MJ COLLAR 150.00 mm
do MJ COLLAR 200.00 mm
do MJ COLLAR 250.00 mm
Supply of the PVC specials confirming to relevent IS codes with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
- 75 mm PVC Repair Collar
do 90mm PVC Repair Collar
do 110mm PVC Repair Collar
do 160mm PVC Repair Collar
do 200mm PVC Repair Collar
do 250mm PVC Repair Collar
do 3/4 inch PVC Collar
do 63 mm PVC Collar
do 75 mm PVC Collar
do 90mm dia PVC couplers/collar
do 110mm dia PVC couplers/collar
do 160mm dia PVC couplers/collar
do 200mm dia PVC couplers/collar
do 63 mm dia PVC Tee
do 75 mm dia PVC Tee
do 90 mm dia PVC Tee
do 110 mm dia PVC Tee
do 160 mm dia PVC Tee
do 160 mm X 110 mm PVC Reducer Tee
do 90 mm dia PVC BEND
do 110 mm dia PVC BEND
do 160 mm dia PVC BEND
do 3/4" dia PVC Elbows
do 63 mm dia PVC Elbows
do 75 mm dia PVC Elbows
do 90 mm dia PVC Elbows
do 110 mm dia PVC Elbows
do 160 mm dia PVC Elbows
do 200 mm dia PVC Elbows
do 90 mm X 63 mm PVC Reducer Collar
do 110 mm X 90 mm PVC Reducer Collar
do 140 mm X 110 mm PVC Reducer Collar
do 160 mm X 110 mm PVC Reducer Collar
do 160 mm X 90 mm PVC Reducer Collar
do 200 mm X 160 mm PVC Reducer Collar
do 110mm dia TP
do 160mm dia TP
do 200mm dia TP
do 3/4 inch PVC end cap
do 90mm dia PVC Endcap
do 110mm dia PVC Endcap
do 160mm dia PVC Endcap
do 200mm dia PVC Endcap
do 63mm dia PVC Ball Valve
do 90mm dia PVC Ball Valve
do 90 x 75 mm dia Reducer bush
do 110 x 90 mm dia Reducer bush
do 90x63 mm dia MTA
do 63 mm dia FTA
do 90 x 63 mm dia FTA
Carrying CI valve repairs with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
- 80 mm dia checknut repair
do 80mm dia Valve rod and Checknut repair
do 100mm dia Valve rod and Checknut repair
do 150mm dia Valve rod & Checknut repair
do 200mm dia Valve rod and Checknut repair
do 250mm dia Valve rod and Checknut repair
Supply of cement
do concrete breaker
do Solvent Cement
do Rubber Insertion
do Gland packing (10/12mm)
do 90 mm dia MS Flange
do 110 mm dia MS Flange
do Double side Blade
do Supply Water through Tanker (6 KL)
Water quality test charges as per KSPCB norms
Dewatering the sewage / storm water by using reqired HP submersible pump for the diversion of storm / sewage during the execution of workwith all lead and lift, transportation with all lead and lift, ...
Road Reinstatement of Asphalt /Concrete roads after leak attending with earth work excavation of compacted soil depositing on bank with all lead and lifts including danger lighting and barricading. Pr...
Supply and delivery of Leak Arresting Flexible SS Clamps of Wrap Around Single Section type upto 500 mm diameter and Maxi Range double section type beyond 500 mm OD of all rigid pipe sections. The Cla...
Providing Barricade with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
Supply of Rubber hand gloves
Providing Boots set
Providing Rain coat
Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following oper...
The work of attending leakage in 200mm dia scour distance piece, the work includes dewatering of scour valve chamber, identifying the leakage spot in 200 mm dia distance piece, grinding of pipe & weld...
The work of attending leakage in 200mm dia Air Valve distance piece, the work includes dewatering of scour valve chamber, dismantling the scour valve, removing the distance piece from 600mm dia Rising...
The work of attending leakage in 610mm dia MS pipe rising main, the work includes, earthwork excavation by JCB, dewatering of excavated trench, identifying the leakage in 610mm dia MS pipe rising main...
The work of attending leakage in 600mm dia PSC pipe circumferential crack, the work includes, earthwork excavation by JCB, dewatering of excavated trench, identifying the leakage in 600mm dia PSC pipe...
For the work Plugging/repairing of leakages in 600mm dia PSC pipe line either at joint or in the barrel without removing the pipe and leakages repairing with existing strap/step collar, led wool, hemp...
For the work of arresting major water leakage in 610mm existing M.S pipe cutting and joint welding and supporting and necessary realignment and necessary earth work using JCB, Crane, DG set, Dewater...
Replacement of damaged 200/150mm dia air valve all along rising main pipeline from T.K.Halli to Guruvinapura. Repair and servicing air valve using JCB, DG set, dewatering pump, cutting machine includi...
II. Operation and Maintenance of pumphouse, pumping mechinery, electrical instalation and allied accessories of Electromechanical works T K Halli WTP, Guruvinapura IPS and Channapatna IPS of water sup...
do 6 Nos Helpers / unskilled workers (For Bulk Maintainance) - Rural area (Per person per month) including reserved / weekly off adjustment.
do 2 Nos Operators (For Bulk Maintainance) - Urban area (Per person per month) including reserved / weekly off adjustment.
do 2 Nos of Helper / unskilled / watchman (For Bulk Maintainance) - Urban Area (Per person per month) including reserved / weekly off adjustment.
Service Charge for code 130 to code 133 @ 2%
Provision towards required consumable like grease, gand packing, cotton waste, SA-10 grade oil, bearing for motor and pump etc and for minor repairs replacement of Electrical consumables at all pumpin...
II PART B 'Monthly Manitenance
'Raw water pumping station at T K Halli
1. Check free movement of the gland of the stuffing box; check gland packing and replace if necessary.
2. Clean and apply oil t...
Pure water pumping station at T K Halli
1. Check free movement of the gland of the stuffing box; check gland packing and replace if necessary.
2. Clean and apply oil to the gland bolts.
3. Check condi...
IPS at Guruvinapura (per month)
1. Check free movement of the gland of the stuffing box; check gland packing and replace if necessary.
2. Clean and apply oil to the gland bolts.
3. Check condition of...
IPS at Channpatna
1. Check free movement of the gland of the stuffing box; check gland packing and replace if necessary.
2. Clean and apply oil to the gland bolts.
3. Check condition of bearing and ...
II PART C Event Oriented (Electromechanical ) Rewinding of monoblock motor with copper insulaton wire suitable gauge as per ISI specification with all necessary materials and labour,tools and equipmen...
do 150 HP Motor rewinding
do 400 HP Motor rewinding
do 150 HP Rewinding of Verticle turbine pump
Providing Ball bearing as per ISI specification with guarantee period of not less than 12 months with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-I...
Providing thrust bearing as per ISI specification with guarantee period of not less than 12 months with all lead and lift, transportation etc. complete as per specifications and directions of Engineer...
Providing terminal plate as per ISI specification with guarantee period of not less than 12 months with all lead and lift, transportation etc. complete as per specifications and directions of Enginee...
Terminal plate 150 to 200
Repairs to Verticle turbine pumps as per ISI specification with guarantee period of not less than 12 months with all lead and lift, transportation etc. complete as per specifications and directions ...
Supply of Bearing for Horizontal Pump with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
For 100 to 150 HP Pump
Water Treatment Plants HORIZANTAL PUMP ALL TYPES-For Pump open & refitting after repairs with all lead and lift, transportation with all lead and lift, transportation etc. complete as per specificatio...
do 150 HP to 250 HP
Supply of Side gland bush with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
- 100 HP to 150 HP
do 150 HP to 250 HP
Impeller breezing and making with all lead and lift, transportation with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge - 100 HP to 150 HP
do 150 HP to 250 HP
Shaft steel welding and making bearing sheet -with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge 100 HP to 150 HP
For Shaft threading making with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
- 100 HP to 150 HP
For joint rope of 1 Kg with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
100 HP to 150 HP
Pump shaft bend thrown with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
- 100 HP to 150 HP
Transportation with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
- 100 HP to 150 HP
Pump shaft getting check nut with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
- 100 HP to 150 HP
Both Coupling new set with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
100 HP to 150 HP
Changing the pump packing with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
Changing the 16 gland packing with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
Supplying motor pump coupling bolt and nuts washer with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
Supplying Rubber gasket bolt and nuts washer with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
Reconditioning of bronze impeller with new rings all new PB 2 materials rate inclusive of making charges and leath work etc complete as per standard practice. with all lead and lift, transportat...
Repairing carbon Steel/SS shaft EN-8 with all materials with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
Removing the worn out neck rings policing and ovality changing as per original design with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
Removing the worn out sleeves mechanary policing and as per original design with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
Dismantling pump and all the rotating elements and assembling the pump with all the rotating element and alignment with necessary materials including pump repair charges with all lead and lift, transp...
Motor pump dynamic balancing test and trail run labour charge with all lead and lift, transportation etc. complete as per specifications and directions of Engineer-Incharge
Transformer Repairs Scope:
Repairs and Reconditioning of 11KV class single coil/multi coil Conventional (Aluminium wound) and 3/4/5 Star Rated failed Distribution Transformers of various Capacities a...
do 300KVA, 400KVA, 500KVA
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .