Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.8 L+₹2.1 L (10.2%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L2 | Rejected-AOC L2 |
Tender Value
₹21.5 L
EMD Value
₹43,000
Closing Date
6 Aug 2022, 6:00 pmClosed
GE Bharatpur
Kanjoli line Bharatpur
Spl rep to replacement of OH line to UG Cable near MD Accn and MI room area at RMS Dholpur
2022_MES_536450_1
8128/E8
Open Tender
Civil Works
Item Rate
180 days
GE Bharatpur
as per tender document
6 documents required · 6 mandatory
₹500
GE Bharatpur
₹43,000
Yes
31 Aug 2022
7 Jul 2022
15 Aug 2022
7 Jul 2022
6 Aug 2022
22 Jul 2022
9 Jul 2022 - 18 Jul 2022
Amount
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying LT UG cable, and getting out in hard disintegrated rock complete all as specified and directed.
Removal of excavated soil at a distance not exc 50 m and deposited Where directed complete all as specified and directed.
Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Supply and laying of Sub class B Bricks in trenches over the LT/HT cables for the protection of cables, laid across the length complete all as specified and directed by Engineer-in-Charge.
M &L for river sand for bedding and sand cushioning of all HT/LT UG cable complete all as specified and directed by Engr-in-Charge
M&L for PCC (1:3:6) type C1 using 20mm graded stone aggregate in foundation and mass concrete including necessary form work complete all as specified and directed.
M&L for dismantling of old UNSV ACSR conductors of 4 run from poles any size and type complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 1100Volts grade of size 70 Sqmm 3.5core complete all as specified and directed by Engineer in Charge.
-ditto- all as per Ser No 08 but size 50 sqmm x 3.5 core
-ditto- all as per Ser No 08 but size 35 sqmmx 3.5 core
-ditto- all as per Ser No 08 but size 25 sqmmx 4 core
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 1100Volts grade of size 16 Sqmm 4 core complete all as specified and directed by Engineer in Charge.
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 1100Volts grade of size 10 Sqmm 2 corecomplete all as specified and directed by Engineer in Charge.
Dismantling of corroded out and broken Cross arms, bracings , nuts bolts, channels and clamping devices etc any size and capacity
Dismantling of old UNSV insulators any size and type all as specified and as directed.
Supply and lay GI tubing light grade for road crossings, poles etc. where ever directed of size 50mm borecomplete all as specified and directed by Engineer in Charge.
M&L for cutting of bituminous road of any type and thickness for the width of cut 15cm and depth of cut 30cm for inserting GI pipe 50mm, by using grinder or cutter & refilling the hard core materials and well finishing packed with 100mm thick layer of 1:3:6 type C-1 PCC complete all as specified and directed by Engineer-in-Charge
Supply and install commissioning and testing factory made and tested (includng CPRI certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated Aluminium bus bars 600 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2.0 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick angle iron for stand. The necessory electric connection of MCCB above including 63 amp should be carried out copper busbar and below 63 amp should be carried out from 16 sqmm single core copper cable. The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm for metering system. Front & Back opening type with cable alley for cable entry with double door shutter including locking arrangement as per anufacturers with 2 Keys. The scope of work includes provn of the following:- Incoming (a) MCCB 4 pole breaking capacity 35 KA thermal magnetic adjustable type- 400 Amps - 01 Nos. (b) Aluminium Bus bar 600 Amps - 04 nos Outgoing (a) MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type 250 AMP -01 nos (b) MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type 100 AMP -01 nos (c) MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type 63 AMP -02 nos
Supply and install commissioning and testing factory made and tested (includng CPRI certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated Aluminium bus bars 300 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2.0 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick & angle iron for stand. The necessory electric connection of MCCB above including 63 amp should be carried out copper busbar and below 63 amp should be carried out from 16 sqmm single core copper cable. The complete feeder pillar box should be powder coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm for metering system. Front & Back opening type with cable alley for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. The scope of work includes for provn of the followings : Incoming (a) MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type- 250 Amps - 01 Nos. (b) Aluminium Bus bar 300 Amps - 04 nos Outgoing (a) MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type 160 AMP -03 nos
Supply and install commissioning and testing factory made and tested (includng CPRI certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated aluminium bus bars 300 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2.0 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick angle iron for stand. The necessory electric connection of MCCB above and including 63 amp should be carried out copper busbar and below 63 amp should be carried out from 16 sqmm single core copper cable. The complete feeder pillar box should be powder coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm for metering system. Front & Back opening type with cable alley for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. The scope of work includes followings : Incoming (a) MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type- 200 Amps - 01 Nos. (b) aluminium Bus bar 300 Amps - 04 nos Outgoing (a) MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type 100 AMP -01 nos (b) MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type 63 AMP -01 nos (c) MCCB 4 pole breaking capacity 16 KA thermal magnetic adjustable type 40 AMP -01 nos
Supply and install commissioning and testing factory made and tested (includng CPRI certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phase, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated aluminium bus bars 300 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 2.0 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 40 x 40 x 6 mm thick angle iron for stand. The necessory electric connection of MCCB above including 63 amp should be carried out copper busbar and below 63 amp should be carried out from 16 sqmm single core copper cable. The complete feeder pillar box should be power coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 4 Sqmm for metering system. Front & Back opening type with cable alley for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys. The scope of work includes provn of the followings Incoming (a) MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type- 100 Amps - 01 Nos. (b) aluminium Bus bar 300 Amps - 04 nos Outgoing (a) MCCB 4 pole breaking capacity 25 KA thermal magnetic adjustable type 63 AMP -02 nos (b) MCCB 4 pole breaking capacity 16 KA thermal magnetic adjustable type 40 AMP -02 nos
Supply and install bus bar chamber, factory made, cubicle type, out door type double door, locking arrangements, made up of MS sheet of min 3mm thickness, size 60X60X40 cm CRCA FRP proof, zinc coated, 7 tank wahsed, including spraying light smoke grey weather proof mettalic paint with RYB indicators, 100Amp capacity Aluminium bus bar, 01x 4 pole MCCB 63 Amp 16 KA , suitable cable jointing arrangements etc mounting channels made up of MS angle, all as specified and as directed by Engineer-in-Charge. Drawing and make shall be approved by GE before installtion at site.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters figures and conventional skull and bones in singnal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT, 20x15cm size.
20. M & L earthing complete with GI plate electrode 60cm x 60cm x 6 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the GI earth strip 32x 6 mm by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on complete all as specified and directed. Note :- The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
17. S&F Junction box made out of HDPE / Poly carbonate PVC plastic suitable for outdoor installation of size min 300 mm x200mmx150mm with hinged door and locking arrangement including aluminum bus bar of size 25x3mm three phase & Neutral fixed on insulator, incl one No MCB SP 6 amps and 08 RM 1.5 Sqmm 3 core copper cable from light to pole box & complete all as specified and as directed. Make SINTEX / HENSEL/ UNIVERSAL
S&F in replacement timer switch 24Hrs Analog dial type suitable for street lights and high mast lights with complete assembly 63Amps capacity, comprising one contactor of 40Amp and one MCB TPN of 40Amp, outdoor type with enclosure and clamping arrangements including taking out the old UNSV one any size and type complete all as specified and directed by Engineer-in-Charge. Make- Havells or equivalent in L&T/Schneider
Supply and fixing street light mounting bracket made out of GI pipe 40 mm dia med grade not less than with 1.8 m long in any shape with 2 nos of pole fitting clamps made out of MS flat of size 40 x 6 mm and nuts and bolts complete all as specified and directed..
PD GUPTA AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .