| Sl No | Description | Qty | Unit | M/S LATIF AHMAD MIR L3 | ORISON ENTERPRISES L1 | M/s Nasir Rasool Dar L2 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for repairing a chiller plant panel board with a capacity of 26 TR, which serves a WSA chiller plant with two compressors (13 TR each). repair includes rewiring the panel, replacing unserviceable switch/control gears, LED display control panel, meters, selector switches, and indicator lamps. The work also involves extending incoming and outgoing wires by adding lugs or thimbles as required. Also, replace any unserviceable fuses , ensuring the chiller plant panel board is fully operational and compliant with safety standards complete all as specified and as directed by the Engineer-in-Charge. | 1 | Each Job | 75,000 ₹75,000 | 5,000 ₹5,000 Lowest | 10,000 ₹10,000 |
| 2.00 | M&L for repairing a water cooled package type chiller plant panel board of make Bluestar with a capacity of 10/15 TR, which serves a chiller plant with two compressors (5.5 TR each). Repair includes rewiring the panel, replacing unserviceable switch/control gears, LED display control panel, meters, selector switches, and indicator lamps. The work also involves extending incoming and outgoing wires by adding lugs or thimbles as required. Also, replace any unserviceable fuses , ensuring the chiller plant panel board is fully operational and compliant with safety standards complete all as specified and as directed by the Engineer-in-Charge. | 2 | Each Job | 70,000 ₹1,40,000 | 3,500 ₹7,000 Lowest | 10,000 ₹20,000 |
| 3.00 | Supply and install in replacement an existing M2VPD single and twin motor protection device with a new model featuring an LED screen panel for voltage and current display. This device must provide comprehensive protection, including overvoltage, undervoltage, single-phase protection (SPP), phase reversal (PH-r), and unbalanced voltage/current. The device should come with inbuilt calibration facilities and integrated 3-phase current transformers (CTs) for maximum reliability in monitoring two motors (a total of 6 CTs) complete all as specified and as directed by the Engineer-in-Charge. Make: Softhard or equivalent. | 1 | Each Job | 45,000 ₹45,000 | 6,000 ₹6,000 Lowest | 7,000 ₹7,000 |
| 4.00 | M & L for cleaning/servicing of cooling tower by using of chemical, natural draught type/FRP type of the following capacities central AC plant including removing of existing choked fins of 60 TR cooling tower cap and S&F of new fins of cooling tower for AC plant including replacement of Wire mess protector jali , cleaning of water tank, cleaning of nozzels (brass/PVC), including replacement unsv nozzels all as specified and directed. | 1 | Each Job | 45,000 ₹45,000 | 2,500 ₹2,500 Lowest | 7,000 ₹7,000 |
| 5.00 | Ditto as srl no 4.00 but for 20 TR capacity cooling tower. | 1 | Each Job | 44,000 ₹44,000 | 2,000 ₹2,000 Lowest | 5,000 ₹5,000 |
| 6.00 | M&L for descale a water-cooled shell-and-tube condenser by disconnecting the inlet and outlet water connections, installing dummy plugs, and circulating a descaling agent (R-111 or equivalent) until all scale is removed from the copper tubes. Open both end covers, brush the tubes with a nylon brush, then flush them with water. After cleaning, reassemble the condenser, replace damaged rubber gaskets, and reconnect the water inlet and outlet connections. Test for leaks to ensure proper sealing complete all as directed by engr-in-charge Note: de-scaling operation to be done by OEM only.
(a) Condenser unit of capacity 26 TR of WSA | 3 | Each Job | 35,000 ₹1,05,000 | 3,000 ₹9,000 Lowest | 6,000 ₹18,000 |
| 7.00 | Ditto as serial No 6.0 but of capacity 10 TR of RPA Tech Flt | 3 | Each Job | 32,000 ₹96,000 | 2,500 ₹7,500 Lowest | 5,000 ₹15,000 |
| 8.00 | Taking down of U/S Commercial scroll sealed compressor Model NP SZ185S4RC from the location by OEM only. Remove pressure from both the high and low side before cutting out the compressor copper pipes by tubing cutter complete all as specified.. | 1 | Each Job | 100 ₹100 Lowest | 1,000 ₹1,000 | 2,000 ₹2,000 |
| 9.00 | M&L for installation , commissioning, testing in replacment of new commercial scroll sealed compressor Model No SZ185S4RC of capacity 13 TR for central type water chiller plant, max operating 35 Ampere LR 175A, suction pressure varying from 25 bar to 31.9 bar TS max varries from 54 degree C to 65 degree C from LP side to HP side & TS min varries from -35 degree C to -35 degree C from LP side to HP side refrigeration water chiller type, refrigerant R 407C, lubricant oil type mineral oil, P.O.E. 160 SZ. complete all including necessary brazing and as specified and as specified and as directed by Engr-in-Charge. Note: Supply & installation to be performed by OEM of existing make only. | 1 | Each Job | 1,45,000 ₹1,45,000 | 1,15,000 ₹1,15,000 | 60,000 ₹60,000 Lowest |
| 10.00 | Taking down of U/S Commercial scroll sealed compressor Model ZR 72KCE-TFD-52E Make: Copeland from the location by OEM only. Remove pressure from both the high and low side before cutting out the compressor copper pipes by tubing cutter complete all as specified.. | 2 | Each Job | 1,000 ₹2,000 Lowest | 1,000 ₹2,000 Lowest | 2,000 ₹4,000 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
23 Oct 2025, 6:00 pmClosed
CWE AF SRINAGAR
SRINAGAR
REPAIR/MAINT OF PACKAGE TYPE ACs CENTRAL TYPE AC AND OTHER CONNECTED ITEMS AT 8 FBSU AF STN AWANTIPUR
2025_MES_732866_1
CWE(AF)SGR/AWA-39/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE AF AWANTIPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
₹20,000
Yes
19 Nov 2025
26 Sept 2025
29 Oct 2025
26 Sept 2025
23 Oct 2025
11 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
TENDER39.pdf
Tender Documents • 0.80 MB
BOQ_820552.xls
BOQ • 1.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .