Provision of EI alteration at JTJ Yard in connection with Safe running of VB, container and other Freight trains without any speed restriction over SBC main line & inconnection with Doubling of By-Pass line between Tirupattur - Somanayakkanpatti at JTJ along with provision of Speed enhancement at JTJ yard.
TBM-SG-CN-2026-27-03-OT
TBM-SG-CN-2026-27-03-OT
Open
11 Months
Tiruchirappalli, Tamil Nadu
₹0
₹24.6 L
1 Jun 2026
1 Jun 2026
9 Jun 2026
Item Breakup - A1-SOR Items
2.00 375562.03 grade computers (Similar to Moxa V2406 or better) with all accessories such as key board, mouse, antivirus etc . o f industrial grade as per approved Specification as recommended by latest RDSO Specification(RDSO/SPN/192 or 203 or latest) for EI
2.00 214096.98 VDU and Embedded PC. This includes supply of 2Nos of 110VDC/24DC, 10A DC- DC converter a n d 2 N o s o f 110VDC/110V AC, 500VAInverter in (1+1) configuration. (as per Technical Specification enclosed)
1.00 948672.10 per enclosed drawing No PROJ/SG/MS/70/2019 - work space (as approved by engineer in charge) with control desk for 2 monitors, 2 operators & one module to be provided for storage - should include space for housing Two nos of Embedded PCs, 2 nos FDMS and their Power supply arrangement for with proper ventilation with two chairs (as per Drawing enclosed or as per site requirement)
of installation, commissioning, testing, troubleshooting and in diagnosing faults u s i n g diagnostic tools/flow charts including supply of necessary documents. (Per Unit= 60 Man Days)"
2.00 305105.92 Acceptance test f o r a n y station having Distributed EI configuration"
2.00 529000.45 drawings/ Plans, Ru l e Diagrams, Station Working Rules, CRS Documents, TSAA documents" DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
1500.00 mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above"
20.00 power diagrams, cable plan, bonding plan etc in Auto Cad 200o or latest. The drawings shall be prepared in A3/A2/U size as required by Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad very carefully and submit one copy of check print along with the soft copy in CD. The drawings shall be checked and returned by Railways indicating corrections if any. The corrections have to be made and final copy submitted in A3/ A 2 / U size as required by Railways along with the final soft copy in CD. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways. a) Preparation of soft copy in AUTO CADD from A3 size hard copy
2.00 494420.00 96 Analog inputs as per RDSO spec .no IRS-S- 99/2006 o r latest including Power Supply and Back-up arrangements(This w ork does not includes wiring o f inputs fro m Relay to Intermediate tag block & from intermediate tag block to Datalogger equipment)
1.00 analysis of fault and generating reports for Datalogger installed a t stations. A s per Technical Specifications." DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
2.00 Electronic Interlocking system equipment
2.00 converter suitable to insert in the Datalogger Eurorack for inter-linking Datalogger/MFEP
Installation, Commissioning of Failure Alarm SMS system integrated w i t h Datalogger. This includes a) Software and configuring the S M S features i n t h e NMDL/CMU. b ) GSM Modem for Each Network. c)PCI Serial Port Adopter card."
2.00 512 Digital & 9 6 Analog data logger. This includes transportation of materials to Site location and provision of Ladder and cable trough arrangements including connection to the BRC earth. Also includes carrying out of pre-commission checklist and Networking of datalogger. (This schedule doesn't cover wiring and preparation of Simulation chart)"
500.00 Wago block to Datalogger. Necessary Wagos required is included as per schedule
100.00 to Datalogger. Necessary Wagos required is included as per schedule
1.00 analysis of fault and generating reports for Datalogger installed at stations)
2.00 Device as per RDSO Spec. No. SPN/165/ 2023, Version 4.0 Amdt.1 or latest (Lightning and Transient surge protection for power line). The system shall have stage1 (class B) and stage 2 (class C) type against Lightning electromagnetic Impulse configuration. The protection of Type 1 and 2 against Lightning electromagnetic Impulse (LEMP) and other high surge, shall be provided at the incoming of the power line at the stations, LC gates before the power equipment's as per the instructions of Engineer in-charge at site. Supply of surge protection with Potential free contacts shall be of approved make like OBO, DEHN, PHOENIX, LPT or better make. All other miscellaneous materials required for the work shall be supplied by the contractor. (as per Technical Specification enclosed)
10.00 Class D Surge Protection Device f o r 24V DC/48V DC (spark gap type), with Potential Free contacts and installed as per the instructions of t h e Engineer i n charge at site ( OBO, DEHN, PHOENIX, LPI, ZOTUP, H A K E L or better make).All other miscellaneous m a t e r i a l s required for installation s h a l l b e s u p p l i e d b y the contractor. DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
10.00 Class D SPD of Operating Voltage of 110V AC/DC with Potential Free contacts and installed as per t h e instructions o f the Engineer in charge a t site (OBO, DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make). All other miscellaneous materials required for installation shall b e supplied by the contractor.
30.00 RDSO Specification RDSO/SPN/197/2008 or l a t e s t ( a s p e r Te c h n ic a l Specification enclosed)
300.00 size 25mm x 3mm for Down conductor from Franklin Rod to Maintenance free earth. This work includes installation of insulated stand-offs a t e v e r y 1 Mtr. interval f o r fixing the Copper tape. This work also includes Exothermic welding of Copper tape t o the Franklin rod and the maintenance free earth for high conductivity. (All the materials required for t h e above work shall be supplied by the Contractor)
7.00 483896.58 Active Class ' A ' Protection with Lightning E v e n t Counter a s p e r R D S O S p e c No. SPN/197/2008 w ith Three Ye a r Warranty (Make Erico, LPI or Similar). This schedule includes s u p p l y o f 3 0 m t r s c a b l e for connecting Air terminal & earth as specified by O E M . ( a s p e r Technical Specification enclosed)"
55.00 no SG/CN/02/13
55.00 drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor].
10.00 of size 1050x25x3mm as given in enclosed Box drawing t o connect a l l cable armours to earth point with suitable nuts/bolts as given below. A) G I nuts/bolts o f size 8x25mm w i t h Two flat a n d o n e spring washer o f 23set. B ) GI nuts/bolts o f size 12x40mm w i t h t w o flat and one spring washer of 02set as per site incharge" DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
5.00 of size 550x25x3mm as given i n enclosed Box drawing t o connect a l l cable armours to earth point with suitable nuts/bolts as given below. A) G I nuts/bolts o f size 8x25mm w i t h Two flat a n d o n e spring washer o f 23set. B ) GI nuts/bolts o f size 12x40mm w i t h t w o flat and one spring washer of 02set as per site incharge"
2.00 Surge Protection Devic e . T h i s includes transportation o f m a t e r i a l s t o site. Installation t o b e carried o u t a s p e r the direction o f Railway Engineer. Necessary copper wire for Power Wiring and connecting the earth to be supplied as part o f the schedule. All other miscellaneous materials required for installation shall be supplied by the contractor."
2.00 150841.73 D e t e c t o r a s p e r R D S O Specifications RDSO/SPN/256/2002 or latest
2.00 110V DC/24-40V, 5A a s p e r RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest
2.00 110V DC/24-40V, 10A as per RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest
and Equipment Stand a t stations/Huts/Power room at station. As per drawing enclosed
180.00 2V, 300Ah - 1 c e l l a s p e r RDSO Specifications IRS S: 93/96 with Amnd 1 or latest
2.00 - 1A transformer rectifier conforming to RDSO spec. IRS S 91/2014 with latest Amendment in power room for LVR"
2.00 1307398.11 per RDSO Specifications RDSO/SPN/165 or l a t e s t ( T h i s schedule d o e s n o t include Batteries) As per drawing enclosed
240.00 cells of t h e following capacities with necessary inspection a s per specification/ drawing/ description enclosed in this document.b)Supply o f Secondary c e l l s - 2V-80AH capacity
Numbers DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
2.00 161805.53 suitable power equipment s t a n d i n the power room at stations (up to 5 roads) using M.S.Angles 65mmx65mmx8mm and M S flats 50mmx6mm c o v e r e d with 100mmx50mm hardwood reapers, installation o f power equipments and wiring the same using wire PVC 7/1.4mm and 3/0.75mm copper as per approved w i r i n g diagram, manufacture of power panel using phynolic sheet 1200mm x 1200mm x 10mm and erecting it using MS angles 25mm x 25mm x 6mm and fixing of meters, stabilizer and ammeter by pass switches, H RC fuse blocks, P B T terminals 60mm centre a n d connecting t h e power equipments t o t h e p o w e r p a n e l a s per approved power diagram, i n t h e power room. T h i s w o r k includes installation of power distribution diagram b o a r d using phynolic sheet 6mm thick of size 1200mm x 1200mm w i t h A l u m i n i u m grooved channel frame i n t h e r e l a y r o o m . The particulars shall b e digitally u s i n g good quality laminated g u m sheet. (Supply of power equipments l i k e battery charger, transformers, transformer rectifiers, v o l t a g e stabilisers, D C - D C convertor, invertors e t c . , i s n o t included i n this schedule).
100.00 RDSO specification N o 18/2004 o r latest w h i c h consists a s p e r following: a) 2 Conductor disconnect type terminal block as per Model No wago 280-870 or similar - 6 Nos b ) End Plate type 280-374 suitable for disconnect terminal of Model No wago 280-870 or similar - 1 No c) End Stop terminal block type as per model no wago 249-117 or similar - 2 Nos d) Shorting Links (16A) as per Model wago 280-402 or similar- 1 No"
1000.00 2.5sq.mm 2 IN 2 OUT type disconnect type of Wago/Phoenix make or similar along with accessories a s p e r RDSO Spec.No.RDSO/SPN/189/2004/ rev 2 or latest.
75.00 indication upto 2.5sq.mm screw type 1 IN 1 OUT ( Suitable 400mA, 630mA, 1A, 1.6A, 2A, 4A, 6.3A, & 10A) (Without Fuse) as per RDSO Spec.No.RDSO/SPN/189/2004/ rev 2 or latest."
1.00 stripper for modular terminal. These tools shall b e o f Wago/Phoenix make o r similar and model suitable for the modular terminal supplied
100.00 1A, 1.6A, 2A, 4A, 6.3A & 10A) DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
1.00 to'KILBURN' make capacity 3.5 to 4.5 Lits. per hour, with two detachable heating elements of 1500W each to work on 230VAC, single phase, fitted with automatic cut-outs and removable connectors, with Stainless Steel boiling chambers, condenser pipe, toughened glass lid; Distilled water plant, tank 200 Litres capacity similar to sintex make, GI pipe 25mm dia, power plug with socket, regulating valves, jelly, cement, sand and other materials shall be supplied by the Contractor"
1.00 provision of water supply connection from water t a p t o water tank, water t a n k to distilled water plant using G.I Pipes 25mm dia and with regulating valves, provision of separate power supply socket and wiring. This work includes fixing of 2 Nos. of rails on the wall and grouting a s instructed by Railway representative at site. (Cut rails will be supplied by Railways)."
2.00 Detector. T h i s includes transportation of materials to Site location and provision of c a b l e t r o u g h arrangements including connection to the BRC earth.Also includes carrying out of pre-commission checklist.
2.00 includes arrangement of OEM engineer for checking the Installation and carrying out adjustments of I P S m o d u l e s and submission o f Pre- commissioning checklist
2.00 per RDSO Specification No. RDSO /SPN /165 or latest.This w o r k includes transporting the IPS from the Stores by loading without any damages and installation of the same at site. This also includes w i r i n g o f a l l modules, proper earthing of equipments and all other w o r k s c o n n e c t e d f o r t e s t i n g and commissioning o f t h e s a m e . Necessary p o w d e r e d c o a t e d A l u m i n i u m ladder arrangements i n c l u d i n g cable trench, pipes, bolts, a n d o t h e r accessories is included in this schedule.[Earthing i s not covered under this schedule]
500.00 along w ith accessories w i t h provision of fixing holes on hylam sheet/side angles of Location Box and fixing by Galvanized nuts and bolts. This includes fixing of DIN channel for cable termination on Modular terminal
24000.00 i n s u l a t e d Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4
15000.00 Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
10000.00 Armoured, unscreened, underground Railway Signalling Copper c a b l e a s per spec IRS.S.63/2014(Rev.4.0) or latest"
600.00 Flexible Annealed Pure Copper (APC) PVC Insulated Unsheathed Single Core Cable as per IRS:S: 76/89 with all latest amendments
600.00 APC PVC insulated copper cable a s per IS 694
600.00 APC PVC insulated copper cable a s per IS 694
1000.00 B i n d e r T a p e d a n d P V C Sheathed Unarmoured Cable as per IRS:S: 76/89 with all latest amendments"
5000.00 0.9MM Dia a s per spec IRS:TC 30-05 with amd 5 or latest
7000.00 p e rR D S O Specification RDSO/SPN/TC/110/2020 Rev. 0 or latest
500.00 Sheathed armoured Jelly Filled Telephone Cable w i t h Poly-AL Moisture Barrier, 20 Pairs, 0.63 MM Conductor Diameter as per RDSO Specification No. IRS:TC-41/97 with amendment 1 or latest
500.00 Sheathed armoured Jelly Filled Telephone Cable w i t h Poly-AL Moisture Barrier, 50 Pairs, 0 . 6 3 M M Conductor Diameter as perRDSO Specification N o . IRS:TC-41/97 with amendment 1 or latest
30.00 patch cords w ith 0 d b adaptors a s TEC spec G/OJC-O1/03 JAN 99 or latest.
30.00 PC/LC- PC t o FC-PC/SC-PC/LC-PC s o a s to suit for switches and FMS supplied)"
500.00 or UL or CE3P certified panduit or Systimax or R&M or AMP or Molex or Krone Or D-LinkMakes
5000.00 Flame retarding type Single core flexible wire 16/0.2 mm dia. With annealed, tinned copper conductor of colour code ( Red =50%,Black=50%,) a s p e r IRS-S-76/89 Amd- 3(with amdt. upto date if any).
1.00 button switches a n d having conference facility. Model No AM-10 similar to Epsilon, Telelinks or better"
10.00 Thermo shrink jointing kit (RDSO specs No TC/77/2012 ( Re v. 3 ) w i t h amendment N o . 1 & 2 o r latest.& jointing k i t t o be inspected b y RDSO) f o r 4 / 6 q u a d cable normal joint. The work includes excavation o f joint p i t o f s i z e 1mX1.5mX1.5m and closing the same after completion of cable j o i n t a s p e r t h e instruction o f Railway representative at site. DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
2.00 c o m p l e t e f o r 6 Q u a d c a b l e s using thermoshrink jointing kit for LC's/stations
4.00 enclosure for armoured optical fibre cable c o n f o r m i n gt o RDSO spec.RDSO/SPN/TC/68/2014 rev2.0 or latest
16.00 enclosure for armoured optical fibre cable c o n f o r m i n g to RDSO spec.RDSO/SPN/TC/68/2014 rev2.1 or latest
210.00 RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" as p e r t h e instructions o f Railway representative a t site.) as per drawing enclosed
500.00 covering of G I Pipes/cables. Providing & L a y i n g in position c e m e n t concrete of specified proportion including c o s t of cement, centering a n d shuttering with 1:3:6 composition 1 Cement: 3 Sand: 6 grade stone aggregate 2 5 m m nominal size) (Cement, M-Sand, stone jelly of 25mm and all o t h e r m i s c materials required for the work should be supplied by Contractor).
150.00 board (10 pair/ 20 pair/50 pair) Cables in 1" PVC conduit/case caping and clamping on the wall/Roof t o p s / S h e l t e r s with suitable clamping and hose to be provided where ever bends/ curves (PV C conduit/ Case capping and other accessories to be supplied by the contractor)
6000.00 soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying o f c a b l e s i s not included in this schedule)
1000.00 soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.5 Mtrs. (Laying o f c a b l e s i s not included in this schedule.)
100.00 feet thickness - 0.5 feet thickness and to a width of 0.3 Mtr using cutter machine and removal o f RC C slabs o n t h e Passenger Platform, trenching t o a depth o f 0.6m to a c c o m m o d a t e t h e a d d i t i o n a l cables, replacing the slabs removed after the cables are l a i d a n d replastering with cement mortar, refilling the trench by ramming and consolidating i t a s p e r the instructions of Railway Representatives at site. (Laying o f cables i s n o t included in this schedule). DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
650.00 for track crossing of cables, refilling of trench by ramming and consolidating it as p e r the instructions of Railway representative at site after l a y i n g of D W C / RC C p i p e s . During excavation of trench, i t h a s t o b e ensured that the excavated soil does not mix with the ballast available. The depth o f 1 m trench shall b e from t h e bottom o f sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule).
100.00 for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming a n d consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f DWC/RCC pipes with couplers/collars is not included in this schedule).
450.00 cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor.
550.00 cable laying in hard rocky area with off sets at b o t h e n d s d u l y supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall b e closed w i t h brick masonry abutments work so that no cable is exposed, The work shall be carried out a s p e r the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, and all other miscellaneous materials required f o r t h e w o r k s h a l l be supplied by the Contractor].
f signaling/power/ Metre telecommunication c a b l e s a s p e r cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc. (Supply o f cables i s n o t included i n this schedule). DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
6000.00 0.3m width throughout, with earth after laying of cables, a n d consolidating the trench by ramming and levelling."
1000.00 0.5m width throughout, with earth after laying of cables, a n d consolidating the trench by ramming and levelling."
210.00 size 300mmX300mm, casting o f concrete f o u n d a t i o no f size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation a n d r e fi l l i n g t h e p i t and consolidating i t b y ramming. T h e cable markers shall be provided at an interval of 20 Mtrs. within station limits and 5 0 Mtrs. outside station limits throughout the cable r o u t e , diversions a n d a l s o a t every track/road crossing."
100.00 1.5mx1.5m a n d d e p t h a s instructed by Railway representative at site, for coiling the cables i n rea r o f relay rooms/ AFTC huts, apparatus c a s e s e t c . T h e work includes coiling t h e underground cables a n d placing closely o n e layer o f country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor].
650.00 Horizontal Drilling at approximately depth of 1.5 to 2m below the formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables etc. (Note: The pilot used for HDD should be of sufficient size to suit insertion o f HDPE /DWC pipe o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm dia HDPE pipe o r any other combination a s d i r e c t e d b y t h e site engineer) ( Supply o f H D P E p i p e i s not covered in this schedule)"
100.00 concrete t o a width o f 0.5mtrs 0 . 3 mtrs using cutter machine without damaging the platform. And plastering the removed slabs after laying o f cables w i t h proper finishing. (required material should be supplied by the contractor).
6000.00 cable/Signalling cable inside permanently solid lubricated HDPE Pipe already laid. This work i n c l u d e s n e c e s s a r y duct integrity test for s o l i d lubricated HDPE p i p e . ( This includes Transportation of materials from nominated stores to site)
15.00 as per R D S O Specifications No.RDSO/SPN/199/2010 Rev1.1 or latest DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
75.00 as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest
28.00 per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest
80.00 L E D a s p e r R D S O Specifications SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest
35.00 Calling on LED as per RDSO Specifications SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest
90.00 L E Da s p e r R D S O Specification SPECIFICATION N O . RDSO/SPN/153/2023 Revision 5.0 or latest
2.00 arrangement for Signals in RE area as per standard practice. The work comprises of providing MS angle frame and wire mesh in order to avoid close proximity of OHE wires. The work also includes provision of earthing wire using 4 S W G G I wires from the screening arrangement up to surface base as per t h e instructions o f Railway representative at site.[All materials required for this work shall be supplied by the Contractor].
28.00 d i a , 4 . 6 m / 3 . 6 m t a l l w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply o f colour light Signal pole 4.6m tall and 140 mm dia(Galvanised)
15.00 d i a , 4 . 6 m / 3 . 6 m t a l l w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply o f colour light Signal pole 3.6m tall and 140 mm dia (Galvanised)
45.00 pole 140mm dia with necessary inspection a s p e r specification/ drawing/ description enclosed in this document.
28.00 to suit C L S p o l e 4 . 6 m / 3 . 6 m t a l l , with necessary inspection a s p e r specification/ d r a w i n g / description e n c l o s e d i n this document. a)Supply o f l a d d e r with platform (4.6m) for CLS(Galvanised)
15.00 to suit C L S p o l e 4 . 6 m / 3 . 6 m t a l l , with necessary inspection a s p e r specification/ d r a w i n g / description e n c l o s e d i n this document. b)Supply o f l a d d e r with platform (3.6m) for CLS(Galvanised)
15.00 complete with hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document.
25.00 complete w ith surface base, signal pole, hood etc., with necessary inspection as per specification/ d r a w i n g / description enclosed in this document. DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
22.00 type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary inspection a s per specification/ drawing/ description enclosed in this document. a)Supply o f c o l o u r l i g h t S i g n a l u n i t (4 aspect)
10.00 type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary inspection a s per specification/ drawing/ description enclosed in this document. b)Supply of colour light Signal unit (3 aspect)
15.00 type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary inspection a s per specification/ drawing/ description enclosed in this document. c)Supply of colour light Signal unit (2 aspect)
6.00 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. a) Supply of Junction type route indicator - 1 way
10.00 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of Junction type route indicator - 2 way
2.00 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. c)Supply of Junction type route indicator - 3 way
28.00 light - complete with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Calling On Signal
15.00 made of cast iron with necessary inspection as p e r specification/ drawing/ description enclosed in this document. a)Supply of Off set bracket - large
15.00 made of cast iron with necessary inspection as p e r specification/ drawing/ description enclosed in this document. b)Supply of Off set bracket - small
5.00 w i t h n e c e s s a r y i n s p e c t i o n a s per s p e c i fi c a t i o n / d r a w i n g / description enclosed in this document. DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
2.00 facility of paging a n d talk-back including voice communication e q u i p m e n t with suitable switching arrangement a t the S i g n a l post and a t S M ' s r o o m a s per specification enclosed i n t h i s document. This includes drawl of tail cable through GI p i p e 25mm dia and 2 mtrs long duly clamped to Signal post w i t h b e n d as required a t site, termination of tail cable at one end in the apparatus case and other end in the console. In the SM's room, console shall be fixed on a table top. The w i r i n g s h a l l b e d o n e using wire PVC 16/0.2mm copper. [Talk-back equipment complete including housing box, wire PVC 16/0.20mm a n d all other miscellaneous materials required for the w ork shall be supplied by the Contractor].
100.00 Magnetically Latched Neutral Line 24V DC, 11F/4B contacts Relay complete with plug board (base plate), connectors and retaining clips and conforming to BRS 935A and RDSO Spn. No IRS S34 and S-23 or latest. The interlocking code for this unit shall be "ABDEG"
15.00 type Style 'QN1K' DC neutral line, 24V 1000 ohms 6F.6B contacts front contacts metal to carbon & back contacts metal to metal/carbon complete with plug board retaining clip and connectors conforming to BRS:930, IRS:S- 34 & IRS:S-23 and RDSO Spec. STS/E/Relays/UEA(PI) dt. 30.5.97 (Annexure-1) (as applicable). The interlocking code for this unit shall be BDEKX.
15.00 Style 'QNA1K', DC Neutral line, 24V, 1000 ohms 6F.6B, contacts, front contacts metal to carbon and back contacts metal to carbon, complete with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S60, IRS:S 34, IRS:S 23 & RDSO Spec.No. STS/ E/Relays/UEA (PI) dt.30.05.97 (Annexure-II) (as applicable). The interlocking code for this unit shall be CDEKY.
12.00 QBAT (2F/2B)(Miniature, Tractive armature, AC Immune, D . C Biased Track Relay) A.C. immunity level of 8 0 Volt A.C, c o i l nominal resistance o f 9 Ohms, confirming to BRS spec no. 939A & 966F2 a n d RDSO specification N o . 8 4 / 8 8 or latest. The interlocking code f o r this unit shall be "ABEJX"
15.00 Key Lock Checking Relay (KLCR) with one number K-50 neutral Relay to work on 24V DC non AC immunized as per specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt- 1 o r latest (with o n e extra ward plate and with case) contact configuration- 4F/4B and as per IRS:S-23, IRS:S@58"44@ IRS:46 or latest. DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
310.00 type , Style 'QN1',DC neutral line, 24V, 8F.8B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34& IRS:S 23 or latest. The interlocking code for this unit shall be ABDEF.
185.00 Style 'QNA1', DC Neutral line, 24V, 8F.8B contacts, front and back contacts metal to carbon, with plug board, retaining clip and connectors confirming to BRS:931A, IRS:S 60, IRS:S 34 and IRS:S 23 or latest. The interlocking code for this unit shall be ABDGH.
6.00 drg.No.S&T/ M F T / 2 9 1 w i t h scaffolding, POWDER COATED with stainless steel nuts and bolts for fixing t h e racks. Supporting angles, frame mounting triangle base with 'J' bolts and insulation of required numbers complete to suit QN1 / K-50 pre wired tag blocks with suitable inner frames. b) 2 way
10.00 (120/60 secs) with plug boards, connectors and retaining c l i p s w i t h necessary inspection as per specification/ drawing/ description enclosed in this document.
180.00 for a)LED a s p e c t s w i t h p l u g boards, connectors and retaining clips with necessary inspection as per specification/
120.00 relays with necessary inspection a s per specification/
1.00 354000.00 Kit suitable for testing all types of Relays
25.00 frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point contro l circuits, fixing o f p l u g boards, r e l a y s , r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F 5 , w i r i n g and termination as per a p p r o v e d circuit diagram and painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
13.00 frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point contro l circuits, fixing o f p l u g boards, r e l a y s , r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F 5 , w i r i n g and termination as per a p p r o v e d circuit diagram and painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. b)Wiring of Signal/ Point/ L C control circuit (up to 8 relays/plug in type)
3.00 frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point contro l circuits, fixing o f p l u g boards, r e l a y s , r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F 5 , w i r i n g and termination as per a p p r o v e d circuit diagram and painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. c)Wiring of Signal/ Point/ L C control circuit (up to 12 relays/plug in type) DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
6.00 frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit a n d Point contro l circuits, fixing o f p l u g boards, r e l a y s , r e s i s t o r s and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F 5 , w i r i n g and termination as per a p p r o v e d circuit diagram and painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts a n d nuts, p a i n t s , s o l d e r i n g materials, resistors, condensers a n d a l l other miscellaneous materials required f o r the work shall be supplied by the contractor]. d)Wiring of Signal/ Point/ L C control circuit (up to 20 relays/Plug in type)
95.00 boards, connectors and retaining clips with necessary inspection as per specification
105.00 boards, connectors and retaining clips with necessaryinspectiona s per specification/drawing/
6.00 with necessary i n s p e c t i o n , a s per specification/drawing
2.00 8 Nos of KLCRs
15.00 4 Nos of KLCRs
10.00 with scaffolding suitably concreting tri-pod bases using J-bolts, fixing rack supporting of size 50x50x6mm o n t o t h e wall. Reel insulators are to be provided for insulating t h e r a c k f r o m t h e scaffolding & tri-pod bases.(Payment b a s e d o n n u m b e r of equivalent 1way relay racks) (per Unit = Per 1way Relay Rack) DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
and e r e c t i o n o f cable Numbers termination r a c k 500/210/140 Terminals capacity o n teakwood base frame o f size 50mmx150mm of suitable length and width with rectangular slot in the centre for taking in the cables and painting as per standard practice.(Supply o f cable termination racks are not included in this schedule).[Foundation bolts and nuts with washers, cement, sand, stone jelly, teak w o o d base frame 50mmx150mm of suitable length and breadth, paint, varnish a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. a)Concreting and erection of cable termination rack 140/210 capacity
and e r e c t i o n o f cable Numbers termination r a c k 500/210/140 Terminals capacity o n teakwood base frame o f size 50mmx150mm of suitable length and width with rectangular slot in the centre for taking in the cables and painting as per standard practice.(Supply o f cable termination racks are not included in this schedule).[Foundation bolts and nuts with washers, cement, sand, stone jelly, teak w o o d base frame 50mmx150mm of suitable length and breadth, paint, varnish a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. b)Concreting and erection of cable termination rack -500 terminal capacity
2500.00 block, rubber grommets, clamping of cables using teakwood cable clamps and base planks, t e r m i n a t i o n o f cables, provision of ND t y p e f u s e s o f required capacities, provision of copper bus bar for supply terminals, w i r i n g , p r o v is io n of termination particulars d i a g r a m board u s i n g p l y w o o d of thickness 1 2 m m - t e a k w o o d fi n i s h o f size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic sheet of thickness 3 m m wherever required. The termination a n d c a b l e core particulars shall be painted on the PVC/ nylon sleeves. T h e w o r k a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly. (Supply o f P B T terminal blocks 2 5 m m & 60mm centers and PBT Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm f o r base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
550.00 block, rubber grommets, clamping of cables using teakwood cable clamps and base planks, t e r m i n a t i o n o f cables, provision of ND t y p e f u s e s o f required capacities, provision of copper bus bar for supply terminals, w i r i n g , p r o v is io n of termination particulars d i a g r a m board u s i n g p l y w o o d of thickness 1 2 m m - t e a k w o o d fi n i s h o f size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic sheet of thickness 3 m m wherever required. The termination a n d c a b l e core particulars shall be painted on the PVC/ nylon sleeves. T h e w o r k a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly. (Supply o f P B T terminal blocks 2 5 m m & 60mm centers and PBT Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm f o r base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. b)Termination u s i n g P B T f u s e b l o c k in cable termination rack (Per Unit = Per Fuse Block)
6.00 168/56 relay capacity using ' J ' type bolts a n d painting o f r e l a y r a c k a s p e r the instructions of Railway representative at site.(Supply of relay rack is not covered in this schedule).['J' type bolts and nuts with washers, nylon bushes, concreting m a t e r i a l s , p a i n t a n d all other miscellaneous materials required for the work shall be supplied by the Contractor]. a)Concreting and erection of relay rack - 168 capacity DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
15.00 blocks with 2 B A terminals, a n d wiring of relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Suitable wire supporting tray with cover made of PVC shall b e provided horizontally and vertically in the relay racks.. While running the wires on the aluminium ladder proper care shall be taken t o provide smooth materials like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes wiring o f contacts f o r data logger and terminating them i n t a g blocks, provision of relay index board.(Supply of relays, plug boards, connectors and retaining clips is n o t covered i n this schedule). [Wire PVC
terminals, h a r d w o o d p l a n k o f size
fi n i s h ,M Sa n g l e so f size 25mmX25mmX6mm, relay fixing bolts and nuts, teakwood plank 25mm thick for fixing resistors a n d condensers, phynolic sheet 6mm t h i c k o f size
grooved channel f r a m e f o r relay index b o a r d , p a i n t s , s o l d e r i n g materials, bunching thread, w ire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and a l l o t h e r miscellaneous materials required f o r t h e w ork shall be supplied by the Contractor].
30.00 terminal blocks a n d wiring o f additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall b e provided wherever required. Alterations t o Relay particulars shall be incorporated in the relay Index board.(Supply o f r e l a y s , p l u g boards, connectors and retaining clips and 50 way terminal boards i s n o t covered i n this schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 25mm thick for fixing r e s i s t o r s a n d condensers, soldering materials, bunching thread, wire wound resistance, c o n d e n s e r , wire supporting tray with cover of suitable size made o f PVC, paint, varnish and all other miscellaneousmaterials required f o r the work shall be supplied by the Contractor ]
45.00 relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm coppe r. T h e work includes painting alterations and releasing the unwanted w i r e s c a r e f u lly without disturbing the existing wiring.[Wire PVC 16/0.2mm c o p p e r , soldering materials, bunching threads, condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required for t h e w o r k s h a l l b e s u p p l i e d by the Contractor]. DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
1.00 147833.50 relay racks, cable termination racks, SM's control panel, battery room, power room, termination and wiring. The work involves laying of underground cables in the duct as well as with clamping arrangements on the walls, supply and fixing of aluminium ladders and supports with 3mm thick phynolic sheet for running t h e cables in t h e relay room. Interconnection shall be carried out with signaling multi core cable (skinned/ unskinned) and power cables as p e r the instructions of Railway representative at site. The w o r k also include termination of the interconnection cables o n 5 0 w a y terminals in t h e relay rack/ control panel, cable termination rack etc. After the interconnection cables are laid, the ducts shall b e filled with M sand and closed. Wherever required the cables shall be taken to o t h e r fl o o r s i n the building b y clamping them on MS angles and flats grouted on the walls.(Supply of interconnection cables i s not included in this schedule).[2BA terminals, Aluminium ladder arrangements using 37mmx37mmx5mm aluminium angles and 25mmx6mm aluminium fl a t s , aluminium supports, phynolic sheet - 3 m m thick for bottom of aluminium ladders, M S angles a n d flats, bolts and nuts, concreting materials, and all other materials required f o r t h e w o r k shall be supplied by the contractor]. b)Provision o f interconnection - more than 5 roads (same floor)
1.00 175746.30 relay racks, cable termination racks, SM's control panel, battery room, power room, termination and wiring. The work involves laying of underground cables in the duct as well as with clamping arrangements on the walls, supply and fixing of aluminium ladders and supports with 3mm thick phynolic sheet for running t h e cables in t h e relay room. Interconnection shall be carried out with signaling multi core cable (skinned/ unskinned) and power cables as p e r the instructions of Railway representative at site. The w o r k also include termination of the interconnection cables o n 5 0 w a y terminals in t h e relay rack/ control panel, cable termination rack etc. After the interconnection cables are laid, the ducts shall b e filled with M sand and closed. Wherever required the cables shall be taken to o t h e r fl o o r s i n the building b y clamping them on MS angles and flats grouted on the walls.(Supply of interconnection cables i s not included in this schedule).[2BA terminals, Aluminium ladder arrangements using 37mmx37mmx5mm aluminium angles and 25mmx6mm aluminium fl a t s , aluminium supports, phynolic sheet - 3 m m thick for bottom of aluminium ladders, M S angles a n d flats, bolts and nuts, concreting materials, and all other materials required f o r t h e w o r k shall be supplied by the contractor]. c)Provision of interconnections -more than 5 roads (different floors) DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
2.00 708081.12 Highly sensitive smoke aspiration system for Monitoring o f rooms a n d equipment's for earliest possible fi r e detection For Relay rooms a s p e r R D S O spec No.RDSO/SPN/217/2021 Ver.3.0 or latest.
2.00 311682.08 Fire Alarm system w ith loo p capacity of connecting maximum 50 devices. The panel shall have a built i n power supply and battery c h a r g e r R D S O Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest.
36.00 Optical/ Thermal a s p e r RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
2.00 manual call point with back box (RED) as per RDSO specification No.RDSO/SPN/217/2021 Ver.3.0 or latest.
2.00 to 92 d b A a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
8.00 m o d u l e a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
1.00 m o d u l e a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
2.00 generation & routing in case of Fire Alarm to concerned p e r s o n s a s p e r RDSO No.RDSO/SPN/217/2021 Ver.3.0 or latest.
350.00 unarmoured cable a s per RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest.
100.00 No.RDSO/SPN/217/2021 Ver.3.0 or latest.
2.00 155660.60 No.RDSO/SPN/217/2021 Ver.3.0 or latest.
2.00 CPVC Pipes with a l l required accessories for Aspiration system)
4.00 Stainless Steel preventive device with UL approved c l e a n g a s w i t h A u t o manual Reverse Stainless Steel valve 'NASA 400 MAR' or similar having capacity of 4kg, and made of stainless steel 304 grade with Indian Railway logo put on each unit.
2.00 103181.84 UL approved having capacity of 10kgs made of SS 304 grade with Indian Railway logo put on each unit and clean gas shelf life with 10 years warranty for leakage. Note: Warranty of OEM and Test certificates of any NABL approval L A B for clean gas along with the offer.
2.00 specification No.RDSO/SPN/217/2021 Ver.3.0 or latest.
2.00 for interfacing t h e F i r e A l a r m and Detection systems DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
1.00 521517.86 and commissioning o f remote monitoring software along with license for 9 9 control p a n e l s a s p e r No.RDSO/SPN/217/2021 Ver.3.0 or latest.. This includes necessary gateway card and network interface card for the system fully functional a s desired by railways. (software suitable for 8 stations)
1.00 charges o f fi r e a l a r m s y s t e m including programming of devices and fire alarm panel
1.00 C o m m i s s i o n i n g o f A s p i r a t i o n smoke detection
2.00 as per Technical specification
2.00 Meter, as per Technical specification
1.00 307856.22 accessories f o r 1310/1550nm w i t h all standard accessories as per TEC specification GR/OTD-02/02 J a n 2 0 0 5 or latest, ( this item should have valid TEC approval certificate) as per Technical specification
1.00 50V-500V/1000 mega ohm battery operated with all complete accessories, as per Technical specification
1.00 578788.99 Technical specification
1.00 186694.53 per Technical specification
1.00 per Technical specification
1.00 313043.90 Technical specification
1.00 Technical specification
1.00 Technical specification
1.00 w i t h a c c e s s o r i e s a s p e r Technical specification
1.00 accessories, as per Technical specification
1.00 specification
2.00 specification
1000.00 103.5mm inner d i a & 120mm outer dia c o n f o r m i n g t o s p e c i fi c a t i o n N o . IS 14930(Part 2): 2001 with o n e coupler for e v e r y 6 m o f p i p e a s p e r Technical specification
25.00 thick as per Technical specification
500.00 thick as per Technical specification DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
1000.00 (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters as per specification No. IS 4984: 2016 with latest amendments and Material Grade:PE 80
1000.00 colour Orange, width o f 250mm (10") by p r i n t i n g w i t h b l a c k l e t t e r s 'Indian RailwaySignal/Telecom/OFC Cable' on both sides
210.00 3M make o r similar, Model: R FID (1421) and installation, c a b l e d e t e c t i o n of capacity to detect the cable upto 5 feet depth.
7000.00 mm (inner dia) with couplers
2.00 mountable 2 4 Fibre management system ( F M S ) c o n f o r m i n g t o RDSO/SPN/TC- 37/2000(rev-3 amdt-1 o r latest similar to COMMSCOPE make o r better, suitable for splicing and front patching 24F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of 4 nos of Patch cords of required length ( A l l other materials required for splicing are to be supplied by contractor )
15.00 mountable 4 8 Fibre management system ( F M S ) c o n f o r m i n g t o RDSO/SPN/TC- 37/2000(rev-3 amdt-1 o r latest similar to COMMSCOPE make o r better, suitable for splicing and front patching 48F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of Wooden Plank, L clamps and 4 nos o f Pa t c h c o r d s of r e q u i r e d l e n g t h (All other materials required for splicing are to be supplied by contractor)
4.00 s i z e 6 0 0 m m x 6 0 0 m m w i t h complete accessories
6.00 mountable type 19 inch 12U network Rack with front glass doo r w ith loc k a n d rack fi x i n g multipoint A C P o w e r t r i p & all accessories (Power extension board with one set of MCB, exhaust fan, cable manager)
1.00 Racks of size 1950mm x600mm x 600mm or higher (Make: HCL/ Vero/President/ Rittal/ Puncom or better) complete with all fittings including DC Fans (24V/48V)-2nos, separator sheet/ plate to keep testing equipment-1no and AC power distribution panel ( Horizontal fitting) with power sockets and fuse protection ( min 6 nos of 230V - 15/5A combined and other accessories
20.00 machine DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
160.00 type with 4 terminals and stumps with necessary inspection a s per specification/ drawing/ description enclosed in this document.
3000.00 centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre.
1000.00 centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre.
320.00 centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse
20.00 quarter size) to suit Southern Railway standard with necessary inspection a s per specification/ drawing/ description enclosed i n this document a)Supply of apparatus case - Full size
10.00 quarter size) to suit Southern Railway standard with necessary inspection a s per specification/ drawing/ description enclosed i n this document b)Supply of apparatus case - Half size
2.00 diagram board in the station master's room. The board shall be made of Phynolic synthetic industrial fibre base fi n e weave cotton fibre board (matt finish) 6mm thick size 1800mm X 1200mm with aluminium channel frame. T h e yard layout shall be neatly painted and fixed a s instructed by Railway representative at site.[All materials required for the work shall be supplied by the Contractor]. DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
2.00 box of size 1000X750X100mm made of 25mm thick teak wood persplex sheet fronted 6mm (Colourless) fixed on the wall at a convenient location as instructed by Railway representative at site. The board should have provision of pad lock and locking arrangements and shall be equipped with the following tools[reputed make]: a. Digital Mulltimeter similar to Model No. Rish Multi 18S with suitable carrying case and test probes. b. Centre zero ammeter 30-0-30 Amps - 1 No. c. Screw drivers of different types and sizes with common handle - 1 set d. Spanner double ended 33mm - 1 No. e. Spanners double ended 3/8x1/2" - 1 No. f. Spanners double ended 5/8x3/4" - 1 No. g. Spanners double ended 7/8x1" - 1 No. h. Hammer 1 1/2 lbs ball pane - 1 No. i. Hacksaw frame - 1 No. j. Adjustable screw spanner 12" - 1 No. k. Insulated cutting pliers- 1 No. l. Insulated nose plier- 1 No. m. Electric soldering iron 230V 60W Soldron/Philips make - 1 No. n. Electric soldering iron 110V 35W Soldron/Philips make - 1 No. o. Megger 500V/ 500Mohms. with Probe- 1 N o . The above tools shall be purchased from Reputed manufacturers only in consultation with the Railway representative at site.[Teak wood tool box made of 25mm teak wood plank, perspex s h e e t , a l l t h e tools mentioned above, padlock a n d other miscellaneous items shall be supplied by the Contractor].
2.00 and supply of Ni-cad power pack 4V-2.2AH with charger to work on 110VAC
1.00 fronted b o x o f size 300mm x 600mm x 75mm with hooks to keep various keys with description engraved on the tags. [TW Glass fronted box of size 300mmx600mmx 75mm with built in lock, hooks, engraved tags and all other miscellaneous materials required for the work shall be supplied by the Contractor].
10.00 cable(per unit=100 mtrs) APC)
300.00 (Per unit=Per fuse)
280.00 less than 6mm thick and with an Foot insulation to withstand 650VAC, o n the fl o o r o f relay room e t c a t p l a c e s as indicated b y railway representative at site."
1.00 of 1TB capacity. DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
8.00 termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe f o r cable entry a n d o n e G I pipe 150mm long 32mm dia for drawl of jumper wires f o r Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside a n d outside with o n e coa t of red- oxide and two coats of aluminium paints.
40.00 machine-IRS t y p e a n d connecting all ground connections including wiring and termination in p o i n t m a c h i n e and interconnections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision of insulation to stretcher bars, throw bar lug a n d "D" bracket w h e r e v e r required, cutting of notches on the point machines covers to suit crank handle configuration. (Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required f o r t h e w o r k s h a l l b e supplied by the Contractor].
post (paging and talk back)
100.00 foundations for a width of 0.5m on all sides, up t o a l e v e l 1 5 0 m m b e l o w the foundation top. T h i s w o r k includes consolidation of earth by watering and ramming.The earth shall b e taken from Railway premises as instructed by Railway representative at site.
25.00 foundation as per Drg.No.SG/CN/02/9 using metallic templates, f o r erection of colour light signals up to 4 aspects. [Foundation bolts, cement, M sand, stone jelly o f size 20/25mm d i a a n d a l l other miscellaneous materials required f o r the work shall be supplied by the Contractor]. DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
25.00 mounting o f colour light signal u p t o 4 aspects complete o n Signal pole/ Off-set bracket, ( f o r L E D / filament b u l b s ) with lenses, triple p o l e l a m p holder, filament switching units, C L S transformer, current regulators (whichever is applicable), fixing of ladder w i t h platform complete and concreting of ladder shoe, fixing of number plates, marker board, lens guard, fixing of s p e e d l i m i t b o a r d wherever necessary, termination o f tail cables, wiring o f signal u n i t w i t h P V C w i r e 3/0.75mm copper, provision of EWS locks, and painting of one coat o f r e d oxide a n d t w o coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through b o l t shall be provided by drilling a hole i n t h e signal pole t o prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, C L S aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, current regulators, lamp holders, lamps, filament switching unit and CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia , M sand, Signal Collar Rings, wire P V C 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead wool, paints PVC/Nylon sleeves, enameled number plates. enameled marker boards, E W S locks, a n d a l l other miscellaneous materials for the work shall be supplied by the Contractor]."
23.00 foundation a s p e r D r g , No.SG/CN/02/10 using metallic templates, f o r erection of g r o u n d t y p e c o l o u r l i g h t s h u n t signal. [Foundation bolts and nuts, cement, M sand, stone jelly o f size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor]."
28.00 complete including surface base, signal pole, LED aspects/ l e n s e s , b u l b s with holders (whichever is applicable), fixing of lens guards, number plate, termination of tail cables, wiring o f signal unit with PVC wire 3/0.75mm copper, provision o f EWS locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint. ( S u p p l y o f G r o u n d t y p e s h u n t signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered i n t h i s schedule). [Wire PVC 3/0.75mm copper, lens guards, EWS locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall b e supplied by the Contractor]." DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
35.00 and nuts, erection o f P o s t t y p e shunt Signals, termination o f t a i l c a b l e s and wiring using wire P V C 3/0.75mm copper, provision of EWS lock and painting o f one c o a t o f red-"oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes o n the CLS post and provision o f a through bolt with nut to prevent the Off-setbracket from slipping down."
6.00 w a y t o 6 w a y s - complete/ fi x i n g of additional l i m b t o t h e e x i s t i n g route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply o f junction t y p e Ro u t e Indicators - complete and additional limb is not covered in this schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, w i r e mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing and wiring of direction type route indicator - 1 way
10.00 w a y t o 6 w a y s - complete/ fi x i n g of additional l i m b t o t h e e x i s t i n g route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply o f junction t y p e Ro u t e Indicators - complete and additional limb is not covered in this schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, w i r e mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].b)Fixing a n d wiring of direction type route indicator - 2 way
2.00 w a y t o 6 w a y s - complete/ fi x i n g of additional l i m b t o t h e e x i s t i n g route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply o f junction t y p e Ro u t e Indicators - complete and additional limb is not covered in this schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, w i r e mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].c)Fixing a n d wiring of direction type route indicator - 3 way DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
28.00 and nuts, erection of Calling On Signals/ 'A' marker lights, termination of tail cables and wiring u s i n g w i r e P V C 3/0.75mm copper, provision o f E W S l o c k , number plates/ marker boards a n d painting. The work also includes drilling suitable holes on t h e CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down.(Supply of Calling o n Signal/ ' A ' marker light, LED aspects/holders & b u l b s a n d Off set brackets is not covered in this schedule). ['U' bolts and nuts, through bolts with nut, w i r e P V C 3/0.75mm copper, E W S lock, Enameled n u m b e r p l a t e s , w i r e mesh, PVC/Nylon sleeves, paints a n d a l l other miscellaneous materials shall be supplied by the contractor].
5.00 o f new tail cables for colour light signals up to four aspects with o r without route indicator, post type shunt signal and Calling on signals, termination o f new tail cables and w i r i n g u s i n g w i r e PVC 3/0.75mm copper. This work includes drawl of new tail cables into the signal post duly releasing the existing tail cables from the relevant signals and re-surfacing t h e e a r t h excavated as instructed by Railway representative at site. [Wire PVC 3/0.75mm copper, paints and all other miscellaneous materials shall be supplied by the Contractor].
5.00 new CLS units with LED aspects/ lamps, holders etc., up to four aspects, directly or using off set brackets duly drilling holes on the signal poles, provision of EWS locks wherever necessary, termination o f tail c a b l e s and wiring using wire PVC3/0.75mm copper and painting of aspect. The new tail cables shall be taken through the signal poles and the unwanted cables duly released"
5.00 m asonry platform a s p e r draw ing No. SG/CN/02/12 w i t h country bricks o f size 220mmx 100mmx60mm (app) at the foot o f s i g n a l p o s t telephones a s p e r the instructions of Railway representative at site.[Country bricks of size 220mmx100mmx60mm (app), cement, M sand and all other miscellaneous materials required for the work shall be supplied by the Contractor]. DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
300.00 ladder (4.6m tall, 140 mm dia /3.60 m tall,140 m m dia), clamps, point roddings and other materials related t o Signalling. Minimum DF thickness shall be 80 microns. Transportation o f materials from site/stores to galvanization workshop and b a c k to site/stores n o t included i n this schedule.Transportation charges will be as per "relevant S O R s c h e d u l e s . Test certificate showing t h e D F T , t y p e of galvanization, materials used etc., from galvanizing firm for each batch to be submitted.(Unit is calculated based on the w e i g h t of the Signal poles, ladders, clamps, rodding's etc.,)"
96.00 circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un- charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone) DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
22.00 circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un- charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). b)Provision of track circuit in RE/Non RE area (other than point zone)
10.00 suit RE/Non R E standard a s per approved s i g n a l i n g p l a n . T h i s w o r k includes provision of double bonding a n d parallel jumpers, provision o f b o n d w i r e clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration to existing track circuits at feed end
10.00 suit RE/Non R E standard a s per approved s i g n a l i n g p l a n . T h i s w o r k includes provision of double bonding a n d parallel jumpers, provision o f b o n d w i r e clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sq.mm cable b)Alteration to existing track circuits at relay end DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
42.00 foundation and erection of apparatus case full size a s p e r D r g . No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door a n d another f o r t h e back door, fixing o f one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, ' E ' t y p e locks, cement, M s a n d , s t o n e j e l l y o f s i z e 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts a n d a l l other miscellaneous m a t e r i a l s r e q u i r e d for thework shall be supplied by the Contractor.]
25.00 foundation and erection of apparatus case half size as per Drg, No.SG/CN/02/7, fixing o n e ' E ' type loc k f o r t h e front doo r and latching arrangement for the back door, and fixing o f o n e hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts a n d a l l other miscellaneous materials required f o r t h e w ork shall be supplied by the Contractor]"""
2.00 termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each p i p e f o r cable throughing, fi x i n g of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside a n d outside with o n e coa t of red- oxide and two coats o f aluminium paints. (Supply of CT boxes is not covered i n this schedule. Rails of different length shall be supplied by Railways. The contractor shall cut lengthy rails wherever required.) [Cement, M s a n d , s t o n e j e l l y o f size 20/25mm, paint, varnish, G I Pipes 32mm dia with clamp nuts - 12mm thick - 2 Nos. f o r each pipe, fixing bolts a n d nuts with washers, E W S locks, paints a n d a l l other miscellaneous materials shall be supplied by the Contractor]. DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
3.00 existing location b o x e s v e r y carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement a s instructed by t h e Railway representative a t s i t e . The work includes ensuring the safety of the signaling system, releasing the cable coils t o g i v e a c c e s s for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes t o the required level shall be done as instructed by the Railway representative at site. If the existing earth connections t o t h e location boxes are disturbed, the earth wires shall be properly re-connected. b) Shifting of apparatus case (half)
1000.00 existing terminals/ fuse blocks in apparatus cases/ battery boxes/ CT boxes/ cable termination racks a s p e r approved circuit diagram. T h e terminal particulars a r e to be repainted /corrected o n the doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing t h e opening created f o r entry of n e w cables i n the apparatus cases with m a s o n r y b r i c k work and s e a l i n g the b o t t o m o f t h e apparatus cases/ cable termination racks w i t h cable compound. [Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials shall b e supplied by the contractor].(Per Unit = Per Terminal block)
4000.00 p o w e r c a b l e s a n d i n t e r n a l w i r i n g on terminal/ f u s e blocks i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each a p p a r a t u s case, varnishing all teakwood items, fi x i n g of terminals/ fuse blocks o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, the side openings o f apparatus case foundation s h a l l be closed with brick work, cement plastered, the inter-space filled with M sand u p to base level and the bottom surface shall be sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n this schedule)." a)Termination on 25/60mm PBT terminals (new location) (Phynolic sheet)(Per Unit = Per Terminal block) DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
650.00 p o w e r c a b l e s a n d i n t e r n a l w i r i n g on terminal/ f u s e blocks i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each a p p a r a t u s case, varnishing all teakwood items, fi x i n g of terminals/ fuse blocks o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as p e r approved circuit d i a g r a m a n d cable plan, p a i n t i n g of particulars on sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, the side openings o f apparatus case foundation s h a l l be closed with brick work, cement plastered, the inter-space filled with M sand u p to base level and the bottom surface shall be sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n this schedule)." b)Termination on PBT fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block)
500.00 power cables and internal wiring b y fixing additional terminals/ f u s e blocks o n the existing terminal boards of apparatus cases, cable termination boxes e t c . The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing t e r m i n a l boards, drilling o f necessary h o l e s , termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. A f t e r terminations are over, the s i d e o p e n i n g s o f a p p a r a t u s case foundation shall be closed with brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d the bottom surface s h a l l b e s e a l e d with sealing compound. a)Termination of c a b l e s o n 2 5 / 6 0 m m PBT terminals (existing location)(Per Unit = Per Terminal block) DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
100.00 power cables and internal wiring b y fixing additional terminals/ f u s e blocks o n the existing terminal boards of apparatus cases, cable termination boxes e t c . The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing t e r m i n a l boards, drilling o f necessary h o l e s , termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. A f t e r terminations are over, the s i d e o p e n i n g s o f a p p a r a t u s case foundation shall be closed with brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d the bottom surface s h a l l b e s e a l e d with sealing compound. b)Termination of c a b l e s o n P B T f u s e block (existing location)(Per Unit = Per Fuse block)
60.00 cells of t h e f o l l o w i n g capacities, on existing battery stand/ RC C slabs i n the battery room. The work involves charging of secondary cells, fixing a n d connecting the batteries with strips, manufacture and fixing of t e a k w o o d t e r m i n a l box, termination of cables, wiring with suitable wire PVC 7/1.40mm and 3/0.75mm copper through suitable PVC pipes/ casing properly clamped, provision o f battery particulars board made of phynolic sheet 6mm thick of size 900mm x 1200mm with Aluminium grooved channel frame i n the r e l a y r o o m . T h e particulars shall be digitally u s i n g good quality "laminated gum sheet, provision of hydrometer -1 No. o n a s t a n d a n d battery tester-1 No. Charging of secondary cells shall b e done b y t h e c o n t r a c t o r through reputed agencies.(Supply of secondary cells is not covered in this schedule). [Teakwood p l a n k 2 5 m m t h i c k for manufacturing termination box with locking facility, wire PVC 7/1.4mm and 3/0.75mm copper, anti- corrosive paint, varnish, PVC pipes/ casing, a n d a l l o t h e r miscellaneous materials required for this work shall be supplied by the contractor]." b)Installation o f 2V- 200AH c e l l o n existing stand/ slabs(Per Unit = Per Cell) DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
15.00 cells of t h e f o l l o w i n g capacities, on existing battery stand/ RC C slabs i n the battery room. The work involves charging of secondary cells, fixing a n d connecting the batteries with strips, manufacture and fixing of t e a k w o o d t e r m i n a l box, termination of cables, wiring with suitable wire PVC 7/1.40mm and 3/0.75mm copper through suitable PVC pipes/ casing properly clamped, provision o f battery particulars board made of phynolic sheet 6mm thick of size 900mm x 1200mm with Aluminium grooved channel frame i n the r e l a y r o o m . T h e particulars shall be digitally u s i n g good quality "laminated gum sheet, provision of hydrometer -1 No. o n a s t a n d a n d battery tester-1 No. Charging of secondary cells shall b e done b y t h e c o n t r a c t o r through reputed agencies.(Supply of secondary cells is not covered in this schedule). [Teakwood p l a n k 2 5 m m t h i c k for manufacturing termination box with locking facility, wire PVC 7/1.4mm and 3/0.75mm copper, anti- corrosive paint, varnish, PVC pipes/ casing, a n d a l l o t h e r miscellaneous materials required for this work shall be supplied by the contractor]." d) Installation o f 2V- 40/80AH cell o n existing stand/ slabs(Per Unit = Per Cell)
2.00 Non-Interlocked working of Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site.(Supply of relay rack, relays, and SM slide instrument is not included in this schedule).[All other miscellaneous materials required for the work shall be supplied by the Contractor].
4.00 t e le p h o n e communication a t stations/ tents as p e r t h e instructions o f Railway representative at site. The PA system and magneto telephones will be returned to the contractor after t h e completion o f NI working. Signalling cables available may be used for the communication.(Hiring of P A s y s t e m equipments and magneto t e l e p h o n e s s h a l l b e d o n e b y the C o n t r a c t o r ) [ A l l o t h e r miscellaneous materials required for t h e w ork shall be supplied by the Contractor]. (Per Unit= Per set per day) DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
1.00 required by Railways, wiring it as per circuit diagram and painting of particulars. The work includes connecting 1 No. of magneto telephone with Ni-cad power pack 4V-2.2AH with charger t o w o r k on 110VAC and connecting the annunciator to t h e different telephone c i r c u i t s . The particulars o f the circuits a n d t h e ringing codes shall be painted on the top of the annunciator box.(Supply of annunciator is not included in this schedule)."[Magneto telephone handle type w ith Nicad power pac k 4V-2.2AH w ith charger t o work on 110VAC, wire PVC 16/0.2mm copper, paint a n d a l l o t h e r miscellaneous materials required for the work shall be supplied by the Contractor]."
5.00 Nicad pack
15.00 and painting of boards with 'LEGEND' such as "Draw close if signal is at on" at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this schedule. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, M sand, cement, M.S.flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor].
2500.00 Crossing/Road Cutting/Trenches
5.00 termination r a c k s a l o n g w i t h a l l the terminals, fuse blocks, relays, with jacks, holding clips etc., 50 way boards, terminals, connecting wires, cables etc., carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. After releasing, the fl o o r s h a l l b e l e v e l l e d and cement plastered"
5.00 different types including tail cables, carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site.
6.00 STOP board/Warning board/ LEGEND boards along with rails, accounting and stacking them neatly a t a p l a c e as instructed b y Railway representative at site. Also the resultant pits shall b e re- surfaced a n d consolidating by ramming and levelling" DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
10.00 facing point lock,split stretchers, electrical detector, l o c k bars, point/trap indicators c r a n k s , r o d s e t c . , carefully without Damaging the materials, accounting and stacking t h e m n e a t l y a t a place as instructed by Railway representative at site.
200.00 available in the path of cable trench (Above the ground)
30.00 available in the path of cable trench (buried inside ground)
25.00 Half/ Quarter size) without damage after releasing the s h e l f p l a n k s , Terminal b l o c k s , F u s e B l o c k s , Te r m i n a l Boards, Relays of all types EKTs, Secondary Cells, power equipments, 'E' type locks, etc., and breaking t h e concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stacked a t a p l a c e as instructed by Railway representative at site.
10.00 existing c a b l e termination b o x e s , after releasing the base plank, Terminal blocks, Fu s e Blocks, Terminal Boards, c u t rails, pipes, etc., closing t h e resultant pits and consolidating it by ramming and levelling. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site.
10.00 Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking t h e concrete foundation,closing t h e resultant p i t and resurfacing it by ramming and levelling.
15.00 machines ( a l l t y p e s ) including ground c o n n e c t i o n s a n d o t h e r accessories available complete without any damage to the gadgets, accounting a n d stacking them neatly a t a place a s instructed by Railway representative at site.
10.00 signals along with surface base, signal post etc carefully without a n y damage, accounting and stacking them neatly a t a placea s instructed b y Railway representative a t s i t e . T h e w o r k also includes breaking and removal of concrete foundation and refilling of the resultant pit by ramming and levelling." DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
120.00 stumps and terminals after releasing all t h e bond wires. T h e released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site.
6.00 Cable Route Plan
6.00 staff round the clock to attend the teething trouble of the installation along with SSE/JE after t h e installation h a s been brought into commissioning. T h e work i n c l u d e s routine maintenance, failure restoration a s p e r the direction of the SSE/JE
150.00 oriented technical manpower t o carryout Days works like Drawing, computation, writeup etc., using computer, using software like AUTOCAD, MS Office etc., for 08.00 hrs in a day with all expenses of transportation, accommodation, food, consumables etc., w ith a l l ascents, descents, taxes, octroi, cess, fees, duties, duties with contractors c o s t e t c . , a s per special conditions/ specifications/ regulations and as directed by Engineer-in-charge. Note: The person engaged for providing the services shall be c o n v e r g e n t w i t h computer working knowledge in above software.
210.00 S & T gears by deputation of Days Helpers/Unskilled Labour for executing additional S & T portion o f t h e works. The w o r k can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative.
90.00 S & Tg e a r sb y d e p u t a t i o n of Days Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer (Skilled Labour or Technician ) etc., for executing additional S&T portion of works. The work can involve fixing, releasing, dismantling, replacement, painting or alteration of v a r i o u s s i g n a l l i l n g assets or parts, termination of cables, minor patch work on damages at location box, Plastering, Concreting brick work, wiring alterations, c a b l e jointing e t c a s p e r instruction of Railway representatives at size.
1100.00 r o a d a s p e r t h e instructions o f Railway representative a t s i t e . T h e w o r k also includes loading a n d unloading o f the materials a)Transportation o f Signalling materials upto 100kms
500.00 more than 100km DY.CSTE-CN-TBM-S AND T/SOUTHERN RLY
110.00 or other machineries for regarding and levelling the formation, dismantling any infringing structures, c l e a r i n g and removing debris etc., w ith a l l leads and l i f t s e t c . , complete and a s p e r the instruction o f Railway representative at site. Total 76042167.70
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022.pdf
ATTACHMENT
ACSno_1_1.pdf
ATTACHMENT
ACSNo_2.pdf
ATTACHMENT
ACSNo_3.pdf
ATTACHMENT
ACSNo_4.pdf
ATTACHMENT
ACSNo_5.pdf
ATTACHMENT
ACSNo_6.pdf
ATTACHMENT
ACSNo_7.pdf
ATTACHMENT
ACSNo_8.pdf
ATTACHMENT
ACSNo_9.pdf
ATTACHMENT
ACSNo_10.pdf
ATTACHMENT
ACSlipNo_11.pdf
ATTACHMENT
SOR2022.pdf
ATTACHMENT
jpo_ann_to_cir_17-2013_1.pdf
ATTACHMENT
JTJESPMASTERPLAN_APPROVED.pdf JTJ VB Approved ESP
ATTACHMENT
JTJESPBYPASS-Alt-1.pdf
ATTACHMENT
JTJ-SIP-TENTATIVEPLAN.pdf
ATTACHMENT
JTJ-TenderDoc_1.pdf
ATTACHMENT
JTJESPMASTERPLAN_APPROVED.pdf
ATTACHMENT
Download all tender documents and submit your bid