Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹41.0 L+₹2.8 L (7.28%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹44.5 L+₹6.3 L (16.5%)Rejected-Finance | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹45.5 L+₹7.3 L (19.2%)Rejected-Finance | L4 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹70,500
Closing Date
17 Sept 2022, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER JORHAT, MES, JORHAT-785005
SPL REPAIR AND AUGMENTATION OF WATER SUPPLY INSTALLATION AND ALLIED WKS AT PH AND PROVN OF DRAINAGE SYSTEM FOR MECHANICAL LAUNDRY PLANT AT ROWRIAH IN JORHAT MIL STN UNDER GE JORHAT
2022_MES_533624_2
8062/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
JOR-05
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
GARRISON ENGINEER JORHAT
₹70,500
Yes
27 Sept 2022
29 Aug 2022
19 Sept 2022
29 Aug 2022
17 Sept 2022
4 Sept 2022
29 Aug 2022 - 1 Sept 2022
Amount
NOTES :The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out as in soft/loose soil.
Removing excavated material (soil) not exceeding 50 m and depositing where directed at a level n. exc. 1.50 m above the starting point.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil.
Material & Labour for Plain Cement Concrete M-10(Nominal Mix) using 20 mm graded stone aggregate as in coping, bed plates, wheel guard & other similar work etc. including weathering, slightly rounded or chamfered angles and throating and necessary form work complete complete all as specified and directed .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to stores and rubbish off the MOD premises complete all as specified and as directed.
Demolition of cement concrete ( un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing debris to a distance n.exc. 50 m etc complete all as specified and as directed.
Material & Labour Non skid ceramic tiles(digital type), coloured, 7 to 8 mm thick (square/rectangular area of each tile exceeding 0.11Sqm and not exceeding 0.16Sqm , in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed layer in CM (1:4) including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc and brushign neat cement slurry with 3.0 kg of cement per Sqm complete all as specified and as directed.
Material & Labour Glazed ceramic tiles 450x300x7 mm(Coloured) on vertical surfaces such as skirting, dados and riser to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match complete over 10mm thick screed bed vertical layer in CM (1:4)all as specified and as directed.
Supplying, hoisted and fixed in position of rotational moulded polyethylene water storage tanks in double layers and cylindrical vertical type with manhole lids(closed top) of 2000 litres capacity with ISI marke all as specified in IS 12701 complete all as specified and directed .
Supply, install, fixing, commissioning and testing of centrifugal monoblock pumping set discharge capacity 8.8 to 30 LPM at 24m-15m head with bronze impeller with energy efficieny motor conforming to IS : 12615 suitable for 415V 3 phase 50 cycle AC supply suitable for sewage water complete all as specified and as per manufacturer's specifications.
Supply, install, fixing, commissioning and testing of flameproof pumping set of discharge capacity 5 -10 LPM , 5m-8m head with bronze impeller and energy efficient flame Proof motor with mechnical seal conforming to IS : 12615 suitable for 415V 3 phase 50 cycle AC supply suitable for pumping diesel including electric connection from Starter to motor in MS conduit complete all as specified and as per manufacturer's specifications.
Supply, install, fixing, commissioning and testing of centrifugal monoblock pumping set discharge capacity 6-30LPM at 15 - 30 m head with bronze impeller with energy efficieny motor conforming to IS : 12615 suitable for 240V single phase 50 cycle AC supply suitable for clear water including 5 m suction pipe of suitable dia complete all as specified and as per manufacturer's specifications.
Materials and Labour for galvanized steel tubing, medium grade, 100 mm bore with all fittings, laid in trenches, and including taking up old GI pipe complete all as specified and as directed.
Materials and Labour for galvanized steel tubing, medium grade, 80 mm bore with all fittings, laid in trenches, and including taking up old GI pipe complete all as specified and as directed.
Materials and Labour for galvanized steel tubing, medium grade, 50 mm bore with all fittings, laid in trenches, and including taking up old GI pipe complete all as specified and as directed.
Materials and Labour for galvanized steel tubing, medium grade, 40 mm bore with all fittings, laid in trenches, and including taking up old GI pipe complete all as specified and as directed.
Materials and Labour for galvanized steel tubing, medium grade, 25 mm bore with all fittings, laid in trenches, and including taking up old GI pipe complete all as specified and as directed. Note for item no 15 to 18- All fitting & fixture such as Bends, Elbows, Tees, Short Pieces, Connectors, Back - Nuts Caps, Plugs, Unions, Flange (core) & flange (ring), reduction Tee, reducing socket, Male & female threaded socket, tank connector, holding clamp shall be provide as per site requiredment and same shall deem to be included in quoted rate.
Supply and fixing bronze foot valve with strainer at suction side of 80 mm dia with necessary nuts, bolts, flange, nipple with leather inside valve etc. including packing/fittings in suction line complete all as specified and directed.
Supply & fixing of 80 mm nominal bore cast iron swing check type reflux ( Non-Return) valve with by-pass arrangment and PN-1.6 conforming to IS 5312 including rubber gasket, flanges, nuts, bolts & washers complete all as specified.
Supply & fixing of 50 mm nominal bore cast iron swing check type reflux ( Non-Return) valve with by-pass arrangment and PN-1.6 conforming to IS 5312 including rubber gasket, flanges, nuts, bolts & washers complete all as specified.
Supply & fixing of 100 mm nominal bore cast iron swing check type reflux ( Non-Return) valve and PN-1.6 conforming to IS 5312 including rubber gasket, flanges, nuts, bolts & washers complete all as specified.
Supply and fixing in repair of sluice valve cast iron body class PN-1.5 with flanged ends drilled suitable for bore of pipe 150mm, conforming to IS: 14846 with and including brass spindle, MS bolts, nuts, washers and a pair of rubber gasket ISI mark including taking dwon old one complete all as specified.
Supply and fixing in repair of sluice valve cast iron body class PN-1.5 with flanged ends drilled suitable for bore of pipe 100mm, conforming to IS: 14846 with and including brass spindle, MS bolts, nuts, washers and a pair of rubber gasket ISI mark including taking dwon old one complete all as specified.
Supply and fixing in repair of sluice valve cast iron body class PN-1.5 with flanged ends drilled suitable for bore of pipe 80mm, conforming to IS: 14846 with and including brass spindle, MS bolts, nuts, washers and a pair of rubber gasket ISI mark including taking dwon old one complete all as specified.
Supply, installation, testing and commissioning of water level indicator digital type suitable for OH RCC/PS water reservoir of 15/12 height staging including with necessary wire connection sensor, digital display of water level & equipments and all other accessories if required for fully functioning of indicator complete all as specified and as directed.
Supply, installation, testing and commissioning of Digital Soft Starter for 7.5 / 10 HP, 9 - 14 Amp, 440 Volt, 50 Hz for pump set all complete all as specified and as directed.
Material and labour for glow sign board visible from one side of 1800mm x 900mm size made by MS hollow 25 x25 x2mm thick with GI sheet and sandwiched thansparent acrylic sheet with letters on ACP Sheet on back ( min 6 mm thick) and necssary computerised laser cutting for letters / signs illuminated with LED light 6 W strip light along letters with necessary drivers and twin core PVC insulated shethed multi stranded copper conductor 1.54 sqmm upto 1.0 mtr for connection inculding fixing arrengement to wall ceiling including taking down of old signage all as specified and directed. Note:- The letters or symbols or signs will be engraved as per direction and sample printed on plain paper as per actual size should be got approved from GE
Supply and Fixing in repair of mild steel in base channel of pump etc as per exsiting size including cutting, welding if required at site complete all as specified and as directed.
Supply and Fixing in repair of mild steel in bolts with nuts and washers, size 20mm dia , 100 mm long complete all as specified and as directed.
Supply and Fixing in repair of mild steel in borewell cap, MS clamp etc as per exsiting size including cutting, welding if required at site complete all as specified and as directed.
Material and labour for painting of pumps& motor set of 25/20HP capacity of pumps complete with synthetic enamel paint by spraying including filling with cavities with filler, after cleaning all dust etc complete all as specified.
Material and labour for painting of pumps& motor set of 15HP capacity of pumps complete with synthetic enamel paint by spraying including filling with cavities with filler, after cleaning all dust etc complete all as specified.
Material and labour for painting of pumps& motor set of 05/10HP capacity of pumps complete with synthetic enamel paint by spraying including filling with cavities with filler, after cleaning all dust etc complete all as specified.
Material and labour for preparation of old steel surface of delivery pipe line, sedimandation tank/IRP etc and applying two coats of synthetic enamel paint on steel surfaces of any description over 10 cm in girth or width complete all as specified and directed.
Material and labour for preparation of old steel surface such as electrical panels/cable tray/ladders etc and applying two coats of synthetic enamel paint on steel surfaces of any description over not exceeding 10 cm in girth or width complete all as specified and directed.
Development of exsiting 120m depth tube wells with air compressor of suitable capacity till sand/mud free water of potable quality is obtained and to achieve minimum discharging capacity of 10,000 GPH (compressor with accessories and fuel shall be arranged by the contractor) complete all as specified and as directed Note:The rate shall be inclusive of hiring of Air compressor with fuel /special tools / Accessories including transportation of the same & Labour charges, for specially trained man power for the work of desiliting of bore well .
Lifting the Open well submersible pumping set of capacity upto 15 HP including colum pipe after disconnecting electric cable connection and transporting to store and reassembling the submersible motor pump, lowering including reconnecting colum pipe with new gasket, the electric cable connection and testing complete up to the entire satisfaction of Engineer-in-Charge complete all as directed. Note :- (i) The rates for minor repair, jointing and jointing materials are deemed to be included in the quoted rates.
Supply and fixing of Pressure gauge(dial dule scale), dial size 100 mm, S.S. Tube, dry type , bottom connection , pressure measuring range 0-07 kg/cm2 (100 PSI) including taking down old unservicable pressure gauge complete all as specified and as directed
Supply, installation, testing in repair of fully automatic Star Delta Starter for 12.5 / 15 HP, 9 - 14 Amp , 440 Volt , 50 Hz for Submersible pump all as specified and directed by Engr-in-Charge.
Supply, installation, testing in repair of DOL Starter 10HP / 7.5 HP ,9 - 14 Amp , 440 Volt , 50 Hz all as specified and directed by Engr-in-Charge.
Supply and fixing in repair of 3 layered (outer green coloured UV stabilized, middle black coloured UV stabilized and innermost layer white coloured) PP-R (Polypropylene Random Co-Polymer) concealed pipes 40 mm outer dia SDR7.4(PN-16) with ISI marked, UV-stabilized and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc for rising mains upto OH Tank for pumping chlorine upto OH Tank including testing of joints complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm nominal cross section 3 core for connections to motors & LT Panel
Supply and laying or fixing or passing through pipe PVC insulated Submersible cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core, nominal cross sectional area of main conductor 6 sqmm, stranded aluminium conductor, ISI marked as per IS 1554(Part-I): 1988 complete all as specified and as directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mm nominal cross section 3 core for connections to motors & LT Panel
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mm nominal cross section 2 core for connections to motors & LT Panel
Materials and Labour for, joint with rubber or fibre board gasket for galvanized steel flanged pipes and fittings, 100 mm bore,including provision of bolts, nuts, washers and white lead or mineral oil,after taking down existing joint, complete all as specified and directed.
Materials and Labour for, joint with rubber or fibre board gasket for galvanized steel flanged pipes and fittings, 200 mm bore,including provision of bolts, nuts, washers and white lead or mineral oil, after taking down existing joint,complete all as specified and directed.
Materials and Labour for, joint with rubber or fibre board gasket for galvanized steel flanged pipes and fittings, 300 mm bore,including provision of bolts, nuts, washers and white lead or mineral oil, after taking down existing joint, complete all as specified and directed.
Supply and fixing of indoor type glow-layout sign board of size 2000 mm(min) x 1500 mm(min) x 200 mm(min) thick made out of 0.63 mm thick Plain GI sheet on 25 mm x 25 mm x 2 mm thick anodized aluminum angle frame provided with detachable from cover (made of 3 mm thick white coloured, weather proof polycarbonate sheet, bonded with aluminum angle of suitable size), writing/pasting/ drawing all different cable line in different colour, different installation and any other subject matter as given by Engineer-in-Charge for complete layout plane of pump house/ substation with self adhesive rubber coated synthetic vinyl stickers (blue in colour) including fixing & 06 numbers fluorescent tube light fittings (1 x 28 watt) with electronic ballast, tube lamp complete all accessories (internally to glow sign board) including providing all internal wiring and main connection with 1.5 Sq mm single core stranded copper conductor cable (length not exceeding 4 metres) and providing necessary fixing arrangement and testing on completion complete all as specified and directed .
Supply only CHLORINE TEST KIT with coloured ample complete with all testing fitments and OT solution in Rexene finish box complete all as specified and directed.
Supply only Iron Test Kit with necessary accessories and testing reagents in Kit Box including 500 ml bottle Iron Test solution complete all as specified and directed.
aterial & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer complete all as specified and directed
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron using GI strip 25x4mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternatee layer complete all as specified and directed .
Supply and laying of 40mm bore galvanised steel tubes, light grade for cable protection complete all as specified and as directed.
Material and labour for Sand cushioning to the full width of trenches for protection of cables including punning down complete all as specified and as directed. Note :- Thickness of sand cushioning shall be the thickness after punning down.
Material and labour for laying of Class designation 75 bricks, old size, flat, common clay laid in trenches across the trench as cable protection complete all as specified and as directed.
Material and labour for laying of LT XLPE insulated armoured heavy duty cable 1100 volt grade ISI marked with alumimium conductor multi strand cross sectional area 25Sqmm x 4 Core complete all as specified and as directed.
Supply, installation, testing and commissioning of factory made powder coated (CPRI approved) outdoor type, dust & vermin proof feeder pillar box made out of 3.15mm CRCA steel sheet of suitable size and angle iron 40 mm x 40mm x 6 mm , powder coated over one coat of red oxide primer suitably grouted in PCC-M10 using 20 mm graded stone aggregate including bus bar, internal wiring with PVC insulated single core cables of copper conductor of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type locking arrangement and slanted roof. The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 415 Volt, 3 phase, 50 Hz supply system including disconnecting of electric connection both incoming & out going from existing unsv indoor/outdoor feeder pillar boxes/busbar enclosers and unsv accessories and taking out panel from the foundation . The panel board shall comprise of following items & all specified in SSR Part-I clause no 19.21 and all as shown on drawing .
Supply, Installation, testing & Commissioning of hi wall split type Air conditioners of cooling capacity 1.5 ton , 5 Star Rating of BEE, comprising of indoor/outdoor complete with cordless remote control unit, inverter technology with independent evaporator and one compressor and with in built air ioniser and plasma filter for better indoor air quality, including suitable size copper refrigerant piping with 13mm nitrile rubber insulation, electrical interconnection copper cable between indoor and outdoor units, PVC drain pipe complete all as specified and as directed. NOTE :- (i) The quoted rate shall be deemed to lifting, shifting, positioning at site of all the equipment, fittings, topping up of refrigerant, outdoor control panel, bracket / clamp for indoor/outdoor units installation, vibration isolators, and ancillary material as per manufacturer’s instruction. (ii) Refrigerant piping upto 3 m, copper conductor cable upto 3 m, remote controller, drain pipe upto 3 m shall be measured and paid under above items. Make:- Carrier/Daikin/Hitachi/Bluestar/ Voltas/ Godrej/Samsung
Supply, installation, testing and commissioning refrigerator electric driven single phase capacity 190 litres frost free, minimum five star rated including suitable capacity compressor as per manufacturer's instruction complete all as specified.
Supply, installation, commissioning of Supply and Fixing water cooler made of partially stainless steel body and tank, electric driven, AC single phase, 230 volts, 50 Hz of stoage type with minimum storage capacity of 120 litres and nominal cooling capacity 60 litre per hour with and including suitable capacity compressor as per manufacturer's instruction and including water connection with PVC connection with PTMT nuts length 450 mm complete all as specified.
Supply, installation, commissioning of glass top deep freezer 320 litres capacity, single phase 240 volts, 50 Hz. including suitable capacity compressor as per manufacturer's instruction complete all as specified. Note for item no 62 to 64 :- 1. Make:- Carrier/Daikin/Hitachi /Bluestar/Voltas / Godrej /LG /Samsung 2. In case of any specific capacity are not manufactured by the any above OEM, the contractor shall provide near higher capacity/size equipment by OEM without any extra cost to the department.
Supply and fixing voltage stabilizer for automatic operation, single phase with neutral, air cooled indoor type and designed for input voltage variation between 130 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of +/- 2.5% and capacity of 4 KVA complete all as specified.
Material and labour for point wiring with 4.00 Sq. mm (nominal area) PVC insulated and unsheathed single coreFRLSH copper cable 1100 volts grade with stranded copper conductor in and including PVC rigid concealed conduit (heavy grade) and conduit accessories alongwith continuous earth wire 4.00 Sq mm PVC insulated and unsheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one light point controlled by one switch complete all as specified and as directed.
Supply and fixing switch socket outlet multipurpose 3 pin 15 Amps /5 Amps controlled by one switch complete all as specified and as directed.
Material and labour for sub main wiring with two single core 4.0sqmm (nominal area) PVC insulated copper conductor FRLSH, multi stranded, unsheathed 1100 volts grade IS-694 marked in PVC double lock casing caping and accessories accessories including one single core 4.0 sqmm copper conductor cable FRLSH as earth wire and including taking out old sub-main wiring complete all as specified and as directed. NOTE:- (a) All runs of copper conductor and one run of conduit shall be measured as one run length.
Supply and fixing in repair of sheet metal enclosure for MCBs to be used triple pole & nutral double door 4Way 200 Amps rated busbar and including fixed with 25mm x 6 mm mild steel clamp of suitable length and including taking out old DB complete all as specified and as directed.
Supply and fixing of sheet metal enclosure for MCBs to be used singal pole & nutral double door 8 Way 200 Amps rated busbar and including fixed with 25mm x 6 mm mild steel clamp of suitable length complete all as specified and as directed.
Supply and fixing of MCB SP of rating 6 to 32 Amps 240 V complete all as specified and as directed.
Supply and fixing MCB DP 40 to 63 amps 415 volts 10KA breaking capacity complete all as specified and as directed.
Supply and fixing in repair of MCBs four pole 32 to 63 Amps capacity complete all as specified and as directed.
Supply and fixing of changeover switch 63Amps, 415 Volts including sheet metal enclosure complete all as specified and as directed.
Supply and fixing of Metal distribution box with clad plug and socket and including SPN-MCB control 2 pin & earth plug with socket , 20 A, 240 Volts universal type complete with one MCB 20 A SPN 240 volt complete all as specified and as directed.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ₹ ___________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
KAY CEE CO. INDIA
M/S RK SAHA AND CO
M/S DB TRADING CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .