| 1 | L1₹11.8 LAccepted-Finance | L1 | Accepted-Finance Found OK | |
| 2 | L2₹11.8 L+₹2,490 (0.21%)Accepted-Finance | L2 | Accepted-Finance Found OK | |
| 3 | L3₹12.0 L+₹25,167.80 (2.14%)Accepted-Finance | L3 | Accepted-Finance Found OK |
Tender Value
₹10 L
EMD Value
₹10,000
Closing Date
8 May 2020, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC-I ALIGARH
LAL DIGGI ALIGARH
Various work under O and M and other related work under EDD-II, Aligarh
2020_DVVNL_465021_1
EDCA-34/2019-20
Open Tender
Electrical Works
Item Rate
60 days
EDD-II ALIGARH
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
DVVNL AGRA
₹10,000
13 May 2020
3 May 2020
8 May 2020
3 May 2020
8 May 2020
3 May 2020
180 days
Amount
Cartage of following poles Store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends also including the work of dragging etc. and also including the cost of labour, T&P carrier etc. required for proper completion of work. (Dist. 0 to 50 Kms.).
PCC poles 8.5 Mtr.
ST pole 11 Mtr.
Cartage of line material viz Weasal Conductor, GI earth wire, Cross Arm, Angle, Channel, Insulator, Clamps & other line material from Store centre or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends also including the work of dragging etc. and also including the cost of labour, T&P carrier etc. required for proper completion of work. (Dist. 0 to 50 Kms.).
Erection of single support including complete H.T/L.T fittings as per RESPO manual and as per direction of Engineer incharge including the cost of labour, T & P and carrier etc. required for proper completion of work.
PCC poles 8.5 Mtr./ST pole 11 Mtr.
Erection of 11 KV line double pole on PCC/ST pole including the work of complete line as per RESPO norm manual and as per direction of Engineer Incharge including the cost of labour, T & P and carrier etc. required for proper completion of work.
PCC poles 8.5 Mtr./ST pole 11 Mtr.
Laying , sagging, stringing, binding and jumpering etc. of old line conductor on the newly erected pole as per RESPO manual and as per direction of supervising engineer, including the cost of arrangement of labour, T&P carrier etc. required for proper completion of work.
ACSR Weasal Conductor/GI Wire
ACSR Dog Conductor
ABC cable size 3x50+1x35+1x16 Sq.mm/ 3x95+1x70+1x16 Sq.mm./3x120+1x95+1x16 Sq.mm.
Erection of section Tee pole including fixing of all fittings as per RESPO norms.
Drilling and cutting of tee off channel, V cross arms, Top channel, cross bracing angle, MS garding angle, Dropper chanel. as per specification of UPPCL construction manual including including loading and unloading at the both ends.
Grouting of PCC/ST poles as per RESPO norms including cost of grouting material (cement: sand: brick ballast) size 1500x450x450 mm).
Chopping of Tree Branches which are touching to 11 KV/LT lines.
Dismantling and removal of existing conductor from the various area preparing their coils and then stacking in the respective JE’s (Store) as per direction of Supervising Engineer. It includes the work of cartage, cost of labour, T&P carrier etc. required for proper completion of work.
ACSR Weasal Conductor/GI Wire
ABC cable size 3x50+1x35+1x16 Sq.mm/ 3x95+1x70+1x16 Sq.mm./3x120+1x95+1x16 Sq.mm.
XLPE cable size 3x120/3x185 Sq.mm.
Fixing of earthing rod as per RESPO manual and as per direction of supervising engineer including the cost of labour
Providing and fixing clamp with nut & bolts as per RESPO norms.
Safe carriage of LT cable of size 3x35/70 Sq. mm. from store to respective site of work including loading unloading at both ends.
Laying of LT cable size of 3.5x35/70 Sq.mm.
Erection and grouting of stay set including the work of nozzling etc. as per RESPO manual and also including the cost of arrangement of all grouting material, labour, T&P etc. required for proper completion of work
Providing and fixing of stay insulator.
Safe carriage & installation of transformer from Store Center or from any other place to the respective site of work through the Kachha Pacca road including the work of its loading & unloading at the respective ends, including the work of dragging etc. and also including the cost of labour, T&P and carrier etc. required for proper completion of work. (Distance 0 to 50 Km..
10/16 KVA T/F
25 KVA T/F
63 KVA T/F
100 KVA T/F
Replacement of following damaged accessories for 11 KV line:-
11 KV Disc Insulator
11 KV Pin Insulator
11 KV V-type Cross Arm/T-off channel
11 KV F-Bracket
Safe carriage of Old line material viz. Conductor, G.I. Earth wire, ABC conductor, Cross Arm, Angle, Channel, Insulators, Clamps & other line material from any other place or from site of work to the work of its loading & unloading at the respective ends including the cost of labour, T&P and carrier etc. required for proper completion of work.
Installation of extra “T”on the old erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, T&P etc. required for proper completion of work. The “T”pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement.
Safe carriage of LT distribution box (three phase) from store centre Sarsol to pit site including loading and unloading at both ends mounting and fixing on pole also by making connections as per RESPO norms.
Giving connections to the genuine consmers by connecting cable thought installed LT distribution Box as per directon of supervising engineer. It includes the cost of labour, T&P, carrier etc required for proper completion.
Providing and fixing of LT shackle insulator with nut & bolts as per RESPO norms.
Retighting of stay complete with nozelling & binding including cost of labour T&P etc required for proper completion of work.
Straightening of tilted pole at various places as per direction of JE.
PCC poles 8.5 Mtr./STP 11 Mtr
Demounting & carriage of site to Store of following capacity transformer due to damage of PCC poles including the work of its loading & unloading, dragging etc. and also including the cost of labour and T&P etc. required for proper completion of work.
10/16 KVA T/F
63 KVA T/F
100 KVA T/F
250 KVA T/F
Re-sagging of loose HT/LT line conductor as per direction of supervising engineer. It includes the cost of labour T&P carrier etc. required for proper completion of work.
ACSR Weasal/GI wire Conductor
ACSR Dog Conductor
ABC conductor size 3x50+1x35+1x16 Sq.mm./3x95+1x70+1x16 Sq.mm./ 3x120+1x95+1x16 Sq.mm.
Making the plinth of ST pole 11 Mtr.
Guarding of old 11 KV line damaged due to storm by laying two nos. GI wire parallel and fixing of lacings (tilli) at a distance at 2-3 Mtr. as per RESPO manual and also including the cost of arragement of labour, T & P etc. required for proper completion of work.
Safe carriage of XLPE cable of size 3x70/120/185 Sq.mm. from store to respective site of work including loading unloading at both ends.
Laying of 3x70/120/185 Sq.mm. 11 KV under ground cable after digging trench of 600 mm. wide, 1500 mm deep, providing the fine sand cushion beneath and above the cable. The cable shall be duly protected by Ist class bricks, two on either side and third on top of the cable, laid in series one after the other. The work includes supplying of fine sand and bricks, filling and ramming of the left out soil, closing the trench and levelling. Spare cable shall be left and buried in the trench in the shape of rings at both ends. All material (except cable), labour, T&P carrier etc, required for proper completion of work will be arranged by the contractor at his own cost.
Laying of 3x70/120/185 Sq.mm XLPE Cable overhead the existing new pole by of lifting spreading the cable conducting all labour T&P etc.
Laying of XLPE cable size 3x120/185 Sq.mm. By pushing method as per site requirement.
Providing and filling of 3x70/120/185 Sq.mm. 11 KV XLPE heat shrinkable cable jointing kits outdoor/indoor type including the cost of labour T&P carrier etc for proper completion of work.
Providing and filling of 3x185/300 Sq.mm. 33 KV XLPE heat shrinkable cable jointing kits outdoor/indoor type including the cost of labour T&P carrier etc for proper completion of work.
Installation of 11 KV CT-PT combined metering unit on double pole after fixing of channel with M.S. Clamps and nuts bolts for holding the channel angle etc. The unit body shall be earthed by connecting M.S. strip of size 1/8x1 finally connected to earthing rod of size 20mm x2540 mm. 11 KV line shall be connected to unit as per instructions of SDO/AE(M). The M.S. Strip & earth rod shall be included in the scope of work.
Demounting of damaged CT/PT pole unit after dismantling of 11 KV line opening the winding jumper & carriage from site to store.
Body and neutral earthing of Power Transformer/05/08/10 MVA VCB, 250/400 KVA T/F installed by digging of pit up to water level depth (approx. 100’) and then inserting 1-1/4" dia G.I. pipe of of "B" grade, conforming to the requirement of IS specification and then connecting the top of the inserted pipe and transformer body through GI strip of size 50x6 mm with the help of nut and bolt or through gas welding, as per direction of supervising engineer including the cost of arrangement of all material, labourer, T&P, carrier etc. required for proper completion of work.
Safe Cartage of 11 KV VCBs from Store Center to site of work.
Dismentelling of old 11 KV OCBs after opening its 11 KV cable connection removing earthing bus bar CTs and taking it out side switch yard.
Erection and installation of 11 KV VCBs including all labour out going incoming connection with bus bar 11 KV cable boxes tapping with empire Tape & H.T. Tape and connecting with earthing.
Earthing of 11 KV VCBs providing & laying M.S. earth strip 50x6 mm including welding bending etc.
Safe carriage of damaged 11 KV VCBs from site of work to Store, Lal Diggi, Aligarh including loading & unloading at both ends.
Providing sundry items such as Lugs, Tape, G.I. Nuts Bolts & washers etc. required for proper completion of work.
Dismentling of 11 KV cable, 33 KV jumphers & neutral body, earthing from 5/8/10 MVA damaged T/F and then its removing from the plinth by dragging inside switchyard at site of work.
Safe dragging of 5/8/10 MVA damaged T/F from inside switchyard to outside switchyard at site of work.
Carriage of empty drums for filling of T/F oil of 5/8/10 MVA T/F at 33/11 KV S/Ss including loading & unloading at both ends at site of work.
Draining out the complete oil from the radiator of 5/8/10 MVA T/F and its filling into the drums at site of work.
After placement of 5/8/10 MVA T/F on the plinth its erection by assembling of radiators, conservator tank, marshling box and filling of T/F oil upto the mark and connecting of 33 KV jumphers and 11 KV cable at site of work.
Fabrication & erection of cable jumpher by 65x65x6 mm M.S. angle and 35x6 mm M.S. strip and fixing it at approximats place.
Carriage of T/F oil filled drums from site to Store Center, Aligarh including loading & unloading at both ends.
Digging of proper size of pit for following work of damaged steel support with the provision of temporary support :- Then reinforcement of steel support by welding of 4 Nos. 2 feet long M.S. angle iron of 50x50x6 mm. at equal distance around each pole/rail & also welding of these angle iron with each other by providing M.S. flat of size 35x6 mm. in round. After this construction of round plinth of pole will be done with cement, sand and concrete in 1:3:6 ratio of size 450 mm dia & 600mm height (300 mm under the ground+300 mm. above the ground). The plinth should be plastered with ½ inch thick cement and sand of ratio 1:4 & taper rounding the upper most part of the plinth. The rate will include all cost of material, labour and T&P etc, for completion of the above work which will be provided by the contractor at his own cost.
M/s Shree Krishna Enterprises,
BINNY ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .