| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | ₹2.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹3.0 L+₹33,218.76 (12.2%)Rejected-Finance | ₹3.0 L+₹33,218.76 (12.2%) | L2 | Rejected-Finance L2 |
Tender Value
₹2.8 L
EMD Value
₹5,536
Closing Date
29 May 2026, 12:00 pmClosed
Er. Ravinder Singh
Executive Engineer, Electrical Division No. 2, 1st Floor Additional Deluxe Building Sector- 9/D, Chandigarh.
As per NIT
2026_CHD_92501_1
E2/26/44
Open Tender
Electrical Works
Percentage
365 days
Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹5,536
29 Jun 2026
19 May 2026
29 May 2026
19 May 2026
29 May 2026
19 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing Annual comprehensive maintenance of complete fire sensing and Public Address System (Bosch make) installed in Block-C, GMCH, Sector-32 Chandigarh. Under the AMC the firm shall provide preventive maintenance service of the system. The service must be carried out weekly and the complaint call must be attended by the firm in addition to the general maintenance within two hours from the time of such calls. (Please refer DNIT for complete specification of item no.1) | 1 | Each job per year | 2,21,400 | ₹2,21,400 |
| 2 | Supply, installations, testing and commissioning of intelligent multisensor detector with integrated fault isolator/ isolator base.(Please refer DNIT for complete specification of item no.2) | 5 | Each | 2,560 | ₹12,800 |
| 3 | DSR item No.28.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. | 3 | Each | 4,063 | ₹12,189 |
| 4 | DSR item No.28.2.6 Supplying, installation, testing & commissioning of intelligent addressable programmable sounder complete as required. | 3 | Each | 2,787 | ₹8,361 |
| 5 | DSR item No.28.3.3 Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. | 3 | Each | 1,891 | ₹5,673 |
| 6DSR item No.1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||||
| 6.01 | 2 x 1.5 sq.mm | 100 | PM | 77 | ₹7,700 |
| 7DSR item No.28.5.3 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. | |||||
| 7.01 | Speaker Cable Single Pair, 2 Core, 1.5 sq.mm | 100 | PM | 61 | ₹6,100 |
| 8Supply, erection, testing & commissioning of batteries of the following capacities after dismantling the old / defective batteries from the site. The job includes the cost of making connection of new battery with suitable rating copper wire, thimbles & any other petty material required to complete the job to the entire satisfaction of the Engineer-in-charge. The batteries should be of Exide / Amaron / Tata Green / Panasonic make only. The guarantee card of the battery shall have to be submitted before installing the same at site. | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 10.84 MB
BOQ_113186.xls
BOQ • 0.28 MB
044.pdf
PDF • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .