Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 97 19 JWALA HERI PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | Admitted-Finance |
| 4 | Not Admitted-Finance | Not Admitted-Finance Price Bid not complied |
| 5 | Not Admitted-Finance | Not Admitted-Finance Price Bid not complied |
Tender Value
₹39.8 L
EMD Value
₹80,000
Closing Date
6 Jan 2020, 2:00 pmClosed
HEAD W S Div NPL
HEAD W S Div NPL
Renovation of Force Hardness metrology lab at NPL campus-S.I.T.C. of Precision AC Plant including CAMC
2019_CSIR_39052_1
04/0162/2018-WS-AC
Open Tender
Electrical Works
Item Rate
90 days
CSIR-NPL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Director NPL
₹80,000
28 Jan 2020
27 Dec 2019
7 Jan 2020
28 Dec 2019
6 Jan 2020
28 Dec 2019
Amount
Part-A (S.I.T.C of Air-conditioning work) ITEM NO. 1 Supply, installation, Testing and commissioning of Highly precision microprocessor based controlled floor mounted (as per scope of work enclosed) top discharge air-conditioner comprising of energy efficient stepless variable capacity scroll compressor with heater, humidifier, copper air cooled air conditioning unit with Green gas refregent , variable speed composite material EC fan with fanspeed controller including gas charging, pressure testing, leakage testing, vaccumizing, dehydration including suitable size & length drain pipe, 18 SWG hard copper piping up to 10 mtrs between indore unit and outside condensing unit, electrical cabling etc, including painting, clamping the piping, angle iron stands, suitable control cable for indoor and out door unit, as per specification (mention in scope of work) and maintaining required temperature 23 °C ± 1 °C and RH-50 ± 10%. and providing & fixing of sensor with display box in each A.c. room for recording & display of AC parameter like Humidity & Temp., Including necessary required foundation (angle iron stand/ cement concrete) for complete installation of new precision A/c plant, make (Blue box/ Vertive (Formly known as Emerson)/ Hirros/ schneider/ Stulz./ Danco Happel)
5 TR capacity
10 TR capacity (9 to 10 TR capacity as per manufacturar guideline)
ITEM no. 2 supply and fixing of Hard copper refrigerant piping including nitrile rubber insulation on suction line. etc as per site requirement. 10 TR capacity-11/8" & 7/8"
ITEM no. 3 Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. G.I. Ducting 22 Gauge (Thickness 0.80 mm sheet )
ITEM No. 4 supply and installation of flexible fire proof double layred cloath connections with G.I. frame nut bolts,screws etc.between each package unit and plenum as per site requirement.
ITEM No. 5 Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct inside after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 9 MM
ITEM No. 6 supplying & fixing of powder coated extruded aluminium supply AIR grills/diffuser with aluminium volume control dampers as per specification.
ITEM No. 7 Supply,installation,testing and commissioning of GI /MS volume control duct damper complete with neoprene rubber gaskets,nuts,bolts,screws linkages,flanges etc.,as per specifications.
ITEM No. 8 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
A Main incomer (i) 3 pole, 315 Amp, 35 kA, 415 volt, MCCB -- 01 B Outgoing (i) 3 pole, 100 Amp, 415 volt MCCB, ---03 nos
ITEM NO. 10 Finishing expose A/c duct/cabletray etc with Automotive paint( two or more coats) at all locations prepared and applied as per manufacturer's specifications by spraying including appropriate priming coat,preparation of surface,etc. complete as per directions of engineer-in-charge.
ITEM NO. 11 Buy back of old existing 3 nos. package A/c system with condenser & piping etc including its dismentaling & removing.
10 TR capacity
5 TR capacity
Part B (CAMC for newly installed ac plant (Five year) ITEM NO. 12 comprehensive maintenance contract for precision AC plant mentioned in item no.1 (A&B) including all parts and spares such as gas,electronic circuit, all filter repairing/ replacement of compressor,fan motor,fan belt,condensor fan motor.LED Display etc required for smooth functioning of Air conditioning plant comprising of all the machinery,equipment installed in the AC plant room ,after completion of 01 year warranty period for 5 years. CMC work will be awarded after completion of warranty period as the basis of quoted rates.Quote the rate year wise as follows: (Note:- One visit to be done per month, as per detail scope of work enclosed & at a time two no. newly installed 10TR capacity precision AC are running out of three no. newly installed precision AC, which are covered under CAMC.)
First year
10 TR capacity
5 TR capacity
Second year
10 TR capacity
5 TR capacity
Third year
10 TR capacity
5 TR capacity
Fourth year
10 TR capacity
5 TR capacity
Fifth year
10 TR capacity
5 TR capacity
Om Vaishnav Technocrates
Leo Air and Power Solution Pvt Ltd.,
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .