Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹18.5 L+₹1.2 L (6.84%)Rejected-AOC RZ BH 4 STREET NO 5 MAIN SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L2 | Rejected-AOC L2 | |
| 3 | L3₹21.9 L+₹4.6 L (26.3%)Rejected-AOC 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L3 | Rejected-AOC L3 | |
| 4 | L4₹28.3 L+₹11.0 L (63.5%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹48,520
Closing Date
6 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) TUGHLAKABAD
HQ CWE (AF) TUGHLAKABAD
PROVN OF ELECTRICAL CONNECTION AND AMMENITIES FOR PECHORA DIGITIZATION AT AF STN TUGHLAKABAD UNDER GE (AF) TUGHLAKABAD (PHASE-II)
2021_MES_480035_1
CA NO. CWE/TKD/TOKEN-41/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) TUGHLAKABAD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (AF) TUGHLAKABAD
₹48,520
Yes
4 Mar 2022
6 Oct 2021
8 Nov 2021
6 Oct 2021
6 Nov 2021
18 Oct 2021
60 days
Amount
Supply, installation,testing and commissioning the following indoor type, 11 kV 3 phase, 50 cycle (50 Hz) 630 Amps capacity tripple pole totally enclosed pattern, vermin proof vertical draw out type with grounded neutral system Vaccum Circuit Breaker, floor mounted with common copper tinned bus bar complete all as per following details :- (i) One set of 3 phase 1250 Amps air insulated tinned copper bus bar with insulated colour coating. (ii) One set of side frame for housing of circuit breaker carriage. (iii) One 630 Amps tripple pole minimum 350 MVA (3 sec) rupturing capacity with latest issue of IEC recommandation: EC 62271 100 vaccum restrike free stored energy oprated type, mechanical anti pumping should be built in future of circuit breaker. VCB with automatic drop out and motor operated spring closed mechanism complete with auxiliary switches trunk type meachanically ON OFF indicators. (iv) The breaker is to be mounted on trunk carriage complete with self contained motor charged spring closing mechanism to be operated on DC motor 24V/30V operated fully interlocked raising and lowering mechanism. (v) Cable box for reception for suitable size XLPE 3 core UG cable 11000 volt pressure. (vi) CT details:- (i) Single phase, 2 core CT with 100-50/5-5-03 Nos, Core I Class-I, 15VA, 10 Core II Class 5P10, 15 VA Core Il Class 5P10, 15 VA (vii) Digital intelligent panel meter indicating line current, line voltage, power factor, KVAR, KVA, frequency, voltage and harmonics etc with accuracy 1.0 for active energy. (viii) Micro processor based numerical relay for over current and earth fault protection, self powered type with inbuilt software, USB port, SCADA compatible for remote communications with provision of recording of at least 15 faults complete all as directed. (ix) Prown of 24/30 V, 3 Phase DC tripping system with SIREN / HORN and accept switch and over voltage under voltage protection RELAY.
Item No-01 contd/......... (x) One No Volt Coil to trip the VCB on failure of electric supply. (xi) 230 volts, AC, single phase, 80 watt reted strip heater with switch and thermostale for space heating. '(xii) Breaker panel indication amps shall be providedd for following functions :- (a) Breaker ON-01 No Green colour. (b) Braker OFF-01No, Red Colour (c) Auto Trip Indication-03 Nos Blue colour (d) Hand operated / charged independent closing/spring tripping, trip free, operating mechanism with mannual closing & tripping push button & mechanical breaker dosed / Open" spring charged/discharged indications. (xiii) Switche and other accessories :- (a) Circut breaker control switch-01 Nos. (b) Alarm Bell - 01 Nos. (c) Heater with heater switch & thermostate-01 No. (d) Cubical illumination lamp -01 No. (e) 15 A, 230 V, 3 Pin Plug & socket-01 No (xiv) Mechanical operation counter. (xv) Shunt trip coil of 24 / 30 volts Dc as ordered / required at site. (xvi) Breaker operated auxiliary switches (NO&NC)-04 Nos (xvii) One set of potential transformer as per latest IS horizontal draw out type with suitable capacity of HT PT fuse 11000 V of appropriate current for 3 phase, 11 KV vacume circuit breaker including all electrical connection and connected works. NOTE :- Any addition/alteration or VCBs of existing switch gears required to install the new VCB including required bus bar, connecting pieces, anodised brass nuts & bolts, ducting work is deemed to be included under the same and NO additional payment will be made to the contractor on this account. Make: Siemens/Crompton Greaves/ ABB/Areva T&D Ltd/C&S Electric Ltd/ Kirloskar/Schneider Indian Transformer & Electricals
Supply and fixing Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 300 KVA complete all as specified and directed..
M&Lfor earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip of size 32 x 6 mm by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth strip protected by galvanized iron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 3 of SSR-2009 (Part-I). Note :-The earth value/result should be less than 5 ohms.
S&F earth continuity conductor or main earthing strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc., as required 32 X 6 mm galvanised iron strip complete all as specified and directed.
Supply, laying and testing cable in duct/ trench XLPE insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sqmm 3½ core complete all as specified and directed.
Supply and installation of copper wound transformer indoor/outdoor type 315 KVA, 415/230 V (fixed ratio) 3 phase 50 Hz air cooled oil immersed copper wound indoor type step down cum isolation transformer complete with first filling of IS: 335 ISI marked filter & dehydrated transformer oil electro static sheild between primary 415V in delta connected & secondary 230 V star connected complete & other standard fitting / accessories with vector group symbol Dyn-11 complete all as specified and directed. Note:- The rate for PCC plateform with cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate with top finish even and smooth.
M/s ELECTROSHINE ENGINEERS
Neeraj Enterprises
Deep Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .