| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.3 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹48.8 L+₹1.0 L (2.13%)Rejected-Finance | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹49.0 L+₹1.2 L (2.55%)Rejected-Finance KAJANIBARI DINJAN PO DINJAN DIST TINSUKIA ASSAM786189 | DINJAN | TINSUKIA | ASSAM | 786189 | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹49.2 L+₹1.4 L (2.89%)Rejected-Finance | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹49.5 L+₹1.7 L (3.48%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L5 | Rejected-Finance Higher bid value |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
24 Feb 2022, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
PROVN OF CENTRAL BATHING POINT NEAR BLDG NO T-6/9-11 AT GANESHBARI AND SPL REPAIRS TO PARA SHED OF BLDG NO P/4 AT MOHANBARI INCLUDING MINOR WORK AT NCC DIBRUGARH UNDER GE DINJAN
2022_MES_505176_1
C/8382/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹500
GE DINJAN
₹86,000
Yes
16 Mar 2022
2 Feb 2022
26 Feb 2022
2 Feb 2022
24 Feb 2022
17 Feb 2022
Amount
Surface dressing not exceeding 15 cm deep as in soft/loose soil complete all as specified and as directed.
Surface excavation averaging 15cm deep and not exceeding 30cm deep and getting out complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distancenot exceeding 50m and making good surface in soft/loose soil as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading in layers not exceeding 25cm, levelling, watering and well ramming as in soft/loose soil complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and as directed.
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling, sub base of floors and mass concrete, etc complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and coping of pole / pedestal, etc complete all as specified and as directed.
S&F for steel work in tubular truses including special shaped washer etc complete using ERW or inductionbut welded tubes conforming to IS 1161 - 1979 grade St-240 complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F for rolled mild steel framed work as in trusses, purlins, posts etc using joist, channel, angle, or tee sections, including distance pieces, cleats etc cutting, welding, drilling holes etc steel section conforming to Fe-290 (Gde-E-165) quality-A complete all as specified and as directed.
S&F for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and as directed.
M&L for mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges complete all as specified and as directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed. Note : Colour of ridge shall be same colour as that of sheet used for roof.
S&F for 0.71 mm thick pain aluminium sheeting of alloy 31000 H4, as in ridges, valley gutter, drip and straighting flashing (Lenth and girth as fixed) complete all as specified and as directed.
S&F for mild steel screw bolts of 11 to 15mm dia of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 10cm long complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
M&L for brick work using locally available first class bricks sub class 'B' bricks (old size brick), straight or curved on plan exceeding 6 m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed
M&L for rendering 15 mm thick in cement mortar (1:6) on other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar (1:4) on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant cement primer complete all as specified and as directed.
M&L for preparation of old or previous plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant cement primer complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and as directed.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness. (below or above ground level) complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection, footpath, etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) making impressions of expanded metal whilst the concrete is green complete all as specified and as directed.
M&L for hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub base etc complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposing the rubbish off the premises complete all as specified and as directed.
M&L for glazed, ceramic, coloured tiles of size 450mmx350mmx7-8mm thick, on vertical surfaces, including 10 mm thick backing of cement mortor (1:4) and set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed.
M&L for granite stone slab (of any type) 18 to 20 mm thick, machine cut, as in cooking platform bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed in cement mortar (1:6) and cutting, rounding to edge of slab, polishing complete all as specified and as directed.
M&L for granite stone slab (of any type) 18 to 20 mm thick, machine cut, as in skirting, dado, etc, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 10 mm thick screed bed in cement mortar (1:4) and cutting, rounding to edge of slab, polishing complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20 to 25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing & 15 mm thick, screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L for machine cut kota stone, 20 to 25mm thick as in riser of steps, skirting, dado and pillar laidover cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing & 10 mm thick, screed bed in cement mortar (1:4) complete all as specified and as directed.
M&L for chequered cement concrete tiles of size 25cm x 25cm x 20mm thick, as in floors etc, including 15 mm thick screed bed in cement mortar (1:6) and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B-1, (using 20 mm graded stone aggregate) as in lintel upto 1.5m span, cills and other similar band, plinth course, parapet, railing upto 60cm height, coping, kneelers, bed plates etc including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and as directed.
Demolition of reinforced cement concrete in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for use & waste form work to sides of foundation, footings, bases of columns, plinth beams flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in foundation including footing, plinth beams, bases of column etc complete all as specified and as directed.
M&L for use & waste formwork to sides of pillars, posts, struts, piers, columns and stanchions for flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in columns, pillars, post and struts etc complete all as specified and as directed.
M&L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in slabs supported on wall, roof beams etc complete all as specified and as directed.
S&F for TMT steel bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
S&F for TMT steel bars 6mm dia, and over cut to length, bend to shape required, including cranking, bending spirally as in nibs, stirrups, spacers and binders binding with and including providing mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F for 110 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length without ears, with rubber ring joints laid in trenches, floor or fixed to wall complete all as specified and as directed.
S&F for 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.
S&F for mild steel flat iron clamps etc, any size cut to shape as directed, drilling holes, notching for wire, 100mm bore pipe, etc., including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
S&F for 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe all as specified in SSR Part I and as directed.
S&F for 20 mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and as directed.
S&F for 15 mm bore, stop valves, cast copper alloy, chromium plated with long shank and cup, concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F for 15mm bore, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
Supply, laying, connection and testing, 15mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239 (Part -2):2011 and fixtures complete fixed to walls and ceilings or laid in floors, etc complete all as specified and as directed.
S&F for 125 mm long, shower rose, brass chromium plated, swival type, including fixing to 15 mm bore steel tubing or union complete all as specified and as directed.
S&F for 20 mm bore, Brass chromium plated, tubular towel rail, D type, 60 cm long between flanges with brackets complete all as specified and as directed.
S&F for vitreous china wash basin, size 550 x 400mm, white, flat back, with PVC waste pipe, CP waste coupling, chain, plug and porcelean stopper & backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed. Make : Cat No C0406 of Parryware /Hindware/Cera.
S&F for 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) complete, (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
M&L for concealed point wiring with 1.5 Sqmm (nominal area), FR PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete with and including 1.5 Sqmm (nominal area) FR PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point terminated in metal flush box of suitable size for mounting switches, sockets, regulators etc including cutting chases and making good by using cement mortar 1:4 complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed.
All as per item No 65 above but for one 3 pin socket outlet, 5/6 Amps on Independent board complete all as specified and as directed.
All as per item No 65 above but for one 5/6 Amps, 3/5 pin socket outlet on the same board with other switches complete all as specified and as directed.
All as per item No. 65 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 6/16 Amps switch socket combination on Independent board complete all as specified and as directed.
S&F for switch piano, 5/6 Amp single pole, flush type one way 230 volts bearing ISI marked complete all as specified and as directed.
S&F for socket outlet, 2 in 1, 3 pin, 5/6 Amps, flush type bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 2 in 1, 5/6 Amps, flush type, 240 volts bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 2 in 1, 6/16 Amps, 240 volts, bearing ISI marked flush type complete all as specified and as directed.
S&F for ceiling rose, 3 phase/PVC/polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and as directed.
S&F for stepped type ( five steps), 230 V electronic fan regulator flush type (Socket Type) complete all as specified and as directed.
S&F for 18 watt surface and wall mounting type LED batten with polycarbonate housing & integrated including taking down old unserviceable light fitting complete all as specified and as directed. Make : Havells/Philips/Bajaj/CG/Crompton.
S&F for factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 8 way, 240 Volts suitable for housing 200 Amps MCBs including complete all as specified and as directed.
S&F for factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 4 way, 240 Volts suitable for housing 200 Amps MCBs including complete all as specified and as directed.
S&F for MCB, SPN, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make: Cat No. 408609 to 408617 of Legrand or equivalent.
S&F for MCB, 'C' Series, SP, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make: Cat No. 408587 to 408595 of Legrand or equivalent.
S&F for MCB, four pole, 415 Volts, 5 to 32 Amps, breaking capacity 10 KA complete all as specified and as directed. Make: Cat No. 408702 of Legrand or equivelant.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc 10 cm but not exceeding 20 cm girth complete all as specified and as directed.
Taking down unserviceable sub-main wiring up to 10 sqmm with rigid steel conduits/PVC casing-caping including cutting chases for taking out conduits and making good disturbed surfaces complete all as specified and as directed.
M&L for sub main wiring with four run of 10 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size, fixed to wall/ceiling etc including two run of 10 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
S&F for 45 watt LED building security light new generation energy saving and environtal friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07 including taking down unserviceable light fitting complete all as directed. Make: Cat No SPSP045C0920 of CENTURY /Havells/Philips/Bajaj/CG.
S&F in repairs, Integral compact wide beam high performance LED flood light luminaire with IP 66 protection, tampered protective toughened glass cover, thermal shock impact resistance cover, epoxy black powder coated finish, high purity , 100W LED of luminous efficiency greater than >120 Lm/watt with built in control gear including connecting up with 2.5 Sqmm multistranded Aluminium/Copper conductor cables of suitable length with fixed to pole/wall, etc and testing complete all as specified and as directed. Make :- JETA IRIS FLS100WLED757APWBLTG of Havells/ Crompton/ Jaquar /Phillips /Century.
S&F in repairs, Integral compact wide beam high performance LED flood light luminaire with IP 66 protection, tampered protective toughened glass cover, thermal shock impact resistance cover, epoxy black powder coated finish, high purity , 70W LED of luminous efficiency greater than >120 Lm/watt with built in control gear including connecting up with 2.5 Sqmm multistranded Aluminium/Copper conductor cables of suitable length with fixed to pole/wall, etc and testing complete all as specified and as directed. Make : JETA QUANTO PLUS FLP70WLED757SYMLENS of Havells /Crompton /Jaquar /Phillips /Century.
S&F for street light bracket arm of length not less than 1.5 m made out of GI tubing,32 mm bore with necessay modification to house the above fittings, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on steel surfaces complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete all as specified and as directed.
M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
M&L for bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and as directed.
M&L for 40 mm dia GI pipe ‘light grade’ with all fittings for protection of cable laid on road crossing, drain crossing, laid in floor or fixed to iron structures/poles complete all as specified and as directed.
Boring of holes horizontall for laying not less than 40mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hardstanding using trenchless technology complete all as directed. Note: Cost of accessories required for making hole/bore deemed to be included in the quoted rate.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, 3 core with reduced neutral conductor (3 1/2 Core), nominal cross sectional area of main conductor 16 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, connection and testing, 40mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures complete laid in trenches etc complete all as specified and as directed.
Supply, laying, connection and testing, 25mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures complete laid in trenches etc complete all as specified and as directed.
Supply, laying, connection and testing, 20mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part -1):2004 with all fittings conforming to IS 1239(Part -2):2011 and fixtures complete laid in trenches etc complete all as specified and as directed.
M&L for 25 mm dia gate valve cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union including taking down old unserviceable valve complete all as specified and as directed.
M&L for 40 mm dia gate valve cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union including taking down old unserviceable valve complete all as specified and as directed.
Cutting the existing GI pipe of 40/50mm bore and making thread, welding and necessary arrangement for taping of new pipe line of 25/40 mm dia complete all as specified and as directed.
S&F for 20mm bore, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
Construction of brick masonry valve pit of size 40cm x 40cm x 40 cm (internal dimensions)including concrete work with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover made out of 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engnr-in-Charge.
Supply, installation, testing and commissioning for FPC type Solar Hot Water System based on indirect transfer of heat, 500 litre capacity comprising of solar flat collector cover plate made of minimum 4mm thick toughened glass, collectors stand assembly, PUF insulated hot water storage tank of suitable capacity with heat exchanger, electrical back up with suitable capacity of electrical heating element and various other components as per section 26 of SSR part-I and as per manufacturers instruction complete all as specified and as directed. Note:- (i) The cost of installation as per manufacturers recommendation deemed to be included in the quoted rate/percentage. (II) Structural steel work for mounting cold water tank and hot water tank will be provided as per recommendation of OEM and will be measured and paid separately in respective items of Sch 'A.
M/S. NOBIN RAJKHOWA
M/S CHANDAN ENTERPRISE
D. D. Construction
STANDARD ELECTRIC WINDERS
R.D.CONSTRUCTION
MAZUMDAR ENTERPRISE
FREEZCON
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .