Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC 19 C CUDDALORE MAIN ROAD PEDDANAICKENPALAYAM PO TK SALEM DIST PIN 636 109 | SALEM | SALEM | TAMIL NADU | 636109 | ₹8.0 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹8.0 L+₹295.44 (0.04%)Rejected-AOC | ₹8.0 L+₹295.44 (0.04%) | L2 | Rejected-AOC BEING L2 |
| 3 | L3₹8.3 L+₹31,368.80 (3.90%)Rejected-AOC NO 83 AMBEDKAR STREET MITTANAMALLI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | ₹8.3 L+₹31,368.80 (3.90%) | L3 | Rejected-AOC BEING L3 |
| 4 | L4₹8.4 L+₹39,803.60 (4.95%)Rejected-AOC NO 1 116 GANGAI AMMAN KOVIL STREET SORANJERY PATTABIRAM CHENNAI 600072 | CHENNAI | CHENNAI | TAMIL NADU | 600072 | ₹8.4 L+₹39,803.60 (4.95%) | L4 | Rejected-AOC BEING L4 |
| 5 | L5₹8.4 L+₹40,801.40 (5.08%)Rejected-AOC | ₹8.4 L+₹40,801.40 (5.08%) | L5 | Rejected-AOC BEING L5 |
| Sl No | Description | Qty | Unit | ANISHRAJAN ENTERPRISES L3 | Mariammal Constructions L4 | K Kumar Construction L2 | S.T.S.CONSTRUCTIONS AGENCIES L1 | SHRI BALAJI CONSTRUCTIONS L6 | KNS CONSTRUCTIONS L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down steel water tubing and connection including cleaning for refixing for 15mm bore pipe and removing from site or work complete | 105 | RM | 9 ₹945 Lowest | 50 ₹5,250 | 12 ₹1,260 | 65 ₹6,825 | 25 ₹2,625 | 30 ₹3,150 |
| 2.00 | Taking down or up old steel tubing 20mm dia bore galvanized including all connections all as specified and directed by Engineer-in-Charge. | 90 | RM | 12 ₹1,080 Lowest | 65 ₹5,850 | 12 ₹1,080 Lowest | 80 ₹7,200 | 25 ₹2,250 | 35 ₹3,150 |
| 3.00 | Taking down or up old steel tubing 25mm dia bore galvanized including all connections all as specified and directed by Engineer-in-Charge. | 57 | RM | 13 ₹741 Lowest | 80 ₹4,560 | 14 ₹798 | 95 ₹5,415 | 25 ₹1,425 | 40 ₹2,280 |
| 4.00 | Supply & fix Galvanized steel water tubing 15mm dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge. | 100 | RM | 172 ₹17,200 Lowest | 360 ₹36,000 | 192 ₹19,200 | 220 ₹22,000 | 180 ₹18,000 | 250 ₹25,000 |
| 5.00 | Supply & fix Galvanized steel water tubing 20mm dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge. | 80 | RM | 189 ₹15,120 Lowest | 410 ₹32,800 | 236 ₹18,880 | 250 ₹20,000 | 220 ₹17,600 | 275 ₹22,000 |
| 6.00 | Supply & fix Galvanized steel water tubing 25mm dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge. | 45 | RM | 210 ₹9,450 Lowest | 450 ₹20,250 | 340 ₹15,300 | 280 ₹12,600 | 250 ₹11,250 | 325 ₹14,625 |
| 7.00 | Refixing of old Galvanized steel water tubing 15mm dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge. | 5 | RM | 25 ₹125 Lowest | 120 ₹600 | 48 ₹240 | 45 ₹225 | 50 ₹250 | 60 ₹300 |
| 8.00 | Refixing of old Galvanized steel water tubing 20mm dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge. | 10 | RM | 25 ₹250 Lowest | 150 ₹1,500 | 54 ₹540 | 45 ₹450 | 80 ₹800 | 65 ₹650 |
| 9.00 | Refixing of old Galvanized steel water tubing 25mm dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge. | 12 | RM | 25 ₹300 Lowest | 160 ₹1,920 | 63 ₹756 | 45 ₹540 | 100 ₹1,200 | 75 ₹900 |
| 10.00 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning repairing and providing new outlet connection of required size complete for capacity n.exc 500 ltrs all as specified and directed. | 8 | Each | 425 ₹3,400 | 300 ₹2,400 Lowest | 340 ₹2,720 | 800 ₹6,400 | 500 ₹4,000 | 500 ₹4,000 |
Tender Value
₹10.0 L
EMD Value
₹20,000
Closing Date
23 Aug 2025, 6:00 pmClosed
AGE I R AND D AVADI
AGE I R AND D AVADI
REPAIR TO ROOF TREATMENT AND CONNECTED WORKS TO CERTAIN BLDGS IN RESIDENTIAL AREA AT CVRDE AVADI
2025_MES_722662_1
8693/E8
Open Tender
Civil Works
Item Rate
180 days
AVADI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE I R AND D AVADI
₹20,000
Yes
29 Sept 2025
26 Jul 2025
28 Aug 2025
26 Jul 2025
23 Aug 2025
9 Aug 2025
Amount
Taking down steel water tubing and connection including cleaning for refixing for 15mm bore pipe and removing from site or work complete
Taking down or up old steel tubing 20mm dia bore galvanized including all connections all as specified and directed by Engineer-in-Charge.
Taking down or up old steel tubing 25mm dia bore galvanized including all connections all as specified and directed by Engineer-in-Charge.
Supply & fix Galvanized steel water tubing 15mm dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge.
Supply & fix Galvanized steel water tubing 20mm dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge.
Supply & fix Galvanized steel water tubing 25mm dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge.
Refixing of old Galvanized steel water tubing 15mm dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge.
Refixing of old Galvanized steel water tubing 20mm dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge.
Refixing of old Galvanized steel water tubing 25mm dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning repairing and providing new outlet connection of required size complete for capacity n.exc 500 ltrs all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning repairing and providing new outlet connection of required size complete for capacity n.exc 1000 ltrs all as specified and directed.
Demolition of cement concrete in floors/roof surfaces including removal of old tar felt, plastering, concrete mugs, tiles etc up to the original RCC roof level all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate in roof as levelling course, kerbs or mud stops, rounded or chamfered on edges.
Supply only integral water proofing compound
Material & labour for water proofing treatment with water base polyurethane modified dispersion shall be carried out all as specified as under: - (a) Mechanical cleaning of surface to make it free from any bituminous residue / dirt. Oil and grease etc all as directed by GE / Engineer-in-Charge. (b) Cracks treatment by cutting open cracks and cleaning it from dirt loose materials etc and filling with polyurethane based sealant with and including application of PU based primer all as directed by GE / Engineer-in-Charge. (c) Applying water based polyurethane modified dispersion (single component cold applied, non toxic, VOC complaint) in 03 coats including 01 coat of primer of same material after dilution of water at 50% or specific primer matching same material as per manufacturer specification and as directed by GE / Engineer-in-Charge.
Properties of polyurethane based chemical shall be as follows: - (i) Highly elastic (ii) UV resistance (iii) Adhesion to concrete > 1N/Sqmm. (iv) Tensile strength - not less than 2.0N/Sq.mm for free film. (v) Elongation - not less than 300%. (vi) Solid content by weight - not less than 60%. (vii) Air / water permeability BSEN 12390 at 5 bar - 72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.0m. (viii) Accelerated weathering (ASTM 453): Pass 1000 hours. (ix) Reaction to fire - non inflammable.
Note: (i) To be applied by the manufacturer's authorized applicator only. Contractor has to provide manufacturer's test certificate for the above mentioned technical parameters and purchase Vrs. (ii) Removal of existing treatment to be paid separately. (iii) Roof top to be ensured to avoid water ponding. (iv) For accessible terrace and inaccessible terrace, 300mm height of vertical surface / parapet wall to be treated with same specification of slab. Make: Berger, Fosroc, or any other make approved by E-in-C's Branch for PU based water proofing treatment.
Demolition of brick work built in cement mortar complete all as specified and directed by Engineer-in-Charge.
M&L brick work using sub class 'B' bricks in CM 1:4 straight or curved on plan exc 6m means radius complete all as specified and directed .
Taking down cement plaster on brick or concrete surfaces hacking for key scrubbing down with water etc.
M&L for 15mm thick cement plaster in CM 1:4 on fair faces of brick work or concrete surfaces and finished even and smooth with out using extra cement but using water proofing compound @ 3% of cement weight all as specified and directed by Engineer-in-Charge. (Note: WPC shall be measured and paid separately)
M&L for preparation of newly plastered/unplastered surfaces of wall and applying two coats of weather coat paint on concrete/brick over a coat of primer complete all as specified.
Cutting down plants/trees of girth n.exc 15cm from roof tops/sides external walls of bldgs chajjas wall junctions incl taking out possible quantities of roots entered in wall/slab surfaces and making good the surfaces and cleaning the roof surface. shall be carried out using PCC 1:2:4 of any depth up to bottom of excavated part/portion and 15mm thick plaster in CM 1:4 area n.exc 0.15 Sqm each all as specified and directed.
M&L for 150mm thick Cement concrete type C-2, 1:3:6 (40mm graded aggregate) for PVC tank platform over the roof flat surface including necessary form work
Removing excavated/demolished material exc. 1.50 km but n exc.5km and depositing where directed
K Kumar Construction (BID ID -3403273)
ANISHRAJAN ENTERPRISES (BID ID -3394204)
Mariammal Constructions (BID ID -3395465)
KNS CONSTRUCTIONS (BID ID -3403940)
SHRI BALAJI CONSTRUCTIONS (BID ID -3404253)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .