Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC KAJANIBARI DINJAN PO DINJAN DIST TINSUKIA ASSAM786189 | DINJAN | TINSUKIA | ASSAM | 786189 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹38.1 L+₹48,230.88 (1.28%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹38.6 L+₹92,250.43 (2.45%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹39.1 L+₹1.4 L (3.81%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹39.5 L+₹1.8 L (4.91%)Rejected-Finance | L5 | Rejected-Finance Higher bid value |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
24 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
SPL REPAIRS TO BLDG No. T- 21 OF 1861 MED REGT AND PROVN OF STORAGE ACCN FOR FOL STORAGE BARRELES IN 502 ASC BN AND A REV WORK AT DINJAN MIL STN UNDER GE DINJAN
2022_MES_520532_1
C/8411/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹500
GE DINJAN
₹72,000
Yes
8 Jul 2022
28 Apr 2022
26 May 2022
28 Apr 2022
24 May 2022
17 May 2022
60 days
Amount
Dismantling of asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings with ridges complete all as specified and as directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed. Note : Colour of ridge shall be same colour as that of sheet used for roof.
S&F for steel work in tubular truses including special shaped washer etc using ERW or inductionbut welded tubes conforming to IS 1161 - 1979 grade St-240 complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F for rolled mild steel framed work as in trusses, purlins ,posts etc using joist, channel, angle, or tee sections, including distance pieces, cleats etc cutting, welding, drilling holes etc, steel section conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and as directed.
Dismantling timber scantlings 40 Sq.cm and over in section, in any position complete all as specified and as directed.
M&L for second class hardwood, scantlings, framed and fixed, wrought complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets and frame work any type complete all as specified and as directed.
S&F for aluminium anodised snap grid frame work of size 600mm x 600mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frame including providing two coats of white wash complete all as specified and as directed. Make of E-Board : Eternit Everest / Lafarge/ Armstrong/Visaka Industries Ltd.
GI frame work for false ceiling seamless comprising of galvanised iron perimeter channel 0.55mm thick with two unequal flangeds of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre / intermadiate channel 0.90mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre using 4mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40X3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 08mm thick seamless calcium silicate ceiling made out of 1800X1200mm size board of siliceous and calcareous materials reinforced with cellulose fibre fixed to the ceiling section with 25mm long self drilling and tapping screwshaving philips head with under head cutter at 200mm centre to centre, including finishing the joints of face board with specially formulated jointing compound and 48mm wide fibre tape to provide seamless finish complete all as specified and directed. Make of E-Board : Eternit Everest / Lafarge/ Armstrong.
M&L for applying two coat of oil bound distemper over a coat of primer and 2mm thick wall care putty on new surfaces of seamless calcium silicate ceiling complete all as specified and as directed.
Dismantling of timber fillets, rails, posts, rafters, purlins etc under 40 sqcm in section complete all as specified and as directed.
S&F for second class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails, cross sectional area exceeding 13 Sqcm and not exceeding 25 Sqcm complete all as specified and as directed.
Taking down chowkats or frame, not exceeding 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and as directed.
Taking down chowkats or frames, exceeding 1.5 Sqm but not exceeding 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and as directed.
Taking down shutters of any description exc 1 Sqm but not exceeding 2 Sqm each complete all as specified and as directed.
S&F for well seasoned second class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
M&L for 35mm thick second class hard wood Plain, framed, panelled shutters (any number of panels), with panels of 12mm thick veneered particle board medium density with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed, Sizes/section of members of shutters shall be as specified in SSR Part I, Section -8, clause 8.24 (a).
S&F for 30 mm thick, second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge, etc, divided in to squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded complete all as specified and as directed in SSR Part I Section 8 clause 8.24 (b).
M&L for mild steel framed work such as grills, gratings, gates etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-410-0 Gde E-250 complete all as specified and as directed.
S&F for solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification and drawing and as directed.
S&F for mild steel small articles using flat iron of size 25x3mm thick such as band, strap, hold fast, cleat, support, hook, hinges, base tie for door frame etc and other similar items conforming to Fe-290, (Gde E-165) complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and as directed.
S&F for 100 mm size, butt hinges, heavy weight, cold rolled mild steel complete all as specified and as directed.
S&F for 75mm size, butt hinges, heavy weight, cold rolled mild steel complete all as specified and as directed.
S&F for 150 mm size, aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed.
S&F for 75 mm long, aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic film complete all as specified and as directed.
S&F for 150 mm long, aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic film complete all as specified and as directed.
S&F for aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm anodised finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and as directed.
S&F for 3 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F for steel windows with side hung shutters including projection type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including painting with one shop coat of zinc chrome primer complete all as specified and as directed.
S&F for steel windows with side hung shutters including projection type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including painting with one shop coat of zinc chrome primer complete all as specified and as directed.
M&L for anodised aluminium section, medium anodic coating of grade AC 15 for frame of doors, windows, ventilators with one or more rebates including joining cleats for fixing etc complete all as specified and as directed.
S&F for squash court free standing glass back wall system as per internationsal standard made of 12 mm thick toughened glass with 4 panels, 1 door, 4 fines, fixtures and fitting and all the materials required for erection the glass walls. The height of the glass wall will be 2130mm above the finished floor level complete all as specified and as directed.
S&F for aluminium anodised (Deco) pattern grill 75X75mm mesh size for window, 7mm to 8mm thick, design No 102, including suitable F/H section frame, aluminium cleat, fixed with steel screw to window frame complete all as specified and as directed.
S&F for galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples including timber bead complete all as specified and as directed.
S&F for galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples including timber bead complete all as specified and as directed.
M&L for preparation of new untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
M&L for brick work using locally available first class bricks sub class 'B' bricks (old size brick), straight or curved on plan exc 6 m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) mixed with integral water proofing compound weight of cement as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid separately against respective item.
Supply only Liquid water proofing compound (ISI marked) complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar (1:4) on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and as directed.
M&L for rendering 5 mm thick in cement mortor (1:3) on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing as directed.
M&L for GI wire netting 0.90 mm dia, size of mesh 12 mm, lathing to wood or metal studding, joists, etc in walls, etc including all laps, cutting and waste as specified and as directed.
M&L rendering 15 mm thick on one side of lathing in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement as specified and as directed.
M&L rendering 10 mm thick on other side of lathing in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement as specified and as directed.
Demolition of reinforced cement concrete in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in slabs supported on wall, roof beams etc complete all as specified and as directed.
M&L for form work to soffits of suspended slabs such as roof slab landings and similar works not exceeding 200mm thick (horizontal or slopping) fair finished surfaces of concrete flat complete all as specified and as directed.
S&F for TMT steel bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
S&F TMT steel bars 6mm dia., and over cut to length, bend to shape required, including cranking, bending spirally as in nibs, stirrups, spacers and binders binding with and including providing mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for preparing new plastered surfaces of walls, etc and applying two coat of cement base paint over a coat of alkali resistant priming paint complete all as specified and as directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and as directed.
M&L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
M&L for preparing old decorated surfaces of walls, etc and applying two coats of APEX Ultra paint over a coat of primer as per manufacturer's instruction in squash court walls complete all as specified and as directed.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness. (below or above ground level) complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection, footpath, etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) making impressions of expanded metal whilst the concrete is green complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed.
M&L for non-skid, ceramic, coloured tiles 8 to 10 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor (1:4) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
M&L for non-skid, ceramic, coloured tiles 8 to 10 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,skirting, dado, vertical surface etc, including 10 mm thick screed bed in cement mortor (1:4) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
M&L for glazed, ceramic, coloured tiles of size 350mm x 450mm x 7mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortar (1:3) and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
M&L for vitrified, ceramic, coloured (light shade) tiles 10mm thick (square/rectangular) area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc, including 15 mm thick screed bed in cement mortar (1:4) and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
M&L for vitrified, ceramic, coloured (light shade) tiles 10mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm , as in skirting, dado, etc, including 10 mm thick backing of cement mortar 1:4 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading in layers n. exc 25cm, levelling, watering and well ramming as in soft/loose soil complete all as specified and as directed.
Removing excavated material to a distance not exc. 50 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and as directed.
Surface excavation averaging 15cm deep and not exceeding 30cm deep and getting out including removing the same to a distance n exc 50 metre, depositing as directed as in soft/loose soil complete all as specified.
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and as directed.
M&L for use and waste form work to sides of foundation, footings, bases of columns, plinth beams flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in foundation including footing, plinth beams, bases of column etc complete all as specified and as directed.
M&L for use and waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in columns, pillars, post and struts etc complete all as specified and as directed.
M&L for use and waste Form work to soffits and sides of lintel beam, roof beam, cantilevers, shelvers, for flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in beam, lintel, cantilevers etc complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 100 mm thick, cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in base of flooring/hard standing, etc, and finished the cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for 40 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in sub base etc omplete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in footpath, plinth protection, etc, finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed.
M&L for forming 12mm thick, expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ for 100mm thick floor complete all as specified and as directed.
M&L for precast machine pressed interlocking paver block conforming to IS- 15658-2006, 80mm thick, M-35 grade concrete with grey cement and no pigmen and made with electro-vibro technology of approved design, colour and securing laying on, set and jointed in dry sand including providing 75mm thick dry sand filling below paver blocks complete all as directed
M&L for chequered cement concrete tiles of size 30cm x 30cm x 25mm thick, as in floors etc, including 15 mm thick screed bed in cement mortar (1:6) and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
S&F for rolled mild steel in Plates (plain or chequered) channels fo grade Fe 410-W (Gde-E- 250) quality-A, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as speicfied and as directed.
S&F for steel rolling shutters, 1.25mm thickness of lath with out ball bearing, as specified including top cover, an-choring rod, hasp and staple and one shop coat of primer; erected in position as indi-cated, complete: push pull or manual type complete all as specified and as directed.
Supply only rolling ball bearing of suitable size for existing rolling shutters.
S&F for saftey lever lock mild steel 4 levers suitable for existing rolling shutters complete all as specified and as directed.
M&L for 20 mm thick damp proof course to horizontal or vertical surfaces including necessary form work in cement mortar(1:2) mixed with and including water proofing compound @ 3% or as per manufacturer's instructions including applying evenly two coats of blown type bitumen at the rate of 1.5 Kg per squre metre and blinding with clean dry sand @ 0.05 Cu.m per sqm complete all as specified and as directed. Note : WPC shall be measured and paid separately.
Dismantling of rotational moulded polyethylene water tank of capacity exceeding 500 litres but not exceeding 1000 Litres complete all as specified and as directed.
S&F for 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe complete all as specified and as directed.
Taking up or down 15 mm bore steel water tubing galvanised including connections from trenches/wall/floor/ceiling etc and keeping serviceable quantity in safe custody for re-use at same site or other site complete all as specified and as directed.
Taking up or down 20 mm bore steel water tubing galvanised including connections from trenches/wall/floor/ceiling etc and keeping serviceable quantity in safe custody for re-use at same site or other site complete all as specified and as directed.
Supply, laying, connection and testing, 16mm (outer diameter), CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches or on walls/ceiling or laying in floors complete all as specified and as directed.
Supply, laying, connection and testing, 20mm (outer diameter), CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches or on walls/ceiling or laying in floors complete all as specified and as directed.
S&F for CPVC brass threaded elbow suitable for 16mm outer diameter CPVC pipe complete all as specified and as directed.
S&F for CPVC brass threaded elbow suitable for 20mm outer diameter CPVC pipe complete all as specified and as directed.
S&F for CPVC brass threaded tee suitable for 16mm outer diameter CPVC pipe complete all as specified and as directed.
S&F for CPVC brass threaded tee suitable for 20mm outer diameter CPVC pipe complete all as specified and as directed.
S&F for CPVC brass threaded union suitable for 16mm outer diameter CPVC pipe complete all as specified and as directed.
S&F for CPVC brass threaded union suitable for 20mm outer diameter CPVC pipe complete all as specified and as directed.
S&F in repairs 15 mm bore, stop valves, cast copper alloy, chromium plated with long shank and cup, concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F for 15 mm bore, bib taps, cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F for PVC corner shelf complete all as specified and as directed. Make : Cat No T6010A1of Parryware / Hindware/ Cera.
S&F for casecade health faucet including hook and hose not less than 1.2 metre long complete all as specified and as directed. Make : Cat No T9937A1 of Parryware/ Hindware/Cera/ Somany/ Prayag.
S&F brass chromium plated tubular towel rail, D type, 60cm long, 20mm dia with brackets complete all as specified and as directed.
S&F in repairs new magnum parryware urinal port ( combo set ) of size 590 x 400 with spreader complete all as specified and as directed. Make : Cat No C0583 of Parryware/ Hindware/Cera/ Somany/ Prayag.
S&F in repairs new magnum parryware urinal port ( combo set ) of size 590 x 400 with spreader complete all as specified and as directed. Make : Cat No C0583 of Parryware/ Hindware/Cera/ Somany/ Prayag.
S&F for parryware urinal dome waste coupling complete all as specified and as directed. Make : Cat No T-9954A1 of Parryware/ Hindware/Cera/ Somany/ Prayag.
S&F in reapirs 32 mm brass cromimum plated bottle traps for wash basin with intel and outlet screwed for pipe or connections including nacessary packing and fixing, union and capy, PVC valve less syphonic duel type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and as directed.
S&F for vitreous china urinal partition white of size 310 x 700 mm complete all as specified and as directed.
S&F in repairs vitreous China wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe with PVC seat and cover complete but excluding flushing cistern & flush pipe including making good to disturbed surfaces of floor using concrete 1:2:4 type B0 and to match with existing specifications complete all as specified and as directed. Make : Cat No. C0287/0288 of Parryware/Hindware/Cera.
S&F in reapirs 10 litre capacity, PVC valve less syphonic duel type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and as directed.
S&F for vitreous china wash basin, size 550x400mm, white, flat back, with PVC waste pipe, CP waste coupling, chain, plug and porcelean stopper & backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed. Make : Cat No. C0406 of Parryware/Hindware/Cera.
S&F for 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F in repairs 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and as directed.
S&F for 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.
S&F for 75 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.
S&F for 75mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F for 110mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F for PVC SWR floor trap plain with grating including jointing with solvent cement, dia of outer 75mm complete all as specified and as directed.
S&F for PVC SWR gully trap plain with grating including jointing with solvent cement, dia of outer 125/110mm complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exc 10 cm but n.exc 20 cm girth complete all as specified and directed.
Taking down aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
M&L for point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLSH PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box (sunken type) 3mm thick hylam sheet cover fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including steel enameled conduit with all fittings and accessories of steel enameled conduit (like Tee, bend etc) complete fixed to walls/ ceiling etc. With and including 1.5 Sqmm (normal area) FRLSH continuity wire connecting to common earth point including steel terminal box (sunken type) 3mm thick hylam sheet cover fixed with suitable sizes cadmium plated iron screws and washers etc. For mounting switches, sockets, regulators etc complete for one light/ fan/bell/buzzer point controlled by one, one way switches complete all as specified and directed.
All as per item No 133 above but for one 3 pin socket outlet, 5/6 Amps on Independent board complete all as specified and directed.
All as per item No 133 above but for one 5/6 Amps, 3/5 pin socket outlet on the same board with other switches complete all as specified and directed.
All as per item No. 133 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 6/16 Amps switch socket combination on Independent board complete all as specified and directed.
M&L for concealed point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete with and including 1.5 Sqmm (nominal area) FRLSH PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point terminated in metal flush box of suitable size for mounting switches, sockets, regulators etc including cutting chases and making good by using cement mortar 1:4 complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and as directed.
M&L for point wiring with 2.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including steel enameled conduit with all fittings and accessories of steel enameled conduit (like Tee, bend etc) complete fixed to walls/ ceiling etc. With and including 2.5 Sqmm (normal area) FRLSH continuity wire connecting to common earth point including steel terminal box (sunken type) 3mm thick hylam sheet cover fixed with suitable sizes cadmium plated iron screws and washers etc. For mounting switches, sockets, regulators etc complete for one light/ fan/bell/buzzer point controlled by one, one way switches complete all as specified and directed.
All as per item No. 138 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 6/16 Amps switch socket combination on Independent board complete all as specified and as directed.
S&F for switch piano, 5/6 Amp single pole, flush type one way 230 volts bearing ISI marked complete all as specified and as directed.
S&F for socket outlet, 2 in 1, 3 pin, 5/6 Amps, flush type bearing ISI marked complete all as specified and directed.
S&F for switch socket combination, 2 in 1, 5/6 Amps, flush type, 240 volts bearing ISI marked complete all as specified and directed.
S&F for switch socket combination, 2 in 1, 6/16 Amps, 240 volts, bearing ISI marked flush type complete all as specified and directed.
S&F for ceiling rose, 3 phase/PVC/polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and directed.
S&F for stepped type(five steps) electronic fan regulator flush type complete all as specified and directed. Make : Cat No14502 of Anchor or equivalent.
S&F for bell push, flush type, 5 Amps 230 Volts, bearing ISI marked complete all as specified and as directed.
S&F for call bell, AC, 230 volts, single pole complete all as specified and as directed.
S&F in repairs lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F for LED lamp 9 Watt complete all as specified and as directed. Make : Havells /Philips/Bajaj /Surya/Eveready
S&F in repairs 20 Watt surface and wall mounting type LED batten with polycarbonate housing & integrated complete all as specified and as directed. Make : Havells/Philips/Bajaj/Century.
S&F for flameproof cum weatherproof Rotary switch as per IS/IEC 60079-1 : 2007 suitable for installation in hazardous location zone- 1 & 2 complete all as specified and as directed.
S&F for flameproof cum weatherproof switch socket and plug combination in LM6 of 16 Amps, 250 V with 2P + 1 Earth and horizantal pin type suitablble for installation in hazardous location zone- 1 & 2 complete all as specified and as directed.
S&F for flameproof cum weatherproof LED tubelight alongwith fixture, 1x16 W(4 feet) complete all as specified and as directed.
Supply, installing, testing and commissioning of heavy duty Exhaust fan, suitable for Single Phase AC supply, earthing etc, power input 150 W, 220/240 V, 380 mm sweep size, fan speed 1400 RPM, 4 nos. blades, copper winding, Air delivery minimum 3250 CMM and including all fixing accessories complete all as specified. Make: Cat NoEXHD380-4-1, of Crompton/ Bajaj/Khaitan.
Taking down unserviceable sub-main wiring up to 10 sqmm with rigid steel conduits/PVC casing-caping including cutting chases for taking out conduits and making good disturbed surfaces complete all as specified and as directed.
M&L for concealed Sub main wiring with two runs of single core 4 sqmm PVC insulated , unsheathed multistranded copper conductor 1100 volts FRLSH cable , including one run of 4 sqmm single core PVC insulated unsheathed multistranded copper conductor 1100 volts FRLSH cable as earth continuity drawn through and including one run of PVC conduit heavy duty and connected accessories etc and connecting to common earth dolly complete all as specified and as directed. NOTE:- Two runs of main cable,one run of earth continuity conductor cable and one run of PVC conduit will be measured as one unit for payment purpose.
M&L for sub main wiring with two run of 6 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH) Volts grade drawn through PVC casing-caping of suitable size, fixed to wall/ceiling etc including one run of 6 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FR) connected to common earth point complete all as specified and as directed. Note : (a) One run PVC Casing-caping, two run wiring cables and one run of earth wire will be measured as one length. (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets
M&L for sub main wiring with two run of 4 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping of suitable size, fixed to wall/ceiling etc including one run of 4 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (HRFR) as earth wire and duly connected to common earth point complete all as specified and as directed by Engineer-in-charge. Note : (a) one run PVC Casing-caping, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets
S&F in repairs, PVC casing caping of size 20-25mm single locking system, conforming to IS 14927 (Part-2), all fittings and fixing accessories complete all as specified and as directed. Make : Prestoplus/Harsh/Richa/Finolex.
S&F for 25 Watt LED building security light new generation energy saving and environtal friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07 including taking down unserviceable light fitting complete all as directed. Make : Havells/Philips/Bajaj.
S&F for 36 W LED recess mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation with separate replaceable electronic driver and opal diffuser included cutting-opening of celing any type & fixing arrangement for fitting complete all as specified and as directed. Make : Cat No LHEBLDP7INIW036 of Havells/ Philips/ Bajaj.
M&L for earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete inclduing taking down old one/ dismantling complete all as specified and as directed.
S&F in repairs factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end bus bar, TPN, 4 way, 415 Volts suitable for fixing MCBs including complete all as specified and directed.
S&F in repairs factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end bus bar SPN, 4 way, 415 Volts suitable for fixing 200 Amps MCBs including complete all as specified and directed.
S&F in repairs factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 8 way, 240 Volts suitable for housing 200 Amps MCBs including complete all as specified and directed.
S&F for MCB, four pole, 415 Volts, 63 Amps, "C" series, 10 KA breaking capacity complete all as specified and as directed. Make : Cat No TTPNC 50 - 63 of HPL/L&T/Havells.
S&F for MCB, SPN, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : Cat No : TSPNC6-32 of HPL/L&T/Havells.
S&F for MCB, 'C' Series, SP, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and directed. Make : Cat No. TSPC6 - 32 of HPL/L&T/Havells.
S&F in repairs test point terminal box made of gun metal or phosphorous bronze,size 75x75x25 mm, drilled and screwed and screwed including 03 Nos 8mm dia 25 mm long hexagonal head screwed including removing the existing old unsv one complete all as specified and as directed.
M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
M&L for bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and as directed.
Boring of holes horizontall for laying not less than 40mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hardstanding using trenchless technology complete all as directed. Note: Cost of accessories required for making hole/bore deemed to be included in the quoted rate.
M&L for 32 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/ road crossing/drain etc as in UG cable protection complete to walls and ceilings or laid in floors complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 4 core, nominal cross sectional area of main conductor 25 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 6 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
M/s GANDHESWAR PHUKAN
M/S BORAH BROTHERS
STANDARD ELECTRIC WINDERS
M H KHAN
R.D.CONSTRUCTION
FREEZCON
R D Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .