| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-Finance | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹10.3 L+₹35,665 (3.58%)Rejected-Finance | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹11.1 L+₹1.1 L (11.4%)Rejected-Finance | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹11.2 L+₹1.2 L (11.9%)Rejected-Finance B 12 BASEMENT PLOT NO 19 RETAIL BUSINESS CENTRE ADITYA COMPLEX NANGAL RAYA SOUTH WEST NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Being Not L1 |
Tender Value
₹14.6 L
EMD Value
₹29,110
Closing Date
3 Dec 2020, 6:00 pmClosed
AGE I U BR DELHI CANTT-10
AGE (I) (U) B/R DELHI CANTT-10
ADDN/ALTN OF OLD AC PLANT ROOM AT DIPAC UNDER AGE (I) (U) B/R DELHI CANTT-10
2020_MES_392863_1
8913/E8
Open Tender
Civil Works
Item Rate
120 days
AGE (I) (U) BR Delhi Cantt-10
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE I U BR DELHI CANTT 10
₹29,110
Yes
7 Jan 2021
5 Nov 2020
5 Dec 2020
5 Nov 2020
3 Dec 2020
19 Nov 2020
Amount
Demolition of plain cement concrete (unreinforced) of any description and any position not otherwise provided complete all as specified.
Demolition of reinforced cement concrete in beam, staircase, landing chajjas and similar work of any description and in any position not otherwise specifically provided for and rubbish off the premises upto 4 storeys building complete all as specified.
Taking down Chowkets or frames with shutters without taking off shutters from frames exceeding 1.50 Sqm but n exc 4.00 Sqm complete all as specified.
All as per item 3 above but not exceeding 1.50 Sqm.
Taking down shutter of any description not exc. 1.00 sqm each
M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregates), as in foundation and levelling course complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1(20mm graded aggregate),40 mm thick as in sub base to the tile flooring
M&L Vitrified Ceramic dark shade /coulour shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with coloured cement matching with surfaces of tiles as in floor 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and directed complete all as specified and directed
S&F powder coated aluminium three track sliding windows with three sliding shutters (one gauzed shutter including 0.36mm dia and 1.18mm aperture stainless steel wire mesh and two glazed shutter including 4 mm thick plane glass panes) made of aluminium sections not less than 1.1kg per meter for bottom and top tracks, side track 0.98 kg per metre, bottom shutter frame 0.55 kg per metre, top shutter frame 0.47 kg per metre, shutter sides 0.47 kg per metre and interlock sides 0.45 kg per metre including suitable nylon beading, channel, gasket, nylon rollers, Maruthi lock with handles etc complete all as specified and directed.
S&F powder coated alumunium frame of any size for fixed type window, ventilators with one or more rebates including joining cleats, rubber beading for fixing etc complete all as specified
S&F 5.50 mm thick tinted sheet glass, ordinary quality and glazing with rubber beading exceeding 0.5 Sqm in each pane, complete all as specified and directed by the Engineer-in-Charge.
S&F Powder coated aluminium doors using 96.6 mm X 44.8 mm X 1.60 mm aluminium chowkhat, with 84 mm X 44.7 mm X 1.60 mm section vertical stile, with 101.60 mm X 44.8 mm X 1.60 mm rail mounted on floor door spring with mortice lock (Make- Harrison), with aluminium tower bolts 150 mm long (02 nos), sliding bolt 300 mm long (01 no), door handle 150 mm long (02 nos) and fittings all as directed by Engr-in-Charge. Bottom panel with 12 mm thick laminated nova pan and top panel with 5.5 mm thick plain/froasted sheet glass with rubber beading of suitable size, complete all as specified and directed by Engr-in-Charge.
S&F moveable aluminium anodised powder coated partition run on wheels as all of aluminium section 100mm X 44mm X 2mm thick frame rectangular section & panel of 5mm thick PVC sheet in top & bottom pannel & 5.5mm thick sheet glass in middle panel with rubber linning & aluminium beading around length necessary fixing arrangements for bottom & top member of aluminium frame in floor / PCC /brickwork as per site requirement with rawl plug etc including chromium plated steel screws 60cm c/c including taking down old aluminium partition, complete all as specified.
Material and labour for false ceilings using GI sanp grid system with rool-ormed out of hot drip galvanised steel capings (Powder coated) main runner 38x24mm, cross Tee 29x24mm and wall angle 24x24mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick asbestos designer ceiling board, prepainted cement board size 595x595x4mm thick any texture suspended from from RCC roof/ structural members of soofits angle cleat cut out etc to ther equired line and shape as per manufactureres recommndations at any height complete all as specified and as directed by AGE (I) , Everest ceiling and grid system Regular T-2430 or its equivalent Make of "Everest/Ramco/Charminar/Armstrong"
Taking down AC/CI/PVC SWR pipes 110 mm or 75mm mm bore..
S&F PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc .
S&F PVC (SWR) pipes 75 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc .
S&F PVC SWR floor trap with grating including jointing with solvent cement 75 mm dia.
S&F PVC SWR bends 110 mm dia complete as specified and directed .
S&F PVC SWR bends 75 mm.
S&F steel water tubing, galvanised, medium grade, ISI marked with and including all fittings and fixed on walls and ceilings or in floor bore of pipe 20mm complete all as specified and directed by Engineer-in-Charge.
S&F steel water tubing, galvanised, medium grade, ISI marked with and including all fittings and fixed on walls and ceilings or in floor bore of pipe 15mm complete all as specified and directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position of capacity 1000 litres all as specified in SSR Part-I complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm gate valves gun metal with iron wheel head screwed both ends for iron pipes complete all as specified and directed by Engr in Charge
S&F in repair 20mm gate valves gun metal with iron wheel head screwed both ends for iron pipes complete all as specified and directed by Engr in Charge
S&F in repairs bib taps, cast copper alloy, fancy type with crutchor butterfly handles, chromium plated, screwed down to iron pipes or for brass ferrule of 15mm bore.
S&F in repairs angle valve ,stop valve, cast copper alloy, fancy type, chromium plated with long shank & cup (concealed type) with crutch or butterfly handle, screwed both ends for iron pipe of 15mm bore.
S&F in repairs two way stop valve cast copper alloy,fancy type, chromium plated, with crutch or butterfly handle, screwed both ends for iron pipe 15mm bore complete all as specified and directed by Engineer in charge
S & F in repair 32mm dia aluminium powder coated drapery rod including all necessary fixing arrangement like clamps, end brackets, end to end bracket and eight nos rings per meter complete all as directed and specified.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlarfacings, dressed stonework and precast concrete articles as in portions complete all as specified and directed
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 M mean radius built in CM 1:6 all as specified and directed .
M&L for brick work with sub class 'B' brick , half brick thick wall built in CM 1:4 straight or curved on plan to any radius with old size bricks.
M&L for RCC 1:2:4 using 20 mm graded stone aggregate as in slabs of any thickness above top of footing including attached pilasters and buttress complete all as specified and dirceted
M&L for Formwork to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exc 200mm thick ( horizonla or sloping) for rough finished surface of concrete complete all as specified and directed
M&L for TMT bars 10mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips,
M&L for 20 mm thick granite ( of any type ) work (table rounded and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in 15mm thick cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixer of pigment to match with shade of granite complete all as specified and directed
Taking down cement plaster of any description on brick or concrete surfaces of walls or ceiling etc incl. raking out joints ,hacking for key and scrubbing down with water upto 4 storeys building complete all as specified.
M&L for 15 mm thick cement plaster in cement mortar 1:4 on concrete or brick surface and finished even and smooth w/o using extra cement complete all as directed and specified.
M&L for 12 mm thick cement plaster in cement mortar 1:6 on Bk surfaces on fair face of brick work and finished even and smooth w/o using extra cement complete all as specified.
M&L for 5 mm thick cement plaster in cement mortar 1:3 on concrete or brick surface and finished even and smooth w/o using extra cement as in ceiling complete all as directed and specified.
M&L for preparation of new plastered surface of walls and applying two coats of exterior emulsion paint over a coat of 3mm wall care putty on wall surface as specified and directed by Engr in Charge
M&L for preparation of new plastered surface of walls and applying two coats of interior emulsion paint over a coat of 3 mmm wall care putty with priming paints on wall surface all as specified and directed
M&L for preparation of new surface and applying two coat of white wash on ceiling all as directed and specified.
E/M PORTION
Point wiring using approved color coading as per IS (Red,Black and Green for single phase circuit) with multi stranded copper condutor 1.5 Sqmm nominal cross section area,single core,PVC insulated and unsheathed FRLS cable 1100V grade,ISI-694 marked with valid CML no. in and including medium grade,PVC concealed conduit MMS, ISI marked of dia not less than 20mm and conduilt accessories concealed in wall/roof/floor etc.,ISI marked with valid CML No-(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with terminated to new pressed flush metal readily available cover with outer with plates inner plates etc, suitable for mounting modular type switches , sockets, fan regulators etc incl PVC insulated multistranded copper condutor 1.5 sqmm nominal cross section area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed. Make of cable : RR Kable / Plaza / Finolex / Havells / Polycab. Make of Conduit : Finolex / ICL / Ess Ess Kay / Indo American Electricals Note : Switches and socket to be measured and paid for separately. for the following:-
(a) One light point/one fan point controlled by one SP switch
(b) One socket outlet 5 amps controlled by one switch on same board
(c) One socket outlet 5pin,5/6 Amp On independent board
All as per item No -1 above but point wiring with 2.5 SQMM single core multi sranted copper consductor PVC insulated and unsheathed (FRLS) cable 1100 volts grade and 2.5 SQMM PVC insulated and unsheathed (FRLS) cable 1100 volts grade with multistranded copper conductor as earth wire for 15/16 Amps multi purpose socket combination point on independent board. Make of cable : RR Kable / Plaza / Finolex / Havells / Polycab. Make of Conduit : Finolex / ICL / Ess Ess Kay / Indo American Electricals
S&F modular switch one module, 5/6 Amp, one way, 230 volts AC complete all as specified and directed by Engineer-in-Charge. Make : Anchor Roma / Cone / Crabtree / Legrand / Indo Asian (Glint)
S&F modular switch one module, 15/16 Amp, one way, 230 volts AC complete all as specified and as directed by Engr-in-Charge. Make : Anchor roma / Cone / Crabtree / Legrand / Indo Asian (Glint)
S&F modular socket two module outlet 5/6 amps, 2 in 1, 2 & 3 pin combined, 230 volts AC complete all as specified and as directed by Engr-in-Charge. Make : Anchor roma / Cone / Crabtree / Legrand / Indo Asian (Glint).
S&Fmodular socket out let two module, 2 in 1, 3 Pin suitable for 5/6 Amp and 3 Pin suitable 15/16 Amp combined, 230 volts AC complete all as specified and as directed by Engr-in-Charge. Make : Anchor roma / Cone / Crabtree / Legrand / Indo Asian (Glint)
S & F ceiling rose, 3 phase, PVC / polycarbonate, surface type, 65mm x 50mm, insulated body, three terminal complete all as specified and as directed by Engr-in-Charge. Make : Anchor / Ess Ess Kay / Havells.
S & F Modular fan regulator, 120 Watt, 230 volts, 2 modules complete all as specified and directed Make : Anchor roma / Cone / Crabtree / Legrand / Indo Asian (Glint)
S& F lamp holder, PVC/polycarbonate type, insulated body with back plate of batten fitting complete all as specified and as directed by Engr-in-Charge. Make : Anchor / Ess Ess Kay / Plaza / Havells
Supply and fixing of surface and wall mounted LED batten with aluminium housing provided for efficient heat dissipation with polycorbanate diffuser and integrated electronic driver LED tube light fitting 20 watt including LED tube, 230 volt complete all as specified and directed by Engr-in-charge. Make :Havells cat part No ENDURA LINEARNEOBS20WLED830SPCWH or equivalent model of make Phillips / Wipro
Supply and fixed LED recessed mounting square slim LED down lighter 36 Watt for AS/GB/POP ceiling 2'x2' size complete with internally prewired and connecting up with twin core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge. Make : Havells cat part No VENUSNEOHE2X2PL218-42WLED857HOD and Driver cat Part No. LEDDRIVER36V36WS or eqt Syska/Phillips.
S&F LED mirror light fitting, plastic body 1x17 Watt attractive, wall mounted suitable for mirror light fittings with electronic driver etc. complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size Complete all as specified and as directed.Make:- Philips 919215850332 17-Watt Wall Light (Warm White, Round)
S & F of TP&N Vertical Loadline DBs are fitted with Bus Bars, Neutral Links, Blanking Plates (without MCCB) Distribution Board, ISI Marked, TP&N Vertical Loadline 4 Way with metal double door concealed flush in wall manufactured prewired IP-43- IK-09 made out of 16SWG sheet suitable for fixing MCCB as incomer and MCBs out going rated bus bar, neutral link, din rail suitable for mounting MCB's including making good distrubed surface complete all as specifed and directed. MAKE: Cat No DHDLVDRWGOFO04 (DB LL 4 Way DD VERT W/O MCCB) of Havells /L & T/Legrand
S & F of MCB TPN metalic distribution board, TPN 4 way, 415 Volts AC, double door type of sheet steel phosphotised powder painted with 200 Amps, neutral bars, earth bar concealed flush in wall IP-43 including making good distrubed surface all as specified and directed. MAKE: Cat No DHDNTHODAW04 of Havells /L & T/Legrand.
S & F of MCB SPN metalic distribution board, SPN 12 way, 240 Volts AC, double door type of sheet steel phosphotised powder painted with 200 Amps, neutral bars, earth bar IP 42 protection concealed flush in wall including making good distrubed surface all as specified and directed. MAKE: Cat No DHDNSHODAW12 of Havells /L & T/Legrand
S & F of MCCB 4 pole 415 volt, 50 HZ,125Amps ,16 KA.Fixed Thermal & Fixed Magnetic setting | Ics = 75% of Icu, including all necessary lugs thimble all etc all as specified and as directed. Make of Havells model No IHLGNF0125 or Equivallent Make of Legrand/ABB
Supply and fixing of MCB Ttiple pole and neutral, 240 volts, 63 amps breaking capacity 10KA, ‘C’ Series. etc , complete all as specified and directed. Make of Havells model No DHMGCTNF063 or Equivallent Make of Legrand/Scheinder
Supply and fixing of MCB single pole and neutral, 240 volts, 63 amps breaking capacity 10KA, ‘C’ Series. etc , complete all as specified and directed. Make of Havells model No DHMGCSNF063 or Equivallent Make of Legrand/Scheinder.
Supply and fix MCB single pole 240 volts, 6 to 32 amps, 50HZ, 10 KA. , ‘C’ series complete all as specified and directed. Make of Havells model No DHMGCSPF006-032 or Equivallent Make of Legrand/Scheinder
Supply only sheet metal enclosure single pole and neutral with two pin earth plug and socket complete with one single pole MCB 20 Amp 240 volts half grouting on wall all as specified and directed. Make : Legrand / C&S / Havells / L&T / ABB
Material and Labour for sub main wiring complete with 4 single core multi stranded copper conductor 10 sqmm (Nominal area) PVC insulated unsheathed cable drawn in and including medium grade PVC conduit ISI Marked not less than 25 mm dia concealed, including making good distrubed surface, of wall, including one single core multi stranded copper conductor 10.0 sqmm size as earth wire drawn in same conduit complete all as specified and directed . (a) Four single core 10.00 sqmm size sub main wiring with one single core 10.00 sqmm size earthwire drawn into and including one run 25 mm or higher dia PVC conduit medium grade fixed concealed. (b) Four run of 10 sqmm copper cable and one run of 10 sqmm copper cable (earth wire) alongwith one metre of PVC conduit measured as one unit. (c) Extra length of cable required for connetion to DBs shall deemed to be included in the unit quoted rate and shall not be measured separately. (d) Suitable colour code of wire shall be maintained for phase / neutral / earth).
Material and Labour for sub main wiring complete with 2 single core multi stranded copper conductor 6 sqmm (Nominal area) PVC insulated unsheathed cable drawn in and including medium grade PVC conduit ISI Marked not less than 25 mm dia concealed, including making good distrubed surface, of wall, including single core multi stranded copper conductor 6.0 sqmm size as earth wire drawn in same conduit complete all as specified and directed . (a) Two single core 6.00/4.00 sqmm size sub main wiring with one single core 6.00/4.00 sqmm size earthwire drawn into and including one run 25 mm or higher dia PVC conduit medium grade fixed concealed. Note : (a) Two run of 6/4 sqmm copper cable and one run of 6/4 sqmm copper cable (earth wire) alongwith one metre of PVC conduit measured as one unit. (b) Extra length of cable required for connetion to DBs shall deemed to be included in the unit quoted rate and shall not be measured separately. (c) Suitable colour code of wire shall be maintained for phase / neutral / earth).
M&L for submain wiring with two single core 4 sq mm PVC insulated FRLS multistrand copper conductor cable drawing into and including rigid non metallic PVC concealed conduit ISI marked with all fittings & fixing accessories and one single core 4.0 Sqmm FRLS multistrand copper conductor cable as continuous earth wire complete all as specified & directed by-in-Charge. (a) Two single core 6.00/4.00 sqmm size sub main wiring with one single core 6.00/4.00 sqmm size earthwire drawn into and including one run 25 mm or higher dia PVC conduit medium grade fixed concealed. Note : (a) Two run of 6/4 sqmm copper cable and one run of 6/4 sqmm copper cable (earth wire) alongwith one metre of PVC conduit measured as one unit. (b) Extra length of cable required for connetion to DBs shall deemed to be included in the unit quoted rate and shall not be measured separately. (c) Suitable colour code of wire shall be maintained for phase / neutral / earth).
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to earth lead wire of GI wire 4mm dia by means of nuts/bolts and washers, check nuts of galvanized iron or steel including 15mm dia GI pipe light grade upto 1.5 mtr below GL for protection pipe, excavation and earth work charcoal dust, common salt, PCC 1:3:6 type C-1 chamber with cover and RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm c/c both way with MS handle 12mm dia PGI funnel and wire mesh all as shown in electrical plate No 5 of SSR Part-I connected to ear thing test point all as specified or indicated including testing on completion all as directed by Engr-in-Charge.
Supply and laying or fixing or passing through existing duct/pipe, 1100 Volts grade heavy duty XLPE cable with PVC armoured aluminium conductor served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and over all PVC sheathed 50 Sq mm 3.5 core nominal cross section stranded conductor complete all as specified and directed
Supply and lay G.I pipe Light grade with all fittings required for protection of under ground cable including cutting of road surface wherever required and making good to match with existing surface of size 50 mm dia all as specified and directed
Hira Singh and Sons
garnet engineers contractors
S D Constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .