Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | KL1₹32.1 LAccepted-AOC 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | KL1 | Accepted-AOC L1 | |
| 2 | L2₹38.3 LRejected-AOC 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L2 | Rejected-AOC L2 | |
| 3 | L3₹39.6 LRejected-AOC 10 RAJAN KUNJ ROORKEE ROAD MEERUT 250001 | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹39.8 LRejected-AOC 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L4 | Rejected-AOC L4 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
16 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(U) E/M Meerut Cantt
GE(U) E/M Meerut Cantt
TENDER FOR ITEM RATE CONTRACT FOR MAINTENANCE REPAIR / REPLACEMENT OF STREET LIGHT IN SOUTH AND NORTH AREA UNDER AGE E/M ES AT GE(U) E/M MEERUT CANTT
2021_MES_451545_1
8319/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Meerut Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE(U) E/M Meerut Cantt
₹84,000
Yes
14 Sept 2021
16 Jun 2021
23 Jul 2021
16 Jun 2021
16 Jul 2021
1 Jul 2021
16 Jun 2021 - 24 Jun 2021
60 days
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations etc. or for shafts, well cess pits, manholes,pier holes, laying of pipe and cables etc. but not exceeding 10 sqm on plan including dressing/trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified.
Returning ,filling in , including spreading , levelling , watering and well ramming in layer not exceeding 25 cm thick in soil complete all as specified.
Material and labour river sand for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . ( Note: Punned thickness shall be measured for the purpose of payment)
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
M&Lfly ash old size bricks , straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Taking down existing unserviceable pipe and supplying and fixing 40mm nominal bore Galvanised mild steel pipe /tubing, light grade for protection of earth lead / passing cable complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified (Excavation & Earth work , Mild steel clamps, bolts , nuts and washers shall be measured and paid separately)
M&L for auguring of hole suitable for passing 40mm to 100mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line specified and directed coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified. Note: Pipe shall be measured and paid separately under appropriate items and any dahage to existing cables of anytype shall be made good by the Bidder without any extra cost to department.
Trimming/ lopping branches of tree touching to LT/HT OH lines not exceeding 30 cm girth , shrub, vegetation, bushwwod and saplings at least upto 3 M from outer edge of ACSR including removing of braches of trees etc. to a distance exceeding 100 m and not exceeding 150 M complete all as specified and directed. Note :- (i) Shutdown wherever required shall be taken in writtig from Engr-in-Charge.
Taking out unserviceable cable and Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 16 sqmm 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Taking out unserviceable cable and Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 16 sqmm 4 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Taking out unserviceable cable and Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 25sqmm 4 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Taking down existing unserviceable service main Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by (existing insulating hangers not more than 1 metre apart including 4 mm suspension wire), one twin core 16 sqmm flat cable complete all as specified and directed.
Taling down of existing unserviceable SPN DB with MCB enclosure and Supply and fix SPN DBs double door for lexic MCB complete with SPN MCB 63 Amps 10 KA , 240V all as specified.
Taling down of existing unserviceable wire and Supply and fix fire retardent low smoke ( FRLS) PVC insulated unsheathed multi stranded aluminium conductor, single core 1100 V grade of 2.5 sqmm size for street light terminal to over head conductor complete all as specified.
Taking down unserviceable PVC rigid conduit and S&F 20 mm external dia. Rigid non metallic PVC conduit medium grade, exclusive of boxes ( Junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers , lock nuts, saddles, pipe hook, etc. fixed to poles with suitable size of PVC straps at every 50 cm complete all as specified and directed.
Taking down of existing unserviceable junction box of any size and type and removing from site complete all as specified.
S&F pole mounting type junction box factory made of size 350x250x150mm of CRCA sheet duly powder coated with front openable hinged door , locking arrangements, with 4 Nos aluminium bus bars 40 Amps rating mounted on porcelain insulator, cable glands and lugs consisting DIN type rails for fixing MCB SP 6/10 Amps, 10 kA, suitable for domestic loading -01 no. including mild steel flat iron clamp made out of 40x4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.(MCB shall not be measured and paid separately and shall deemed included in the unit rate)
S&F pole mounting type junction box factory made of size 250x250x150mm of CRCA sheet duly powder coated with front openable hinged door , locking arrangements, with 2 Nos aluminium bus bars 40 Amps rating mounted on porcelain insulator, cable glands and lugs consisting DIN type rails for fixing MCB SP 10 Amps, 10 kA suitable for domestic loading , -01 no. including mild steel flat iron clamp made out of 40x4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.(MCB shall not be measured and paid separately and shall deemed included in the unit rate)
Dismantling the existing unserviceable mild steel swaged poles or serviceable tilted steel pole of any size, from ground after necessary excavation etc and removing the same including disconnecting cables/ overhead conductor and making good disturbed ground complete all as specified. Note: Excavation and earthwork shall be deemed included in the unit rate quoted by bidder.
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron / Mild steel base plate, CI finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work in soft/ loose soil , PCC 1:3:6 type C2 in foundation and around poles and PCC 1:2:4 type B1 as in plinth block duly finished even and smooth without using extra cement, disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting exposed surafces steel tubular poles with two coats of aluminium paint over one coat of red oxide primer and and black bituminous paint on steel surafces embedded in concrete and providing 300 mm wide bands (5 bands/ straps with fluorescent synthetic enamel paint in alternate colour of black and white from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and shown in drg No.TD/EM/1and directed.
M&L for preparation of old painted surfaces erected steel tubular swaged poles / Rails/Girder poles of LT over head line ( Except embedded portion) , 9 M long including all MS work mounted on pole , earth protection & water pipe ( if exists) and providing one coat of aluminium paint and providing 04/ 05 Nos bands/ straps with Two coats of synthetic enamel paint ( black & yellow and Black and red white 30 cm wide each) from top of plinth block and numbering of poles with white synthetic enamel paint on yellow synthetic enamel piant ground (50mm wide and 100mm high letters) including encircling the letters or figures complete all as specified
Taking down existing unserviceable MCB and S & F Miniature circuit breakers SP, 6 to 32 Amps, 240 Volts , 10 KA, 'C' curve rating and to be housed in sheet metal enclosures ( distribution boxes) complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
S & F (in repairs) Miniature circuit breakers TPN, 32Amps, 415 Volts , 10 KA, 'C' curve rating and to be housed in sheet metal enclosures ( distribution boxes) complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
S & F (in repairs) Miniature circuit breakers TPN, 63Amps, 415 Volts , 10 KA, 'C' curve rating and to be housed in sheet metal enclosures ( distribution boxes) complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
Taking down LED street lights fittings from pole/ walls, opening of street light fittings of any type, wattage and make, making the light fittings operational to give the rated illumination by repairing/ renewal/ replacement of components viz driver, LED bulbs, electronic circuit and other minor defective parts and refixing the street light in its original position and reconnecting with renewed cable of Twin core 2.5 sqmm stranded aluminium conductor cable ,PVC insulated and PVC sheathed cable of required length complete all as specified and directed. Note:- Driver, electronic circuit and LEDs only if renewed shall be measured separately at supplied only rates. (ii) Reparing to street light fittings shall be carried out at MES store yard of AGE E/M ES at Meerut.
Supply only Driver suitable for 25 watt LED light fittings, 140V to 270V universal driver with built in surge protection>5KV, 50 Hz +/- 3%, P.f.>0.95, Thd<10% with system efficiency >85 lumens per watt and power efficiency >= 90% and protection IP 65 or better .complying LM-79/IS:16106.
Supply only Driver suitable for 45/48 watt LED light fittings, 140V to 270V universal driver with built in surge protection>5KV, 50 Hz +/- 3%, P.f.>0.95, Thd<10% with system efficiency >85 lumens per watt and power efficiency >= 90% and protection IP 65 or better .complying LM-79/IS:16106.
Supply only Driver suitable for 60/70/72watt LED light fittings, 140V to 270V universal driver with built in surge protection>5KV, 50 Hz +/- 3%, P.f.>0.95, Thd<10% with system efficiency >85 lumens per watt and power efficiency >= 90% and protection IP 65 or better .complying LM-79/IS:16106.
S&F 40 mm nominal bore GI pipe brackets made out of light grade pipe of required length not less than 1.50 M consisting adapter to suit the opening of street light fitting, mounting brackets made out of 350 mm long or higher mild steel FI 40x6 mm required shape ( two Nos per GI pipe brackets ) duly fitted with 4 nos Mild steel bolts 10mm dia ,50mm long with nut and washers to poles etc. and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer; complete all as specified.
Supplying, Installation, testing and commissioining 3 Phase, 4 wire, 5 KVA, Group Control Management System (GCMS) Central LT panel comprising On-Off of Contactor for colective control, input and output MCBs of suitable capacity and numbers, 3 Phase digital panel Meter , remote data monitoring, notifications of faults, suitable for surge protection, rotary switch for manual operation, made out of 2mm thick CRCA sheet duly powdered coated, factory made, floor mounted type, having arrangemnets for connceting to earthings complete all as specified and directed. Note:- The GCMS shall have the follwoing features:- (i) Input to GCMS shall be 3 Phase/ 1 Phase grid power input and with 3 Phase ( Common phase/ Individual phase Control/1 phase output for load with option to switch on and off the load (ii) Comminication -GPRS communication between GCMS and cloud server street lights for futuristic expansion (iii) Wireless local control for field staff to on/off GCMS in case of GSM failure
Repair/maintenance of timer switch assembly of any type and make after dismantling the same from pole, detecting fault, rectifying the same, testing and refixing in the same position after repair/ renewal of defective part all as specified. Note: Parts renewed shall be paid at supply only rates
Supply only street light power timer Contactor , 04 poles, 40Amps, complete all as specified.
Supply only street light power timer Contactor , 02 poles, 40Amps, complete all as specified.
Taking down of existing street light panel and Supplying and fixing automatic operation street light timing switch having lighting control (ON-OFF) through Astronomical Calculation of Sun rise/ sun set by setting date, time and degree of longitude and latitude without separate light sensors and prewired with suitable size of copper conductor single core PVC insulated and sheathed caable and all mechanism fitted into panel, outdoor type , pole mounted with FI 25x4mm clamps , nuts, bolts and washers dully painted, connecting and testing factory made , epoxy powder coated, Single Phase street light panel, digital 24 hrs, suitable for 6KW (max) complete with 32 Amps TP Contactor, and 40 Amps SPN MCBs and fixed on pole/ wall/ feeder pillar complete all as specified and directed.
Taking down of existing street light fitting and S&F Energy saving & environment friendly LED street light made out of pressure die cast anodised aluminium housing with polycarbonate or flat glass optical cover, system power euqal to less than 90 watt with penut lens to achieve B1 class road illumination as per IS: 1944 and as per national lighting code each LED >1 watt and <3 watt , Luminous of efficiency of LED >= 135 Lumens/Watt, ,CRI >70, CCT > 5000K to 6500 K with LED life span at 70% of light output >50000 hours (L70) with suitable driver 140V to 270V universal type, with bult in surge protection >5KV, 50 Hz +/- 3% , pf 0.95, THD <10% with system efficiency >85 lumens/ Watt and power efficiency >=90% and overall IP 65 or better , , driver and luminaire shall comply LM-79/IS:16106 including 32mm nominal bore light grade GI pipe brackets made out of 1.5m long GI pipe, bent to shape, and fixed to poles/ walls with 2 Nos MS mild steel FI brackets of 40x6mm, comprising 4 Nos MS hexagonal head bolts of 12mm dia, 75mm long with washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and making connections with cable complete all as specified and directed. and making connections complete all as specified and directed by EIC.
Taking down existing unserviceable LED light fittings with brackets and Supplying, fixing connecting and testing of energy saving & environment friendly LED stret light made made out of pressure die cast anodised aluminium housing with toughened glass cover , 70/ 72 watts LED to achieve electrical safety class 1, ,CRI >70, colour temperature 5000k to 6000k with LED working life time >50000 hours burning hours with integrated constant current electronic driver, nominal voltage 240V, AC, 50 Hz, operating voltage range 120-280V, suitable for ambient environment condition of station, TDH <10%, Pf > 0.95 , lumens >80 lm/W, IP not less than IP 65, driver and luminaire shall comply not less than LM-79 or IS-16106 of 2012 including 32mm nominal bore light grade GI pipe brackets made out of 1.5m long GI pipe, bent to shape, and fixed to poles/ walls with 2 Nos MS mild steel FI brackets of 40x6mm, comprising 4 Nos MS hexagonal head bolts of 12mm dia, 75mm long with washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and making connections with cable complete all as specified and directed.
Taking down of existing unserviceable light fittings and S&F Energy saving & environment friendly LED street light fitting made out of pressure die cast anodised aluminium housing 48 Watt to achieve B1 class road illumination as per IS: 1944 and as per national lighting code using each LED >1 watt and <3 watt , LED chip efficiency >= 135 Lumens/Watt, CRI>70, CCT 5000K to 6500K with LED life span at 70% of light output >50000 hours with suitable driver 140V to 270V universal type, with bult in surge protection >5KV, 50 Hz +/- 3% , pf 0.95, THD <10% with system efficiency >85 lumens/ Watt and power efficiency >=90% and overall IP 65 or better , driver and luminaire shall comply LM-79/IS:16106 and with and including street light bracket made out of 32mm dia or higher GI pipe light grade, 1.50metre long bend to shape 120 degree angle with suitable adaptor and fixed to pole / wall/ ceiling by two Nos MS clamp made out of flat iron size 40x6mm with nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of primer complete all as specified and directed by EIC.
Taking down cable and S&F 3 core , stranded copper conductor cable 2.5 sqmm, PVC insulated and PVC sheathed , 1100 Volts grade for making connections to street light fittings complete all as specified and directed.
M/S VIJAY SINGH
SA construction co.
Shikha Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .