| # | Company | Status |
|---|---|---|
| 1 | Rejected-Technical | Rejected-Technical Agency is not technically qualified. |
| 2 | Rejected-Technical | Rejected-Technical Agency is not technically qualified. |
| 3 | Rejected-Technical | Rejected-Technical Single agency is technically qualifed hence bid is rejected. Tender will be recalled. |
Tender Value
₹91.8 L
EMD Value
₹1.8 L
Closing Date
16 Apr 2026, 3:00 pmClosed
Director IISER Pune
IISER Pune Dr Homi bhabha road Pashan Pune 411008
Providing Optical Fiber Cable network at IISER Pune Campus
2026_IISRP_901612_3
36/IISER/Pune/2025-26
Open Tender
Electrical Works
Works
180 days
IISER Pune
As per NIT
3 documents required · 3 mandatory
₹1,180
Director IISER Pune
₹1.8 L
29 Apr 2026
8 Apr 2026
17 Apr 2026
8 Apr 2026
16 Apr 2026
8 Apr 2026
Bidder Please note that, quoted rate are inclusive of tranportation, labour, royalties taxes etc. except GST. GST will be paid as Govt of India, rules and regulation.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of Optical Fiber cable following size in the existing RCC/ HUME/ METAL / PLB pipe as required. ( 6 core / 12 core )
Providing cable dressing, cleaning, labelling of OFC network rack upto 42 U with required self adesion tape as per instructed by Engineer in charge., as complete.
Splicing / Termination of Fiber Optic Cable Cores using Fusion splicing with pre-terminated SC pigtails, dressing and proper fixing in splice trays. Including Splicing Kit. As complete.
Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro hromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 276 DELHI SCHEDULE OF RATES (E&M)-2025 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc complete as required. Single Mode 6 Core Optical fiber cable
Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro hromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 276 DELHI SCHEDULE OF RATES (E&M)-2025 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc complete as required. Single Mode 12 Core Optical fiber cable
Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode SC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required. 6 port LIU
Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode SC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required. 12 port LIU
Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode SC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 μm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- SC-LC Duplex etc complete as required.
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed Horizontal cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. 9 U rack
Supplying and fixing 42U Rack with 6 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.6mm CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 8nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Horizontal , Hardware mounting screws packet of 20 x 1 number, 2 vertical cable organizer ( full length ) PVC with sliding, etc. complete as required.
Testing and commissioning of each splicing work done on OFC cable by using fluke testing meters for continuty and submission of report for status of each termiantions. If found faulty or malfunctioning , making it functional , with port labelling will be scope of agency. Rates quoted for each for testing on OFC splicing work.
Supply of PLB HDPE Duct pipe of 40 mm dia for cable laying , as complete.
Laying of one number PLB HDPE Duct of 40 mm dia in the existing masonry open duct as required.
Laying of one number PLB HDPE Duct of 40 mm dia ( below minimum 0.7 m ground level ) direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying and fixing of one number PLB HDPE Duct of 40 mm dia on cable tray as required.
Removing of exisiting armoured cable from surface/ cable tray. Shifting, store of cable in same campus is in scope of agency. During removing of any item from site, nothing should be damaged in such manner to become unservisable. etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately. For DB cable / power cable / fume hood cables / fume hood communication cable / fire detector cable ( Upto 35 sqmm )
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire ( Approved make : Polycab / Finolex / RR Kabel )
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25 MM ( Approved make : Precision / Diamond / Modi )
16 AMP Switch: Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as requiredincluding connections, as required. . 15/16 amp switch ( Approved make : MK Honeywell / Legrand )
Supplying and fixing following Modular socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required. . 6 Pin 15/16 amp socket outlet ( Approved make : MK Honeywell / Legrand )
POWER SWITCHES / SOCKETS on walls - G.I. BOX. : Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc, as required. ( The job includes cutting & chasing existing wall, fixing the box in position as required including rough plastering.) (In all the rooms, vertical drops of conduits and switch boxes shall be concealed in the wall). Boxes should be of same make as that of modular accessories. :6 Module
Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. . 6 Module Box with faceplate & cover ( Approved make : MK Honeywell / Legrand )
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm Each thick G.l. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. ( FOR OFC CABLE )
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Hard Rock ( blasting prohibited )
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 450 mm dia RCC pipes.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).
Laying and fixing of one number PLB HDPE Duct of 40 mm dia on wall surface as required. (clamped with 1mm thick saddle)
Providing and fixing LD FRP chamber cover up to load carrying capacity of 2.5 T as per IS standards. Chamber cover shall be along with frame. Quoted rate shall be removing existing chamber frame and cover and fixing new FRP chmaber cover and frame including necessry fixing arrangement etc., as complete.
Core cutting in brickwork/RCC up to 300mm depth for 100 mm dia including cost packing of gap between pipe and with apropritae expoxy base filling etc complete and as per Direction of Engineer In-charge.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.37 MB
Tenderdocuments2.pdf
Tender Documents • 15.56 MB
BOQ_950991.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .