Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC 191 378 PRATAP NAGAR KHUMBHA MARG SANGANER JAIPUR | JAIPUR | JAIPUR | RAJASTHAN | L1 | Accepted-AOC Lowest | |
| 2 | L2₹11.4 L+₹8,529.54 (0.75%)Rejected-Finance 111 90 VIJAY PATH MANSAROVAR JAIPUR RAJASTHAN 302020 | JAIPUR | RAJASTHAN | 302020 | L2 | Rejected-Finance Second Lowest | |
| 3 | L3₹13.3 L+₹1.9 L (16.9%)Rejected-Finance BACHRA RAY KHALARI RANCHI JHARKHAND 829210 | RAY | RANCHI | JHARKHAND | 829210 | L3 | Rejected-Finance Highest | |
| 4 | L4₹14.3 L+₹3.0 L (26.2%)Rejected-Finance ANAND NAGAR CHHABRA 325220 | CHHABRA | BARAN | RAJASTHAN | 325220 | L4 | Rejected-Finance Highest | |
| 5 | L5₹15.5 L+₹4.2 L (36.6%)Rejected-Finance 14 9 SWARN PATH MANSAROVAR JAIPUR | JAIPUR | JAIPUR | RAJASTHAN | 302020 | L5 | Rejected-Finance Highest |
Tender Value
₹18.9 L
EMD Value
₹18,940
Closing Date
24 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
RE Electrical RHB
Resident Engineer Electrical Rajasthan Housing Board Jaipur
Installation and fixing of new high mast lights and street lights on sector 5 I G Nagar Jaipur
2022_RHBCE_254483_1
RE-Electrical_02/2021-22
Open Tender
Electrical Works
Percentage
180 days
Jaipur
As per NIT
2 documents required · 2 mandatory
₹1,180
As per NIT
₹18,940
Yes
3 Nov 2023
13 Jan 2022
25 Jan 2022
13 Jan 2022
24 Jan 2022
13 Jan 2022
20 days
Amount
P & F of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM 6/ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
60 watt LED Street Light fixture
Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
High Power LED Flood Light 200W
Bidder Name
Amount
PUNIT ENTERPRISES(GSTN-08AFAPB2034C1ZE)
Shree Vinayak Electricals(GSTN-08AEHPG6703K1ZF)
Raj Electricals(GSTN-08AGBPS1419A1ZV)
M/S Jindal Electricals(GSTN-08AEJPJ5458A1ZL)
Shree Ram Electricals(GSTN-08AJVPM9530B1ZW)
Shree Vinayak Electricals
Shree Ram Electricals
Raj Electricals
PUNIT ENTERPRISES
M/S Jindal Electricals
Shree Ram Electricals
PUNIT ENTERPRISES
Raj Electricals
technical_453627.pdf
PDF • 0.33 MB
techsummary_453627.pdf
PDF • 0.33 MB
finance_453627.pdf
PDF • 0.33 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_453627.pdf
PDF • 0.34 MB
914_08-02-22.pdf
PDF • 3.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .