Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹2.5 L
EMD Value
₹5,000
Closing Date
25 Nov 2025, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GENERAL MANAGER
THE KISAN COOP SUGAR FACTORY LTD SARSAWA
FABRICATION WORK
2025_TKCSF_1091673_1
FABRICATION WORK
Open Tender
Miscellaneous Works
Fixed-rate
30 days
THE KISAN COOP SUGAR FACTORY LTD SARSAWA
Please refer Tender documents.
3 documents required · 3 mandatory
₹250
THE KISAN COOP SUGAR FACTORY LTD SARSAWA
₹5,000
Yes
25 Nov 2025
18 Nov 2025
26 Nov 2025
18 Nov 2025
25 Nov 2025
18 Nov 2025
18 Nov 2025 - 25 Nov 2025
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: THE KISAN CO_OPERATIVE SUGAR FACTORY LTD,. SARSAWA (SAHARANPUR)
Name of Work: MILL & BOILER HOUSE,BOILING HOUSE AND ETP FABRICATION AND ERECTION WORK
Contract No: THE KCSF LTD,. SARSAWA/2025-26
Name of the Bidder/ Bidding Firm / Company :
Sl. No. 1 Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Packing & Forwarding in (Rs.) Insurance Charges in (Rs.) Freight Charges ( Unloading & Stacking) GST in (Rs.) Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
1 fey gkWÅl ,oa ckW;yj ij djk;s tkus oky dk;Z dk fooj.k ¼ykV&1½ 1 1 Construction of chamber for 100mm sluices valve item1 10 1 Nos
1.01 vkbZ0vkj0lh0 dh lkbZM IysV ij yxs Vsy ,.M LizksdsV ds Iyecj CykWd dks fQV dj larks’ktud Vªk;y nsus dk dk;ZA 1.01 1 izfr vnn 100 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
1.02 vkbZ0vkj0lh0 ds jSdks dks fn;s gq;s lSEiy vFkok MªkbZx vuqlkj rS;kj dj larks’ktud Vªk;y nsus dk dk;ZA 1.02 1 izfr vnn 100 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
1.03 Vh0vkj0ih0,Q0 ds ckWVe@VkWi >qds gq;s doj dks fjis;j dj larks’ktud Vªk;y nsus dk dk;ZA 1.03 1 izfr vnn 10 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
1.04 ¶ykbZ ,s”k ,jsLVj esa yxh o¶y IysV dks dkVdj gVkuk rFkk nh xbZ ubZ IysV yxkuk ,oa larks’ktud Vªk;y nsukA 1.04 1 izfr vnn 10 Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
1.05 ckW;yj ds 'kk¶VÇux IykaV ds ekWfMfQds'ku dk;Z gsrq VSadks dh detksj IysV dks uà IysV ls cnydj fjis;j djuk rFkk lEcfUèkr detksj ikÃi ykÃuks dks uà ikÃi ykÃu ls cnyuk rFkk ekWfMfQds'ku ds vuqlkj ikÃi ykÃus yxkuk] okYo vkfn dks fQV dj larks"ktud Vªk;y nsukA 1.05 1 izfr vnn 100 Excess(+) Full Conversion INR
1.06 Cok;fyax gkWÅl ij djk;s tkus oky dk;Z dk fooj.k ¼ykV&2½ 1.06 1 - 100 Excess(+) Full Conversion INR
1.07 twl lYQkbZVj ds detksj “kSy dks dkVdj nh gqbZ 6@8 ,e0,e0 dh IysV ls cnyus dk dk;Z dj fyd izqQ ,oa larks’ktud Vªk;y nsukA 1.07 1 izfr ehVj 100 Excess(+) Full Conversion INR
1.08 ykbZe Lysdj dh fjax dks LVªSfUFkfuax dj larks’ktud Vªk;y nsus dk dk;ZA 1.08 1 izfr vnn 100 Excess(+) Full Conversion INR
1.09 Mksj ds dEikVZesaV dh vkeZ dks dkVdj gVkuk ,oa fn;s gq;s ikbZi ls QSczhdsV djds yxkdj larks’ktud Vªk;y nsus dk dk;ZA 1.09 1 izfr vnn 100 Excess(+) Full Conversion INR
1.1 Mksj dh xyh gq;h ckWVe dks.k dks dkVdj gVkuk rFkk nh gq;h 10@12 ,e0,e0 dh IysV ls u;k cukdj fQV djus dk dk;ZA 1.1 1 izfr vnn 100 Excess(+) Full Conversion INR
1.11 ykbZe Lysdj ds gkWij dks u;k QSczhdsV djds fQV dj larks’ktud Vªk;y nsus dk dk;ZA 1.11 1 izfr vnn 100 Excess(+) Full Conversion INR
1.12 Mksj ds izR;sd dEikVZesaV ds LØsijks dks fjis;j dj larks’ktud Vªk;y nsus dk dk;ZA 1.12 1 izfr vnn 100 Excess(+) Full Conversion INR
1.13 batsD”ku iEi ua0&02 ds fMyhojh ykbZu ds cS.M dks csl lfgr QSczhdsV dj fQV dj fyd izqQ larks’ktud Vªk;y nsus dk dk;ZA 1.13 1 izfr vnn 100 Excess(+) Full Conversion INR
1.14 1750 cSp VkbZi e”khu dh ckWMh es xyh gqbZ fjax dks dkVdj gVkuk ,oa nh gqbZ ,l-,l- IysV ls ubZ fjax yxkdj larks’ktud Vªk;y nsus dk dk;ZA 1.14 1 izfr vnn 100 Excess(+) Full Conversion INR
1.15 dkWUVhU;w,l e”khu ds eksykfll pSEcj dh vkÅVysV ikbZi dks fjis;j dj larks’ktud Vªk;y nsus dk dk;ZA 1.15 1 izfr vnn 100 Excess(+) Full Conversion INR
1.16 fØLVykbZtj ds ÝaV ,oa cSd doj ds detksj ,oa {kfrxzLr fgLls dks nh x;h 8@10@12 ,e0,e0 dh IysV ls isfpax dj fyd izqQ ,oa larks’ktud Vªk;y nsus dk dk;ZA 1.16 1 izfr oxZ ehVj 100 Excess(+) Full Conversion INR
1.17 eSLdqV ,oa eksykfll xVj dh detksj ,oa {kfrxzLr fgLls dks dkVdj nh x;h 6@8 ,e0,e0 dh IysV ls cnydj fyd izqQ larks’ktud Vªk;y nsus dk dk;ZA 1.17 1 izfr oxZ ehVj 100 Excess(+) Full Conversion INR
1.18 iSu dUMsU”kj dh oSUp;wjh dks fMLesaVy dj nh gqbZ IysV ls QSczhdsV dj ¼¶ysat lfgr½ QSczhdsV dj fQV dj fyd izqQ Vªk;y nsukA 1.18 1 izfr vnn 100 Excess(+) Full Conversion INR
1.19 nh gqbZ 12 bap ,e0,e0 ikbZi ls QSczhdsV dj] ikbZi ykbZu ds iqjkus cS.M dks fMLesaVy dj fQV dj fyd izqQ larks’ktud Vªk;y nsukA 1.19 1 izfr vnn 100 Excess(+) Full Conversion INR
1.2 Cok;fyax gkWÅl esa LFkkfir vksojgsM VSad ds vksoj¶yks gks jgs ikuh dh ikbZi ykbZu ds ikl iEi LFkkfir djuk ,oa leLr dusD”ku djuk rFkk ;w0th0vkj0 ds ikl yxs nksuks dwfyax VkWoj ds ikl rd ikbZi ykbZu ¼3** lkbZt½ ds detksj ikbZi dks cnyuk rFkk funsZ”kkuqlkj iEi LFkkfir dj leLr dusD”ku djuk ,oa larks’ktud Vªk;y nsukA 1.2 1 yele 100 Excess(+) Full Conversion INR
1.21 DysjhQk;j ds uhps ds dEikVZesaV dh Vªs dks txg&txg ls fydst dks osfYMax }kjk ejEer djuk rFkk larks’ktud Vªk;y nsukA 1.21 1 izfr vnn 100 Excess(+) Full Conversion INR
1.22 lsUVªh¶;wxy gkWÅl ij LFkkfir ,;j dEizslj ls fey gkWÅl ,oa dsu dSfj;j dk lsisjsV ikbZi&ykbZu yxkuk rFkk fyd izqQ larks’ktud Vªk;y nsukA 1.22 1 yele 100 Excess(+) Full Conversion INR
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select
Quoted Rate in Words
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.03 MB
Tendernotice_2.pdf
PDF • 0.09 MB
BOQ_2005526.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .