Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹21.0 L+₹6.5 L (44.4%)Rejected-Finance | L2 | Rejected-Finance Rates are high | |
| 3 | L3₹22.9 L+₹8.3 L (57.4%)Rejected-Finance 10 2 NARAYAN BAG INDORE M P | L3 | Rejected-Finance Rates are high | |
| 4 | Rejected-Technical | - | Rejected-Technical No due to non category in the particular work |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
24 Dec 2019, 12:00 pmClosed
GE MIS MHOW
GE MAINT INF SCHOOL, 75 MALL ROAD MHOW
REPAIR MAINT IMPROVEMENT OF SUMMER APPLIANCES LIKE SPLIT WINDOW TYPE AIR CONDITIONERS WATER COOLER REFRIGERATOR DEEP FREEZER UNDER GE MAINT INF SCHOOL MHOW
2019_MES_302256_1
GE MIS MHOW/42 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
GE MIS MHOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE MIS MHOW
₹30,000
Yes
12 Jun 2020
29 Nov 2019
26 Dec 2019
7 Dec 2019
24 Dec 2019
14 Dec 2019
Amount
AIR CONDITIONER WINDOW/SPLIT TYPE 1.5/2 TON
M&L Removing the burnt/defective sealed compressor unit of any make from any type of air conditioner capacity 1.5Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing of new sealed compressor unit make - Tecumseh Kirloskar, Model RNB 5521 of rotary compressor by tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as directed at site.
All as per item No 2 hereinbefore above but Air conditioner of 2 ton capacity and sealed compressor unit Make - Tecumseh Kirloskar, Model RNB 5529 complete all as directed at site.
M&L Removing the burnt/defective sealed compressor unit of any make from any type of air conditioner capacity 1.5Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing of new sealed compressor unit make - Kirloskar, Model AE 5522E or CR 22K 6 M /AW 1500 by tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as directed at site.
All as per item No 4 hereinbefore above but Air conditioner of 2 ton capacity and sealed compressor unit complete all as specified and direct ed at site. Make - Tecumseh, Model AW-2000
Testing and Repairing leakage in system Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 1.90 Kg) complete.
All as per item No 6 hereinbefore above but Air conditioner of 2 ton capacity complete all as specified and direct ed at site. gas F-22 (approx 2.30 Kg) complete.
S&F in replacement of electric blower motor capacity 1/7 HP SP 230V, 50Hz, 930/875/825/775 RPM for window type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site.
S&F in replacement of electric blower motor capacity 1/8 HP SP 230V, 50Hz, 1350 RPM for 2 Ton capacity split type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site.
S&F in replacement of electric blower motor capacity 1/13or 1/10 HP SP 230V, 50Hz, 1450 RPM for Split type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site.
S&F in replacement of electric blower motor capacity 1/5 HP SP 230V, 50Hz, 930 RPM for window type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and direct ed at site.
Supply & fixing in replacement thermostat for window type AC, working on SP, 230V,AC Make : Indfos/ Ranutrol, complete all as directed at site.
Supply & fixing in replacement of PCB circuit with remote control for air conditioner of any Make and capacity complete all as specified and direct ed at site. Make : Voltas/Carrier/Ranutrol/LG/Blue star
Supply & fixing in replacement air filter for split type Air conditioner (set of three Nos) Make-Marcon or Equivalent complete all as specified and direct ed at site.
Supply & fixing in replacement air filter washable of Nilon mesh suitable for window type air conditioner complete all as specified and direct ed at site. Make : Marcon
Supply & fixing in replacement starting capacitor 150 to 200 MFD, 440 volts AC ( Suitable for 2 TR split AC) complete all as specified and direct ed at site. Make : Asian/Empire
Supply & fixing in replacement starting capacitor 100 to 120 MFD, 440 volts AC ( Suitable for 1.5 TR window type AC) complete all as specified and direct ed at site. Make : Asian/Empire
Supply & fixing in replacement running capacitor 36/45 MFD, 440 volts AC ( Suitable for 1.5 TR window AC) complete all as specified and direct ed at site. Make : Asian /Empire
Supply & fixing in replacement capacitor 6 MFD, 440 volts AC ( Suitable for fan motor) complete all as specified and direct ed at site. Make : Asian /Empire
Supply & fixing in replacement relay box type model-KCH 5230004 Make : Usha/Arvind/Voltas
Supply and fixing of copper filter pencil type to any make and capacity of air conditioner complete Make : Vaishali Metal complete all as specified and directed.
S&F in repair front grill of PVC for window type AC of any make complete all as specified and direct ed at site. all as per existing grill
Supply and fixing relay over load protector complete set suitable for AC complete all as specified and direct ed at site.
Supply & fixing in replacement relay box type model-AC85004 /AC 85001 operating on SP 230 Volt, AC, Make : Usha/Arvind/Voltas
SHIFTING OF AC's
M&L for taking down split type AC complete with connectted electric wires, copper tubing, insulation sleeves, outdoor fitting bracket from exiting place and the same fitted to as per requirement/ handed over site,and after fitting complete AC from one place to another place, find leakage in system by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including copper tubing up to 2 running mtr (in replacement), after exceeding 2 Running mtr it 9 Copper tubing) should measured and paid separately, cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 8 Kg) in air conditioner 1.5 Ton to 2.0 ton completeall as per directed by Engr-in Charge
Supply & fixing in replacement cable PVC flexible copper conductor 3 core heavy duty 4.0 Sqmm complete all as specified and direct ed at site. Make : Plaza/Finolex/ ISI mark
M&L Checking the unserviceable plant (such as AC window type/split type of any capacity, Desert cooler etc) of any make, size and capacity, making it serviceable by tightening the connection, checking power point /socket point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- Petty stores such as insulation tape, screws, small pieces of wires, etc shall be provided by the Contractor. Cost of the same is deemed to be included in the quoted unit rate. .
S&F in repairs Copper tubing of following size complete:-
(a) 3/8” size
(b) 5/8 ” size
(c) 1” size
(b) 1/4 ” size
(c) 1/2” size
Supply and charging of gas Freon - 22 in AC plant of any capacity Note:- Gas will be accepted in sealed and tested cylender having weight of gas 13.6 Kg in each cylender.
Repair of existing operating pannels of air conditioner of capacity 7.5/11 TR and making complete incoming and outgoing connections complete all as specified and directed by Engr-in-charge.
M&L for profile insulation of outdoor unit complete all as specified and directed.
S&F of AC contactor three phase 415-660 volts 32 Amps coil voltages 230 Volt as per sample complete all as specified and directed.
S&F of following parts and fixed complete all as specified and directed.
a). Hand shut valve of size 5/8" Make- Synergn
b). Pressure gauge (0-500 PSI)
c) Valve 3 way
d). Flair nut 3/4" brass
e). Dead plug (brass)
f) Union
S&F MCCB four pole 63 Amp 16 KA 415 volts complete all as specified and directed Make- HPL/Havells
S&F in repairs Sheet metal inclosure with earth plug and socket single pole and neutral with single pole MCB 20 Amps 240 volts complete all as directed. Make:- HAVELL's or equivalent in Legrand/Standard.
S&F in repairs Metal clad plug, 2 pole with earth terminal capacity 20 Amp fixed in existing single pole and neutral enclosure complete.
S&F in repairs Metal clad socket, 2 pole with earth terminal capacity 20 Amp, fixed in existing single pole and neutral enclosure complete.
S&F in repairs MCB SP, 240 volts, 5-32 Amps, 10KA breaking capacity, 'C' type including connection with suitable size almuminium /copper lugs complete all as directed
M&L Plug top, 3 pin, 15 Amp, SP, 230V, fixed in repairs complete.
M&L Switch socket combination piano type 5/15 Amp, 230 volts AC, fixed in repairs complete.
DESERT COOLERS
Supply & fixing in replacement fan motor assembly of 1/7HP, 230V SP, AC complete clamps=04 Nos and water fan 18" sweep Make GE Motors/Auc/Crompton/ISI Mark complete all as specified and direct ed at site.
Supply & fixing in replacement vertical pump/Water mersed pump complete tube operated on SP 230V AC Make : Crompton/cool- Home/GE Motors/ISI Marked complete all as specified and direct ed at site.
Supply & fixing in replacement wood-wool pad complete heavy size (set of three pads) Approx wt 400 Gms complete all as specified and direct ed at site.
Supply & fixing in replacement capacitor 6 MFD, 440V, Make - Empire/ EPCOS/ Capro/ Asian or ISI Mark complete all as specified and direct ed at site.
M&L Scrapping down the complete existing paint inside and out side of desert cooler cleaning the surface and applying two coat of synthetic enamel paint over and including one coat of red oxide primer with sprayer and writing SM/MES No with white black enamel paint complete all as specified and direct ed at site.
WATER COOLERS
Supply, fixing & testing of blower motor for water cooler SP 230V 50 Hz AC 1/12 HP 930 RPM with fan of size 12.5" dia complete etc Make : GE Motor/AUE complete all as specified and directed
All as per item No-50 but 1/20 HP 1350 RPM with fan of 13" dia complete all as specified and directed.
All as per item No-50 but 1/35 HP, 1350 RPM with fan of 10" dia complete all as specified and directed
All as per item -50 above but 1/83 HP 1350 RPM and fan of 9" dia complete all as specified and directed.
Supply & fixing in replacement starting capacitor 40 to 60 MFD, 275 volts Make- Sharda/Empire/Bhel etc complete all as specified and directed.
All as per item No-54 above but of 60 to 80 MFD complete all as specified and directed.
Supply & fixing in repairs running capacitor 10 MFD 440 volts AC Make: EPCOS/ Capro /Asian etc complete all as specified and directed.
All as per item No 56 but of 15MFD complete all as specified and directed.
All as per item No 56 but of 25/30 MFD complete all as specified and directed.
Supply & fixing in replacement thermostat for water cooler up to 150 ltr capacity. Make : Ranutrol/Danfoss/Indfos etc complete all as specified and directed.
Supply & fixing in replacement push cock heavy duty brass Chromium plated 15mm bore (to match with existing defective push cock) Make King or Equivalent ISI marked as approved by GE. complete all as specified and directed.
Supply and fixing of float valve 15mm bore of PVC rigid type with polythene ball complete all as directed Make : Prayag or Equivalent as approved by GE. complete all as specified and directed.
M&L Scrapping down the existing paint of water cooler of any make & capacity cleaning and preparing the surface with necessary putty work and painting the complete body of Water cooler with foundation frame of compressor, condenser etc with one coat of synthetic enamel paint over and including a coat of red oxide primer with spray painting and writing SM/MES No with white/black paint all as directed.
Supply and fixing starting Relay current type suitable for compressor model= AE 4440M, KCE 443 HAA, CAJ, 34, CAJ 2612M, AE451E, KCE 461 HAE , 513HAE complete, Make-Kirloskar/Tecumseh/ Usha / Arvind
Supply and fixing in repairs of over load protector for compressor of water cooler complete all as specified and directed.
Supply and fixing of copper filter pencil type to any make and capacity of water cooler etc complete Make : Vaishali Metal complete all as specified and directed.
Supply and fixing in replacement of capillary tubing having 0.050/0.055 bore complete Make : Vaishali Metal complete all as specified and directed.
Supply and fixing of stop cock 15mm brass heavy duty having minimum wet 360 gm Make: Leader, GEM, Jaquar complete all as specified and directed.
Supply & fixing in replacement rubber hose pipe of 20mm size with clip for outlet tray of water cooler approx 1.5Mtr long complete all as specified and direct ed at site.
M&L Removing the burnt/defective sealed compressor unit of any make from water cooler cap 60 ltr/hr By cutting of suction and discharge lines and un-screwing the foundation nuts supply and fixing of new sealed compressor unit make : Kirloskar/Emmerson model : AE 444M or KCE 444 HAA/CAJ34 etc by tightening foundation nuts with new fittings and connecting suction and discharge line with gas welding work etc complete.
All as per item No 69 above but water cooler capacity 80 ltr/hr and S&F compressor Make : Kirloskar/Emmerson Model : CAJ 2612M/AE451E/KCE 461 etc complete.
All as per item No 69 but water cooler capacity 150-150 ltr/hr and S&F compressor Make : Kirloskar/Emmerson Model AHR-13/KCJ 513 complete all as specified and direct ed at site.
Supply & fixing in replacement cable PVC 3 core flexible heavy duty copper 2.5 Sqmm complete Make : Plaza/Finolex or ISI Mark complete all as specified and directed.
Repairing Testing the leakage in system by charging of Nitrogen Gas up to 300 PSI. Repairing of leakage spots/Joints with gas welding work, cleaning and flushing the complete water cooler with gas, making the system leak proof, vacuuming the complete system, supply and charging of Freon-22 Gas approx 1.6 Kg complete for water cooler 40/60/120 ltr capacity
M&L Dismantling of water cooler of any capacity and taking out complete internal assembly ie. Inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket etc.
M&L Replacement of water cooler inner tank made of stainless steel as per existing capacity (80 Ltrs) & size with necessary gaskets complete set with drilling work fixing with nut,bolts & washer etc complete all as specified and direct ed at site.
All as per item No 75 above but 150 Ltrs. complete all as specified and direct ed at site.
M&L Replacement of glass wool in 40/60/80/120 ltrs capacity water coolers by taking out inner outer tank and reassembling in same position including testing complete all as specified and direct ed at site.
Repairing of bottom base and legs of water cooler by suitable welding work complete all as specified and directed.
DEEP FREEZER
M&L Testing the leakage in system by charging Nitrogen Gas up to 300 PSI. Repairing the leakage spots/Joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length. Making the system leakproof vacuuming the system and charging of Gas 134a approx 1.0 Kg and testing complete
Supply & fixing in replacement of Relay current type and over load protector complete set suitable for compressor Model KCE 336 & KCE 345/2415 complete all as specified and direct ed at site.
Supply & fixing in replacement of thermostat Auto defrost type complete for Deep freezer (Refrigeration of)any make & capacity Make : Ranutrol/Indfos etc complete all as specified and direct ed at site.
M&L Removing burnt/defective sealed compressor unit from deep freezer of any make by cutting of suction and discharge lines and un-screwing of foundation nuts. Supply and replacing of new sealed compressor unit Make : Kirloskar Model :KCS 410 LAA/KCS 412 LAG/Tecumseh 2415 incl necessary gas welding making the system leak proof, testing and tightening the foundation nuts with new grounts and connecting suction and discharge line with gas welding work etc complete.
All as per item No 83 but compressor Make-Tecumseh Model TSK-1350 complete all as specified and direct ed at site.
Supply and fixing relay current type and over load protector complete set suitable for compressor model No KCS 410 LAA or KCS 412 LAG fixed in repairs complete all as specified and direct ed at site.
Supply & fixing in replacement of drier filter complete set suitable for deep freezer 215 / 386 ltrs complete all as specified and direct ed at site.
Supply, fixing & testing of blower motor for Deep frizer SP 230V 20 watts complete with fan complete all as specified and directed
REFRIGERATOR
S&F Relay current type and overload protector complete suitable for compressor model KCE336, KCE345 fixed in repairs complete all as specified and direct ed at site.MAKE : Ranutrol/ Voltas /LG
S&F Thermostat auto defrost type, fixed in repairs for refrigerators any make & capacity 165/310 Ltr Rerfrigerator complete all as specified and direct ed at site. MAKE : Danfos/Ind foss/Ranutrol
Vegitable tray as per sample and suitable for refrigerator Make Godrej, Voltas or whirlpool , LG of capacity 300 Ltr
S&F Evaporator suitable for Voltas/Godrej refrigerators capacity fixed in repairs 286/300 ltr complete all as specified and direct ed at site .
M&L for removing burnt/defective sealed compressor unit of any make from any type/Capacity (165/286/300/310 Ltr) of refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit Make Tecumesh, Godrej, Voltas or whirlpool , LG, including necessary gas welding, making the system leak proof, including Repair to leakage in system by charging of nitrogen gas upto 300PSI, in the refrigeration system, testing and tracing the leakage in system, arresting the leakage with gas welding etc and making the complete system leak proof, vaccumising the system and testing, the system for smooth functioning complete and charging of refrigerent gas 134a complete all as specified and directed at site.
Supply and charging of gas Freon- 134-A complete all as specified and directed. Note:- Gas will be accepted in sealed and tested cylinder having capacity 10 Kg each.
M&L for checking of AC supply electrical/electronics circuitary of water purification system, finding fault and rectification the same with repair of step down transformer 230 volt to 12/24 volts, and replacement of resistance , small pieces of wires etc complete all as directed .
M&L for repairing / Maint of water purifier Make- Beetek installed in verious building of Infantry school including replacement of candle and cartrige complete all as directed.
M&L Checking the unserviceable plant (such as water cooler, refrigerator, Deep frizer etc) of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete Note:- Petty stores such as insulation tape, screws, small pieces of wires, etc shall be provided by the Contractor. Cost of the same is deemed to be included in the quoted unit rate.
VOLTAGE STABLIZER
103. Taking out of deffective / burnt stablizer from verious locations under GE (Maint) Infantry school Mhow of verious capacity from 1 KVA to 5 KVA single phase and repair /replacement of the following defective parts as under and testing complete all as specified and directed. by Engr-in-charge.
(a) Terminal strip
(b) Push button switch
© Rocker switch
(d) Circuit card from 3 to 5 KVA
(e) Circuit card from 1 to 2 KVA
(f) Relay 24 Volts 250 Ohms for 3 to 5 KVA
(g) Volt meter 0-300 volts size as per sample
(h) Indicator lamp (red/green)
Vinayak Trading House
S.S. Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .