Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance HARI OM BHAWAN CIRCULAR ROAD UPPER KAITHU SHIMLA | Admitted-Finance |
| 2 | Admitted-Finance SCO 10 BLOCK NO 2 SDA COMPLEX KASUMPTI SHIMLA 09 | SHIMLA | HIMACHAL PRADESH | 171009 | Admitted-Finance |
Tender Value
₹44.7 L
EMD Value
₹89,500
Closing Date
3 Mar 2023, 5:00 pmClosed
XEN Elect Divn No II
XEN Elect Division No II HPPWD Shimla-1
Providing special repair to Central heating
2023_PWD_69442_1
ED.II.GA.Tender-22-23-9638-39 dated 21.02.2023
Open Tender
Electrical Works
Item Rate
180 days
IGMC Shimla
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,500
EE Elect Divn No II
₹89,500
10 Mar 2023
25 Feb 2023
4 Mar 2023
25 Feb 2023
3 Mar 2023
25 Feb 2023
Amount
Supplying, installation, testing & commissioning of compact type, Hi static Hiwall mounted power coated hot water fancy Forced air radiator unit of following capacity free air discharge capacity complete with fan blower suitable for operation on single phase 230 V 50 Hz AC supply complete with finned hot water finned coil. air filter washable complete with modulating valve / 3/4 " brass ball valve with strainer on inlet and 3/4" brass ball valve on outlet complete as required ( Ventair/ Rapidcool /GapsLTI)
Supply, installation, testing and commissioning of hot water piping and fittings complete with supports, hangers and specified insulation thickness. All piping shall be black mild steel Class C, ISI marked with fitting. The unit rate of piping shall include this support arrangement and hangers i/c wooden isolator where required under insulation at support points.The piping shall be insulated with 80Kg/ M.Cub. section density fiberglass insulation finally covered with 26 gauge Al. Cladding for inside and 6mm plaster for outside complete as required
50 mm pipe with 65 mm insulation.
38 mm pipe with 65mm insulation.
32 mm pipe with 65 mm insulation.
25 mm pipe with 65 mm insulation.
19 mm pipe with 50 mm insulation.
Supply, installation, testing and commissioning of Gate valves/ Sluice/ BF valves , with flanges or screwed ends as required. Valves 65 mm and above shall of C.I. IBR86 Body Grade A , with flanged ends and gunmetal trim, yoke type -rising stem ,P N. 1.6 and i/c flanges and valves upto 50mm shall be gunmetal flenged ends non rising stem, integral seat, (MAKE: KRILOSKAR/SANT/LEADER)
Supply and fixing of following size PVC insulated copper conductor control cable including making connections complete as required
3 Core 2.5 sqmm
3 Core 1.5 sqmm
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Two way Single Door
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240/440 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB complete with connections etc. as required:-
Double pole. Cat-A. 6 /32amp
Dismentaling old FCU/ convector and store in plant room as required complete i/c making good the damage
Dismantlling old and refixing of fan coil unit complete with aceeories lie bend tee niple sockets etc on exixting heating hot water pipe as per required and as directed by Engineer-in-charge.
KHARBANDA ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .