Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-AOC AT SIBA MANDIRA SABALSINGPUR PO SANA ADHANGA PS PATKURA DIST KENDRAPARA STATE ODISHA PIN 754134 | PATKURA | KENDRAPARA | ODISHA | 754134 | ₹43.1 L | L1 | Accepted-AOC Awarded Work Order vide Letter No.565 Dtd.04.04.2026 |
| 2 | L1₹43.1 LRejected-AOC AT WARD NO 27 H NO 33 A PITHAPUR PO BUXI BAZAR DIST CUTTACK PIN 753001 | CUTTACK | CUTTACK | ODISHA | 753001 | ₹43.1 L | L1 | Rejected-AOC Due to selection of Umakanta Parija as L1 bidder through transparent lottery system. |
| 3 | L2₹45.7 LRejected-AOC AT GUALIGAN PO TARASA PS RAJKANIKA DIST BHADRAK PIN 754220 | GUALIGAN | BHADRAK | ODISHA | 754220 | ₹45.7 L | L2 | Rejected-AOC Due to selection of Umakanta Parija as L1 bidder through transparent lottery system. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Due to non fulfilment of the minimum annual turnover requirement as stipulated in DTCN Clause 105 e i |
Updated dates
Tender Value
₹50.8 L
EMD Value
₹50,800
Closing Date
19 Jan 2026, 5:00 pmClosed
Superintending Engineer, Ports and IWT, Civil Divi
Superintending Engineer, Ports and IWT, Civil Division, Near STPI, Ambapua, Berhampur
Improvement of the existing jetty and public rain shelter at Talachua in Kendrapada District, Odisha
2026_PIWT_124080_1
S.E./PandI.W.T (C.D.)-09/2025-26
National Competitive Bid
Civil Works - Buildings
120 days
KENDRAPADA
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹50,800
Yes
2 May 2026
1 Jan 2026
20 Jan 2026
1 Jan 2026
19 Jan 2026
1 Jan 2026
1 Jan 2026 - 17 Jan 2026
Chipping 50mm Average Thickness of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete with including cost of all labour, labour cess, T&P etc complete and as per direction of Engineer-in- Charge.
Chipping 25mm Average Thickness of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete including cost of materials and conveyance of all materials, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge. (Below Water & Extra time consuming for tidal influence) (Temporary stage/platform paid saparately)
Scraping old paint with scrapers, sand papering and washing with soap water or soda including scaffolding charges upto 5M height and including cost of all labour, labour cess, T&P etc complete and as per direction of Engineer-in- Charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhate, architrave, holdfasts etc. complete and stacking within 50 metres lead including cost of all labour, labour cess, T&P etc complete and as per direction of Engineer-in- Charge.
Repair of RCC railing (assuming 60% damage) including chipping and removal of damaged concrete, cleaning of exposed steel reinforcement, application of bonding agent, providing and placing RCC M30 with reinforcement, finishing, curing, and all incidental works: chipping/removal of damaged concrete, cleaning steel reinforcement, bonding agent application, RCC M30 with reinforcement, finishing and curing as per technical specifications, including scaffolding, T&P, labour, and all incidental charges; all rates include cost of materials, labour, conveyance, royalty, taxes, and as directed by the Engineer-in-Charge.
Providing un-reinforced, dowel jointed cement concrete pavement over a prepared sub base as per approved mix design, using 43grade cement not less than 400kg/cum, coarse and fine aggregates conforming to I:S 383, maximum size of coarse aggregate not exceeding 25mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip from paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler,separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per approved drawing and technical specification complete in all respect as per Section 900 & Clause 602 of MoRT&H Specifications for Road and Bridge works (5th Revision) & including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge.
Construction of footpath/separator by providing a 150 mm compacted granular sub base as per clause 401 and 25 mm thick cement concrete grade M15, over laid with pre-cast concrete tiles in cement mortar 1:3 including provision of all drainage arrangements but excluding kerb channel and including cost & conveyance of all materials, labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge.
Providing temporary stage/platform for boring and casting of piles during LTL & HTL, using 200mm mean dia Non-Sal Bullah for piling @1.00mtr c/c with 100mm mean dia Non-Sal Bullah bracings on both ways in 3 layers in middle and top layer with 38mm thick Non-Sal wooden planks fixed over 100mm mean dia Non-Sal Bullah reapers or any advance method of stagging as approved by the E.I.C. and dismantling the same after completion of the work and clear the debries including cost of transportation, labour, labour cess & all other taxes etc. complete in all respect as per direction of Engineer-in-Charge. (80% payment will be made after completion of staging work and 20% will be made after dismanting and clearing the same from work site)
Providing and laying R.C.C M-20 grade for wall using 20 mm down H.G.C.B. chips, including mixing, hoisting, laying, compacting, curing, watering, rigid formwork, cost of materials, conveyance, taxes, royalty, labour, labour cess, T&P etc., complete as directed by Engineer-in-Charge.
Supplying, fabricating & placing HYSD (FE-415/FE-500) steel including cutting, bending, binding, welding, placing, taxes, conveyance, binding wire, labour, labour cess, T&P etc., complete as directed by Engineer-in-Charge. (Brand: SAIL/ Vizag/TATA/SHYAM)
Supplying, fitting & fixing of M.S. Grill for doors, Windows & Ventilators of approved design including cost, conveyance, fabrication charges, labour, T&P including cost & conveyance of all materials, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge
12 mm thick cement plaster in CM (1:3) over brick masonry, including cost of scaffolding, staging charges, conveyance of all materials, taxes, royalty, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge (Inside of Ground Floor)
Supplying, fitting & fixing Granite Tile up to 0.10 Sqm. (10mm thick) in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) (1 cement, 1 sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including cost & conveyance of all materials, taxes, royalty, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge
Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures including cost & conveyance of all materials, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge
Supplying , fitting and fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures including cost & conveyance of all materials, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge
Priming one coat with approved Water bound cement primer including cost of Primer, cost of scaffolding, staging charges and conveyance of all materials, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge
Finishing walls with Weather coat (ISI) of approved shade in new work two coats to give an even shade including cost of paint, cost of scaffolding, staging charges and conveyance of all materials, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge
Painting 2 coats to walls with Plastic emulsion paint of approved shade on new work to give an even shade including cost of paint, cost of scaffolding, staging charges and conveyance of all materials, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge
Priming one coat with any approved primer including cost of paint, cost of scaffolding, staging charges and conveyance of all materials, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge. (For Iron work )
Painting two coats with approved paints on new iron work including cost of paint, cost of scaffolding, staging charges and conveyance of all materials, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm including cost of paint, cost of scaffolding, staging charges and conveyance of all materials, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete including cost of materials and conveyance of all materials, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge. (Below Water & Extra time consuming for tidal influence) (Temporary stage/platform paid saparately)
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete including cost of materials and conveyance of all materials, royalty taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge With cement mortar 1:3 (1 cement : 3 fine sand)
Guniting assuming thickness 25mm concrete surface with cement mortar applied with compressor after cleaning surface and spraying with epoxy complete including cost of materials and conveyance of all materials, royalty, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge
Epoxy bonding of new concrete to old concrete including cost of materials and conveyance of all materials, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge
Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy including cost of materials and conveyance of all materials, royalty, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge. (Below Water & Extra time consuming for tidal influence) (Temporary stage/platform paid saparately)
Sealing of cracks/porous concrete by injection process through nipples using Cement Grout complete as per Technical Specification including cost of materials and conveyance of all materials, royalty, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge. (Below Water & Extra time consuming for tidal influence) (Temporary stage/platform paid saparately)
Applying epoxy mortar over leached, honey combed and spalled concrete surface and exposed steel reinforcement complete as per Technical Specification including mixing, hoisting, laying, compacting, curing, watering, rigid formwork, cost of materials, conveyance, taxes, royalty, labour, labour cess, T&P etc., complete as directed by Engineer-in-Charge. (Below Water & Extra time consuming for tidal influence) (Temporary stage/platform paid saparately)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc.complete including cost of materials and conveyance of all materials, royalty, taxes, labour, labour cess, T&P, and all incidental charges required for proper completion of the work, complete as directed by the Engineer-in-Charge. (Below Water & Extra time consuming for tidal influence) (Temporary stage/platform paid saparately)
On Steel Surface
On Concrete Surface
Supplying approved Marine ''D" hallow Rubber fender of size 150 x150 x25 mm as per specification and drawing including cost & taxes of Fender with transport charges to deliver at work site etc. complete in all respect as per the direction of the Engineer in charge.
Labour for cutting Marine ''D" hallow Rubber fender of required size and fitting &fixing the same as per specification and drawing along the jetty fender beam using stainless steel Anchore bolts, Nuts and washers of required size by drilling holes in the existing concrete surface and making good good of the damage with cement mortar(1:1) (1cement :1sand) including cost, conveyance, taxes of all materials labour, labour cess, T&P etc. required to complete the work in all respect as per drawing,design specification and direction of Engineer in charge (Excluding cost of Fender)
Recessed wiring to Tube light point/fan point/exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metalic PVC flexible conduit with 5A,250V Modular type switch (Make Cona/Anchor/ Havels ) & ceiling rose (Make Cona/Anchor/ Havels ) mounted on MS Box having front bakelite cover of suitable size with 1.0 Sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connections as per the direction of Engineer-in-charge. (Make of wire Finolex/ L&T/Anchor/ Havels/ V Guard).(Excluding the cost of sypplying and fixing of 100mmx100mmx60mm MS Box with backlight cover-1no switch Box)
Supplying & fixing of Modular GI box for 2-modules, 18 SWG (Nominal size) on surface/ recess with suitable size of Modular Base & Cover in front including cutting the wall & making good the same in case of recessed conduit as required including all accessories and connections including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge.
Supplying & fixing of Modular GI box for 8-Modules, 18 SWG (Nominal size) on surface/ recess with suitable size of Modular Base & Cover in front including cutting the wall & making good the same in case of recessed conduit as required including all accessories and connections including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge.
Supplying & fixing of 5 pin 5/6 amp Modular Type Switch and 5/6 amp Modular Type socket outlet on the existing switch box/ cover including connections etc. including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge.
Installation, Testing and Commissioning of Step type modular ceiling fan regulator - IS Mark, in existing switch box including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor, earthing the regulator including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge.
Supplying and drawing 1x1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in existing surface/recessed PVC conduit as required i including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge. (Make of wire Finolex/ L&T/Anchor/ Havels/ V Guard).
Surface wiring to sub-main in 2x2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 20mm dia non-metalic heavy duty flexible conduit 1.6mm thick alongwith 1 x 1.5 Sq.mm FR PVC insulated single core multistrand copper conductor as earth wire etc. as required including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge. (Make of wire Finolex/ L&T/Anchor/ Havels/ V Guard).
Recessed wiring to sub-main in 2x1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS 694/1990 in 20mm dia non-metalic heavy duty flexible conduit 1.6mm thick alongwith 1 x 1.5 Sq.mm FR PVC insulated single core multistrand copper conductor as earth wire etc. as required including all accessories and connections including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge. (Make of wire Finolex/ L&T/Anchor/ Havels/ V Guard).
Supplying & fixing of 5amp to 32amp rating 240V "B" series miniature circuit breaker suitable for lighting & other loads of the Single poles in the existing MCB DB ISI marked complete with connections testing and commissioning etc. including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge.
Supplying & fixing of Modular Blanking Plate of ISI Marked on the existing Modular switch board including connections etc. including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge.
Supplying & fixing of Tube light of ISI Marked on the existing Modular switch board and celing rose including connections etc. including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge.
Supplying Fitting & Fixing, Installation, testing and Commissioning of Ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5sq.mm FR PVC insulated single core multistrand copper conductor etc. including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge.
Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm 1600 cmh air delivery with louvers (Halonix heavy duty or any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection complete etc.as required and as per the direction of E.I.C.
Supply, Installation, Testing, and Commissioning of 63 Amp DP Main switches of following capacity (IS 13940 Part 3/1993 ) on existing surface / wall mountnting and complete with HRC Fuse links, interconnections, earthing, etc. including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge. Make-SEIMENS/HPL/ANCHOR/L&T/HAVELS/C & S/ RK
Supplying & fixing of 2 WAY , SPN, Single Door MCB-DB with sheet steel enclosure, distribution board, on surface/ recess complete with tinned copper bus bar, neutral box bar, earth bar, din bar, detachable gland plate , inter connection , phospate & powder painted including earthing etc. as required (but without MCB/RCCB/Isolator) including all accessories and connections including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge.
Earthing with GI earth pipe 3m long 40mm dia ISI marked including all accessories and providing masonary enclouser with cover plate having locking arrangement and watering pipe etc. with charcoal & salt including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge.
Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing from earth electrode to PANNEL BOARD including cost of all materials, labour & labour cess complete as per specification and direction of Engineer-in-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.09 MB
DTCN.pdf
Tender Documents • 2.65 MB
BOQ_574025.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid