| 1 | L1₹29.1 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹34.0 L+₹4.8 L (16.3%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹35.4 L+₹6.2 L (21.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹35.5 L+₹6.3 L (21.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹35.8 L+₹6.6 L (22.6%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | M/S MAYANK ASSOCIATE L1 | M/S ROHIT CONSTRUCTION L3 | UNIVERSAL INFRAPROJECT PVT LTD L5 | M/s KAKSI ENTERPRISES L2 | ANKIT BUILDERS L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed. | 70 | CUM | 250 ₹17,500 | 150 ₹10,500 Lowest | 200 ₹14,000 | 170 ₹11,900 | 200 ₹14,000 |
| 2.00 | Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed | 54 | CUM | 200 ₹10,800 | 110 ₹5,940 | 70 ₹3,780 | 50 ₹2,700 Lowest | 70 ₹3,780 |
| 3.00 | M&L for sand filling under floor or in foundations including gently punned as in cushioning to cable complete all as specified and directed.
Note:- Punned thickness of sand shall be measured and paid. | 9 | CUM | 1,300 ₹11,700 | 420 ₹3,780 Lowest | 500 ₹4,500 | 800 ₹7,200 | 500 ₹4,500 |
| 4.00 | Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. | 17 | CUM | 260 ₹4,420 | 110 ₹1,870 | 70 ₹1,190 Lowest | 100 ₹1,700 | 150 ₹2,550 |
| 5.00 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed. | 2 | CUM | 4,800 ₹9,600 | 3,200 ₹6,400 | 6,000 ₹12,000 | 3,000 ₹6,000 Lowest | 6,000 ₹12,000 |
| 6.00 | M&L for drilling suitable holes in reinforced cement concrete with power driven drill machine to a minimum depth of 10D (D-dia of bar in mm) in RCC beams, lintels, columns and slabs to introduce new steel bars including cleaning the holes by air blowers prior to fixing the new steel bars in position using Lokfix E77, a two-component epoxy anchoring material, supplied in 3:1 ratio having compressive strength (EN196) not less than 122 N/sqmm, Flexural Strength (EN196) not less than 66 N/sqmm, E Modulus (EN ISO 527-2) 6300 N/sqmm or of equivalent make but excluding the cost of reinforcement, complete all as per direction of Engineer-in- Charge for 10mm shear connectors.
Note :
1. Anchoring chemical shall comply with ETA 21/0354, ETA 21/0518 for anchoring bars for 10mm dia complete all as specified and directed.
2. Reinforcement shall be measured and paid separately. | 32 | EACH | 850 ₹27,200 | 50 ₹1,600 Lowest | 150 ₹4,800 | 690 ₹22,080 | 800 ₹25,600 |
| 7.00 | M&L for applying bond coat of epoxy bonding agent & cement in 1:1 ratio for bonding old and new concrete on damaged surfaces after applying anticorrosive paint over cleaned rusted steel surface including demolition old RCC surfaces (chajjas, fins, beams , borders etc and applying 30mm thick polymer modified mortar in CM 1:3 including mixing of polymer latex additives for repair of Chajjas fins, border etc complete all as specified and directed.
Note :-
(i) Cleaning of rusted part of steel and applying anticorrosive paint over it.
(ii) Qty of ploymer to be used 15% by weight of the cement or as per manufacturer instruction.
(iii) Use of electrical mixer to get the homogeneous dough on bond coat surfaces.
(iv) To achieve required thickness repeat this step after 24 hrs as required.
(v) Keep the surfaces moist using water fog for 5 to 7 days etc complete all as specified and as directed.
(vi) Rate shall be inclusive of all necessary scaffolding for building of height upto two storey.
Make :-
(i) The epoxy bonding agent shall be Krishna / Dr Fixit / MC Bauchemie / M/s Cemistik / Sika or equivalent as approved by GE.
(ii) Polymer latex addictive shall be of Sika / Fosroc / Dr Fixit or equivalent as approved by GE. | 250 | SQM | 270 ₹67,500 Lowest | 420 ₹1,05,000 | 400 ₹1,00,000 | 790 ₹1,97,500 | 650 ₹1,62,500 |
| 8.00 | M&L brick work using old size sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. | 1.5 | CUM | 5,200 ₹7,800 | 4,200 ₹6,300 Lowest | 5,500 ₹8,250 | 4,800 ₹7,200 | 6,000 ₹9,000 |
| 9.00 | M&L for brick protection cover to the under ground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm all as specified and directed. | 0.9 | PER 1000 NOS | 7,000 ₹6,300 | 3,000 ₹2,700 | 5,000 ₹4,500 | 800 ₹720 Lowest | 4,000 ₹3,600 |
| 10.00 | M&L for cutting holes by core cutting machine over stone masonry wall having thickness n.exc 450mm and having 50 to 75mm dia including inserting PVC pipe as required and making good with existing surface with CM 1:4 and cleaning of debris outside MD land complete all as specified and as directed. | 22 | EACH JOB | 500 ₹11,000 | 120 ₹2,640 Lowest | 1,000 ₹22,000 | 270 ₹5,940 | 600 ₹13,200 |
Tender Value
₹38.8 L
EMD Value
₹77,600
Closing Date
20 Oct 2025, 6:00 pmClosed
GE (S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
SPECIAL REPAIR TO ROOF TREATMENT AT P-603, P-621, P-622, P-623, P-624, P-625, P-626, P-152, P-153, P-333, P-334 UNDER GE(S) JAIPUR AT MIL STN JAIPUR
2025_MES_731918_1
GE(S)/J-39P/2025-26 8997/E8
Open Tender
Civil Works
Item Rate
180 days
GE (S) Jaipur
Class D and category a(i)
8 documents required · 8 mandatory
₹500
GE(S) Jaipur
₹77,600
Yes
18 Dec 2025
20 Sept 2025
27 Oct 2025
20 Sept 2025
20 Oct 2025
13 Oct 2025
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed.
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed
M&L for sand filling under floor or in foundations including gently punned as in cushioning to cable complete all as specified and directed. Note:- Punned thickness of sand shall be measured and paid.
Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed.
M&L for drilling suitable holes in reinforced cement concrete with power driven drill machine to a minimum depth of 10D (D-dia of bar in mm) in RCC beams, lintels, columns and slabs to introduce new steel bars including cleaning the holes by air blowers prior to fixing the new steel bars in position using Lokfix E77, a two-component epoxy anchoring material, supplied in 3:1 ratio having compressive strength (EN196) not less than 122 N/sqmm, Flexural Strength (EN196) not less than 66 N/sqmm, E Modulus (EN ISO 527-2) 6300 N/sqmm or of equivalent make but excluding the cost of reinforcement, complete all as per direction of Engineer-in- Charge for 10mm shear connectors. Note : 1. Anchoring chemical shall comply with ETA 21/0354, ETA 21/0518 for anchoring bars for 10mm dia complete all as specified and directed. 2. Reinforcement shall be measured and paid separately.
M&L for applying bond coat of epoxy bonding agent & cement in 1:1 ratio for bonding old and new concrete on damaged surfaces after applying anticorrosive paint over cleaned rusted steel surface including demolition old RCC surfaces (chajjas, fins, beams , borders etc and applying 30mm thick polymer modified mortar in CM 1:3 including mixing of polymer latex additives for repair of Chajjas fins, border etc complete all as specified and directed. Note :- (i) Cleaning of rusted part of steel and applying anticorrosive paint over it. (ii) Qty of ploymer to be used 15% by weight of the cement or as per manufacturer instruction. (iii) Use of electrical mixer to get the homogeneous dough on bond coat surfaces. (iv) To achieve required thickness repeat this step after 24 hrs as required. (v) Keep the surfaces moist using water fog for 5 to 7 days etc complete all as specified and as directed. (vi) Rate shall be inclusive of all necessary scaffolding for building of height upto two storey. Make :- (i) The epoxy bonding agent shall be Krishna / Dr Fixit / MC Bauchemie / M/s Cemistik / Sika or equivalent as approved by GE. (ii) Polymer latex addictive shall be of Sika / Fosroc / Dr Fixit or equivalent as approved by GE.
M&L brick work using old size sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for brick protection cover to the under ground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm all as specified and directed.
M&L for cutting holes by core cutting machine over stone masonry wall having thickness n.exc 450mm and having 50 to 75mm dia including inserting PVC pipe as required and making good with existing surface with CM 1:4 and cleaning of debris outside MD land complete all as specified and as directed.
M&L for mild steel TMT bar 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bar 6 to 8 mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for applying fibre reinforced, single component, elastomeric liquid applied water proofing coating in white colour, anti-fungal, anti-algae, resistance to water and ageing, excellent UV resistant having Solar Reflective Index more than 105, with PU hybrid polymers and reinforcing acrylic fibers, elongation greater than 300% and applied in three layer complete all as follow :- (a) Preparation of surface by cleaning and removing loose particles then apply first coat of liquid water proofing after diluting as per manufacture instruction as a primer and allow the surface to dry for minimum 10 to12 hours complete all as specified and directed. (b) Apply second coat of liquid water proofing without dilution on the primed surface and allow time to dry the surface for minimum 10 to12 hours complete all as specified and directed. (c) Apply third coatof liquid water proofing without dilution over the second coat and allow minimum 48 hour complete all as specified and directed. Note : (i) Work shall be carried out by authorised applicator of manufacturer only and contractor will submit MoU with authorised applicator of manufacturer before execution of work. (ii) Material incorported in the work shall be calculated as per site requirement and full quantity of material shall be brought at site before execution of work. (iii) Necessary gurantee for 05 years shall be submitted by the contractor. Make :- Berger-HS Roof Kool & Seal, STP-Shali Urethane (R) BTD Plus, Asian - Smart care Damp Proof Ultra or equivalent make as approved by GE.
M&L for surface preparation by removal of all loose particle to ensure clean , smooth and dry surface and laying PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate 25 mm thick as roof padding to cover negative slope into prop and including WPC as per manufacturer instructions, surface finished even and fair without using extra cement complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 15 mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:3 as in ceiling surface and finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:4 on fair faces of brick or concrete surface of wall and finished even and smooth with out using extra cement complete all as specified and directed.
M&L for preparation of new surface of chhaja, ceiling of any description and applying two coats of acrylic emulsion exterior grade weather proof paint over a coat of primer including scaffolding upto three storey building complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls and applying one coat of oil bound distemper complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls by complete removal of existing treatment and applying two coat of acrylic emulsion exterior graded weather proof paint over a coat of primer including scffolding upto three stroey building complete all as specified and directed. Make for Acrylic Emulsion Paint : Apex Ultima of Asian Paint / WeatherShield Max of Dulux / WeatherCoat Anti Dust of Berger or equivalent make as approved by GE. Note :- Acrylic Emulsion Paint shall be carried out as specified in clause 15.17 of SSR Part-I including all necessary arrangement such as scaffolding / working plateform for execution of work upto four storey building etc.
M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior acrylic emulsion paint over a coat of primer including scaffolding upto three storey building complete all as specified and as directed.
M&L for preparation of new surface of walls of any description with a coat of 2mm thick wall putty complete all as specified and directed.
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 15 mm bore of pipe complete all as specified and directed.
S&F GI tubes medium grade with all fittings fixed to walls and ceilings or laid in floors of 20 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed.
Dismantling water tanks of any description, capacity exc 500 and not exc 1000 litres and removing from site complete all as specified and directed.
S & F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 1000 litre capacity hoisted and fixed in position complete all as specified and directed
S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe of 20 mm bore dia of pipe complete all as specified and directed.
S&F in repair ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule of 15 mm bore of pipe complete all as specified and directed.
M&L in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of 110 mm bore of pipe etc complete all as specified and directed.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core complete all as specified and directed. Note-Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core complete all as specified and directed. Note:- Excavation,earth work,sand,brick and protection pipe shall be measured and paid seperately.
S&F sheet metal enclosure factory fabricated for MCB distribution board SPN double door type concealed in wall 240 Volt 12 way IP-42 protection with 200 amp rated bus bar complete all as specified and directed.
S&F in repair sheet metal enclosure factory fabricated for MCB distribution board TPN double door type concealed in wall 415 volt 4 way IP-42 protection with 200 amp rated bus bar complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:3:6) type B-1 using 20mm graded stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1 using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm bore GI Pipe medium grade for watering complete all as shown in electrical plate No 3 of SSR Part-I(2009) and connected to earth test point including testing complete all as specified and directed. Note :- 1. PCC Chammer shall be constructed atleast 2.5 metre away form the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner. 2. GI wire and protection pipe upto 7.5 meter from the earth plate electrode is deemed to be included in quoted rate. 3. Excavation for earthing to be done manually and Earth resistance below 3 Ohm should be obtained after measurement for every pit.
M&L for sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated unsheathed FRLS copper cable 1100 V grade with multistranded copper conductor ISI marked drawn through and including PVC rigid conduit / casing capping not less than 20mm and conduit accessories fixed on surface of wall / celing etc including provision of 1 Run of 6 Sqmm PVC insulated unsheathed FRLS cable with multistranded copper conductor as earth continuity complete all as specified and directed. Note : 02 Run of 06 Sqmm copper wire and 01 Run of 06 Sqmm copper earth wire along with PVC conduct shall be measured as one unit.
S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single Pole and 06 to 32 Amp current carrying capacity complete with connection testing and commissioning all as specified and directed.
S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN and 32 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed.
S&F 415V 10KA 'C' curve miniature circuit breaker (MCB) of triple pole neutral (TPN) and 63 Amp current carrying capacity in the DB complete with connection testing and commissioning all as specified and directed.
S&F in repair intergral garden light decorative LED bollard light 10 watt, bollard type, pressure dia cast housing with PC diffuser, efficient high output LED with IP 65 protection shall be fixed with bolts on PCC for fixing pipe in ground and complete with electric connection all as specified and directed. Make : Crompton cat No LBLTW-10-CDL or equivalent in Bajaj / Havells / Halonix as approved by GE.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
Demolition of reinforced cement concrete (RCC) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) and removal of rubbish from site complete all as specified and directed.
M/s KAKSI ENTERPRISES (BID ID -3460049)
M/S ROHIT CONSTRUCTION (BID ID -3455669)
ANKIT BUILDERS (BID ID -3452617)
UNIVERSAL INFRAPROJECT PVT LTD (BID ID -3458901)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
8997Tender.pdf
Tender Documents • 0.99 MB
BOQ_819454.xls
BOQ • 0.30 MB
8997CORRIGENDUM.pdf
PDF • 0.69 MB
CorrigendumNo8997.pdf
PDF • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .