Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-AOC | ₹42.4 L Quoted ₹43.7 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹44.5 LRejected-Finance NO 07 MOOGAMBIKAI AVENUE BEHIND HOINA HOSTEL KANNADAPALAYAM THIRUNINRAVUR CHENNAI 602 024 | CHENNAI | THIRUVALLUR | TAMIL NADU | 602024 | ₹44.5 L | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹45.4 LRejected-Finance DOOR NO 2 561 BEHIND HOINA HOSTEL MOOGAMBIKA NAGAR PERIYAPALAYAM ROAD THIRUNINRAVUR CHENNAI 602 024 | CHENNAI | THIRUVALLUR | TAMIL NADU | 602024 | ₹45.4 L | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹47.2 LRejected-Finance 2 755 ELAIYATHAMMAN KOIL MAIN ROAD BHARADHI NAGAR PTMS IAF POST AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | ₹47.2 L | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹47.6 LRejected-Finance NO 3 PERIYAR STREET ANAIKATTUCHERI PATTABIRAM CHENNAI 600 072 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600072 | ₹47.6 L | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Mariammal Constructions L6 | prabhakaran L1 | G HARI ELECTRICALS L4 | M RAMANAIAH L3 | Shri Varaghaa L5 | JANANIKARTHIK ENTERPRISES L7 | SAI SRI HARSHA ENTERPRISES L2 | muthu constructions L8 | SAMYDOSS CONSTRUCTIONS L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for carrying out complete waterproofing treatment to roof surfaces including complete removal of existing waterproofing treatment of any description including PCC in any position, cleaning the surface by wire brushing and washing and disposal of debris to a distance not exceeding 1500 m, preparation of surface by removing all loose particles, applying a coat of water based bituminous primer @ 0.40 litre per sqm and applying a uniform coat of hot blown bitumen of grade VG-10 @ 1.20 kg per sqm conforming to IS 702, providing PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) 25 mm thick as levelling course, forming cement concrete kerbs/mud stops, rendering 10 mm thick in cement mortar 1:3 finished even and smooth, and laying APP modified polymeric waterproofing membrane conforming to IS 16540/IS 16532, minimum 3 mm thick and weighing not less than 3.5 kg/sqm, reinforced with polyester non-woven fabric (minimum 150 gsm), laid with minimum 100 mm overlaps and fixed by torch application, including sealing of joints and edges, and finishing the surface with solar reflective aluminium paint @ 0.10 litre per sqm complete all as per manufacturer’s instructions and as specified and directed. Note : a)The rate quoted shall include all materials, labour, scaffolding, surface preparation, overlaps, wastage and complete waterproofing system. Nothing extra shall be paid. b) Integral waterproofing compound (WPC) shall be measured and paid separately under relevant item of BOQ. | 1,000 | Sqm | 1,200 ₹12,00,000 | 1,050 ₹10,50,000 | 1,200 ₹12,00,000 | 1,150 ₹11,50,000 | 1,300 ₹13,00,000 | 999 ₹9,99,000 | 1,399 ₹13,99,000 | 1,400 ₹14,00,000 | 1,500 ₹15,00,000 |
| 2.00 | Supply only integral water proofing liquid complete all as specified and directed. (@200ml per bag of cement) | 50 | ltr | 100 ₹5,000 | 100 ₹5,000 | 120 ₹6,000 | 100 ₹5,000 | 100 ₹5,000 | 120 ₹6,000 | 99 ₹4,950 | 100 ₹5,000 | 125 ₹6,250 |
| 3.00 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position capacaity 500 litres (Cleaning repairing, etc. measured separately) complete all as specified and directed | 10 | Each | 500 ₹5,000 | 500 ₹5,000 | 450 ₹4,500 | 250 ₹2,500 | 500 ₹5,000 | 450 ₹4,500 | 299 ₹2,990 | 500 ₹5,000 | 500 ₹5,000 |
| 4.00 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position capacaity 1000 litres (Cleaning repairing, etc. measured separately) complete all as specified and directed | 10 | Each | 600 ₹6,000 | 600 ₹6,000 | 500 ₹5,000 | 250 ₹2,500 | 500 ₹5,000 | 750 ₹7,500 | 349 ₹3,490 | 500 ₹5,000 | 500 ₹5,000 |
| 5.00 | S&F rotational moulded polyethylene water storage tank of 1000 litres capacity (triple layer) cylindrical vertical with closed top, conforming to IS 12701, of approved make, hoisted and fixed in position including providing and fixing inlet, outlet, overflow and washout connections with suitable fittings, complete all as specified and directed | 10 | Each | 12,000 ₹1,20,000 | 12,000 ₹1,20,000 | 11,000 ₹1,10,000 | 12,000 ₹1,20,000 | 12,000 ₹1,20,000 | 15,000 ₹1,50,000 | 11,000 ₹1,10,000 | 12,000 ₹1,20,000 | 11,500 ₹1,15,000 |
| 6.00 | S&F rotational moulded polyethylene water storage tank of 500 litres capacity (triple layer) cylindrical vertical with closed top, conforming to IS 12701, of approved make, hoisted and fixed in position including providing and fixing inlet, outlet, overflow and washout connections with suitable fittings, complete all as specified and directed | 10 | Each | 6,000 ₹60,000 | 6,000 ₹60,000 | 6,000 ₹60,000 | 6,200 ₹62,000 | 6,000 ₹60,000 | 7,000 ₹70,000 | 5,999 ₹59,990 | 6,000 ₹60,000 | 6,200 ₹62,000 |
| 7.00 | S&F in repairs ball valves, high pressure, with of PTMT with epoxy coated aluminium rod & high desity plastic ball screwed for iron pipe of 25 mm bore (Minimum weight 455 gms )and fixed complete all as specified and directed. | 20 | Each | 1,000 ₹20,000 | 800 ₹16,000 | 900 ₹18,000 | 925 ₹18,500 | 1,200 ₹24,000 | 850 ₹17,000 | 699 ₹13,980 | 1,000 ₹20,000 | 1,200 ₹24,000 |
| 8.00 | S&F in repairs 20mm dia of gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed. | 20 | Each | 1,500 ₹30,000 | 1,300 ₹26,000 | 1,500 ₹30,000 | 1,555 ₹31,100 | 1,400 ₹28,000 | 950 ₹19,000 | 1,499 ₹29,980 | 1,500 ₹30,000 | 1,500 ₹30,000 |
| 9.00 | Taking up or down steel tubing and connections, including removal to store etc complete all as specified and directed for 20 mm bore | 50 | RM | 50 ₹2,500 | 50 ₹2,500 | 50 ₹2,500 | 25 ₹1,250 | 50 ₹2,500 | 25 ₹1,250 | 25 ₹1,250 | 50 ₹2,500 | 50 ₹2,500 |
| 10.00 | Taking up or down steel tubing and connections, including removal to store etc complete all as specified and directed for 25 mm bore | 50 | RM | 60 ₹3,000 | 60 ₹3,000 | 60 ₹3,000 | 25 ₹1,250 | 50 ₹2,500 | 35 ₹1,750 | 25 ₹1,250 | 50 ₹2,500 | 50 ₹2,500 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
6 May 2026, 6:00 pmClosed
Garrison Engineer, Avadi
GE Avadi
REPAIR TO FALSE CEILING, ROOF SHEETS, VALLEY GUTTERS, RAIN WATER PIPE, RCC ROOF, PLASTERING, FLOOR / WALL TILING ETC TO CERTAIN BUILDING AT 23 ED AF STN AVADI
2026_MES_760954_1
8392/E8
Open Tender
Civil Works
270 days
GE Avadi
As per tender documents
7 documents required · 7 mandatory
₹500
GE Avadi
₹90,000
Yes
30 Jun 2026
18 Apr 2026
8 May 2026
18 Apr 2026
6 May 2026
30 Apr 2026
18 Apr 2026 - 23 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | M&L for carrying out complete waterproofing treatment to roof surfaces including complete removal of existing waterproofing treatment of any description including PCC in any position, cleaning the surface by wire brushing and washing and disposal of debris to a distance not exceeding 1500 m, preparation of surface by removing all loose particles, applying a coat of water based bituminous primer @ 0.40 litre per sqm and applying a uniform coat of hot blown bitumen of grade VG-10 @ 1.20 kg per sqm conforming to IS 702, providing PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) 25 mm thick as levelling course, forming cement concrete kerbs/mud stops, rendering 10 mm thick in cement mortar 1:3 finished even and smooth, and laying APP modified polymeric waterproofing membrane conforming to IS 16540/IS 16532, minimum 3 mm thick and weighing not less than 3.5 kg/sqm, reinforced with polyester non-woven fabric (minimum 150 gsm), laid with minimum 100 mm overlaps and fixed by torch application, including sealing of joints and edges, and finishing the surface with solar reflective aluminium paint @ 0.10 litre per sqm complete all as per manufacturer’s instructions and as specified and directed. Note : a)The rate quoted shall include all materials, labour, scaffolding, surface preparation, overlaps, wastage and complete waterproofing system. Nothing extra shall be paid. b) Integral waterproofing compound (WPC) shall be measured and paid separately under relevant item of BOQ. | 1,000 | Sqm | - | - |
| - | Supply only integral water proofing liquid complete all as specified and directed. (@200ml per bag of cement) | 50 | ltr | - | - |
| - | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position capacaity 500 litres (Cleaning repairing, etc. measured separately) complete all as specified and directed | 10 | Each | - | - |
| - | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position capacaity 1000 litres (Cleaning repairing, etc. measured separately) complete all as specified and directed | 10 | Each | - | - |
| - | S&F rotational moulded polyethylene water storage tank of 1000 litres capacity (triple layer) cylindrical vertical with closed top, conforming to IS 12701, of approved make, hoisted and fixed in position including providing and fixing inlet, outlet, overflow and washout connections with suitable fittings, complete all as specified and directed | 10 | Each | - | - |
| - | S&F rotational moulded polyethylene water storage tank of 500 litres capacity (triple layer) cylindrical vertical with closed top, conforming to IS 12701, of approved make, hoisted and fixed in position including providing and fixing inlet, outlet, overflow and washout connections with suitable fittings, complete all as specified and directed | 10 | Each | - | - |
| - | S&F in repairs ball valves, high pressure, with of PTMT with epoxy coated aluminium rod & high desity plastic ball screwed for iron pipe of 25 mm bore (Minimum weight 455 gms )and fixed complete all as specified and directed. | 20 | Each | - | - |
| - | S&F in repairs 20mm dia of gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed. | 20 | Each | - | - |
| - | Taking up or down steel tubing and connections, including removal to store etc complete all as specified and directed for 20 mm bore | 50 | RM | - | - |
| - | Taking up or down steel tubing and connections, including removal to store etc complete all as specified and directed for 25 mm bore | 50 | RM | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
8392TENDERDOCU.pdf
Tender Documents • 1.09 MB
BOQ_852374.xls
BOQ • 4.47 MB
Download all tender documents and submit your bid