Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.1 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L2₹48.1 L+₹2.1 L (4.46%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹50.5 L+₹4.4 L (9.60%)Rejected-Finance PROTHRAPUR SRI VIJAYA PURAM SOUTH ANDAMAN 744105 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹56.4 L+₹10.3 L (22.4%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹58.0 L+₹11.9 L (25.8%)Rejected-Finance 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Tropical Refrigeration L5 | SKY GROUP L4 | SWASTHIK ENGINEERING WORKS L2 | RISING ENGINEERING L3 | ANITA VARMA ENTERPRISES L1 | DELTA ELECTRICALS L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for Servicing / cleaning / Decarbonizing of LT panel boards of any size/type not exceeding 2.5 cum volume of panel, clearing vegetation up to 1.5 mtr around the panel, spraying anti vegetation growth chemical, inspecting all cable terminations, lugs, insulation, busbars,Lt switchgears, meters etc, cleaning the busbars/panel with CRC solution for removing carbon contents, replacing pitted lugs with proper crimping pressure,insulating the peeled off insulation with superior quality high grade rubber insulation tape with proper colour code, replacing pitted/damaged busbar insulators all as per existing, marking radium stickering for all outgoing/incoming feeders with location, radium stickering of danger notice board on panel as per standards, replacing pitted control wiring of metering, replacing defective CTs/ meters /glands /indicator lamps, replacement of rusted doors with hinges/locking arrangements, tightening the cable end terminals with bus bar / connector links / MCCB / MCB end terminals with proper torque for avoiding loose connections, checking for any abnormal heating in the cables / MCCBs including applying a coat of red oxide primer after preparation of rusted surfaces only and applying two coats of enamel paint of approved colour by Enginner in Charge on entire surfaces outer side and inner side after preparation of surfaces , including making good broken PCC pedestals/ foundation, applying white wash etc complete all as specified and as directed. | 26 | Each Job | 8,900 ₹2,31,400 Lowest | 9,700 ₹2,52,200 | 9,250 ₹2,40,500 | 12,420 ₹3,22,920 | 9,100 ₹2,36,600 | 12,300 ₹3,19,800 |
| 1.01Note:- (i) cable lugs, reduced terminals (bottle lugs), in line connectors, glands, fabrication of doors, hinges/locks/tower bolts, meters, CTs, indicator lamps, insulators and insulation tape shall be measured and paid seperately as per site requirement under relevant items as supply only. (ii) The quoted rate deemed to be inclusive of M/L for removing loop of all cables for defect rectifications of end terminations,painting, radium stickering, making good of broken PCC and any other misc materials required for operational of panel. iii) Each panel board will be measured as one job only. (iv) Each servicing attended shall be measured as one job. (v) The contractor shall depute necessary man power on daily basis for rectifying the jobs including sundays and holidays in case of break downs the complaint to be attanded with in 02 hours after intimatation by concerned JE E/M or Engineer in Charge otherwise penalty of amount double the quoted rate will be recovered for non compliance. | |||||||||
| 2.00 | M&L for fabrication for LT Feeder Piller Box/ Panel Boards doors made out of 2.00 / 3.15 mm thick mild steel sheet by applying two coats of synthetic enamel paint over a coat of red oxide primer with hinges complete all as specified and directed. | 75 | Kg | 290 ₹21,750 | 190 ₹14,250 Lowest | 250 ₹18,750 | 310 ₹23,250 | 210 ₹15,750 | 310 ₹23,250 |
| 3.00 | Supply only aluminium tower bolts, 200mm long bright bolt including connected accessories for fixing on front/rear side of the doors for locking LT FP Boxes complete all as specified and as directed. | 3 | Each | 150 ₹450 | 135 ₹405 | 150 ₹450 | 125 ₹375 | 110 ₹330 | 100 ₹300 Lowest |
| 4.00 | Supply only door hinges of LT feeder pillar/Panel box complete with welding complete all as specified and as directed. | 10 | Each Job | 350 ₹3,500 | 480 ₹4,800 | 480 ₹4,800 | 1,798 ₹17,980 | 450 ₹4,500 | 160 ₹1,600 Lowest |
| 5.00Supply only aluminium cable lugs of following sizes of any type including reduced terminals/ bottle lugs/ connectors/ ferrules of following size as under:- Note: Each lug/ reduced terminals/ bottle lugs/ connectors/ ferrules will be measured as one unit. | |||||||||
| 5.01 | (i) 10 Sqmm | 15 | Each | 8 ₹120 Lowest | 10 ₹150 | 10 ₹150 | 11 ₹165 | 8 ₹120 Lowest | 10 ₹150 |
| 5.02 | (ii) 16 Sqmm | 20 | Each | 8 ₹160 Lowest | 15 ₹300 | 15 ₹300 | 12.5 ₹250 | 10 ₹200 | 12 ₹240 |
| 5.03 | (iii) 25 Sqmm | 25 | Each | 12 ₹300 Lowest | 18 ₹450 | 15 ₹375 | 13.8 ₹345 | 12 ₹300 Lowest | 14 ₹350 |
| 5.04 | (iv) 35 Sqmm | 25 | Each | 14 ₹350 Lowest | 20 ₹500 | 20 ₹500 | 21.2 ₹530 | 16 ₹400 | 16 ₹400 |
Tender Value
₹43.8 L
EMD Value
₹87,500
Closing Date
31 May 2025, 6:00 pmClosed
GE, Minniebay, Sri Vijaya Puram
GE, Minniebay, Junglighat (PO), Sri Vijaya Puram -744103
REPAIR/MAINT OF MAIN DISTRIBUTION PANEL, LT FEEDER PILLAR BOXES, LT PANEL BOARDS/CUBICLES, LT CABLES AND CONNECTED WORKS AT MD ACCN AREA OF MINNIEBAY AREA UNDER AGE E/M-I OF GE MINNIEBAY
2025_MES_706486_1
8558/E8
Open Tender
Civil Works
Item Rate
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
Yes
GE Minnie Bay
₹87,500
Yes
12 Aug 2025
3 May 2025
2 Jun 2025
3 May 2025
31 May 2025
17 May 2025
Amount
M & L for Servicing / cleaning / Decarbonizing of LT panel boards of any size/type not exceeding 2.5 cum volume of panel, clearing vegetation up to 1.5 mtr around the panel, spraying anti vegetation growth chemical, inspecting all cable terminations, lugs, insulation, busbars,Lt switchgears, meters etc, cleaning the busbars/panel with CRC solution for removing carbon contents, replacing pitted lugs with proper crimping pressure,insulating the peeled off insulation with superior quality high grade rubber insulation tape with proper colour code, replacing pitted/damaged busbar insulators all as per existing, marking radium stickering for all outgoing/incoming feeders with location, radium stickering of danger notice board on panel as per standards, replacing pitted control wiring of metering, replacing defective CTs/ meters /glands /indicator lamps, replacement of rusted doors with hinges/locking arrangements, tightening the cable end terminals with bus bar / connector links / MCCB / MCB end terminals with proper torque for avoiding loose connections, checking for any abnormal heating in the cables / MCCBs including applying a coat of red oxide primer after preparation of rusted surfaces only and applying two coats of enamel paint of approved colour by Enginner in Charge on entire surfaces outer side and inner side after preparation of surfaces , including making good broken PCC pedestals/ foundation, applying white wash etc complete all as specified and as directed.
Note:- (i) cable lugs, reduced terminals (bottle lugs), in line connectors, glands, fabrication of doors, hinges/locks/tower bolts, meters, CTs, indicator lamps, insulators and insulation tape shall be measured and paid seperately as per site requirement under relevant items as supply only. (ii) The quoted rate deemed to be inclusive of M/L for removing loop of all cables for defect rectifications of end terminations,painting, radium stickering, making good of broken PCC and any other misc materials required for operational of panel. iii) Each panel board will be measured as one job only. (iv) Each servicing attended shall be measured as one job. (v) The contractor shall depute necessary man power on daily basis for rectifying the jobs including sundays and holidays in case of break downs the complaint to be attanded with in 02 hours after intimatation by concerned JE E/M or Engineer in Charge otherwise penalty of amount double the quoted rate will be recovered for non compliance.
M&L for fabrication for LT Feeder Piller Box/ Panel Boards doors made out of 2.00 / 3.15 mm thick mild steel sheet by applying two coats of synthetic enamel paint over a coat of red oxide primer with hinges complete all as specified and directed.
Supply only aluminium tower bolts, 200mm long bright bolt including connected accessories for fixing on front/rear side of the doors for locking LT FP Boxes complete all as specified and as directed.
Supply only door hinges of LT feeder pillar/Panel box complete with welding complete all as specified and as directed.
Supply only aluminium cable lugs of following sizes of any type including reduced terminals/ bottle lugs/ connectors/ ferrules of following size as under:- Note: Each lug/ reduced terminals/ bottle lugs/ connectors/ ferrules will be measured as one unit.
(i) 10 Sqmm
(ii) 16 Sqmm
(iii) 25 Sqmm
(iv) 35 Sqmm
(v) 50 Sqmm
(vi) 70 Sqmm
(vii) 95 Sqmm
(viii) 120 Sqmm
(ix) 150 Sqmm
(x) 185Sqmm
(xi) 240Sqmm
(xii) 300Sqmm
(xiii) 400Sqmm
Supply only double compression brass cable glands as under:-
(i) 10 - 16 Sqmm
(ii) 25 - 35 Sqmm
(iii) 50 - 70 Sqmm
(iv) 95-120 Sqmm
(v) 150-185 Sqmm
Supply only CTs moulded type suitable for AC 230V (phase-earth ) 50 Hz supply busbar system of following ratios:
(i) 100/5 A class 1, 5 VA burden
(ii) 400/5 A class 1, 5 VA burden
(iii) 600/5 A class 1, 5 VA burden
(iv) 800/5 A class 1, 5 VA burden
(v) 1000/5 A class 1, 5 VA burden
Supply only LED Indicating lamp (R-Y-B) of complete all as specified and as directed.
Supply only self fusing silicone rubber tape with permanent adhesive free tape bonds, water & air tight seal flexible and confirmable, weather & corrision resistant, capable of insulation upto 9000 volts of approx size 2.50 cm width 3.0 Mtr long complete all as specified and as directed.
Supply only LT 1100 volts grade, self adhesive, PVC insulation tape of approx size 1.80 Cm width, 6.5 Mtr long complete all as specified and as directed.
Supply only porcelain/ SMC/ DMC insulators for supporting Bus bars of voltage grade 550 Volts complete all as specified and directed by Engineer-in-Charge.
Supply and fix in reapair of MCCB 400 Amps,TPN/ 4 pole, 415 volt, breaking capacity 36 KA, Ics = 100 % Icu, Thermal magnetic type complete all as specified and as directed.
Supply and fix in repair of MCCB 250Amps,TPN/ 4 pole, 415 volt, breaking capacity 36 KA, Ics = 100 % Icu, Thermal magnetic type complete all as specified and as directed.
Supply and fix in repair of MCCB 200Amps,TPN/ 4 pole, 415 volt, breaking capacity 25 KA, Ics = 100 % Icu, Thermal magnetic type complete all as specified and as directed.
Supply and fix in repair of MCCB 160 Amps, TPN/4 pole, 415 volt, breaking capacity 25 KA, Ics = 100 % Icu, Thermal magnetic type complete all as specified and as directed.
Supply and fix as in repair of MCCB 100 Amps, TPN/4 pole, 415 volt, breaking capacity 16 KA, Ics = 100 % Icu, Thermal magnetic type complete all as specified and as directed.
Supply and fix as in repair of MCCB 63 Amps, TPN/4 pole, 415 volt, breaking capacity 16 KA, Ics = 100 % Icu, Thermal magnetic type complete all as specified and as directed.
Taking down of unserviciable old UG Cable of following size and any type complete all as specified and directed .
(a) 3.5 Core 25 Sqmm to 3.5 Core 70 Sqmm
(b) 3.5 Core 95 Sqmm to 3.5 Core 120 Sqmm
(c) 3.5 Core 185 Sqmm to 3.5 Core 240 Sqmm
(d) 3.5 Core 300 Sqmm to 3.5 Core 400 Sqmm
Suppy and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cables, XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade complete all as specified and as directed for the following size :- Make: Polycab/ Gloster/ KEI/ Havells/ Fort Gloster Note: (i) The rates shall be inclusive of Cable lugs at both ends of cable and end termination kits will be measured and paid seperately. (ii) Excavation earth, return and re filling shall be measured and paid seperately. (iii) Joint kit if required shall be measured and paid seperately. (iv) Insulation Resistance value of cable shall be recorded before and after laying of cable.
(a) 3.5 Core 25 Sqmm
(b) 3.5 Core 35 Sqmm
(c) 3.5 Core 50 Sqmm
(d) 3.5 Core 70 Sqmm
(e) 3.5 Core 95 Sqmm
(f) 3.5 Core 120 Sqmm
(g) 3.5 Core 185 Sqmm
(h) 3.5 Core 240 Sqmm
(j) 3.5 Core 300 Sqmm
(k) 3.5 Core 400 Sqmm
Taking down and relaying of serviciable power cable of XLPE / PVC insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade along with DWC pipe laid in trenches / duct with saddling / on pole / through DWC pipe including all necessary fixing arrangement such as lugs and end termination etc of size 10 Sqmm to 35 Sq mm 3.5/4 Core complete all as specified and as directed.
Taking down and relaying of serviciable power cable of XLPE / PVC insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade along with DWC pipe laid in trenches / duct with shaddling / on pole including all necessary fixing arrangement such as lugs and end termination etc of size 50 Sqmm 3.5 core to 95 Sq mm 3.5 core complete all as specified and as directed.
Taking down and relaying of serviciable power cable of XLPE / PVC insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade along with DWC pipe laid in trenches / duct with shaddling / on pole including all necessary fixing arrangement such as lugs and end termination etc of size 120 Sqmm 3.5 core to 300 Sq mm 3.5 core complete all as specified and as directed. Note For Item Nos 21,22 & 23: (i) Excavation earth work, returning and refilling shall be measured and paid seperately under relevant items. (ii) M & L for DWC pipe aginst defective shall be measured and paid seperately under relevant item. (iii) Quoted rate inclusive of laying only serviceable portion of DWC pipe.
Supply & Laying as in repair of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm, polythylene confirming to IS 16205 part-24 including coupler & Bend with smoooth inernal and corrugated external surface for non pressue under ground cable complete all as specified and as directed. Make: Rex Poly Extrusion Ltd/ Tirupati Plastomatic Pvt Ltd/ Prince
Supply & Laying as in repair of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm, polythylene confirming to IS 16205 part-24 including coupler & Bend with smoooth inernal and corrugated external surface for non pressue under ground cable complete all as specified and as directed. Make: Rex Poly Extrusion Ltd/ Tirupati Plastomatic Pvt Ltd/ Prince
Supply & Laying as in repair of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 63 mm, polythylene confirming to IS 16205 part-24 including coupler & Bend with smoooth inernal and corrugated external surface for non pressue under ground cable complete all as specified and as directed. Make: Rex Poly Extrusion Ltd/ Tirupati Plastomatic Pvt Ltd/ Prince
Supply & Laying asin repair of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 77 mm, polythylene confirming to IS 16205 part-24 including coupler & Bend with smoooth inernal and corrugated external surface for non pressue under ground cable complete all as specified and as directed. Make: Rex Poly Extrusion Ltd/ Tirupati Plastomatic Pvt Ltd/ Prince
Supply & Laying as in repair of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 90 mm, polythylene confirming to IS 16205 part-24 including coupler & Bend with smoooth inernal and corrugated external surface for non pressue under ground cable complete all as specified and as directed. Make: Rex Poly Extrusion Ltd/ Tirupati Plastomatic Pvt Ltd/ Prince
Taking down of old GI Pipe of any size complete all as specified and as directed
Supply and laying GI pipe of light grade 40 mm dia all fitting fixture for fixing with wall / road crossing etc. complete all as specified and as directed.
Supply and laying GI pipe of light grade 50 mm dia all fitting fixture for fixing with wall / road crossing etc. complete all as specified and as directed.
Supply and laying GI pipe of light grade 63 mm dia all fitting fixture for fixing with wall / road crossing etc.complete all as specified and as directed
Supply and laying GI pipe of light grade 80 mm dia all fitting fixture for fixing with wall / road crossing etc.complete all as specified and as directed.
Supply and laying GI pipe of light grade 100 mm dia all fitting fixture for fixing with wall / road crossing etc.complete all as specified and as directed. Note for Item Nos 30.00 to 34.00: (i) Road cutting / excavation work shall be measured and paid separately.
Excavation in trenches any soft/loose soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, pipe, laying of cable etc not exc 10 Sqmtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and as directed
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and as directed
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point all as specified and as directed
M & L for Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C2 matching with the surroundings all as directed.
M/L for attending LT breakdown complaints/defects from transformer LT terminal box upto Bldg feeder pillar box/DBs with connected switchgears, cables etc complete for making the continuity of supply after rectifying the defects of the electrical network by carrying out with the following scope of work:- (i) cable faults : disconnecting the both ends of cable and check the insulation resistance value.Physical inspection / tracing the cable in cable duct/ trenches. Cutting/disconnecting damaged portion and re-checking for insulation value, and make the cable connection after rectification at both end terminations to restore the power supply. (ii) unserviceable control switch gears / MCCBs / MCB: remove the MCCB/MCB from the panel board and clean the carbonized / burnt surfaces with varnish / CRC solution to make good and fix the new MCCB of suitable rating and connect the cable to MCCB terminals with proper lugging and by applying proper torque to avoid loose connections. spreader links shall be provided if necessary as per site requirement. (iii) Terminals/lugs failure: check for any cable terminal damage / melting by over heating, loose contacts. the damaged portion of cable shall be removed and fixing the lugs and terminate the cable by applying proper torque to avoid loose connections and proper re-distribution of over loading of cable complete all as specifed and as directed. Note :- (i) cable joint kit, MCCB/MCB, lugs and cable fault detection by fault finding machine, any excavation earth work shall be measured and paid seperately under relevant items. spreader links /insulation tape shall be deemed to be included in the rate quoted. (iii) Each Breakdown complaint/defect attended shall be measured as one job through job card. (iv) The contractor shall depute necessary man power on daily basis for rectifying the jobs including sundays and holidays.
M&L for detecting LT UG cable faults located in any stretch/ depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, surge generator of capacity upto 1.1 KV, fault pin point surge wave reciever, cable indentification instrument , cable tracer for exact location of under ground cable routes. Note: The rate quoted deemed to be inclusive of transportation of equipment from any location and charges for service engineer for identifying the fault including their boarding & lodging complete.
Taking down of old U/s Joit Kit complete all as specified and as directed of following item No - 42.00, 43.00 as under:-
S & F for cable jointing kit for 1100Volt grade cable for indoor / outdoor end termination joint kit, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of followinng size complete all as specified and as directed as under:-
(a) 10 to 16 Sqmm 3.5 core
(b) 25 to 50 Sqmm 3.5 core
(c) 70 to 120 Sqmm 3.5 core
(d) 150 to 185 Sqmm 3.5 core
(e) 240 to 300 Sqmm 3.5 core
S & F for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of following size complete all as specified and as directed as under:-
(a) 10 to 16 Sqmm 3.5 core.
(b) 25 to 50 Sqmm 3.5 core.
(c) 70 to 120 Sqmm 3.5 core.
(d) 150 to 185 Sqmm 3.5 core.
(e) 240 to 300 Sqmm 3.5 core.
Taking down and rerouting / Discipline the serviciable Power Cable on wall /cable duct of size 16 to 50 Sqmm 3.5/4 core with saddling, aluminium patti with requard size of screw inside cable duct / on wall complete all as specified and as directed.
Taking down and rerouting / Discipline the serviciable Power Cable on wall /cable duct of size 70 to 185 Sqmm 3.5 core with saddling, aluminium patti with requard size of screw inside cable duct / on wall complete all as specified and as directed.
Taking Down of old U/S Junction box/ Busbar chamber of any type and any size complete all as specified and as directed.
Supply & fix sheet metal enclosed TPN Aluminium bus bar chamber with IP 54 protection having bus bar of rating 400 Amps with provision for cable alley & busbar for connecting minimum 04 cables with the bus bar design as per directions of Engineer-in-Charge complete all as specified and as directed
Material and labour for earthing with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 25 mm x 3 mm by means of GI Welding made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead, 20 mm dia GI pipe for watering and earth plate surrounded by packed layer of coal and common salt, 15cm thick all around bottom and top, watering pipe of 20 mm bore of light grade with funnel all as shown in electrical plate No 3 of SSR Part-I (2009) and connecting to earthing test point, main switch board, transformer neutral and testing on completion as directed including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with MS XPM Jalli, RCC 1:1.5:3 cover slab of size 300 x 300 x 100 mm with one handle made out of 8 mm dia round bar, wire mesh and testing complete all as specified and as directed including dismantling old defective earth pit. Note: (i) Cost of GI earth Strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation.returninng & filling. PCC chamber pit,RCC cover & test point. (iii) If the desired earth resistance is not achived during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable.
Material and labour for earthing with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 32 mm x 6 mm by means of GI Welding made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead, 20 mm dia GI pipe for watering and earth plate surrounded by packed layer of coal and common salt, 15cm thick all around bottom and top, watering pipe of 20 mm bore of light grade with funnel all as shown in electrical plate No 3 of SSR Part-I (2009) and connecting to earthing test point, main switch board, transformer neutral and testing on completion as directed including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with MS XPM Jalli, RCC 1:1.5:3 cover slab of size 400 x 400 x 100 mm with one handle made out of 8 mm dia round bar, wire mesh and testing complete all as specified and as directed including dismantling old defective earth pit. Note: (i) Cost of GI earth Strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation.returninng & filling. PCC chamber pit,RCC cover & test point. (iii) If the desired earth resistance is not achived during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable.
M&L for dismantling the cable connections of four pole/ three pole Air circuit breaker of capacity 800 to 1250 Amps ,415 V 50 HZ of L&T Make/C&S/GE/ABB make, strip opening the Air circuit breaker, inspecting the parts for serviceability/overhauling complete and carrying out the following repairs/maintenance :- a) Cleaning the insulation parts including bushings with CRC solution. b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. Replace the worn-out parts. d) Check arc chutes for damage . e) Clean and lubricate the operating mechanism with a light machine oil for pins and bearings and with a non-hardening grease for the wearing surfaces . Adjust breaker operating mechanism all as per manufacturer's instructional manual . f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required. g) Checking control device free for operation. j) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional Note : The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/ pins etc. Major spares like Shunt release & trip coil etc will be measured & paid separately under relevant schedule items
Supply only CTs suitable for air circuit breakers of rating 800 Amps to 1250 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager/ Schneider
Supply only auxiliary contact block suitable for air circuit breakers of rating 800 Amps to 1250 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager/ Schneider
Supply only arcing contacts (fixed/ moving) suitable for air circuit breakers of rating 800 Amps to 1250 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager/ Schneider
Supply only arc chutes (for 415 V) suitable for air circuit breakers of rating 800 Amps to 1250 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager/ Schneider
Supply only shunt release / under voltage release (110 /220 V DC or 240 V/415 V AC) suitable for air circuit breakers of rating 800 Amps to 1250 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager
Supply only cluster contact suitable for air circuit breakers of rating 800 Amps to 1250 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager
Supply only trip coil / closing coil suitable for air circuit breakers of rating 800 Amps to 1250 Amps as all per existing of Make: L&T/C&S/ GE/ABB/Havells/Hager
Supply and fixing as in repair service wire aluminium conductor Weather Proof 06 Sqmm two core complete all as specified and as directed
Supply and fixing as in repair service wire aluminium conductor Weather Proof 10 Sqmm two core complete all as specified and as directed
Supply and laying broken stone or Boulders filling of Gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 150mm thick, watered and rammed to a True Surface, complete all as specified and as directed
Material and labour for cross arms, bracing, supports, clamps and back plate fabricated from structural MS section for gate including nuts, bolts, washers, welding, bending, cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of taking down complete all as specified and as directed
Supply and fixing as in repair for GI earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32 mm x 6mm thick, Galvanised using porcelain clit/post insulators, complete all as specified and as directed
Supply and fixing as in repair for GI earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 mm x 3 mm thick, Galvanised using porcelain clit/post insulators, complete all as specified and as directed
Supply and fix as in repair MCB 40 - 100 Amp TPN/4 pole, 415 volt, breaking capacity 10 KA complete all as specified and as directed.
M & L for Cutting vegetation around the LT panel upto 1.5m distance and surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exc 60 mtr complete all as specified and directed
Supply, installing, testing and commissioning of LT panel board factory made outdoor type, double door, fabricated out of 3.15 mm thick CRCA sheet, floor mounting, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing switchgears/ACB/MCCB etc with locking arrangement, with back door openable (Screwed), including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands complete in all respect and including PCC work and provn of the following and including dismantling old LT panel:
Supply, installing, testing and commissioning of LT panel board factory made outdoor type, double door, fabricated out of 3.15 mm thick CRCA sheet, floor mounting, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing switchgears/ACB/MCCB etc with locking arrangement, with back door openable (Screwed), including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands complete in all respect and including PCC work and provn of the following and including dismantling old LT panel:
Supply and fixing of ACB 1250 Amps, 4P, MDO, 50 Hz, 415 V with minimum rupturing capacity 50 KA, Ics=100%Icu with advanced self powered micro processor based protection units having adjustable overload setting 40% to100%, Adjustable short circuit and earth fault protection complete all as specified and as directed. Make: L&T/ C&S/ Legrand/ Schneider
Supply, installing, testing and commissioning of LT panel board factory made outdoor type, double door, fabricated out of 3.15 mm thick CRCA sheet, floor mounting, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing switchgears/ACB/MCCB etc with locking arrangement, with back door openable (Screwed), including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands complete in all respect and including PCC work and provn of the following and including dismantling old LT panel:
SWASTHIK ENGINEERING WORKS (BID ID -3309163)
RISING ENGINEERING (BID ID -3310153)
SKY GROUP (BID ID -3309467)
Tropical Refrigeration (BID ID -3309370)
DELTA ELECTRICALS (BID ID -3309169)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .