GE (East) Allahabad
GE (East) Allahabad Teliyarganj (UP)
Repair/maint/shifting of elect line/poles near Div HQ Sports Complex and Joginder Singh Stadium at Old Cantt Allahabad under GE (East) Allahabad
2021_MES_428967_1
3020/JO/44/E3
Limited
Job Works
Works
30 days
GE (East) Allahabad
Please refer Tender documents.
1 document required · 1 mandatory
₹0
Exempted
23 Mar 2021
8 Mar 2021
15 Mar 2021
8 Mar 2021
13 Mar 2021
8 Mar 2021
Amount
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in hard / dence soil all as specified and as directed. 81 Cum
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick with excavated soils complete all as specified and as directed. 48.6 Cum
Removing of surplus soil excavated material n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point all as specified and as directed. 32.4 Cum
Supply and spread clean dry river sand in trenches for cable cushioning all as specified and as directed. 24.30 Cum
Supply and lay well burnt bricks sub class ‘B’, Old size in trenches for cable protection all as specified and as directed. 2600 Each
Supply and laying 50mm bore GI pipe “Light Grade” in trenches, under floors, roads, along poles for protection of cables, including sealing ends all as specified & directed. 30 RM
Supply, laying, commissioning, jointing & testing 70 sqmm, 3.5 core, XLPE cable screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor complete all as specified &directed. Make : Havells, Nicco, Kalinga, Premium, Universal. 264 RM
Supply, laying, commissioning, jointing & testing 25 sqmm, 4 core, XLPE cable screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor complete all as specified & directed. Make :Havells, Nicco, Kalinga, Premium, Universal. 164 RM
M&L for steel tubular swaged pole complete with mild steel base plate 30 x 30cm x 6mm thick, finial taper plug, bolts, nuts, screws as per IS-2713 (Part-II) 1980 made out of mild steel tubing complete type 410SP-31(9.0 M long) including painting with two coats of aluminium paint over one coat of red oxide primer on exposed portion and with two coats of bituminous paint on embedded portion in concrete including marking number on pole. 1 Each Note - (i) Excavation in soft/loose soil including returning filling and removal of surplus soil will be deemed in unit rate. (ii) PCC will be measured separately in respective items.
M&L for GI bracket for street light fittings fabricated with GI tubing 50/55 mm dia “medium grade” 1.2 m long and bending to angle of 120 degree including mild steel flat iron clamp fabricated with mild steel flat iron 32 x 5 mm with nut, bolts & washer suitable for fixing of GI bracket on PCC/ steel poles complete all as specified and directed. 1 Each
Supply, connect & testing LED street light fittings of 90 Watt, high pressure die – cast aluminium hosing, with minimum 105 lumen/watt system efficacy, heat resistant toughened glass, with frame IP66 protection, better optics for uniform distribution roadway luminaries complete. Make : Philips Cat part No – BRP410LED 094CW HEMR FG S2 PSUGR, Crompton Cat Part No – LSTN-90-CDL-A, or equivalent Havells Cat Part No – LHETBXU7PA6J090. 1 Each
S&F cable looping box shock & rust proof of external dimension 230mm x 170mm x 105 mm comprising of MCB SP 6 Amp – 01 No, 4 way heavy duty PVC insulated connector-01No and flat iron clamp of size 25 x 3 mm with hinged cover and locking arrangement complete all as directed by Engineer-in-Charge. Make :Legrand/Hager/Hensil. 1 Each
M&L for cement concrete in foundations, filling and mass type D2 (1:2:8) 40mm graded aggregate for using pole foundation. 0.2 Cum
M&L for cement concrete type C2 (1:3:6) 40mm graded aggregate for using pole cooping. 0.09 Cum
Supply, install, test and commissioning of LT out door type kiosk pedestal panel board of size 60cm x 60cm x 30cm for 3 phase 4 wire 415 volts 50 HZ system, made out of 3.15 mm thick CRCA sheet with powder coated mounted on PCC platform, hinges with locking door arrangement, suitable cable entries holes at bottom and consisting of the following : 1 Each Job
Aluminium bus bar of rating 200 Amps capacity 4 Nos (TPN) mounted on supporters with shrouded by PVC insulated and arrangements for incoming /outgoing connections. 1 Set
PANDEY ENTERPRISES
SHUBHAM CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_478885.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .