| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC | ₹2.4 Cr | L1 | Accepted-AOC Award of contract |
| 2 | L2₹2.6 Cr+₹13.4 L (5.51%)Rejected-Finance | ₹2.6 Cr+₹13.4 L (5.51%) | L2 | Rejected-Finance Being other than lowest bidder |
| 3 | L3₹2.7 Cr+₹30.1 L (12.4%)Rejected-Finance | ₹2.7 Cr+₹30.1 L (12.4%) | L3 | Rejected-Finance Being other than lowest bidder |
| 4 | L4₹2.9 Cr+₹48.8 L (20.1%)Rejected-Finance 401 SHASTRI NAGAR JAMMU 180004 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180004 | ₹2.9 Cr+₹48.8 L (20.1%) | L4 | Rejected-Finance Being other than lowest bidder |
Tender Value
₹2.4 Cr
EMD Value
₹3.2 L
Closing Date
5 Jun 2023, 6:00 pmClosed
Cheif Engineer Udhampur Zone
HQ CE AF Udhampur Zone
CA NO CEAFU-03-2023-24 ADDITIONAL / ALTERATION / IMPROVEMENT TO CERTAIN OMQs AND SMQs AT AF STN JAMMU
2023_MES_589623_1
CEAFU-03/2023-24
Open Tender
Civil Works
Item Rate
366 days
Jammu
As per tender documents and as per policy in vogue
9 documents required · 9 mandatory
₹2,000
GE AF Jammu
₹3.2 L
Yes
HQ CE AF Udhampur Zone
20 Jul 2023
15 Apr 2023
13 Jun 2023
15 Apr 2023
5 Jun 2023
22 May 2023
15 Apr 2023 - 22 Apr 2023
28 Apr 2023
Amount
SCHEDULE 'A' PART-I (ADDN/ALTN BUILDING WORK/EXTERNAL WATER SUPPLY WORK)
Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-Charge. (For building work and Path work also)
Demolition of reinforced cement concrete of any description and in any position not other wise specifically provided for complete all as specified and as directed by Engineer-in-Charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles/concrete block walling complete all as specified and as directed by Engineer-in-Charge.
Demolition of unreinforced cement concrete exceeding 15cm thickness (above ground floors) complete all as specified and as directed by Engineer-in-Charge.
Removing of building materials/demolished materials by manual or mechanically including demolished material from site and to be removed outside defence area distance exceeding 1.00km but not exceeding 5.00Km to be dumped at a place approved by state govt for the same purpose complete all as specified and as directed. The rates of loading, unloading, transportation of material to be removed is deemed to be included in overall rates quoted by the bidder against this item and nothing extra shall be paid on this account
Taking down cement plaster built in cement mortar, of any description on brick or stone walls, to any thickness (including any number of layers of plaster/overlapping of tiles/mosic wall finishes) including racking out joints, hacking for keys, scrubbing down with water, removing dust, debries/rubish etc. complete all as specified and as directed. Note: Contractor shall have no claim what so ever expenditure incurred at site in respect of thickness of plaster.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt), complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt), complete all as specified and directed by Engineer-in-Charge.
Taking down Shutters of any description exceeding 1.00 square metre but not exceeding 2.00 square metre each complete all as specified and as directed.
Dismantling stone slab and tiles of any description or thickness in floor or kitchen slab laid, bedded and pointed in any type of mortar complete all as specified and as directed by Engineer-in-Charge.
Material and labour for plain cement concrete 1:5:10, type E-2 using 40mm graded crushed stone aggregates, as in foundation filling, mass concrete, in sunken floors and the like complete all as specified and as directed.
Material and labour for 75mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base, floors, pavings and the like including finishing the surface even and fair complete all as specified and as directed.
Material and labour for form work to chullah hoods, chajjas, troughs and similar items including edges, not exceeding 200mm thick, with rough finished flat surface of concrete complete all as specified and as directed.
Material and labour for rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces mixed with integral water proofing compound including finishing the surface even and smooth without using extra cement complete all as specified and as directed. NOTE: Water proofing compound shall be measured and paid separately as "Supply only" under relevant item of this BOQ.
Material and labour for rendering 15mm thick in cement 1:6 on fair faces of brick work or concrete surfaces including finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or over roof concrete surfaces mixed with integral water proofing compound including finishing the surfaces even & smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound shall be measured and paid separately as "Supply only" under relevant item of this BOQ.
Material and labour for rendering 5mm thick in cement mortar 1:3 as in ceiling, chajjas, roof projection, facias and the like of concrete surfaces including finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 15 mm thick screed bed or bedding layer in cement mortar 1:4 including finishing the surface even and rough for laying floor finishes/floor tiles complete all as specified and as directed.
Material and labour for joint free Non-Skid coloured Ceramic, first quality, tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 square metre but not exceeding 0.18 square metre, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
Material and labour for joint free Non-Skid coloured Ceramic, first quality, tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 square metre but not exceeding 0.18 square metre, in vertical surfaces of wall such as skirting, dado and the like, inclduing cutting of tiles to required size, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
Material and labour for 450mm x 300mm x 7mm thick, coloured glazed ceramic tiles, first quality, on vertical surfaces, set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments. (Note: Any disturbed surfaces shall be matched with existing surface without any extra cost to the govt) complete all as specified and as directed.
Material and labour for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 including finishing the surfaces even and rough for wall tiles/finishes complete all as specified and as directed.
Material and labour for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate including finishing the surfaces even and rough for leveling course including WPC complete all as specified and as directed. NOTE: Water proofing compound shall be measured and paid separately as "Supply only" under relevant item of this BOQ.
Material and labour for cement concrete 1:3:6 type C-1 using 20mm graded stone crushed aggregate in plinth protection, 75mm thick, finished even and fair without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with and including bitumen and sand of ratio 1:3 by weight complete all as specified and as directed.
Material and labour for 40mm thick PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates, as in flooring inclduing finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour for RCC M-25 design mix using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, in shelves, roof projection, etc, and finishing exposed surfaces fair & even complete all as specified and as directed.
Material and labour for brick work with sub class 'B' bricks straight or curved on plan exceeding 6.00m mean radius built in cement mortor 1:6 complete all as specified and as directed.
Material and labour for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed.
Material and labour for post construction anti-termite treatment by providing and injecting at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 50mm centre to centre and sealing the same complete all as specified and as directed.
Material and labour for post construction anti termite treatment of soil under existing floors using emulsion at the rate of one litre per hole 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match with the existing floors all as specified and as directed by Engineer-in-Charge.
Material and labour for machine cut mirror polished kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Supply only integral water proofing compound ISI marked complete all as specified and as directed.
Material and labour for pre-polished granite work 16 to 18mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with marble shade of makrana white over 15 mm thick Screed in cement mortar 1:4 complete all as specified and as directed.
Material and labour for 18-20 mm thick pre- polished granite slab machine cut of any shade as approved by GE, laid over cement screed bed including cutting and nosing with suitable hole for cylinder gas pipe, grinding and mirror polishing (Granite finish) with suitable grinding stones set in cement mortar 1:4 in single piece for cooking platform and the like complete all as specified and as directed.
Material and labour for rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as specified and as directed.
Material and labour for pressed steel frames (Factory made) made out of 1.25mm thick mild steel black sheet for doors, with double rebates including necessary fixing lugs, butt hinges, lock strike plate, etc complete, size of frame 125 x 60mm including one shop coat of red oxide zinc chrome primer, including bottom of each chowkat to be welded with 2 Nos 25 x 25 x 3mm thick flat iron projecting 10 cm on either side and back fill to chowkahts with PCC 1:3:6 type C-0 using 12.5mm graded crushed stone aggregate after applying and including one coat of black paint to prevent from corrosion complete all as specified and as directed by Engr-in-Charge.
Material and labour for pressed steel frames (Factory made) made out of 1.25mm thick mm black MS sheet for doors, with one or more rebates including necessary fixing lugs, butt hinges, lock strike plate, etc complete, size of frame size 105 x 60mm including one shop coat of red oxide zinc chrome primer,inclding bottom of each chowkat to be welded with 2 Nos 25 x 25 x 3mm thick flat iron projecting 10 cm on either side and back fill to chowkahts with PCC 1:3:6 type C-0 using 12.5mm graded crushed stone aggregate after applying and including one coat of black paint to prevent from corrosion complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 35mm flush shutters factory made, solid core construction, with block board core and plywood face panels, commercial type on both sides, including both faces covered with pre-laminated both side with decorative choice laminations complete with lipping/frame to match complete all as specified and as directed.
Material and labour for 2nd class hard wood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed.
Material and labour for anodised aluminium window powder coated and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 75mm long (2 no.) suitable handle (1 no) including glazing suitable for fixing of 5mm thick plain sheet glass and stainless steel wire mesh complete all as specified. Note: 5mm thick sheet glass and stainless steel wire mesh shall be measured and paid separately as "Supply and fixing" under relevant item of this BOQ.
Material and labour for anodised aluminium powder coated window with glazed and wire mesh shutter sliding aluminium open three track section having specific size of style ,top rails and bottom rails including anodised aluminium frame incl necessary joining cleats, glazing clips rubber packing, anodised aluminium snap beading screws, anodised aluminium fittings complete and including glazing by using 5mm thick plain sheet glass and stainless steel wire mesh of dia 0.36 mm and aperture 1.40 mm complete all as specified and as directed. Note: 1. 5mm thick sheet glass and stainless steel wire mesh shall be measured and paid separately as "Supply and fixing" under relevant item of this BOQ. 2. PVC rubber, EPDM rubber and sliding window lock shall be paid separately under relevant item of this BOQ.
Material and labour for PVC roller not exceeding 40mm dia fixed to aluminium sliding window shutter with necessay clip or screw etc complete all as specified and as directed.
Material and labour for EPDM rubber to aluminium window frame for fixing window glass etc complete all as specified and as directed.
Material and labour for sliding window lock consisting of aluminium body with PVC mail and female with necessary screw or fixing arrangement complete all as specified and as directed.
Material and labour for aluminium anodised powder coating grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-Charge.
Supply and fixing (to existing door frames) for 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer-in-Charge.
Material and labour for Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. Mild steel stay shall be provided at the bottom to steady the frame, complete as specified by the manufacturer and as per directions of Engineer-in-Charge
Supply and fixing for stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Material and labour for 5mm thick ordinary sheet glass and glazing, exceeding 0.5 Square Metre in each pane, fixed with oil putty or wooden beads or with EPDM rubber complete all as specified and as directed.
Material and labour for 5mm thick ordinary sheet glass and glazing, not exceeding 0.5 Square Metre in each pane with oil putty or wooden beads or with EPDM rubber complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with screws complete all as specified and as directed.
Material and labour for 2nd class hard wood exceeding 13 and not exceeeding 25 sqcm fillets, bull- nosed, splayed, chamfered or rounded on one edge or face, square, rectangular or triangular in section clean sawn, secured with nails complete all as specified and as directed.
Material and labour for 18/19 mm thick Prelaminated particle board, exterior grade, prelaminated both side deocrative choice lamination, fixed with screws to timber frame work fixed in repair complete all as specified and as directed.
Material and labour for 18/19 mm thick Prelaminated particle board, exterior grade, prelaminated one side with deocrative choice lamination & other side balancing white lamination, fixed with screws to timber frame work fixed in repair complete all as specified and as directed.
Material and labour for external teak wood lipping, 6mm thick fixed with nails suitable of 18/19mm thick block board or prelaminated particle board complete all as specified and as directed.
Material and labour for aluminium section of size 63.5mm x 38mm thick as in ventilator with one fixed frosted glass of 4mm thick size 450mm X 450mm and five No louvers frosted glass of size 450mm x 100 mm wide with necessary fitting and fixture and fixing arrangement all as specified and as directed by Engineer-in-Charge.
Material and labour for 30 mm width of flap Continous (Piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and as directed.
Material and labour for 40mm dia, brass cupboard knobs fixed with nut, screw and washer complete all as specified and as directed.
Material and labour for aluminium hasp and staple, 125mm safety type with mild steel hinge pin including bolt type complete all as specified and as directed.
Material and labour for 140mm ball catches with 8 mm dia steel ball and brass body and striking plate including letting in complete all as specified and as directed.
Material and labour for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
Material and labour for rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with & including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails & guides) & hanging; also fastening & fixing complete all as specified and as directed.
Material and labour for 2nd class hardwood small fitting such as brackets of any type,latch and hinge blocks, shaped door and window stops and the like including all necessary labours, articles not exceeding 200 cubic centimetre each complete all as specified and as directed.
Material and labour for 150 mm aluminium barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Material and labour for 200 mm aluminium, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Material and labour for 300 mm aluminium, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed complete all as specified and as directed.
Material and labour for mild steel 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
Material and labour for 150 mm aluminium handles, cast type, anodised complete all as specified and as directed.
Material and labour for 125 mm Aluminium handles, cast type, anodised complete all as specified and as directed.
Material and labour for 75 size stainless steel butt hinges complete all as specified and as directed
Material and labour for 100 size stainless steel butt hinges complete all as specified and as directed
Supply and fixing in repiars for stainless steel drapery rod, with pre coated PVC lamination of dia not less than 25mm with brackets on both end of rod and two nos globe on both ends for each door/windows brackets shall be at galvanised steel 1.6mm thick complete all as specified and as directed.
Material and labour for 150mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed.
Material and labour for 75 mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
Material and labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
Material and labour for mild steel TMT bars 6mm to 8mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Dismantling plain brick tiles or mangalore type or any other type 20 to 30mm thick from roof top including cement mortar bedding and roof treatment and existing PCC layer if any to any thickenss upto true slab level complete all as specified and as directed.
Material and labour for rendering 15mm thick in cement mortar 1:4, on concrete surfaces of roof inclduing finishing the surfaces even and fair without using extra cement for applying roof treament complete all as specified and as directed.
Material and labour for water proofing treatment on horizontal and vertical surface with polymeric water proofing membrane minimum weighing 3.0 kg/Square Metre and minimum 3mm thick reinforced with polyster non wave fabric (wt. not less than 150 gms/Square Metre) laid on primed surface by forced application complete all as specified laid over a coat of of bitumen primer @.30 Ltr/Square Metre with applying a coat of hot blown bitumen of 85/25 or 95/15 @ 1.20 Kg/Square Metre. APP membrance shall be laid by torching with 75mm overlap in longitudinal direction and 100mm overlap in transverse direction all as specified and as directed by Engineer-in-Charge.
Material and labour for Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) of approved make, with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement and marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and as directed.
Taking up or down steel tubing 15mm bore and connection including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down steel tubing 20mm bore and connection including cleaning for refixing or removal to store complete all as specified and as directed.
Material and labour for 16mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed. (For building work and external water supply)
Material and labour for 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed. (For building work and external water supply)
Material and labour for cutting chases, pinning in, making good to facing of brick wall where required and pointing in CM 1:3 to ends of edges of landing etc and cutting chases for concealed water tubing and making good, cutting exceeding 10 cm but nor exceeding 20 cm girth in brick waqll masonary complete all as specified and as directed.
Dismantaling of AC/ PVC drain pipes jointed in cement mortar and taking out from trenches or walls including fittings, of 100 mm dia complete all as specified and as directed.
Dismantaling of AC/ PVC drain pipes jointed in cement mortar and taking out from trenches or walls including fittings, of 75 mm dia complete all as specified and as directed.
Material and labour for PVC (SWR) floor trap 100mm dia of outlet, plain with grating including jointing with solvent cement fixed in repairs complete all as specified and as directed.
Material and labour for PVC (SWR) floor trap 75mm dia of outlet, plain with grating including jointing with solvent cement fixed in repairs complete all as specified and as directed.
Material and labour for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls bore of pipe 100 mm with PVC clamps and saddles complete all as specified and as directed.
Material and labour for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls bore of pipe 75 mm with PVC clamps and saddles complete all as specified and as directed.
Supply and fixing PVC (SWR) bends of any radius with access door for 110mm bore of pipe complete all as specified and as directed.
Supply and fixing PVC (SWR) bends of any radius with access door for 75 mm bore of pipe complete all as specified and as directed.
Supply and fixing PVC (SWR) reducers for 110mm bore of pipe complete all as specified and as directed.
Supply and fixing PVC (SWR) couplers bore of pipe 110 mm complete all as specified and as directed.
Supply and fixing PVC (SWR) junction single (single T) equal or unequal with access door for 110mm bore of pipe complete all as specified and as directed.
Supply and fixing PVC (SWR) junction single (single T) equal or unequal with access door for 75mm bore of pipe complete all as specified and as directed.
Supply and fixing 110mm bore PVC (SWR) vent cowl complete all as specified and as directed.
Supply and fixing 75mm bore PVC (SWR) vent cowl complete all as specified and as directed.
Supply and fixing PVC (SWR) branch piece, single (single Y) equal or unequal 100 mm dia complete all as specified and as directed.
Supply and fixing sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 610mm x 460mm bowl size 560mm x 410mm x 200mm and fixed in repairs complete all as specified and as directed.
Supply and fixing stainless steel plate rack 1mm thick & size 750mm x 600 mm x 250mm deep with plate racks, spoon holders, shelves etc complete all as specified and as directed.
Supply and fixing Vitreous China wash down water closet pan and seat cover (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including P or S trap and including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, including connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc., fixed in repairs complete all as specified and as directed. MAKE: CERA Cat Part No S1053105 P-Trap or Hindware Cat Part No 519010 (P-18) or ESSCO Cat Part No ECS-WHT-551 PNPP183LZ
Supply and fixing Heath faucet (ABS Body) mils steel CP sutabile for 15mm dia pipe with 1.25mtr long flexible tube and ABS wall hook including making connection and fixed in position complete all as specified and as directed.
Supply and fixing Vitreous china white wash hand basin corner type 'including CI/MS brackets including cutting for and pinning in brackets but excluding waste pipe, fixed in repair complete all as specified and as directed. MAKE: CERA Cat Part No S2040161 or Hindware Cat Part No 10031 or ESSCO Cat Part No ECS-WST-841
Supply and fixing 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with combiflush/twin flush provision, complete, fixed in repairs all as specified and as directed by Engr-in-Charge.
Supply and fixing 15mm dia of pipe bib taps cast copper alloy, fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs complete all as specified and as directed. MAKE: CERA Cat Part No F2013151 or Hindware Cat Part No F320004 or ESSCO Cat Part No-COS-103037
Supply and fixing 15mm dia of pipe angle valves, fancy type and chromium plated with long shank and cup screwed both ends for iron pipes or for Unions and fixed in repairs complete all as specified and as directed. MAKE: CERA Cat Part No F2013201 or Hindware Cat Part No F320006 or ESSCO Cat Part No-COS-103053
Supply and fixing 20 mm dia gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed in repairs complete all as specified and as directed.
Supply and fixing glass shelf 600mm long with and including chromium plated railing, brass screws and wooden/plastic cleats complete all as specified and as directed.
Supply and fixing brass chromium plated center hole mixer for hot and cold water with capstan heads, screwed downhigh pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipes 15 mm dia complete all as specified and as directed. MAKE: CERA Cat part No-QT F2006461 HT F3001461 or ESSCO Cat Part No MQT-CHR-516AKN or Equivalent in Kohler
Supply and fixing brass chromium plated mixer for sink for hot and cold water with capstan heads, screwed downhigh pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipes 15 mm dia complete all as specified and as directed. Make:- CERA Cat Part No- QT F 2006501 HT F 3001501 or ESSCO Cat Part No STE-CHR-107309 or Equivalent in Kohler
Supply and fixing brass chromium plated wall mixer 3 in 1 for hot and cold water with capstan heads, screwed downhigh pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipes 15 mm dia complete all as specified and as directed. MAKE: CERA Cat part no-QT F2006401 HT F3001401 or Jaquar Cat Part No FUS-CHR-29281 or Kohler Cat Part No 98754IN-4-CP
Supply and fixing PVC connection 15mm dia and 450mm long with two Nos of brass checknuts and washers and fixed in repairs complete all as specified and as directed.
Supply and fixing brass Chromium plated shower rose with or without swivel joints 125mm size including fixing to steel pipe or union and fixed in repairs complete all as specified and as directed. MAKE: CERA Cat Part No F-7020111AB or Hindware Cat Part No F160142 or ESSCO Cat Part No-EOS-542A
Supply and fixing PVC Mirror with cabinet shelf 450 x 600mm including screws and fixing on wall complete all as specified and as directed. Make: Paryag/Cera/Sant Gobin/Atul
Supply and fixing grating doom 125mm dia with waste hole of PTMT (Minimum weight 40 gms) complete all as specified and as directed.
Supply and fixing waste coupling of PTMT (half or full threaded) 32 mm dia complete all as specified and as directed.
Supply and fixing PVC waste pipe 32 mm dia flexible with cup to fit wash hand basin waste coupling complete all as specified and as directed.
Supply and fixing soap-dish chromium plated complete all as specified and as directed. Make: Jainko Cat part No SDJ-1 or ESSCO Cat Part No F880011 or Cera Cat Part No F5007906.
Supply and fixing corner type glass shelf (three peice) including steel rail complete all as specified and as directed. Make: Jainko Cat part No SDJ-3 or JAQUAR Cat Part No CAN-1173 or Cera Cat Part No F5005101
Supply and fixing stainless steel towel ring complete all as specified and as directed. Make: Jainko Cat part No TRD-1 or ESSCO Cat Part No AEC-1121N or Cera Cat Part No F5006106
Supply and fixing 600mm long tubular tower rail brass chromium plated 20mm dia, D type 60cm long fixed with two plugs (Gutties) of 2nd class hard wood embeded in cement mortor 1:3 with MS screws and fixed in repairs complete all as specified and as directed.
Dismantling water tanks and removing to store of capacity exceeding 250 but not exceeding 500 litres complete all as specified and as directed.
Supply and fixing rotational moulded polyethylene water storage tank, inner and out white, twe layers, ISI marked (cylinderical vertical with closed top) hoisted with threaded cap and fixed in position all as specified in SSR Part-I of Capacity 500 litres each including all accessories (i.e GI nipples, etc), including provn of 20/15mm dia spout for connecting inlet, outlet, overflow and washout pipes, complete all as specified and as directed by Engineer-in-Charge. Note: Weight of tank shall be as per relevant IS specifications)
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. & hositing if required reconnecting & re-fixing in position including Cleaning & removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc., of capacity exceeding 250 litre but not exceeding 500 litres complete all as specified and as directed.
Material and labour for preparation of new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over and including one coat of pink primer complete all as specified and directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment, washing rubbing down and stoping of painted surfaces and applying finishing walls with acrylic smooth exterior paint weather proof of required shade, New work (two or more coat) applied @ 1.67 ltr/10 Square Metre for each coat over and including one priming coat of exterior primer applied @ 2.20 kg/10 Square Metre complete all as specified and as directed. Note: 1. The work shall be done through authorised applicator of manufacturer. 2. Mou shall be signed between the contractor and company before execution of work.
Material and labour for preparation of newly plastered surfaces and finishing walls with acrylic smooth exterior paint weather proof of required shade : New work (Two or more coat applied @ 1.67 ltr/10 Square Metre over and including one priming coat of exterior primer applied @ 2.20 kg/10 Square Metre complete all as specified and as directed. Note: 1. The work shall be done through authorised applicator of manufacturer. 2. Mou shall be signed between the contractor and company before execution of work.
Material and labour for preparation of newly plastered surfaces of wall and distempering walls with two coats of washable oil bound distemper (white or tinted) over a coat of 3mm thick Birla white wall care putty, over a coat of primer as directed after washing/rubbing down and stopping of distempered and painted surfaces as in preparatory work to give uniform and smooth finish complete all as specified and as directed.
Material and labour for complete removal of existing treatment, washing rubbing down and stoping of painted surface and applying two coats of washable distemper oil bound distemper, white or tinted on wall surface including preparation of surface over a coat of 3mm thick wall putty as directed after washing/rubbing and stopping of distempered and painted surfaces as in preparatory work to give uniform and smooth finish complete all as specified and as directed.
Material and labour for complete removal of existing treatment, washing rubbing down and stoping of painted surface and applying two coats of washable distemper oil bound distemper , white or tinted on ceiling surface including preparation of surface over a coat of 3mm thick wall putty as directed after washing/rubbing and stopping of distempered and painted surfaces as in preparatory work to give uniform and smooth finish complete all as specified and as directed.
Material and labour for applying three coats of white wash, white or tinted on newly plastered surfaces of celling including preparation of surface complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Material and labour for preparation of new surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer in any tint complete all as specified and as directed.
Material and labour for cutting openings, through brick walls built in cement mortar or in cement lime mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and as directed.
Material and labour for forming jambs, in cement mortar 1:4 etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and as directed.
Material and labour for applying one coat of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of old painted surface complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc including brushing neat cement slurry with 3.0 kg of cement per square metre complete all as specified and as directed.
Supply and fixing stainless steel peg sets of 6 hooks over a base plate of stainless steel 4mm thick as approved by GE.
Taking down tar felt of existing water proofing treatment including cement mortar bedding upto true slab level complete all as specified and as directed.
Material and labour for applying a layer of WPC (PDIFIN 2K) as per manufacturer's direction from Dr Fixit or equal approved in Pidilite/Sikka, on top layer of RCC roof slab before application of bedding layer complete all as specified and as directed. Note: Cleaning of RCC roof shall be washing with water and shall be approved by GE.
SCHEDULE 'A' PARTI-II (INTERNAL ELECTRIFICATION WORK)
Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket or power)complete including fixture and fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings, wooden terminal boxes, plastic laminated sheet cover, including taking down of DB’s, meter board any type complete all as specified and as directed.
M & L for Point wiring for one light point controlled by one switch with 1.5 Sqmm PVC insulated and unsheathed FRLS-H copper conductor single core multi stranded flexible copper cable 1100 Volts grade conforming to IS-694 using approved colour code as per IS code drawn through non metallic rigid PVC heavy duty conduit in concealed (min 20mm dia external) but shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed with all accessories suitable for modular type fitment including provision for fixing of modular flush boxes of suitable size for fixing of modular switches/ sockets/ regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multi stranded copper conductor cable (green color) as continuous earth lead wire connected to common earth and earth dolly complete all as specified and directed by Engineer-in-Charge.
Description all as per srl item no.142.00 here-in-before but for one fan/exhaust fan and wall mounted fan point controlled by one SP switch complete all as specified and as directed.
Description all as per srl item no.142.00 here-in-before but for one light point controlled by two 2 way SP switches complete all as specified and as directed.
Description all as per srl item no.142.00 here-in-before but for one bell point controlled by one No bell push complete all as specified and as directed.
Description all as per srl item no.142.00 here-in-before but for one 3 pin 5 Amps socket out let point on the same board controlled by one switch complete all as specified and as directed by Engineer-in-Charge.
Description all as per srl item no.142.00 here-in-before but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size complete all as specified and as directed.
Description all as per srl item no.142.00 here-in-before but for one 3 pin socket out let, 16 Amps on Independent board with the cable 2.5 Sqmm size but earth wire 2.5 Sqmm complete all as specified and as directed.
Supply and fixing modular socket outlet 5 pin, 6 amps flush type complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing modular switch (piano) flush button single pole one way 6 amps 1 module with suitable plate and cover complete all as specified and as directed.
Supply and fixing modular Socket outlet flush universal (piano) type 6 pin 6/16 Amps with suitable plate and cover complete all as specified and as directed.
Supply and fixing modular switch (piano) flush button single pole one way 16 amps with suitable plate and cover complete all as specified and as directed.
Supply and fixing modular switch piano flush button type 6 amps single module two way complete all as specified and as directed.
Supply and fixing electric modular ding dong bell, 230 volt AC, single pole and fixed in repairs, complete, all as specified and as directed by Engr-in-Charge.
Supply and fixing modular bell push flush button type 5 amps single pole one way complete all as specified and as directed.
Supply and fixing ceiling rose surface bakelite 2 to 3 terminals 65 x 50mm complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing lamp holder, insulated body with back plate for batten fitting including LED bulb of 12 watt in white colour complete all as specified and as directed by Engineer-in-Charge
Supply and fixing LED batten surface / wall mounted with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <20W, luminaire lumen >2000 lm, system efficiency of > 120 lumens/W, LED Make : Nichia/ Cree/ Everlite / Eclison/ Osram/ Lumiled, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class 1, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficiency>85%, power factor > 0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50,000 burning hrs (min) as per L7O criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level < 60 V DC as per IEC standard with LM70 & LM 80 certification all as specified and as directed.
Supply and fixing LED Bulk Head type with high out put , 10 watt ,220 V AC,Color temperature 6500 K or as directed,Lumens 1000 lm with all accessories ,IP 65 protection dust and water resistant ,surge protection up to 2.5kV, PC opal high efficiency diffuser ,LM 80 tested made die cast aluminium housing with complete assembly, suitable for surface/wall mounted with driver holder including connecting up using 1.5 sqmm copper conductor multistarnd PVC insulated with three core flexible copper conductor cable of suitable size complete all as specified and as directed
Supply and fixing LED mirror light fitting /fixture surface / wall mounted with specially premium quality material with integrated LED designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired up to terminal block, power consumption <12W, lifetime upto 2500 hours with IP -20 class II protection 220-240 volts with total lumen ficture output of 420 with diffusing light effect with stylish heritage type looks and finish all as specified and as directed.
Supply and fixing sheet metal enclosures with socket plug top and 20 Amp MCB 240 Volts single pole and neutral enclosures with two pin and earth plug and socket complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Sub main wiring using PVC insulated and unsheathed fire retardant low smoke and halogen (FR-LSH) copper conductor single core multi stranded unsheathed copper cable 6.00 Sqmm (for Phase and neutral) and earth continuity conductor of size 6.00 Sqmm multistranded copper conductor FRLSH 1100 Volts conforming to IS:694 (2010) using approved colour code for phase and neutral as per IS code drawn through non-metallic PVC rigid concealed conduit, 20mm outer dia (ISI marked) heavy mechanical stress (HMS) grade in accordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thick. The external dia shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I (ISI marked) including conduit accessories like bends, tees, junction boxes etc fixed concealed with all accessories complete all as specified and as directed by Engineer-in-charge. Note 01: 2 runs of 6.00 Sqmm copper cable & 1 run of 6.00 Sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit. Note 02: The rate of cutting chases required for concealed conduit/flush boxes etc. is deemed to be included in overall rate quoted and nothing extra shall be paid for this.
Material and labour for Sub main wiring using PVC insulated and unsheathed fire retardant low smoke and halogen (FR-LSH) copper conductor single core multi stranded unsheathed copper cable 4.00 Sqmm (for Phase and neutral) and earth continuity conductor of size 4.00 Sqmm multistranded copper conductor FRLSH 1100 Volts conforming to IS:694 (2010) using approved colour code for phase and neutral as per IS code drawn through non-metallic PVC rigid concealed conduit, 20mm outer dia (ISI marked) heavy mechanical stress (HMS) grade in accordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thick. The external dia shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I (ISI marked) including conduit accessories like bends, tees, junction boxes etc fixed concealed with all accessories complete all as specified and as directed by Engineer-in-charge. Note 01: 2 runs of 4.00 Sqmm copper cable & 1 run of 4.00 Sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit. Note 02: The rate of cutting chases required for concealed conduit/flush boxes etc. is deemed to be included in overall rate quoted and nothing extra shall be paid for this.
Taking down existing exhaust fan/ceiling fan any size with due care and refixing with new lock bolt (where required) after servicing and painting including connecting electrically using PVC insulated overall sheathed flexible copper conductor cable 0.75 mm complete all as specified and as directed.
Supply and fixing exhaust fan 200mm sweep, heavy duty motor with double ball bearing, PVC body with PVC louvers, 900 RPM, with bird guard to protect the fan in running condition,AC, single phase, 230Volts, including connection with 1.5 sqmm mutistrand copper conductor flexible wire from ceiling rose, including outside louvers with proper hole and necessary fixing arrangment and making good to disturbed surface complete all as specified and as directed .
Supply and fixing electronic modular fan regulator step type not less than 100/120 watt with suitable plate and cover complete all as specified and as directed.
Material and labour for rigid non metalic PVC conduit 25 mm exclusives of boxes but including all Tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles and pipe hooks etc complete all as specified and as directed.
Material and labour for rigid non metalic PVC conduit 20 mm exclusives of boxes but incl all Tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles and pipe hooks etc.complete all as specified and as directed.
Material and labour for distribution board iron clad TPN DB, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar. Make-Legrand Cat pt No 5077 30 or equivalent of make L&T / Merlin Gerin multi-9 complete with one MCCB 4 pole 415 Volts 125 Amps rating with rupturing cap 25 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engineer-in-Charge. (Note: MCB's and MCCB will be measured and paid seperately under relevent items)
Supply and fixing sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases cutting in wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note - MCBs will be measured separately.
Supply and fixing MCB SP 6 to 32 Amps10KA, 'C' curve 240 Volts complete all as specified and as directed.
Supply and fixing MCB SPN 63 Amps 10KA, 'C' curve 240 Volts complete all as specified and as directed.
Supply and fixing MCCB TPN 125 Amps 35 KA ,415 Volts lcs = 100% lcu, with fixed magnetic and adjustable thermal release, adjustable overload 80-100% and adjustable short ckt 5 to 10 ln setting complete with phase seperator complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvanised iron or steel pipe light grade 40 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009 complete all as specified and as directed. Note: RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover shall be provided.
Taking down and refixing of water heater storage type Geyser complete of capacity 25 liters removing 4 Nos bolts and fasteners including PVC washers at both ends, and refixing the same complete all as specified & directed.
Supply and Install the electric water heater storage type 25 Ltr capacity 5 star rated of vertical type and having the wall mounting arrangement, thermostst, indicators and thermally insulated tank of glass lined inside the tank and heating element of 2KW, 240 Volts 50 HZ Ac operated including fixing nut, bolts, PVC connections of size 24" ( 2 Nos For Each geyser) with brass head with ABS plastic body with fastners grouted on wall complete all as specified and as directed.
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases cutting in wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note - MCBs will be measured separately.
SCHEDULE 'A' PARTI-III (PATH WORK)
Material and labour for hardcore of broken stone or boulders of gauge n.exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and well rammed to a true surface complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC 1:3:6 type C -2 using 40 mm graded crushed stone aggregate as in sub base of path and the like complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B-0 (using 12.50mm graded crushed stone aggregate) as in, coping, benching and similar work including necessary form work complete all as specified and directed by Engineer-in-Charge.
Material and labour for pre-polished coloured chequered cement concrete tiles 20cm x 20cm and 25 mm thick, factory made, machine pressed, with grey cement and pigment set and jointed and pointed in neat cement slurry as in floors, and cut and polished, laid over and inclduing 15mm thick screed bed of bedding layer in cement mortar inclduing finishing the surface even and rough complete all as specified and as directed.
SCHEDULE 'A' PARTI-IV (EXTERNAL ELECTRIC SUPPLY WORK)
Supply, laying, jointing and testing, fixing to wall using clamps/pole/floor or passing through pipes / ducts /road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened, PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 4 core 25.00 sqmm conforming to IS - 7098 Part-1 and its latest amendments complete all as specified and as directed by Engineer-in-Charge.
Supply, laying, jointing and testing, fixing to wall using clamps/pole/floor or passing through pipes / ducts /road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated, screened, PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 3.5 core 50.00 sqmm conforming to IS - 7098 Part-1 and its latest amendments complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches in exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, etc or for shaft, wells, cesspits, manholes, pier holes, etc, n.exc 10 sqm on plan and n exc 1.50 in depth and getting out in any type of soil complete all as specified and as directed. (For external electric supply and sewage disposal work)
Material and labour for sand cushioning to underground cable with dry sand locally available 8cm thick before laying of the cable and 15cm thick after laying and stretching the cable below the bricks/PCC cover, punning of sand using suitable T&P as per site condition, complete all as specified and as directed by Engineer-in-Charge. Note: Punned thickness of sand to be consider for measurement purpose.
Returning, filling, including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and as directed. (For external electric supply and sewage disposal work)
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. (For external electric supply and sewage disposal work)
Supply and laying un-reinforced pre cast concrete cable cover conforming to IS: 5820 with minimum average breaking load capacity 200 kgs for unreinforced covers , class LV Type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed by Engineer-in-Charge.
GI tubing Light grade 50 mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken Gi pipes, complete all as specified and as directed by Engineer-in-Charge.
SCHEDULE 'A' PARTI-V (SEWAGE DISPOSAL WORK)
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM Internal dia of pipe 150 mm complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipe including packing under and haunching against the sides of pipes after they are laid and tested in for 150mm bore of pipe complete all as specified and directed
Material and labour for 150mm dia reinforced concrete pipe Class NP3 laid in trenches and jointed completely with collars complete all as specified and as directed.
Cutting into existing manholes for connecting new drains 150mm dia, making good to pipe & rendering, cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, & reforming benching as required complete all as specified and as directed.
SCHEDULE 'A' PART-VII (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
Note: (1) The repair has to carried out as and when required basis and accordingly site will be available in piecemeal wise and as directed by Enginer-in-Charge in the Air Force station at Jammu
M/S MOHAN LAL GUPTA
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
DES RAJ NAGPAL CONTRACTORS PVT.LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .