Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹25.2 L
EMD Value
₹18,870
Closing Date
4 Nov 2026, 5:30 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
MR SE ENM RAIPUR RICHA(DFLT)
EinC E/M
Utility Shifting Electrical work of Newly Construction of H.L. Bridge i/c approach road across Makhamala Nalla amd Naini Nalla on Tumgaon-Sirpur-Baldakachhar Road at District- Mahasamund (C.G.)
201989
SYSTEM TENDER NO NIT NO: 133/S.E.E/M Raipur /2026-27 Dated:.15-10-2026
RESTRICTED TENDER
WORKS
PERCENTAGE
EinC E/M
Required Past Technical Experience: As per NIT
9 documents required · 9 mandatory
Public Works Department (PWD)
WORKS
MR SE ENM RAIPUR RICHA(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B C D
EinC E/M
E/M Circle, Raipur
E/M DIVISION NAVA RAIPUR
No
48
201989
4 Nov, 2026 5:30:00 PM IST
10 Nov, 2026 11:30:00 AM IST
15 Oct, 2026 8:00:00 PM IST
120
SYSTEM TENDER NO NIT NO: 133/S.E.E/M Raipur /2026-27 Dated:.15-10-2026
Utility Shifting Electrical work of Newly Construction of H.L. Bridge i/c approach road across Makhamala Nalla amd Naini Nalla on Tumgaon-Sirpur-Baldakachhar Road at District- Mahasamund (C.G.)
18870.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
2516000.00
2
9 Nov, 2026 5:30:00 PM IST
2516000
0.00
0.00
As per NIT
08
0.00 INR
19d 21h 26m
9 documents required · 9 mandatory
₹0
₹18,870
15 Oct 2026
15 Oct 2026
10 Nov 2026
15 Oct 2026
9 Nov 2026
Providing and fixing porcelain re-wireble fuse carrier and base unit on wooden board including drilling holes on the board, screws, connections etc. as per specification. 7.11.4 100 Amps
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Supplying and laying following size medium class G.I. pipe in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification.14.3.1 50 mm Internal Dia
Supply of "H" beam steel pole as per IS specifications in standard length for over head line work: 19.1.2 "H" beam steel pole 152x152x7x12 mm standard weight 37.1 kg /metre
Supply of steel R.S. JOIST as per IS specifications in standard length for over head line work: 19.2.2 Designation ISMB 175 size 175x90x8.6x5.5mm weight 19.3 kg /metre
Erection of STEEL TUBULAR or "H" BEAM/ ISMB pole in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation and cement concrete collar of size 0.4 metre dia and 0.50 metre height from ground level including excavation and refilling etc. as per specification of length: 19.11.5 11 metre to 12 metre
13 metre to 14 metre
Supply and fixing following overhead line accessories. 20.1.12 DC cross arm made of MS channel 100x50x5 mm @ 9.56 kg/m
Supplying and erection of shackle insulator with G.I. bolts, nuts and straps etc. as per specification. 20.11.2 Size 100mm x 110mm
Supplying and fixing guard insulator or split insulator complete 20.15.3 50x50 mm
Supplying and erection of stay set complete (galvanized) with 19/20mm dia x 1.8 metre long stay rod, anchor plate of size 300mm x 300mm x 6.4 mm, thimble stay clamps, bow tightener, strain insulator and specified G.I. stay wire etc. in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as per specification. 20.3.2 With 7/3.15 mm dia G.I. stay wire
Supplying and erection of angle/channel iron cross arms/ bracket/ other fitting of approved size and shape including drilling of holes for insulator pins, bolts and nuts etc as per specification.
Supplying and erection of MV horn gap lightening arrester.
Supplying and erection of 11 KV D.O. fuse unit on existing two pole structure with insulators and all other accessories complete including locking arangement as per specification.
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as per specification.
Supply and erection standard ACSR (aluminium conductor steel reinforced) confirming to IS 398-1961 of approved make at existing insulator at height upto 14m from ground level including stringing, binding with insulator, jointing wherever required, jumpering, tearing off connection etc complete etc. as per specification including clearing off obstacle if any: 20.32.2 Weasel 6/1/2.59mm dia with calculated aluminium area 31.61 sq.mm , weight 128 kg/ km (80 amps)
Rabbit 6/1/3.35mm dia with calculated aluminium area 52.88 sq.mm, weight 214 kg/ km (100 amps)
Supplying and erection DANGER BOARD made MS sheet duly painted and maked as per IE rules and specification.
Supply and errection of following Polymer Insulator with G.I. Bolt, Nuts and Straps etc. as per specification. 20.34.3 11 KV Disc Insulator
11 KV Pin Insulator with Pin
Dismantling of steel pole, R. S. joist, girder pole from the cement concrete foundation with bracket, insulators, stay wires etc, refilling the pit upto ground level including shifting of dismantled material to department store.
Dismantling of stay set from the cement concrete foundation, refilling the pit upto ground level including shifting of dismantled material to department store.
Earth work in hard rock (without blasting) with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling with excavated soil in trench / pit to ground level complete as per specification
Providing and laying Cast-in-situ cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm including mixing with mechanical mixer, compacting with vibrator, finishing and currying etc. complete but excluding form work.
Supplying and fixing of M S Nuts and bolts of various sizes 16x200mm/16x250mm/16x300/20x75mm/20x90mm/20x110mm/24x120mm/16x100mm/16x160mm as per REC specifications
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
963995907329481432_201989_Affidavit_affidavit.docx
NIT • 0.01 MB
2033578884000502677_201989_NIT_NIT Schedule Msmd.xlsx
NIT • 0.02 MB
4745562239919583025_201989_Term Condition and other Docu_Appendix 2.10 Online (3).doc
NIT • 0.27 MB
4745562239919583025_201989_Term Condition and other Docu_Approved material Mahasamund Tender.xlsx
NIT • 0.01 MB
4745562239919583025_201989_Term Condition and other Docu_flysheet.doc
NIT • 0.05 MB
4745562239919583025_201989_Term Condition and other Docu_Form_A 2.13 Online (2).doc
NIT • 0.15 MB
4745562239919583025_201989_Term Condition and other Docu_Long mow.docx
NIT • 0.04 MB
4745562239919583025_201989_Term Condition and other Docu_Short Notice mow.docx
NIT • 0.02 MB
4745562239919583025_201989_Term Condition and other Docu_Tecnical memo 24-25.docx
NIT • 0.03 MB
4745562239919583025_201989_Term Condition and other Docu_Terms & Condition.docx
NIT • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .