Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹48.3 L+₹4.2 L (9.48%)Rejected-Finance B BLOCK 2 3 RAM BACHAN V B NAGAR PIPE ROAD KURLA W MUMBAI 400070 | MUMBAI SUBURBAN | MAHARASHTRA | 400070 | L2 | Rejected-Finance BEING OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
2 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR REPLACEMENT OF EXISTING FITTINGS AND FIXTURES WITH MODULAR FITTINGS IN CERTAIN SAILORS MARRIED ACCN AND OTM OF LOW RISE BLDGS AT OLD AND NEW NAVY NAGAR UNDER GE NW NAVY NAGAR COLABA MUMBAI
2022_MES_566203_1
8104/CWE (NW) Mumbai/ E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) Navy Nagar
Class D
7 documents required · 7 mandatory
₹500
Yes
GE (NW) Navy Nagar
₹90,000
Yes
14 Feb 2023
30 Nov 2022
4 Jan 2023
30 Nov 2022
2 Jan 2023
14 Dec 2022
30 Nov 2022 - 12 Dec 2022
Amount
Taking down carefully copper/ aluminium point wiring i.e. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors, etc complete all as specified and directed by Engineer-in-Charge
Material and Labour for point wiring with PVC insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLS, passing through PVC casing caping including accessories and provision of PVC box for mounting of modular Switchs & Sockets as required at site as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) FRLS earth wire and connected to earth dolly for the following complete all as specified and directed by Engineer-in-Charge:- NOTE : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm.
One light/Exhaust/Ceiling fan point controlled by one switch complete all as specified and directed by Engineer-in-Charge
One 3 pin switch socket combination 5 Amps on the same board with other switches complete all as specified and directed by Engineer-in-Charge
One 3 pin switch socket combination 5 Amps, independent complete all as specified and directed by Engineer-in-Charge
One bell point controlled by one push button complete all as specified and directed by Engineer-in-Charge
All as per item No 2.00 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch complete all as specified and directed by Engineer-in-Charge
Supply and Fixing in replacement with modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as specified and directed by Engineer-in-Charge
Supply and Fixing in replacement with modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as specified and directed by Engineer-in-Charge
Supply and Fixing in replacement with ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm complete all as specified and directed by Engineer-in-Charge
Supply and Fixing in replacement with modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as specified and directed by Engineer-in-Charge
Supply and Fixing in replacement with modular socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as specified and directed by Engineer-in-Charge
Supply and Fixing in replacement with modular bell push switch, 1 module, single pole one way 6Amp ISI marked complete all as specified and directed by Engineer-in-Charge
Supply and Fixing in replacement with modular electric bell ding dong, AC, 230V single pole complete all as specified and directed by Engineer-in-Charge
Supply and Fixing in replacement with modular stepped type fan regulator, 2 module, single pole one way ISI marked complete all as specified and directed by Engineer-in-Charge
Supply & Fixing Retrofit LED lamp 7 Watts complete all as specified and directed by Engineer-in-Charge
Supply & Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in-Charge
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and Supply and Fixing modular PVC Gang box, screwless of 8 module for mounting of modular switches and sockets including blank plate for blank module complete all as specified and directed by Engineer-in-Charge
All as per Item No- 14.00 above but of modular PVC Gang box, 6 module complete all as specified and directed by Engineer-in-Charge
All as per Item No- 14.00 above but of modular PVC Gang box, 3 module complete all as specified and directed by Engineer-in-Charge
All as per Item No- 14.00 above but of modular PVC Gang box, 2 module complete all as specified and directed by Engineer-in-Charge
All as per Item No- 14.00 above but of modular PVC Gang box, 1 module complete all as specified and directed by Engineer-in-Charge
Supply and Fixing modular white cover plate with frame, 8 module complete all as specified and directed by Engineer-in-Charge
Supply and Fixing modular white cover plate with frame, 6 module complete all as specified and directed by Engineer-in-Charge
Supply and Fixing modular white cover plate with frame, 3 module complete all as specified and directed by Engineer-in-Charge
Supply and Fixing modular white cover plate with frame, 2 module complete all as specified and directed by Engineer-in-Charge
Supply and Fixing modular white cover plate with frame, 1 module complete all as specified and directed by Engineer-in-Charge
Taking down unserviceable FTL/batten fittings with supply and fixing LED Aluminium housing of batten fitting 20 Watt, 240V, 4ft CDL/NW comprises of aluminium extruded channel in thermally conductive material with decorative end cap and high translucent serration milky white diffuser of high optically efficient plastic FR grade. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose. The contractor shall provide test certificate from authorized lab complete all as specified and directed by Engineer-in-Charge
Taking down unserviceable FTL/batten fittings with supply and fix LED integrated polycarbonate housing of batten of 10 Watt 2ft LED give minimum output lumen 1150 lm, efficiency >110, CCT 4000/6500K, CRI >80, power factor >0.9, operating temperature 45 degree celcious, THD <20% of housing polycarbonate extrusion with LED dimension 603mmx22mmx36mm upto 50% energy saving complete all as specified and directed by Engineer-in-Charge
Taking out any type of FTL fitting and Supply and Fixing 10W LED batten with inbuilt smart motion sensor, 230 Volt , 50 Hz , 2 feet, polycarbonate extruded channel, powder coated with diffuser for glare free light, Inbuilt motion sensor prewired with 25% dimmer illuminous in ideal time with all accessories including two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose complete with following specification. (i) housing-polycarbonate extrusion,diffuser- opal- polymer, LED type- MID power ,Light distribition- general Spread, LED efficiency - > 130 lumen/Watt, System effieciency- > 100 lumen/Watt, Driver efficiency - more than 85%, power factor- more than 0.95, THD - <10%, Mounting/Fixing- Wall/Ceiling, Ingress Protection - IP-20, Sensor type- HF inbuilt integral occupancy/movement sensor, sensor range- upto 5 mtrs(cone formation ), Dimming operation- default operation at 25% of the is rated value. On detection of motion, light output rises to 100% for upto 20 sec . in absence of otion switches back to default operation, LED life- upto 30,000 Hrs.Surge Protection- not less than 2KV. Note:- (i) contractor shall submit LM79 report LM 80Test certificates before claiming for payment .(ii) Warranty certificate for minimum 2 years to be submitted from OEM.
Supply and Fixing MCB DB SPN conforming to IP 43 - IK 09 with acrylic door, 8 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces by plastering or PCC work including distempering to the affetced to walls complete all as specified and directed by Engineer-in-Charge
Taking out Old Unserviceable and Supply and Fixing MCB SPN, 32 Amp, 10 KA, 230 Volt complete all as specified and directed by Engineer-in-Charge
Taking out Old Unserviceable and Supply and Fixing MCB,single pole, upto 20 Amp, 10 KA, 230 Volt complete all as specified and directed by Engineer-in-Charge
Taking out unserviceable ceiling fan and deposit to MES Store, supply and replacement with ceiling fan 230V, 50 Hz, AC, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge
Taking out unserviceable exhaust Fan and deposit to MES Store, supply and replacement with exhaust fan, 4 blade, heavy duty, double ball bearing, 230V, 50Hz, 300mm sweep having power input 70W speed 1440RPM, with protective bird guard including connecting with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge
Taking out & Overhauling of ceiling fan any size and Make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover etc and assembling and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076 including one coat of painting and testing after refixing at site complete all as specified and as directed by Engr-in-Charge. Note: Rate of petty items to be replace shall be included in quoted rate.
Taking out & Overhauling of Exhaust fan any size and Make, dismantling parts, properly cleaning/removing old existing grease, oil and applying new oil grease, varnishing for winding, cleaning dust, rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover etc and reassembling, connecting with copper conductor multi stranded 3 core wire of size 14/0.0076 including one coat of painting complete and testing after refixing at site complete all as specified and directed by Engineer-in-Charge Note: Rate of petty items to be replace shall be included in quoted rate.
Taking down deteriorated louvers and supply and fixing new louvers fixed type made out of 1.6mm GI sheet with horizontal ventilation, bending into shape of size 45cmx45cm (outer) with 20x3mm flat iron base of size 45cmx45cm complete by providing of fixing arrangement for louvers upto 5th floor of including rate complete all as specified and directed by Engr-in-Charge
Supply and Fixing cable PVC insulated, PVC sheathed, armoured, FRLS, 1100V grade, 2 core 6 sqmm stranded copper conductor electric cable laid on wall/ roof/ duct complete with proper saddling and connecting to DBs with glands including taking out existing unserviceable cable complete all as specified and directed by Engineer-in-Charge
Supply and Fixing in relplacement with new cable PVC insulated three core over all PVC sheathed 2.5 Sqmm stranded copper conductor cable for connection from DB to connector junction box for power supply to security light fittings drawn in PVC conduit not less than 20mm including taking out old one complete all as specified and directed by Engineer-in-Charge
Supply and Fixing junction box of size not less than 4x4 inch with connector encloser, 3 terminal/ PVC/ polycarbonate, isolated body including taking out old one complete all as specified and directed by Engineer-in-Charge
Supply and Fixing street light bracket bend to shape made as required of 40mm dia 1.0 mtr long GI pipe light grade fixed to pole/ Wall including Material and Labour for fixing with the help of flat iron clamp of size 40x6mm two numbers with the help of nuts and bolts for fixing of street light fitting on the wall complete after taking out old U/S one complete all as specified and directed by Engineer-in-Charge
Taking out old unserviceable security light fitting and Supply and Fixing new bldg security light 60 watt with inbuilt smart motion sensor with 25% dimmer illuminous in ideal time with all accessories comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 60 watt roadway luminaire type with ingress protection IP 65/66 and SPD of capacity 10 KV etc complete with following specification. (i) housing- epoxy powder coated housing, enclosed with glass cover , LED type- High Power LED ,Light distribution- Bat wing, LED efficiency - > 130 lumen/Watt, System effieciency- > 100 lumen/Watt, Driver efficiency - more than 85%, power factor- more than 0.95 to 0.98, THD - <10%, Mounting/Fixing- GI Bracket, Ingress Protection - IP-65/66, Sensor type- HF inbuilt integral occupancy/movement sensor, Sensor type – Dusk Dawn sensor mounted on LED PCB, sensor range- upto 5 mtrs(cone formation ), Dimming operation- default operation at 25% of the is rated value. On detection of motion, light output rises to 100% for upto 20 sec . in absence of motion switches back to default operation, LED life- upto 50,000 Hrs. Surge Protection - 4 to 10 KV. Note:- (i) contractor shall submit LM79 report LM 80Test certificates before claiming for payment .(ii) Warranty certificate for minimum 2 years to be submitted from OEM complete all as specified and directed by Engineer-in-Charge
Taking out old ceiling light fitting and Supply and Fixing 36W LED ceiling light with inbuilt smart motion sensor, 230 Volt , 50 Hz , 2x2 feet, CRCA sheet metal power coated with diffuser for glare free light, Inbuilt motion sensor prewired with 25% dimmer illuminous in ideal time with all accessories with following specification. (i) housing-Aluminium Extrusion,diffuser- opal,sensor type- HF inbuilt integral occupancy/movement sensor, LED type- MID power, Light distribition- general Spread, LED efficiency - > 130 lumen/Watt, System effieciency- > 100 lumen/Watt, Driver efficiency - more than 85%, power factor- more than 0.95, THD - <10%, Mounting/Fixing- recess mounting, Ingress Protection - IP-20, sensor range- upto 5 mtrs(cone formation ), Dimming operation- default operation at 25% of the is rated value. On detection of motion, light output rises to 100% for upto 20 sec. in absence of option switches back to default operation, LED life- upto 50,000 Hrs.Surge Protection- not less than 4KV. Note:- (i) contractor shall submit LM79 report LM 80Test certificates before claiming for payment .(ii) Warranty certificate for minimum 2 years to be submitted from OEM. complete all as specified and directed by Engineer-in-Charge
Supply and Fixing in replacement of 20 watt LED RGB under water light IP68 luminaire, size - 190mmx250mm with stainless steel housing with driver including necessary stand for fixing of fountain light with mounting base including making all electrical connection complete all as specified and directed by Engineer-in-Charge
All as per item No - 41.00 above but LED RGB under water, 12 watt complete all as specified and directed by Engineer-in-Charge
Supply and Fixing in replacement for surface of wall light 8 watt on wall complete all as specified and as directed by Engnr-In-Charge.
Supply and Fixing in replacement for Seat light of suitable watt on seat complete all as specified and as directed by Engnr-In-Charge.
Supply and Fixing in replacement for track light 12 watt on surface complete all as specified and as directed by Engnr-In-Charge.
Supply and Fixing in replacement for track rail on wall complete all as specified and directed by Engineer-in-Charge
Supply and Fixing in replacement of surface mounted round safe LED downlight 12 watt with aluminium die-cast body, finish with drop down PC diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation including making all electrical connection complete all as specified and directed by Engineer-in-Charge
Supply and Fixing in replacement of surface mounting LED 36 watt, 4x1 luminaire to enhance the delight of occupants with comfortable experience through its classic design & glare free soft illumination. White powder coated CRCA housing, seamless front frame with flat white high transmission acrylic cover including making all electrical connection complete all as specified and directed by Engineer-in-Charge
Taking down unserviceable FTL and supply and fix Suspension (Pendant) luminaires with efficient Diffuser ensuring perfectly uniform illumination, ensured optimised and unparalleled light distribution LED pendant luminare 20 Watts, 4 ft, box type complete with powder coated CRCA decorative body complete with hanging arrangement complete all as specified and directed by Engineer-in-Charge
Taking down old Unserviceable Highbay Luminaire with aluminium die cast housing for efficient Thermal Heat management and secondary modular lens Optics for optimized Lighting distribution to improve operational efficiency, with EMC/ EMI Complient Potted Driver, Flicker free Illumination highbay lights and Supplying and fix LED 120 Watt Highbay luminaire with diffuser including making all electrical connection complete all as specified and directed by Engineer-in-Charge
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 200 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion complete all as specified and directed by Engineer-in-Charge
Material and labour for snap-on adaptable trunking system with cover, angles, bends and all accessories and fitting of size 50x80mm on wall complete all as specified and directed by Engineer-in-Charge
Taking down unserviceable and Supply and Fixing for dividers of snap-on trunking system on wall complete all as specified and as directed by Engineer-In-Charge.
Taking down unserviceable and Supply and Fixing for internal (varies from 80° to 100°), external (varies from 85° to 120°) & Flat (flat angles at 90°) type angles of snap-on trunking system on wall complete all as specified and as directed by Engnr-In-Charge.
Taking down unserviceable and Supply and Fixing for cover of snap-on trunking system on wall complete all as specified and as directed by Engnr-In-Charge.
Taking down unserviceable and Supply and Fixing for cover joints of snap-on trunking system on wall complete all as specified and as directed by Engnr-In-Charge.
Taking down unserviceable and Supply and Fixing for end caps of snap-on trunking system on wall complete all as specified and as directed by Engnr-In-Charge.
Material and labour for DLP PVC trunking system with cover, angles, bends and all accessories and fitting of size 32x12.5mm on wall complete all as specified and as directed by Engineer-In-Charge. Make Legrand Cat No- 0300 15 or as approved by GE.
Taking down unserviceable and Supply and Fixing for end cap left or right of DLP PVC truncking system on wall complete all as specified and as directed by Engnr-In-Charge.
Taking down unserviceable and Supply and Fixing for Changeable internal - external angle from 60° to 120° of DLP PVC truncking system on wall complete all as specified and as directed by Engnr-In-Charge.
Taking down unserviceable and Supply and Fixing for Changeable flat angle from 85° to 95° of DLP PVC truncking system on wall complete all as specified and as directed by Engnr-In-Charge.
Taking down unserviceable and Supply and Fixing for flat junction of DLP PVC truncking system on wall complete all as specified and as directed by Engnr-In-Charge.
Taking down unserviceable and Supply and Fixing for White 32 x 10/12.5 Cover Gasket of DLP PVC truncking system on wall complete all as specified and as directed by Engnr-In-Charge.
Supply and Fixing in replacement of High performance LED Downlights 12 watt for commercial applications 100 lumen/watt efficacy efficient heat sink (die cast) with steel clips integrated driver control on surface complete all as specified and as directed by Engnr-In-Charge.
Supply and Fixing in replacement of robust & reliable IP66 & IK08 protected LED midway with PVC housing & toughned glasssuitable for ceiling (surface/suspended) mount of beam light 12 watt for commercial applications 100 lumen/watt efficacy efficient heat sink (die cast) with steel clips integrated driver control on surface complete all as specified and as directed by Engnr-In-Charge.
Genius Construction Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .