| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.2 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | l2₹91.4 L+₹2.2 L (2.50%)Rejected-Finance ASSAM CHANDMARI GUWAHATI 03 | l2 | Rejected-Finance Quote high | |
| 3 | l3₹93.6 L+₹4.5 L (5.00%)Rejected-Finance | l3 | Rejected-Finance Quoted high |
Tender Value
₹89.2 L
EMD Value
₹1.8 L
Closing Date
24 Jan 2020, 3:00 pmClosed
SE PWD(R and B) Circle, Kokrajhar
O/o the SE PWD(R and B) Circle, Kokrajhar
Up-gradation/Renovation of various projects at Barama College under Rastriya Uchchatar Siksha Abhiyan (RUSA) under RUSA 2.0 (New construction of Class Room)
2020_BoTC_15783_1
TN 145 of 2019-20 - 145/2
Open Tender
Furniture/ Fixture
Works
360 days
BAKSA
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,700
Principal Secretary, BTC
₹1.8 L
Yes
24 Feb 2020
8 Jan 2020
24 Jan 2020
8 Jan 2020
24 Jan 2020
8 Jan 2020
8 Jan 2020 - 24 Jan 2020
Amount
(A) Civil Works (Ground Floor): Earth Work Earth work in excavation for foundation trenches of walls, retaining walls, footing of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completing of work. breaking clods in return filling dressing, watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in the following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (Predominantly non plastic) by truck carriage including loading andf unloading.
STEEL WORK: Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steeel/Jindal steel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars.
CEMENT CONCRETE WORK : Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
SHUTTERING & FORMWORK: Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.1. Foundation, footings, base of columns, pile cap, raft and mass concrete works etc. (ii) Using 25mm thick plank
SHUTTERING & FORMWORK: Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.2 Sides of tie beams, plinth beams, grade beams etc. at or below ground level. (i) using 25mm thick plank.
SHUTTERING & FORMWORK: Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.3 3. Colums, pillars, posts & strut (a) Square, rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face. (ii) Using 25mm thick plank
SHUTTERING & FORMWORK: Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.4. Sides and soffits of beams, beam haunching, cantilever, girders, bressumers lintelsand horizontal ties. (a) For depth not exceeding 1.0M (ii) Using 25mm thick plank
SHUTTERING & FORMWORK: Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.5 Flat surfaces such as soffits of suspended floors, roofs, landing, cantilever slabs, chajjas, balconies, and the like. (a) Floors etc. upto 200mm in thickness. (ii) Using 25mm thick plank
SHUTTERING & FORMWORK: Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.10 Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
PRE CONSTRUCTION ANTI-TERMITE TREATMENT: Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) liters per square meter towards the concrete and masonary walls so as to ensure earth in contact with the structure well treated-with. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
BRICK WORK Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed . (I) In sub-structure up to plinth level including dewatering if necessary (b) In proportion 1:4
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112 mm thick brick wall (a) In cement mortar in proportion 1:4.
WOOD WORK Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (b) With 1st class timber (Bonsum/ Sundi)
Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately ) B) With 1st class local wood (Gamari/Hollock/Bonsum ) (ii) 35 mm thick.
Providing, fitting and fixing PVC door frame of Duroplast make DPF-5060 make suitable for DPS-3720 made from extruded PVC multichamber hollow section having dimensions of 50mmx60mm (Toletance + 1mm). Horizontal and vertical sections shall be joined by steel screws after inserting M.S. tubular rectangular galvanised L-shaped brackets of size 100mmx100mm or plastic brackets of size 75mmx75mm with metred cut at the corners. Hinge side of the frame shall be reinforced with M.S.Tubular section of size 40mmx20mm. The frame will be fixed to the column/ stiffner/ wall with the help of 3 nos 75mm long and 4mm dia steel screws and expandable fastners on each side of the door .
Providing, fitting and fixing PVC Door shutters of Duroplast DPS 3720 make made fromm extruded PVC stiles and rails made from rigid PVC multicavity hollow chamber section of size 90mmx37mm (Toletance+ 1mm). The corners of the stiles and rails shall be metred out and fixed to each other with the help of solid plastic L-shaped brackets or M.S. rectangular tubular galvanised two nos of size 200mmx100mm and 100mmx100mm at each corner by self tapping steel screws................
ALUMINIUM WINDOW & VENTILATOR : Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required (b) Fixed windows and ventilators (iv) 5 mm clear glass
GRILL WORKS: Providing fitting and fixing M.S grill of required pattern for windows/ clerestory windows/openingwith M.S flats at required spacing in frame all ground, squre or round M.S bars with round headed bolts and nuts or screws. II. Omamental Grill (c) Fixed to Brickwork/P.C.C/R.C.C
FLOORING WORKS 65mm thick cement concrete floor consisting of 50mm under layer of cement concrete 1:3:6 of size (1 cement 3 coarse sand 6 coarse agg. Of size 25mm down) and 15mm thick wearing layer in cement concrete in prop 1:1:2 (1 cement : 1 coarse sand : 2 coarse agg of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for boad @ 2.75Kg per sqm of floor area) including curring etc.complete as directed.
PLASTERING WORKS: 10mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering upto 1st floor level including arrises or rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. (B) On fair side (b) In cement mortar 1:4
20 mm thick Cement plaster in two coats, on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15mm and finioshing coat 5mm thick) (b) In cement mortar 1:4
PLINTH PROTECTION WORKS: Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
PAINTING Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting (b). With ready mixed paint, wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or grith b) High Gloss (Asian paint/Berger paint/ICI/J&N paint/Nerolac)
Applying priming coat over new steel and other surface over 100mm in grith/width after preparing thr surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed red lead/red oxide primer
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint or approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or grith b) High Gloss (Asian paint/Berger paint/ICI/J&N paint/Nerolac)
Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed.
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (ii) Thickness = 1.0mm thick
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
DOOR WINDOW FITTINGS : Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )
(B) Civil Works (First Floor): STEEL WORK: Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steeel/Jindal steel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars.
Extra over item 18.1.1 (a.b,c) for each subsequent floor or part thereof above first floor level.
CEMENT CONCRETE WORK: Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
Extra over item 2.2.1 (I) (B) above for each subsequent floor or part thereof above first floor level.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.3 Columns, Pillars, Posts & Strut (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face. (i) Using 25mm thick plank
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.1.1 & 3.1.3(b)
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.4 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M. (ii) using 25mm thick plank
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.1.1 & 3.1.3(b)
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.5 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness. (ii) using 25mm thick plank
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.1.1 & 3.1.3(b)
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.10 Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.1.1 & 3.1.3(b)
BRICK WORK : 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement : 4 sand)
Extra for brick walling for each subsequent floor or part thereof above the First Floor level. (a) 112mm thick brick/R.B. Wall
WOOD WORK : Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (b) With 1st class timber (Bonsum/ Sundi)
Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately ) B) With 1st class local wood (Gamari/Hollock/Bonsum) (ii) 35 mm thick.
Providing, fitting and fixing PVC door frame of Duroplast make DPF-5060 make suitable for DPS-3720 made from extruded PVC multichamber hollow section having dimensions of 50mmx60mm (Toletance + 1mm). Horizontal and vertical sections shall be joined by steel screws after inserting M.S. tubular rectangular galvanised L-shaped brackets of size 100mmx100mm or plastic brackets of size 75mmx75mm with metred cut at the corners. Hinge side of the frame shall be reinforced with M.S.Tubular section of size 40mmx20mm. The frame will be fixed to the column/ stiffner/ wall with the help of 3 nos 75mm long and 4mm dia......
Providing, fitting and fixing PVC Door shutters of Duroplast DPS 3720 make made fromm extruded PVC stiles and rails made from rigid PVC multicavity hollow chamber section of size 90mmx37mm (Toletance+ 1mm). The corners of the stiles and rails shall be metred out and fixed to each other with the help of solid plastic L-shaped brackets or M.S. rectangular tubular galvanised two nos of size 200mmx100mm and 100mmx100mm at each corner by self tapping steel screws. .....
ALUMINIUM WINDOW & VENTILATOR : Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required.......... (b) Fixed windows and ventilators (iv) 5 mm clear glass
FLOORING WORKS 40mm thick cement concrete floor consisting of 25mm under layer of cement concrete 1:3:6 of size (1 cement 3 coarse sand 6 coarse agg. Of size 12.5mm down) and 15mm thick wearing layer in cement concrete in prop 1:1:2 (1 cement : 1 coarse sand: 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @2.75Kg per. square metre of.
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4
Extra over item no.6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
Extra over item no.6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) b) In cement mortar 1:4
Extra over item no.6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
GRILL WORKS Providing fitting and fixing M.S grill of required pattern for windows/ clerestory windows/openingwith M.S flats at required spacing in frame all ground, squre or round M.S bars with round headed bolts and nuts or screws. II. Omamental Grill (c) Fixed to Brickwork/P.C.C/R.C.C
PAINTING Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting (b). With ready mixed paint, wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or grith b) High Gloss (Asian paint/Berger paint/ICI/J&N paint/Nerolac)
Applying priming coat over new steel and other surface over 100mm in grith/width after preparing thr surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed red lead/red oxide primer
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or girth. (b) High gloss (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac)
Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed.
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (ii) Thickness = 1.0mm thick
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Extra over item no.13.4.1 above for painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac) on ceilling and on sloping roof.
DOOR WINDOW FITTINGS Supplying fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete (anodised to bright natural matt & satin finished)
(C) Civil Works (Head Room): STEEL WORK: Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work /R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steeel/Jindal steel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars.
Extra over item 18.1.1 (a,b,c) for each subsequent floor or part thereof above first floor level.
CEMENT CONCRETE WORK Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (B) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) Without using admixture plasticiser b) M-20 grade concrete or prop.1:1.5:3
Extra over item 2.2.1 (i) (B) above for each subsequent floor or part thereof above 1st floor level.
SHUTTERING & FORMWORK Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc hight of proping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.3 Columns, Pillars, posts & Strut (a) Square, Rectangular, Polygonal in plan or any shape like Tee/L etc. having plane vertical face. (ii) Using 25mm thick plank.
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.1.1 & 3.1.3 (b)
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc hight of proping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.4 Sides and soffits of beams, beam haunchings, cantilever, girders, bressumers lintelsand horizontal ties. (a) For depth not eceeeding 1.0M. (ii) Using 25mm thick plank.
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.1.1 & 3.1.3 (b)
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc hight of proping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.5 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness. (i) using 38mm thick plank
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.1.1 & 3.1.3 (b)
BRICK WORK 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112 mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement: 4 sand)
Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. (a) 112mm thick brick/R.B Wall
WOOD WORK Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mm x 3mm x 250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (b) With 1st class timber (Bonsum/ Sundi)
Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately) B) With 1st class local wood (Gamari/Hollock/Bonsum ) (ii) 35 mm thick.
ALUMINIUM WINDOW & VENTILATOR : Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required (b) Fixed windows and ventilators (iv) 5 mm clear glass
PLASTERING WORKS: 10mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering upto 1st floor level including arrises or rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
PAINTING Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting (b). With ready mixed paint, wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or grith b) High Gloss (Asian paint/Berger paint/ICI/J&N paint/Nerolac)
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Extra over item no.13.4.1 above for painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac) on ceilling and on sloping roof.
DOOR WINDOW FITTINGS : Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )
(D) Internal Electrification: Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.1 Short point up to 3.00 metre. length.
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.2 Medium point up to 6.00 metre. length.
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1.1.3 Long point up to 10.00 metre. length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. 1.2.1 Short point up to 3.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. 1.2.2 Medium point up to 6.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. 1.2.3 Long point up to 10.00 metre. Length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.1 With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in flat 19 mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.2 With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in flat 19 mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.3 With 2 x 6 sq. mm. + earth continuity with 1x4 sq. mm. cable in flat 25 mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.4 With 2 x 10 sq. mm. + earth continuity with 1x6 sq. mm. cable in flat 25 mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.5 With 2 x 16 sq. mm. + earth continuity with 1x10 sq. mm. cable in flat 25 mm ISI marked casing 'n' capping system.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. 1.8.2 With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in flat 19 mm ISI marked casing 'n' capping system.
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system complete. 1.12.1 Short point up to 3.00 metre. Length.
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system complete. 1.12.2 Medium point up to 6.00 metre. Length.
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco/Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system complete. 1.12.3 Long point up to 10.00 metre. Length.
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.1 Short point up to 3.00 metre. Length.
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.2 Medium point up to 6.00 metre. Length.
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.3 Long point up to 10.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.).................... 2.2.1 Short point up to 3.00 metre. length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.).................... 2.2.2 Medium point up to 6.00 metre. length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.).................... 2.2.3 Long point up to 10.00 metre. length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/Mw or equivalent make as approved by the Deptt.) wiring system. 2.9.1 With 4 x 2.5 sq. mm. + earth continuity with 2x1.5 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/Mw or equivalent make as approved by the Deptt.) wiring system. 2.9.4 With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2mm thick/heavy rigid PVC IS: 9537 Part-III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. 5.11.1 With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for twin control light point with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system with 2 way 5/6 amp F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) 1.6.1 Short point up to 3.00 metre. Length.
Wiring for twin control light point with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system with 2 way 5/6 amp F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) 1.6.2 Medium point up to 6.00 metre. Length.
Wiring for twin control light point with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system with 2 way 5/6 amp F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) 1.6.3 Long point up to 10.00 metre. Length.
Supplying and fixing 32mm dia ISI marked steel conduit pipe (AKG or equivalent as approved by the deptt.) on surface including painting etc. as required.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco/Anchor or Equivalent Make as approved by the Deptt.) in existing surface conduit wiring system including connection as required. 9.1.9 With 3 x 4 sq. mm. earth continuity with 2x4 sq.mm.copper conduit conductor cable.
Supplying and fixing 18 S.W.G sheet steel metal boxes of the following sizes in surface/recessed wiring system with suitable size of 3 mm thickness phenolic laminated sheet cover on the front face of the boxes including painting etc. as required and specified by the department. 10.2.8 250 mm x 300 mm x 60 mm deep (Nominal Size)
Supplying and fiixing of switch/socket flush type (Anchor Penta PC CHERRY/Gold medal/Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on the existing PVC /MS board including connection as approved by the deptt.) complete as required.
Supplying and fixing of 3 plate Ceiling Rose (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on the existing block including connection as approved by the Deptt.) complete as required
Supplying and fixing of plain Pendent holder (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) with twin twisted flexible cord including connection as approved by the Deptt.) complete. Without Lamp.
Supplying and fixing of 3 Pin Top 6/16 Amp on the existing 6/16 Amp Socket including connection as approved by the Deptt.) complete as required.
Fitting and fixing of brackets on the wall in GI/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover with all accessories such as GI/MS switch board (ISI marked) with phenolic laminated sheet cover including connection as approved by the Deptt.) as required complete.
Supplying and fixing of call bell (Buzzer) including 5/6 amp capacity button piano type bell push switch including connection as approved by the Deptt.) as required.
Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt.
Installation, testing and commissioning of ceiling fan including the regular/down rod of standard size (Up to 300mm) length including connection as approved by the Deptt.) as required.
Cutting including theading and fitting of G.I. Pipe heavy gauge down rod for ceiling fans etc. as required (Labour charge)
Installation of Exhaust fan up to 450 mm sweep in the existing opening including making the hole to suit the size of the above fan, making good the damages, tseting, commissioning etc. as required complete.
Supplying fixing I.C.T.P and N link main switch with rewire able fuse of 500 Volt grader (HPL/GECO, ANCHOR or equivalent make) including drilling board/Iron frames and fixing with bolts and nuts and connection as approved by the department. complete as required. 12.2.3 60/63 Amps Capacity T.P.N.
Supplying fixing I.C.T.P and N distribution fuse boards with rewire able fuses 415 Volt grade (HPL/GECO, ANCHOR or equivalent make) 16/32/63 Amps per way including drilling boards/iron frames and fixing with bolts and nuts and connection as approved by the Deptt.) complete as required. 12.5.1 4-way T.P.D.B 16 Amps/way.
Supplying with fitting and fixing MCCB income and MCB outgoing sheet, steel, phosphatised, powder painted double door IP-43 double door surface mounting vertical TPN MCB DB incorporated with bas-bar, up to 250A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.30.1 Richa, Bentec, Adhunic, V-Gauard make) 15.30.1.2 8 way TPN (4+18) double door
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved specified and directed by the deptt. 16.6.2 C-Series (ABB, Scheneider MG, legrand, Hanger make) 16.6.2.3 63A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.7.2 100/300mA sensitivity DP RCCB 16.7.2.3 63A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.9.1 30mA sensitivity DP RCBO 16.9.1.5 40A
Supply with installation & commissioning of ready made maintenance free CPRI approved chemical earthing system with 50mm dia.3.00 Meters length corrosion free dual pipe technology G.I CHEMRODE ELECTRODE complete with RESLOW Grounding Minerals (25 K and Advance Earth Pit cover (PV including excavation of earth pit and construction brick earth chamber including plastering both inner & outer surface of brick wall as specified and directed by the deptt.
Supplying & laying of 8 SWG G.I. Earth drawn through 15mm dia Medium quality G.I. pipe from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying including installation, connection as approved by the deptt. testing and commissioning of SUBMERSIBLE PUMP SET, Single phase with steel cable rope and submersible cable complete as directed and specified by the deptt. 39.6.7 Single phase submersible motor pump set (Texmo/Crompton Greaves/Aquatic/CRI/V-Guar suitable for 100 mm bore well aand above 2 HP STAGE 6 to 30 with control panel.
Supplying fitting and fixing including necessary connection as approved by the deptt.) of Starter (Crompton Greaves/Control & Switch Gear/BCH/L&T/Siemens make) of following type and capacity as specified and directed by the Department (Crompton Greaves/Control & Switch Gear/ BCH / L &T/Siemes make) 39.8.1 D.O.L Starter (Crompton Greaves/Control Greaves/Control & Switch Gear/BCH/L&T/Siemens make) 0.5 to 10 HP, 0.72 to 20 A
Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make) ECBC 1.1.1 Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the deptt.) as required complete and as directed by the department. 27.2.1 Domestic 27.2.1.1 Ventilator RX 150mm sweep (ORIENT make) Brisk Air 150mm sweep Louver type (Crompton make)
Supplying & laying of 8 SWG copper earth drawn through 15mm dia Medium quality G.I. pipe from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
(E) Sanitary Installation: Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high) with seat and lead, CP brass hinges and rubber buffers, CI/MSbrackets, 40mm dia flush band with fittings including painting of fittings and brackets, required (Flushing Cistern to be separately) (A) Parryware Make (b) Coloured (iv) Combination Closet P Trap (Cat. No.C0204) (Inclusive of seat cover)
Supplying fitting and fixing automatic flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. complete as directed and specified (pipes will be measured separately) i) Parruyware make EFS DC Retrofit (Cat. No.C8087) /EFS AC Retrofit (Cat. No.C8088)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. A) Parryware make a) White (i) Integrated EFS-Smart DC (Cat No.C8182)/Integrated EFS-Smart
Providing fitting and fixing vitreous china squatting plate urinal with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (A) Parryware Make (ii) Coloured (Cat. No.C0573)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) Pedestal Basin (With pedestal) (B) Hindware Make (a) White (vi) Lara 840 x 500 (cal. No.10089/11035)
Providing fitting and fixing Glass Shelf complete as directed and specified. Glass shelf with C.P. Guard rail (i) Agmeco make (a) Cubin (Cat. No.CB-00104)
Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified. (A) Parryware Make (i) Recess SP & SG dish (Cat.No. C9935)
Providing, fitting and fixing CP soap tray/ soap dish complete as directed and specified. (I) Jaquare Make (b) Queen's (cat No.AQN-7731)
Providing, fitting and fixing Liquid soap dispenser and liquid soap container complete as directed and specified. (I) Jaquare Make (b) Continental (Cat. No.ACN-1137N) (with mettalic bottle)
Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (i) Continental 300mm for wash basin (Cat.No.ACN-1101N)
Providing, fitting and fixing Chrome Plated towel rack complete as directed and specified. (a) Jaquar make (i) Continental 600mm long with hanger (Cat.No.ACN-1181N)
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified. (a) Jaquar make (i) Continental towel ring square (Cat.No.ACN-1121)
Providing, fitting and fixing Chrome Plated robe hook complete as directed and specified. (a) Jaquar make (i) Continental (Cat.No.ACN-1191N)
Providing, fitting and fixing Chrome Plated brush holder complete as directed and specified. (a) Jaquar make (i) Continental (Cat.No.ACN-1143N)
TOILET PAPAER HOLDER Providing, fitting and fixing Chrome Plated brush holder complete as directed and specified. (a) Jaquar make (i) Continental toilet paper holder with flap (Cat.No.ACN-1153N)
WASTE COUPLING Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (a) Jaquar make (i) 32mm (HT/FT) (Cat.No.ALD-705/709)
WASTE COUPLING Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. (a) Jaquar make (i) Bottle trap (with internal partition) 32mm size with 250mm long wall connection pipe (Cat.No.ALD-769)
WASTE COUPLING Providing, fitting and fixing Chrome Plated bottle trap pipe complete as directed and specified. (a) Sona make (i) Pipe for bottle trap 300mm long (Cat. No.BT-0761)
Supplying, fitting and fixing PVC pipes of 6Kg/cm2 (Superme/Prince) or other ISI approved including jointing, fitting and fixing wall clams etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying, fitting and fixing PVC pipes of 6Kg/cm2 (Superme/Prince) or other ISI approved including jointing, fitting and fixing wall clams etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surfaces or in trenches. (iii) 90mm dia.
Supplying, fitting and fixing PVC pipes of 6Kg/cm2 (Superme/Prince) or other ISI approved including jointing, fitting and fixing wall clams etc. as necessary complete at all levels including below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. (ii) 110mm dia.
Supplying, fitting and fixing PVC pipes of 6Kg/cm2 (Superme/Prince) or other ISI approved including jointing, fitting and fixing wall clams etc. as necessary complete at all levels including below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. (iii) 90mm dia.
Supplying fitting and fixing 87.5 degree PVC bend with door (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia.
Supplying fitting and fixing 87.5 degree PVC bend with door (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. iii) 90mm dia.
Supplying fitting and fixing 87.5 degree PVC bend with door (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. ii) 110mm dia.
Supplying fitting and fixing 87.5 degree PVC bend with door (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. iii) 90mm dia.
Supplying fitting and fixing 87.5 degree PVC bend with door (supremo/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia.
Supplying fitting and fixing 87.5 degree PVC bend with door (supremo/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. iii) 90mm dia.
Supplying fitting and fixing 87.5 degree PVC bend with door (supremo/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. ii) 110mm dia.
Supplying fitting and fixing 87.5 degree PVC bend with door (supremo/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. iii) 90mm dia.
Supplying fitting and fixing 45 degree PVC bend of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia.
Supplying fitting and fixing 45 degree PVC bend of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. iii) 90mm dia.
Supplying fitting and fixing 45 degree PVC bend of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. ii) 110mm dia.
Supplying fitting and fixing 45 degree PVC bend of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. iii) 90mm dia.
Supplying fitting and fixing PVC plain single tee of (Supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia.
Supplying fitting and fixing PVC plain single tee of (Supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. iii) 90mm dia.
Supplying fitting and fixing PVC plain single tee of (Supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. ii) 110mm dia.
Supplying fitting and fixing PVC plain single tee of (Supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. iii) 90mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (iii) 90mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. (ii) 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. (iii) 90mm dia.
Supplying fitting and fixing PVC single Y of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 110mm dia.
Supplying fitting and fixing PVC single Y of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. iii) 90mm dia.
Supplying fitting and fixing PVC single Y of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. ii) 110mm dia.
Supplying fitting and fixing PVC single Y of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. iii) 90mm dia.
Supplying fitting and fixing PVC single Y with door of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. i) 110mm dia.
Supplying fitting and fixing PVC single Y with door of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 75mm dia.
Supplying fitting and fixing PVC single Y with door of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. i) 110mm dia.
Supplying fitting and fixing PVC single Y with door of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. ii) 75mm dia.
Supplying fitting and fixing PVC double 'Y' plain of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. i) 110mm dia.
Supplying fitting and fixing PVC double 'Y' plain of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 75mm dia.
Supplying fitting and fixing PVC double 'Y' plain of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. i) 110mm dia.
Supplying fitting and fixing PVC double 'Y' plain of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. ii) 75mm dia.
Supplying fitting and fixing PVC double 'Y' with door of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. i) 110mm dia.
Supplying fitting and fixing PVC double 'Y' with door of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 75mm dia.
Supplying fitting and fixing PVC double 'Y' with door of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. i) 110mm dia.
Supplying fitting and fixing PVC double 'Y' with door of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. ii) 75mm dia.
Supplying fitting and fixing PVC cross 'T' plain of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. i) 110mm x 110mm
Supplying fitting and fixing PVC cross 'T' plain of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 75mm x 75mm
Supplying fitting and fixing PVC cross 'T' plain of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. i) 110mm x 110mm
Supplying fitting and fixing PVC cross 'T' plain of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. ii) 75mm x 75mm
Supplying fitting and fixing PVC cross 'T' with door of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. i) 110mm x 110mm
Supplying fitting and fixing PVC cross 'T' with door of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. ii) 75mm x 75mm
Supplying fitting and fixing PVC cross 'T' with door of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. i) 110mm x 110mm
Supplying fitting and fixing PVC cross 'T' with door of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. ii) 75mm x 75mm
Supplying fitting and fixing PVC coupler of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. i) 110mm dia.
Supplying fitting and fixing PVC coupler of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. iii) 75mm dia.
Supplying fitting and fixing PVC coupler of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. i) 110mm dia.
Supplying fitting and fixing PVC coupler of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. iii) 75mm dia.
Supplying fitting and fixing PVC reducer of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. iv) 110mm x 75mm
Supplying fitting and fixing PVC reducer of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. iv) 110mm x 75mm
Supplying fitting and fixing PVC reducing Tee of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (a) In exposed surfaces or in trenches. iii) 110mm x 75mm
Supplying fitting and fixing PVC reducing Tee of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/CC/RCC and making good to the damages. iii) 110mm x 75mm
Supplying fitting and fixing PVC socket plug of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. in exposed surface of trenches as necessary complete at all levels including below G.L as directed and specified. a) 110mm
Supplying fitting and fixing PVC socket plug of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. in exposed surface of trenches as necessary complete at all levels including below G.L as directed and specified. b) 75mm
Supplying fitting and fixing PVC cleaning pipe of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. in exposed surface of trenches as necessary complete at all levels including below G.L as directed and specified. b) 110mm
Supplying fitting and fixing PVC cleaning pipe of (supreme/prince) or other ISI approved including joining, fitting and fixing etc. in exposed surface of trenches as necessary complete at all levels including below G.L as directed and specified. c) 75mm
COWEL Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. iv) 75mm dia PVC cowel of ISI make
Providing fitting and fixing C.I. Grating to the floors complete as directed and specified. a) 110mm dia.
Providing fitting and fixing C.I. Grating to the floors complete as directed and specified. b) 75mm dia.
Providing fitting and fixing (300x230) mm C.I. Yard gully hinged Grating complete as directed and specified.
C.P Grating (ii) 110mm dia
C.P Grating (iii) 75mm dia
SOAK PIT AND INSPECTION CHAMBER Construction of filter bed in soak pit including earth work in exacavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C.plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
SOAK PIT AND INSPECTION CHAMBER Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
(F) Water Supply: Supplying fitting and fixing approved uPVC pipes of different size with all necessary 'R' brand or Similar approved P.V.C Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. SUPREME/PRINCE/SFMC BRAND or other equvalent approved brand (High pressure pipe Sch-40) A) Exposed or in trenches. c) 32 mm dia.
Supplying fitting and fixing approved uPVC pipes of different size with all necessary 'R' brand or Similar approved P.V.C Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. SUPREME/PRINCE/SFMC BRAND or other equvalent approved brand (High pressure pipe Sch-40) A) Exposed or in trenches. e) 20 mm dia.
Supplying fitting and fixing approved uPVC pipes of different size with all necessary 'R' brand or Similar approved P.V.C Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. SUPREME/PRINCE/SFMC BRAND or other equvalent approved brand (High pressure pipe Sch-40) (B) Concealed by chiselling or breaking brick wall/C.C wall/RCC wall and making good to the damaged. SUPREME/PRINCE/SFMC/ FUSION/BAND or other equvalent approved brand (High pressure pipe Sch-40) c) 32 mm dia.
Supplying fitting and fixing approved uPVC pipes of different size with all necessary 'R' brand or Similar approved P.V.C Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. SUPREME/PRINCE/SFMC BRAND or other equvalent approved brand (High pressure pipe Sch-40) (B) Concealed by chiselling or breaking brick wall/C.C wall/RCC wall and making good to the damaged. SUPREME/PRINCE/SFMC/ FUSION/BAND or other equvalent approved brand (High pressure pipe Sch-40) e) 20 mm dia.
Supplying fitting and fixing C.P. Bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) VII) G) GHORE Brand Supply, Installation, Testing & Commissioning of Bib Tap Bau Flow-Grohe make: Cat No.-20235000 i) Bib cock
Supplying fitting and fixing polymer stop-cock of Prayag polymer make of approved size as mentioned below as directed and specified. (G.I. & C.P pipes will be measured separately) VI) Marc brand (a) Oriental Series (c) 15mm dia (Concealed type Roman handle)
PILLAR COCK Supplying and fitting and fixing C.P. Pillar cock of 15mm dia of approved brand as speciied and directed. VIII) GHORE Brand (a) Pillar cock
FLUSH COCK Supplying fitting and fixing Chore Plated (C.P) flush cock of approved brand as directed and specified. (G.I. & C.P. Pipes will be measured and paid separately) III) Jaquar brand a) Continental/Clarion (ii) Flush cock with wall flange 25mm with plain knob
VALVE Supplying and fitting gun metal country pit valve (full way valve) ISI Make as specified and directed. (b) 40mm dia.
VALVE Supplying and fitting gun metal country pit valve (full way valve) ISI Make as specified and directed. (d) 20mm dia.
Supplying fitting and fixing gun metal check valve including necessary threads to pipes. B) 40mm dia (Heavy type)
Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches including trenches and refilling the same etc complete as directed. B) uPVC pipe with uPVC fittings (Using uPVC high pressure pipe) (Using SUPREME/PRINCE/SFMC/FUSION brand pipe) ii) 20mm diameter
Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches including trenches and refilling the same etc complete as directed. B) uPVC pipe with uPVC fittings (Using uPVC high pressure pipe) (Using SUPREME/PRINCE/SFMC/FUSION brand pipe) iv) 32mm diameter
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes ii. 1500 Lt capacity a. Sintex make
Labour for erecting and placing PCVC Tank over the stagging up to a height of 5.00m complete as directed. (b) 1500 litre capacity
Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. ii. Bore hole of 100mm diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. (i) G.I. pipe (a) TATA/SAIL (Medium) socket should be welded to the pipes. iv. 100mm diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. (ii) PVC pipe SUPREME/PRINCE/FUSION/SFMC BRAND iv. 90mm diameter
Supplying fitting and fixing suction pipes plain/bevel ended conforming to relevent I.S code of practice including supplying and fitting of tube well accessories, lowering of assemble pipes concetrically in the casing pipes complete as directed by the department. B) PVC Pipes (Supreme/Prince/Fusion/Sfmc Brand) iii) 40mm diameter.
Supplying fitting and fixing GI filter 2.00 metre long.
Supplying fitting and fixing check valve (non return valve) including thread to pipes. Vii) 100mm diameter
Flushing cleaning eashing and watering of the tube well
(G) Fire Fighting: Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extingisher confirming to IS:15683:2006 with ISI mark and C02 cartridge will be confirming to IS:with ISI mark, Powder will be confirming to IS:4308 with ISI Mark (10kg) BRAND : FIRESTOP/FRIEND/FIRE SHIELD/GETECH/MINI MAX
Ganesh Daimary
SHRI ARUP BARO
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .