Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹25.4 L+₹17,157.50 (0.68%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹26.2 L+₹95,642.50 (3.79%)Rejected-Finance NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹28.8 L+₹3.5 L (13.9%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹33.9 L+₹8.7 L (34.5%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
25 Jan 2023, 6:00 pmClosed
GE MH AND RH KIRKEE
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Kirkee Pune 411003
REPAIRS TO WATER PROOFING TREATMENT TO ROOF REPAIRS TO SUNKEN FLOORS AND PLUMBING WORKS TO CERTAIN OTM ACCN AT MH AREA UNDER GE MH AND RH KIRKEE
2023_MES_573586_1
8349/E8
Open Tender
Civil Works
Item Rate
180 days
GE MH AND RH KIRKEE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KIRKEE
₹80,000
Yes
1 Mar 2023
7 Jan 2023
27 Jan 2023
7 Jan 2023
25 Jan 2023
13 Jan 2023
7 Jan 2023 - 18 Jan 2023
Amount
Taking down / removing existing water proofing treatment from RCC roof slab including removal of plaster bed below felt / membrane and removing the same outside the permiss all as directed.
M&L for providing water proofing plaster on slab average thickness 15mm in CM 1:3 mixing with liquid water proofing compound all as per manufactureres instructions, finished even and smooth without using extra cement all as specified and directed Note :- Liquid WPC shall be measured & paid seprately under relevant item of this BOQ.
Supply only liquid water proofing compound hydroseal-W+ or eqivalent (for plaster hardening, to contol efflorescence & fungal growth) as approved by GE.
M & L for applying APP (Atactic Poly Propylene) bitumen membrane 3mm thick APP modified weight not less than 3.60 Kg/Sqm reinforced with non woven polyester fibre of weight 160 gms/sqm as center core and without multiple layers of polyethylene, finished on top and bottom with 7 micron thick flammable polyethylene, applied by thermo fusion using LPG torch on the bottom portion of the membrane, after applying a coat of bituminous primer 0.40Kg/Sqm over roof ( An overlap of 100mm & 150mm shall be provided on sides and ends respectively ) complete all as per manufacturers instructions.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry in CM 1:3 complete all as specified and directed
Cutting out cracks to V-section in existing roofs or terracing, cleaning out, and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 ( by weight) complete all as specified and directed
M&L for Hydraulically pressed burnt clay tile plain of size 200x200x19/20mm machine made laid over & including cement mortar screed 20mm thick in CM 1:3 mixed with water proofing compound and jointed, pointed in neat cement slurry mixed with 5% crude oil by weight of cement.
Dismantling floor, hearth or wall tiling including cement mortar bedding/complete and removing rubbish off the premises complete all as specified and directed.
M&L Coloured Glazed ceramic tiles 300 x 200 x 7mm thick, on vertical surfaces such as skirting, dados etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 10mm thick rendering in CM 1:4 as backing coat complete all as specified and directed.
M&L non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.06 sqm but not exc 0.11 sqm in floor etc set and jointed in neat cement slurry to match the work using colour tiles over and including screed bed on bedding layer 15mm thick in CM 1:4 complete all as specified and directed.
M&L for 25 mm thick cement concrete M-15 grade (nominal mix) using 12.50mm graded stone aggregate as in floors complete all as specified and directed.
Demolition of cement concrete (un reinforced) any description in any position not otherwise described including removing the spoil off the premises complete all as specified.
M&L for water proofing treatment to RCC sunken slab complete all as specified & directed by Engineer-in-Charge. Make : Pidilte or equivalent approved make as approved by GE.
M&L for the tile joint chemical cleaning and re-grouting carefully by washing the existing tille with heavy duty tile cleaner preferbly of M/S Pidilite or equivalent cleaner, again washing with fresh jet water, scratching the joints and filling the same with (white/matching colour) epoxy tile grout of M/s Pidilite, ROFF RTM epoxy or equivalent, curing , cleaning the surface etc, complete all as directed by Engr-in-Charge and as per the sample done at ground level.
M&L for water proofing treatment of External walls, chhajjas DFT: 110 microns by applying two coats of elestromeric coating Raincoat, material covering capacity 3 Sqm per litre in 2 Coats without dilution over a coat of efflorescent resistant primer 10sqm/litre/coat after cleaning the surface throughly and sealing all cracks with acrylic sealing compound as per the manufacturers specifications and directions of Engr-in-Charge Make :- Raincoat of PlDlLlTE or equivalent.
S&F Plain 145 gsm fibreglass mesh and apply one coat of Acyrylic polymer modifed cementious slurry coating with "Dr Fixit Bathseal Plus or eqvt " by brush and cover it with 100 mm overlap both ways after necessary preparation of surface when it is still wet complete all as per manufacturers instructions. Apply second coat of the same coating on the angle fillets and allow it to dry completely and turned upto 150mm from FFL at Bath/Wc /Kitchen area's and all as per manufacturer specification all as specified and directed .
M&L for providing water proofing plaster at the junction of wall and slab at chajjas, lintels etc, of average thickness 20mm in CM 1:3 mixing with liquid water proofing compound all as per manufactureres instructions, finished even and smooth without using extra cement all as specified and directed Note :- Liquid WPC shall be measured & paid seprately under relevant item of this BOQ.
M & L PCC M-15 grade (nominal mix) using 20mm graded stone aggregate as in roof kerbs of mud stops, rounded or chamfered on edges or as in sunken floor complete all as specified & directed
Making hole and M&L for fixing nozzles in construction joints/whereas required and patching the joint with cement sand mortar and grouting or other equivalent with pressure pump 40-60 PSI in the nozzle thus fixed with cement slurry admixed with Non shrink polymeric grouting compound(Make Pidilite or equivalent ) and clean the RCC Subdtrate of all oil, grease and loosely adhering particles and repairs the cracks with CM 1:3 and Dr Fixit Pidicrete URP all as specified and directed.
M&L for applying two coats fibre reinforced elastromeric liquid applied water proofing membrane coating (Asian smart care damp proof /Dr fixit roof seal classic or equivalent) over a coat of prime seal (Dr Fixit Prime seal or equivalent) of roof all as specified and directed all as specified and directed by Engineer-in-charge
M&L for applying 20-40 mm in width Polyurethane sealant (Silane -terminated polyurethane compound) for sealing of dynamic joints and cracks in interior as well as exteriors of Expansion joints/construction joints and other cracks all as specified and directed all as specified and directed by engineer-in-charge. Make : Asian smart care hybrid Pu sealant /Dr fixit PU sealant or equivalent.
S&F 45mm dia Closed-cell polymer-based foam filler rod( supreme Dura rod or equivalent) in construction/Expansion joints wherever required and patching the joint complete all as specified and directed
S&F 20-40 mm thick Crosslinked, pre-moulded, compressible joint filler board like Supreme "DURA BOARD HD 100"or equivalent ) in expansion joints whereas required and patching the joint all as specified and directed
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering and wall cladding all as specified and directed
S&F in repairs 0.63mm thick, plain galvanised mild steel sheet in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 in crumble / expansion joint and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to RCC wall framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required all as specified and directed. Note for item Nos 23, 24 & 25 :- sefety precautions scaffolding and safety measures like rope, safety belts, helmets, ledder etc required shall be deemed to be included in unit rate coated.
Taking down cement plaster in any description incl racking out joints hacking for key and scrubbing down with water etc complete all as specified and directed
M&L rendering 15 mm thick (10mm + 5mm) plaster on fair face of brick work or concrete surface in CM 1:4 and surface finished even and fair by mixing liquid water proofing compound as per manufacturers instructions complete. Note :- Liquid WPC shall be measured & paid seprately under relevant item of this BOQ.
M&L for applying two coats of weather proof acrylic exterior paint (100%) Acrylic) over a coat of self primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and directed by Engr-in-Charge.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for re-fixing or removal to store.
Supplying & fixing to walls and ceiling 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls and ceiling 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Refixing old steel tubing and connection of 15 mm dia in new or old position walls, ceiling, floor etc
Refixing old steel tubing and connection of 20 mm dia in new or old position walls, ceiling, floor etc
S&F in repairs water closet (Squat Pattern) complete incl provn of lime concrete bedding Orissa pattern size 580 x 440mm white integral foot rests (excluding flush pipe or flushing cisterns) including connection to trap and flushing pipe anti syphonage pipe etc complete and making good to floor.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonage pipe etc complete and making good to floor.
S&F in repairs PVC low level flushing system 10 Ltr capacity with flush pipe complete as specified and directed.
S & F in repairs stopvalves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15 mm dia all as specified and directed.
S&F in repairs two way bib tap 15mm chromium plated complete all as specified.
S&F in repairs grating square or circular 125mm dia of PTMT (minimum weight 100 gms) all as specified and directed.
Taking down drain pipes (any size or pattern), including all fittings, T, bends,etc., including cleaning or refixing (measured overall as fixed along the centre line over fitting and accessories)
S&F 100 mm bore cast iron sand cast pipes, waste and vent pipes, in any length without ear with cement joints, fixed to walls.
S&F in repairs Cast iron floor trap 100 mm bore with grating including jointing to waste pipe and fixed with PCC M-15 grade (nominal mix) using 20mm graded stone aggregate all as specified and directed.
S&F in repairs 75 mm bore Cast iron soil waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors.
S&F in repairs 75 mm bore Cast iron floor trap with grating including jointing to waste pipe and fixed with PCC M-15 grade (nominal mix) using 20mm graded stone aggregate all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) pipes type 'A' single socketed, in any length with rubber ring joints, fixed on walls complete all as specified.
S&F in repair 75 mm bore PVC (SWR) pipes type 'A' single socketed, in any length with rubber ring joints, fixed on walls complete all as specified.
S&F in repair,110mm dia PVC (SWR) bends any radius all as specified and directed.
S&F in repair,110mm bore PVC (SWR) branch pieces, single ( single Y ) equal or unequal all as specified and directed.
S&F in repair,110mm bore PVC (SWR) junction single ( single T) equal or unequal all as specified and directed.
S&F in repair, 75 mm dia bends any radius all as specified and directed.
S&F in repair, 75 mm bore PVC (SWR) junction single ( single T) equal or unequal all as specified and directed.
S&F in repair,75 mm bore PVC (SWR) branch pieces, single ( single Y ) equal or unequal all as specified and directed.
M&L PCC M-5 grade (nominal mix) using 40mm graded stone aggregate as in mass concrete or as in sunken floor complete all as specified & directed
M&L 75mm thick PCC M-7.5 grade (nominal mix) using 40 mm graded stone aggregate as in sub base all as specified.
Dismantling water tanks of capacity exc 250 litres but n exc 500 litres and removing to store all as specified
Dismantling water tanks of capacity exc 750 litres but n exc 1000 litres and removing to store all as specified
Fixing only 500 liters capacity hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc complete.
Fixing only 1000 liters capacity hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc complete.
S&F in repairs wash hand basin vitreous china white flat back of size 550 x 400 mm including PVC flexible waste pipe 32 mm bore 450mm long PVC connection pipe, chromium plated brass waste fittings 32 mm including 15 mm bore chromium plated pillar taps complete all as directed
S&F in repairs pillar taps chromium plated cast copper alloy with capstan heads screwed down high pressure with or without lettered Hot Or Cold Withlong screwed shanks and fly nuts screwed for iron pipes 15mm dia all as specified and directed
S&F in repairs Fancy type bib taps chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule 15mm dia all as specified and directed by Engineer-in-Charge
S&F of PVC connections 15mm size with brass nut on both end washers of length 450mm all as specified
Supply and fix in repairs 750 liters capacity white colour triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc complete.
Supply and fix in repairs 500 liters capacity white colour triple layer, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc complete.
S & F 15 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed ( Minimum weight 15 mm - 142 grams) complete all as specified and directed.
S & F 20 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed ( Minimum weight 20 mm - 210 grams) complete all as specified and directed.
M&L for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise n.exc 100 sq.cm all as specified and directed
M&L for Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise exc 100 sq.cm and n.exc 250 sq.cm all as specified and directed
Demolition of brick work, PCC block mansonry or stone boulder masonary built in cement mortar including all quoins arches pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles.
M&L for Brickwork with fly ash bricks (old size) straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified.
L.K.R.TIWARI CONSTRUCTION
S.R.M.K Enterprises
MAHESH DADAJI BACHHAV
SAMBHAJI D JARANDE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .