Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.9 L+₹1.1 L (3.02%)Rejected-Finance 179 URBAN ESTATE RAM TIRATH ROAD NR GURUDAWARA DARSHAN SINGH AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | L2 | Rejected-Finance Higher | |
| 3 | L3₹39.6 L+₹1.8 L (4.79%)Rejected-Finance | L3 | Rejected-Finance Higher | |
| 4 | L4₹39.9 L+₹2.1 L (5.59%)Rejected-Finance M S CHANANA ENGINEERS CONTRACTORS AZAD CHOWK FEROZEPUR CANTT FEROZEPUR PUNJAB 152001 | FIROZEPUR | PUNJAB | 152001 | L4 | Rejected-Finance Higher | |
| 5 | L5₹40.5 L+₹2.8 L (7.31%)Rejected-Finance | L5 | Rejected-Finance Highrer |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
18 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAMS
GE NAMS KHASA CANTT AMRITSAR
REPAIR/MAINT OF ELECT APPLIANCES, ALLIED WORKS AND DAY TO DAY COMPLAINT AT NAMS
2020_MES_407268_1
GE NAMS - 74 / 2020 - 21
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
NAMS CANTT
Class D
Category b i
6 documents required · 6 mandatory
₹500
Yes
GE NAMS
₹99,000
Yes
21 Feb 2021
28 Dec 2020
19 Jan 2021
28 Dec 2020
18 Jan 2021
11 Jan 2021
60 days
Amount
Attending of day to day electrical complaints pertaining to internal electrification received through telephone or in person on detailment at MES Service centre located at NAMS Area by locating and rectification of fault from and including electric meter/DB onwards in respect of sub main/point wiring including provisioning of small pieces of electric cable of size 1.5/2.5 Sqmm to 10 Sqmm single core copper conductor and length not increasing 0.50 mtrs and fixtures for power and light socket/light, fan,and bell etc complete and carrying out repairs to the extent of tightening of looseconnections,disconnection and dismantling of faulty wires, battens, conduits, boxes, main switches, MCB's, DB's and other E/M fixtures including providing necessary screws/nuts/bolts/nails for the rectification of defect and refixing of existing dismantled serviceable items and replacement of defective items with new ones at fwg areas with man power:- (a) At Zone-I NAMS area with one electrician + one helper (08 Hrs shift), daily (b) At Zone-II NAMS area with one electrician + one helper (08 Hrs shift) , daily (c ) At Zone-III & IV NAMS area with one electrician + one helper (08 Hrs shift), daily Note:-(i) Cost of labour for the new fixtures and stores to be fixed by the contractor will be paid under this Item No.1 and material cost for the fixing/replacement of unserviceable item shall deemed to be measured as supply only against relevant Items No.2 to 72 . (ii) Complaint pertaining to location and rectification of fault in more than one length of point wiring/sub mainwiring/DB's/fitting or fixtures etc shall be considered as an independent complaint. Similarly complaint pertaining to replacement of two fixtures in one Qtr will also be measured and paid as one complaint.
(iii) Replacement of more than two fixtures/items but multiple of three fixtures or part thereof in one Qtr/Bldg will be measured as an additional complaint. (iv) In case a Qtr/room is found locked when tradesman is detailed to attend the complaint, the complaint shall be treated as open till its completion. (v) Necessary tools for tradesman shall be provided by the contractor. (vi) Transportation for tradesman and normal stores required for complaints shall be arranged by the contractor. (vii) Complaints of normal nature shall be attended and rectified within 8Hrs of receipt of complaint. However, complaints of emergent nature i.e no light, short circuit, earth fault etc shall be attended immediately on receipt of complaint round the clock. (viii) Bldgs requiring rewiring of small qty of point wiring if ordered will be measured and paid separately under respective items below (ix) Contractor will deposit all the items to EM Store in advance and unsv items will be collected by the contractor as schedule of credit.
Supply only in replacement switch piano flush type 5 Amps One-way, AC 230V on existing switch board all as specified and as directed.
Supply only in replacement switch piano flush type 15 Amps single pole one-way, 230V complete all as specified and as directed.
Supply only in replacement switch piano type two ways AC 230 volts 6 Amps as per on existing switch board .
Supply only in replacement socket out let 2-in-1, 3 Pin 5 Amps flush type 230 volts complete all as specified and as directed.
Supply only in replacement socket outlet, flush type, 2-in-1, 3 pins, 5 & 15 Amps multipurpose complete all as specified and as directed.
Supply only in replacement bell push switch piano, flush type, 5 Amps complete all as specified and as directed.
Supply only in replacement of bell ding-dong 230 volts, single phase complete all as specified and as directed.
Supply only in replacement of ceiling rose 65x50mm two to three terminals AC 230 volts complete all as specified and directed of any make/model as per in existing building.
Supply only in replacement roter type Bipin holder of any size/shape as required at site for 20/28/40 watts tube light 240 Volts complete all as specified and as directed.
Supply only in replacement batten type angular/ Battan lamp holder insulated body with back plate suitable for batten fitting including PVC round block complete all as specifed and as directed.
Supply only in replacement LED out door drivers 25W suitable for security light 25 watt, AC 230V complete all as specified and as directed.
Supply & fix in replacement MCBs single pole 5 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards all as specified.
Supply & fix in replacement MCBs single pole and neutral 40 Amps with 10 KA breaking capacity of 'C' series in distribution boards all as specified and directed.
Supply & fix in replacement MCBs single pole and neutral 63 Amps with 10 KA breaking capacity of 'C' series in distribution boards all as specified and directed.
Supply only in replacement of single pole and neutral sheet metal enclosures with two pin & earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and as directed.
Supply only in replacement plug top 3 pin, 5 Amps complete all as specified and as directed.
Supply only in replacement plug top 3 pin, 15 Amps complete all as specified and as directed.
Supply & fix in replacement Electronic Ballast (P.F 0.9), 230v, 50HZ, 36 watt complete all as specified.
Supply & fix in replacement fluorescent tube light rod 4 feet long of capacity 36 watt all as as directed by Engr-in-Charge.
Supply & fix in replacement LED bulb of capacity 5 watts complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge.
Supply & fix in replacement LED bulb of capacity 7 watts complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge.
Supply & fix in replacement LED bulb of capacity 9 watts complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge.
Supply & fix in replacement LED bulb of capacity 12 watts complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge.
Supply & fix in replacement LED bulb of capacity 15 watts complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge.
Supply & fix in replacement LED Tube rod LED tube rod with polycarbonate diffuser 4 feet long of capacity 18 watts complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge.
Supply & fix in replacement LED Tube rod LED tube rod with polycarbonate diffuser4 feet long of capacity 20 watts complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge.
Supply & fix in replacement LED Tube rod LED tube rod with polycarbonate diffuser4 feet long of capacity 22 watts complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge.
Supply & fix in replacement LED bulb of capacity 9 watts, threaded type suitable for post top lantern complete with all accessories base (ISI marked) all as specified & directed by Engr-in-Charge.
Supply & fix in Replacement of existing sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 4.0 Sqmm drawing into and including PVC non metallic rigid conduit of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 4.0 Sqmm as a earth continuity conductor(green colour) in and including in non metallic rigid PVC conduit, including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Note :- (i) Rates are deemed to be included chases of conduit and sinking for boxes cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of 4.00 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 4.0 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
All as per item 31 here in before but with 2 run of 6.0 Sqmm and one run of 6.0 Sqmm as earth continuity conductor(green colour) complete all as specified & directed.
All as per item 31 herein before but with 2 run of 10.0 Sqmm and one run of 10.0 Sqmm as earth continuity conductor(green colour) complete all as specified & directed.
Supply only in replacemet of CFL bulb 36 watts, four pin type suitable for CFL fitting all as specified and directed by Engineer-in -charge
Supplying only in replacement LED bulk head light fittings including led lamp 10watt as per IP65 and making necessary connections complete all as specified
Supply only in replacement LED slim panel cygnus series recess/surface/suspended mounting LED slim ceiling light 2'x2' with extruded aluminium housing and milky diffuser, suitable for recess mounted size 595x595mm complete with LED tube.
Supply only in replacement of 6 Watt Round recess mounted down lighter separate replaceable electronic driver celling cut out dia 105 mm height 16 mm round shaped polycarbonate fixture complete all as specified and directed,
Supply only in replacement of 12 Watt Round recess mounted down lighter separate replaceable electronic driver celling cut out dia 160 mm height 16mm round shaped polycarbonate fixture complete all as specified and directed,
Supply only in replacement of 6 Watt Square recess mounted down lighter separate replaceable electronic driver celling cut out 104mm x 104mm height 30mm square shaped polycarbonate fixture complete all as specified and directed,
Supply only in replacement of 15 watt Square recess mounted down lighter separate replaceable electronic driver celling cut out 155mm x 155mm height 32mm square shaped polycarbonate fixture complete all as specified and directed,
Supply only in replacement in replacemnt PVC rectangular block for mounting switches, sockets, fan regulator etc 3mm thick plastic laminated sheet cover of size 100mm x 100mm and 50mm deep complete all as specified and as directed.
Supply only in replacement of PVC rectangular block for mounting switches, sockets, fan regulator etc 3mm thick plastic laminated sheet cover of size 175mm x 100mm x 50mm deep complete all as specified and as directed.
Supply only in replacement of 3mm thick plastic laminated sheet of size 200mm x 100mm including screws and washers etc complete all as specified and as directed.
Supply only in replacement of frame plate for modular switch 3/4 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
Supply only in replacement of frame plate for modular switch 6/8 module including screws and washers etc model/make as per existing in site complete all as specified and as directed.
Supply only in replacement insulation deteriorated PVC insulated flexible copper conductor cable twin twisted of Size 24/0.20mm 1100 volts grade complete all as specified and as directed.
Supply only in replacement modular ceiling fan regulator, electronic Socket type, single phase, 230 volts complete all as specified and as directed.
Supply only in replacement ceiling fan regulator, electronic switch type, single phase, 230 volts complete all as specified and as directed.
Supply only in replacement MS machine screw 25 mm long suitable for fixing bakelite hylam sheets / square blocks complete all as specified and directed .
Supply only in replacement MS Housing box 5/6 module suitable for modular switch as per existing including taking out old UNSV switch box and making good to the disturb surface by pcc complete all as specified and as directed.
Supply only in replacement of MCCB 100 amps , AC 415 volts 16 KA, Three pole including making connections with suitable size of aluminium lugs of any make /Model as per Existing MCCB Fitted in DB. all as specified.
Supply only in replacement of modular switch 5/6 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
Supply only in replacement of modular switch 15/16 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
Supply only in replacement of modular socket, 5/6A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed.
Supply only in replacement of modular socket, 15/16A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed .
Supply only in replacement modular fan regulator, 2 Module/1 module , 4 step heavy duty 230 volts as per existing model/make complete all as specified and as directed.
Supply only in replacement of capacitor AC 230 volts 2.25 MFD
Supply only in replacement of capacitor AC 230 volts 3.15 MFD
Supply only in replacement of 3mm thick hylam sheet of any size including screws and washers etc as per required at site complete all as specified and as directed.
Supply only in replacement moduler bell push switch piano, flush type, 6 Amps complete all as specified and as directed.
Supply only in replacement of 12 Watt Square recess mounted down lighter separate replaceable electronic driver celling cut out dia 160 mm height 16mm round shaped polycarbonate fixture complete all as specified and directed.
Supply only in replacement tuggle switch for amination depot complete all as specified and as directed.
Supply & fix in replacement LED tube light fitting. ,1x20w, 230v Energy efficient T8, Box type made of CRCA shee heavy duty industrial type housing with reflector cover channel, bipin holders, connector block, etc. complete with tube rod LED 20 watt, all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply & fix in LED mirror fitting. 1x8w, 230v Energy efficient , Box type, housing with reflector cover channel, bipin holders, connector block, etc. complete with tube rod LED 8 watt, all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply and fixing bed light fancy type,10watt with lamp complete all as specified and directed.
Supply only in replacement of single core wire 2.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed.
Supply only in replacement of single core wire 1.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm multi strand pvc insulated copper conductor cable in existing concealed conduit for one light or bell point controlled by one switch including pvc insulated 1.5 sqmm copper conductor continuous earth wire using existing CI/MS sunken box and connecting earth with dolly incl taking down of old wiring complete all as specified and directed. (Note : Switch, socket measured as separate item )
All as per item No 68 here in before but for one 5 Amps independent board complete
All as per srl item No. 68 here in before but for one 5 amps socket out but on the same board complete
Matrial and labour for point wiring with 2.5 sqmm multi strand pvc insulated copper conductor cable in existing concealed conduit for one 15 amps socket outlet independent controlled by one switch including pvc insulated 2.5 sqmm copper conductor continuous earth wire connecting earth with dolly incl taking down of old wiring complete all as specified and directed.
Supply & fix in replacement of building security LED Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens complete all as specified.
Supply and fix in repair GI pipe bracket ,made out of GI pipe 50mm dia light grade 1.2mtr long bend to the shape 120 degrees angle complete with two nos of clamps for fixing on walls complete all as specified and directed.
Taking down Exhaust Fan of any make & size from existing position of any height for repair, mainteance and refixing the same after neccesary repair complete all as directed. Notes (i) The defective parts to be replaced shall be measured and paid separately under relevant item of Sch . (ii) Cost of minor items i.e. Screws, nut & bolts etc shall be deemed to be included in the above item.
Supply & fix in replacement double ball bearing (ISI marked) for exhaust fan of 450mm sweep capacities.
Supply & fix in replacement double ball bearing (ISI marked) for exhaust fan of 300mm sweep capacities.
Supply & fix in replacement Gun metal bush for Exhaust fan of any cap/ any size sweep complete.
M&L for removing old burnt winding of exhaust fan 450mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge.
M&L for removing old burnt winding of exhaust fan 300mm sweep motor and rewinding the same with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge.
Supply & fix in replacement blade suitable for exhuast fan of 450mm sweep of existing make complete all as directed and specified by Engr-in- Charge.
Supply & fix in replacement blade suitable for exhuast fan of 300mm sweep of existing make complete all as directed and specified by Engr-in- Charge.
Supply & fix in replacement louvers shutter suitable for exhuast fan of 450mm sweep of existing make complete all as directed and specified by Engr-in- Charge.
Supply & fix in replacement louvers shutter suitable for exhuast fan of 300mm sweep of existing make complete all as directed and specified by Engr-in- Charge.
Supply & fix in replacement of capacitor 4 mfd ISI marked complete all as directed.
Taking down ceiling fan of any make & sweep by disconnecting clips,lock nuts etc. from existing position of any height in safe costudy for repair & mainteance. (Note: Repair & Maintance Shall be paid separetly under relevant items.)
Hanging only ceiling fan 1200mm/1400mm sweep after repair & maintenance with existing down rod clips,lock nuts etc. Note:- Refixing of repaired fan in any location of NAMS area with in distance of 4 Km shall be contractors responsiblility at his own arrangement of transport and tool and plant.
M&L for Painting of ceiling fans complete, in situ/lying in store with synthetic enamel paint (white colour) by spraying including filling cavities with filler, one coat after cleaning all dust etc
M&L for removing of old burnt winding of fan any type and rewinding the stator with superior quality super enamelled copper wire of suitable size including insulation ,drying after varnishing complete all as directed and specified by Engr-in- Charge.
Supply & fix in replacement bearing for ceiling fan 1200mm/1400mm sweep ISI marked.
Supply & fix in replacement Gun metal bush for ceiling fan 1200mm/1400mm sweep.
Supply & fix in replacement cup made of plastic complete with nut bolt for fixing in position suitable for ceiling fan 1200mm/1400mm sweep
Supply & fix in replacement rubber bush/reel for hanging bracket suitable for ceiling fan 1200mm / 1400mm sweep
Supply & fix in replacement blade suitable for 1200mm sweep Ceiling fan complete all as directed.
Supply & fix in replacement blade suitable for 1400mm sweep Ceiling fan complete all as directed.
Supply and Replacement of split pin 40 mm to 50 mm long complete all as specified and directed.
Supply and replacement of steeel screw ( to be used for fixing of fan blades) as per sample /site requirement).
Supply & fix in replacement 3 core PVC insulated PVC sheathed flexible copper wire multistranded 1.5sqmm from ceiling rose to fan connector.
Supply & fix in replacement of capacitor 2.5 mfd ISI marked complete all as directed.
Supply & fix in replacement of capacitor 3.15 mfd ISI marked complete all as directed.
Taking down and refixing in PVC Exhaust Fan motor in replacement for 250 mm sweep , 230 volts 50 c/s complete all as specified and directed.
Taking down and refixing PVC Exhaust Fan blade in replacement for 250mm sweep 230 volts 50 c/s complete all as specified and directed.
Taking down and refixing PVC Exhaust Fan body in replacement for 250mmsweep, 230 volts 50 c/s complete all as specified and directed.
M&L for repair/ replacement of PVC wall mounting fan 400mm sweep, pull chain type, 230v 50 Hz complete all as specified and as directed.
M&L for repair/ replacement of Padestal fan 400 mm sweep , 230v, 50Hz complete all as specfied and as directed.
Excavation in trenches not exc 1.5 mtr and n. exc 1.5 mtr depth for laying of XLPE cable etc and getting out in any type of soil complete all as specified and directed by Engineer-in- Charge.
Returning filling in and including , spreading, levelling , watering and well raming in layers not exceeding 25 cm complete all as specified.
Removing excavated material n. exc 50m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminiumconductor of size 16 Sq mm 4 core complete all as specifiedc and as directed.
Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. all as specified and directed by Engr in Charge.of size54 mm outer dia and 38 mm inner dia complete all as specified and as directed.
Supply & fixing in replacement of integral post top lantern complete with black ABC plastic spigot, spun aluminium funnel shape with clear acrylic cover light opening on canopy with baffles and accessories and suitable for LED min 25Watt lamp complete all as specified and directed
Supply and fixing in replacement of sheet metal enlosure for DBs when MCBs to be used double door factory made flush fixed complete with 100 amps rated bus-bar 240 volts single phase 8 ways including necessary brick work and plaster to match with the existing surface complete all as specified.
Supply and fixing in replacement of sheet metal enlosure for DBs when MCBs to be used double door factory made flush fixed complete with 100 amps rated bus-bar 240 volts single phase 12 ways including necessary brick work and plaster to match with the existing surface complete all as specified.
Supply only in replacemnt FTL Rod 14W, 220V AC white incandescent effect complete all as specified and directed by Engineer-in -charge.
M& labour in replacelment for service wire 10 sqmm 2core pvc insulated and pvc sheathed 1100 volts grade all as specified and directed
M& labour in replacelment for service wire 16 sqmm 2core pvc insulated and pvc sheathed 1100 volts grade all as specified and directed
Servicing/ Inspection of water cooler of any cap/type/make installed at different units at NAMS on site including disconnecting electric and water connection of water cooler finding of defect including dismantling of compressor, relay, capacitor, thermostat, motor, PVC hose pipe, condensing coil including fixing new spares complete as required all as specified and directed by Engineer -in-charge. Note (i) The new spare parts required to make the water cooler serviceable shall be measured and paid separately under relavent items. (ii) Transportation charges for carrying the plant from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates. (iii) Replacement of minor spare parts whose cost are less than 100 rupees including cleaning of water tank, serciving etc are deemed to be included in quoted rates. no extra cost shall be paid for the same. (iv) Rectifying, detecting the Gas leakage, Flexing, Pressuring, ,vacumising, filling for charging of refrigerant gas shall be included in the quoted rate no extra cost paid to the contractor for the same. Refrigerant gas shall be measured and paid seperately under relevent item.
Supply only Hermetic compressor unit for water cooler of 40/80 ltr Complete all as specified and as directed by Engr-in-Charge.
Supply only Hermetic compressor unit for water cooler of 60/120 ltr cap Complete all as specified and as directed by Engr-in-Charge.
Supply only Hermetic compressor unit for water cooler of 150 ltr cap Complete all as specified and as directed by Engr-in-Charge.
Supply only starting relay CAJ-2612 Complete all as specified and as directed by Engr-in-Charge.
Supply only over load protection relay suitable for any cap of water cooler Complete all as specified and as directed by Engr-in-Charge.
Supply only starting capacitor 40-80 Mfd for any cap of water cooler Complete all as specified and as directed by Engr-in-Charge.
Supply only starting capacitor 100-120 Mfd for any cap of water cooler Complete all as specified and as directed by Engr-in-Charge.
Supply only thermostat suitable for any cap water cooler Complete all as specified and as directed by Engr-in-Charge.
Supply only fan motor of capacity 1/10 to 1/35 HP 50c/s, 230 volts Complete all as specified and as directed by Engr-in-Charge.
Supply only PVC hose waste pipe with SS clamp suitable for water cooler of any capacity Complete all as specified and as directed by Engr-in-Charge.
Supply only drain tray , stainless steel for water cooler of any cap complete all as specified and as directed.
Material and Labour for replacement of old damage rusted water cooler body with new water cooler body fabricated from MS Sheet 18 Guage thick, necessary angle iron work of required size, cleaning, washing the sheet with moderate solution, duly painted with two coats of synthetic enamel paint over one coat of red oxide primer including writing MES/SM number with white paint of appropriate size complete all as directed by Engineer In Charge.
Servicing /Inspection of refrigerators of any cap/type/make installed at different units at NAMS on site, finding of defect including dismentling of compressor, relay, capacitor, thermostat, motor, condensing coil , door, rubber gasket, ice box assembly including fixing new spares complete as required all as specified and directed by Engineer -in-charge. Note (i) The new spare parts required to make the water cooler serviceable shall be measured and paid separately under relavent items. (ii) Transportation charges for carrying the plant from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates. (iii) Replacement of minor spare parts whose cost are less than 100 rupees including cleaning of water tank, serciving etc are deemed to be included in quoted rates. no extra cost shall be paid for the same. (iv) Rectifying, detecting the Gas leakage, Flexing, Pressuring, ,vacumising, filling for charging of refrigerant gas shall be included in the quoted rate no extra cost paid to the contractor for the same. Refrigerant gas shall be measured and paid seperately under relevent item.
Supply only hermetic compressor unit for refrigerator of capacity 165-200 Complete all as specified and as directed by Engr-in-Charge.
Supply only hermetic compressor unit for refrigerator of capacity 210-360. Complete all as specified and as directed by Engr-in-Charge.
Supply only over load protection relay for refrigerator of any capacity any type Complete all as specified and as directed by Engr-in-Charge.
Supply only starting relay for refrigerator of any cap/ any type Complete all as specified and as directed by Engr-in-Charge.
Supply only thermostat for refrigerator of any capacity/any type Complete all as specified and as directed by Engr-in-Charge.
Supply only Refrigerator shelve (jaali type) for refrigerator of cap 170 Ltrs - 360 Ltrs Complete all as specified and as directed by Engr-in-Charge.
Supply only PC Board for 270 to 360 ltr refrigerator suitable make all as specified and as directed by Engr-in-Charge.
Supply only timer for refrigerator complete all as specfied and as directed.
Servicing /.Inspection of Deep Freezer of any cap/type/make installed at different units at NAMS on site, finding of defect including dismentling of compressor, relay, capacitor, thermostat, motor, condensing coil , door, rubber gasket, ice box assembly including fixing new spares complete as required all as specified and directed by Engineer -in-charge. Note (a) The new spare parts required to make the water cooler serviceable shall be measured and paid separately under relavent items. (b) Transportation charges for carrying the plant from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates. (c) Replacement of minor spare parts whose cost are less than 100 rupees including cleaning of water tank, serciving etc are deemed to be included in quoted rates. no extra cost shall be paid for the same (iv) Rectifying, detecting the Gas leakage, Flexing, Pressuring, ,vacumising, filling for charging of refrigerant gas shall be included in the quoted rate no extra cost paid to the contractor for the same. Refrigerant gas shall be measured and paid seperately under relevent item.
Supply only hermetic compressor unit of deep freezer of 300-400 ltr capacity Complete all as specified and as directed by Engr-in-Charge.
Supply only hermetic compressor unit of deep freezer of 100-205 ltr capacity Complete all as specified and as directed by Engr-in-Charge.
Supply only fan motor for deep freezer upto 400Ltrs cap Complete all as specified and as directed by Engr-in-Charge.
Servicing/ Inspection of AC window type of any cap/type/make installed at different units at NAMS on site, finding of defect including dismentling of compressor, blower motor, evaporating coil, relay, thermostat, condensing coil , including fixing new spares complete as required all as specified and directed by Engineer -in-charge. Note (i) The new spare parts required to make the water cooler serviceable shall be measured and paid separately under relavent items. (ii) Transportation charges for carrying the plant from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates. (iii) Replacement of minor spare parts whose cost are less than 100 rupees including cleaning of water tank, serciving etc are deemed to be included in quoted rates. no extra cost shall be paid for the same. (iv) Rectifying, detecting the Gas leakage, Flexing, Pressuring, ,vacumising, filling for charging of refrigerant gas shall be included in the quoted rate no extra cost paid to the contractor for the same. Refrigerant gas shall be measured and paid seperately under relevent item.
Supply only rotary hermetic compressor unit for window air conditioner 1.5/2 Ton capacity, specifications as per existing Complete all as specified and as directed by Engr-in-Charge.
Supply only reciprocating hermetic compressor unit for window air conditioner 1.5 Ton capacity, specifications as per existing Complete all as specified and as directed by Engr-in-Charge.
Supply only condensing coil for window air conditioner of cap 1.5 /2 ton capacity Complete all as specified and as directed by Engr-in-Charge.
Supply only evaporating coil for window air conditioner of cap 1.5/2 ton capacity Complete all as specified and as directed by Engr-in-Charge.
Supply only thermostat for window AC 1.5/2 ton as per existng make complete all as specifeid and directed.
Supply only micron filter suitable for 1.5/2 Ton window AC Complete all as specified and as directed by Engr-in-Charge.
Supply only blower motor for window air conditioner of capacity 1.5 /2 ton, type & specification as per existing Complete all as specified and as directed by Engr-in-Charge.
M&L for Window AC front grill complete as per existing for 1.5 Ton Complete all as specified and as directed by Engr-in-Charge.
Servicing / Inspection of AC Split type of any cap/type/make installed at different units at NAMS on site, finding of defect including dismentling of compressor, blower motor, evaporating coil, relay, thermostat, condensing coil , including fixing new spares complete as required all as specified and directed by Engineer -in-charge. Note (i) The new spare parts required to make the water cooler serviceable shall be measured and paid separately under relavent items. (ii) Transportation charges for carrying the plant from site to workshop and back at site incl testing & fixing are deemed to be included in quoted rates. (iii) Replacement of minor spare parts whose cost are less than 100 rupees including cleaning of water tank, serciving etc are deemed to be included in quoted rates. no extra cost shall be paid for the same. (iv) Rectifying, detecting the Gas leakage, Flexing, Pressuring, ,vacumising, filling for charging of refrigerant gas shall be included in the quoted rate no extra cost paid to the contractor for the same. Refrigerant gas shall be measured and paid seperately under relevent item.
Supply only hermetic compressor unit for split air conditioner 1.5/2.5 Ton capacity and specifications as per existing complete all as specified and directed by Engineer-In-Charge.
Supply only condensing coil for split air conditionner of cap 1.5 ton capacity, complete all as specified and directed by engineer-in-charge
Supply only evaporating coil for split air conditioner of cap 1.5/2 ton capacity, Complete all as specified and as directed by Engr-in-Charge.
Supply only blower motor for outdoor unit of split air conditioner of capacity 1.5 ton, specification as per existing complete all as directed by engineer-in-charge
Supply only PCB for split air conditioner of capacity 1.5/2 ton, complete all as specified and directed by engineer-in-charge .
Supply only thermostat for Split AC 1.5/2 ton as per existng make complete all as specifeid and directed.
Supply only remote control for split/window AC of existing make Complete all as specified and as directed by Engr-in-Charge.
Supply only swing motor, 230 v AC, 4-6 RPM for split/window AC of any make complete all as specfied and as directed.
Supply only micron filter suitable for 1.5/2 Ton split AC complete all as specfied and as directed.
Supply only filter strainer brass/copper for 1.5/2 ton complete all as specfied and as directed.
Supply only fan motor for indoor unit of 1.5/2 Ton split AC Complete all as specified and as directed by Engr-in-Charge.
Supply only water overflow PVC pipe heavy duty on wall/floor of size15mm dia for water drainage.
Supply only copper tubing 6mm to12 mm dia and thickness of copper tubing shall not be less than as per OEM.
Taking out and refixing at another location window type and split type AC 1.5 Ton/2 Ton including making hole in wall required size and making good disturb surface including electrical connection complete all a specified and directed.
M & L in replacement of split Air conditioner outdoor unit wall mounting stand for suitable size of 1.5/2.0 TR split AC complete all as specified.
Supply only blower motor for desert cooler 230volts, 1/5 HP , specification as per existing complete all as directed by engineer-in-charge .
Repalcement of old unsv/damage khas-khas pads for three sides, for desert cooler complete all as specified and directed by engineer-in-charge.
Supply and fixing in replacement of old worn out/rusted desert cooler body frame of size as per existing complete with bottom water tank, top with corner supports & front grill with switch control panel with wiring & switches including two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repairs side shutter as per duly painted complete all as specified and directed by Engineer in Charge .
Replacement of old unserviceable/damage submersible water pump with new submersible water pump , AC operated, single phase, capacity 1/20 HP, 240 Volts suitable for desert cooler and making necessary connection to power supply including flexible PVC tubing of required size,complete all as specified and directed by Engr-in-charge.
Replacement of old unserviceable/ damage capacitor, 4 Mfd, 50Hz, complete all as specified and as directed by Engineer-In-Charge
Supply & fix in repairs switch piano type 5 Amp, flush type, single pole complete all as specified.
Material and Labour for spray painting of Desert cooler of any Capacity & Make with one coat of synthetic paint after scraping & cleaning the surface complete as directed by Engr-in-charge.
Supply & fix fan blades (Steel) for desert cooler in replacementas per sample all as specified.
Supply & fix PVC distributorsin replacement with PVC Elbows/junction/bend for desert cooler
M&L for PVC pipe 3/8 for desert cooler in replacement complete all as directed by Engr-in-Charge.
Supply only refrigerant gas of (R 134a, R-22, R-410a ) suitable for compressor of water cooler / Refrigerator/Deep freezer and AC of any make, capacity and type complete all as specified and directed by Engineer-in-charge.
Supply & fix in replacement PVC cable flexible round/flat 3 Core Copper conductor cable 6 sqmm including taking out old unsv burnt out cable complete all as specified and directed by Engineer-in-charge.
Supply & fix in replacement PVC cable flexible round/flat 3 Core Copper conductor cable 1.5 sqmm including taking out old unsv burnt out cable complete all as specified and directed by Engineer-in-charge.
Supply & fix in replacement sheet metal powder enclosure powder coated versatile double door 2way (SPN) distribution board for MCB provisions 230Volt, 50Hz AC with neutral link , earth bar complete all as specified.
Supply & fix 3 pin Plug Top 15 Amp in replacement ISI Mark.
Supply & fix 3 pin Plug Top 5 Amp in replacement Complete all as specified and as directed by Engr-in-Charge.
Supply & fix in repair / replacement of Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 volt with output voltage stabilized at 230 v with accuracy of + 2.5 % and of cap 2 KVA having digital display to show input and output voltage Complete all as specified and as directed by Engr-in-Charge.
Supply & fix in repair / replacement of Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 volt with output voltage stabilized at 230 v with accuracy of + 2.5 % and of cap 4 KVA having digital display to show input and output voltage Complete all as specified and as directed by Engr-in-Charge.
Supply & fix in repair / replacement of Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 volt with output voltage stabilized at 230 v with accuracy of + 2.5 % and of cap 5 KVA having digital display to show input and output voltage
Supply and fix in replacement push cock/ bib cock and stop cock unserviceable/damage push cock with new push cock, chromium plated, for 15 mm bore pipe internal/external thread, suitable for water cooler of any type and any capacity, complete al as specified and as directed by Engineer-In-Charge.
Taking out old unserviceable gate valve and supply and fix new 15 mm dia bore gun metal gate valve conforming to IS with iron wheel head screwed both ends for iron pipe all as specified and directed.
Supply and fix in replacement GI pipe Medium grade galvanized of 15 mm dia bore size in any lengths laid in trenchs or laid on floors or fixed with walls with all fittings in such as tees, bend, elbows, sockets, reducer, connectors, back nuts, diminishing pieces, caps, plugs, nipples and union complete incl taking down old rusted/unserviceable pipe all as specified and directed.
M&L in replacement of old unserviceable/damage ball valve with new ball brass valves, high pressure, with polythene float and flynut, screwed for iron pioe or brass ferrule and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
Fabricated from Mild steel angle sections in replacementincluding nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified & directed.
Taking down geysers of any make & size from existing position of any height for repair, mainteance and refixing the same after neccesary repair complete all as directed. Notes (i) The defective parts to be replaced shall be measured and paid separately under relevant item of Sch . (ii) Cost of minor items i.e. Screws, nut & bolts etc shall be deemed to be included in the above item.
Supply & fix in replacement PVC connection 15 mm bore size with PTMT nuts,rubber washers etc complete of length 450 mm long complete all as specified.
Supply & fix in replacement PVC connection 15 mm bore size with PTMT nuts,rubber washers etc complete of length 600 mm long complete all as specified.
Supply & fix in replacement geyser element 2.0 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round shape/make of the geyser under repair complete all as specified.
Supply & fix in replacement geyser element 1.5 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round shape/make of the geyser under repair complete all as specified.
Supply & fix in replacement thermostat (ISI marked) suitable for existing make of the geyser under repair of cap 50/25 Ltrs complete all as specified.
Supply & fix in replacement geyser safety valve (pressure release valve) for the exsiting make & capacity of geyser complete all as specified.
M&L for painting of geysers of any cap 25/50 Ltr with 2 coats of synthetic enamelled paint after scraping the existing old painted surface complete all as directed.
Supply & fix in replacement shyphon assembly suitable for 50 ltr geysers of any make, any type complete all as specified and as directed by Engr -in-Charge.
Supply & fix in replacement shyphon assembly suitable for 25 ltr geysers of any make, any type complete all as specified and as directed by Engr -in-Charge.
Supply & fix in replacement inner tank made up of stainless steel conforming to IS suitable for 25 /35 ltr gyser vertical type including rubber gasket complete all as specified and directed.
Supply & fix in replacement inner tank made up of stainless steel conforming to IS suitable for 50 ltr gyser vertical type including rubber gasket complete all as specified and directed.
Supply & fix in replacement outer body made up of steel duly painted including base cover and indicator assembly suitable for 50 ltr gyser complete all as specified and directed.
Supply & fix in replacement outer body made up of steel duly painted including base cover and indicator assembly suitable for 25 ltr gyser complete all as specified and directed.
Supply & fix in replacement 3 Core PVC insulated PVC sheathed flexible copper wire multistranded of size 2.5 sqmm complete all as specified and directed.
Supply & fix in replacement indicator lamp any type/size 230 Volts complete all as specified and as directed.
Supply & fix in replacement of brass non-return valve 15mm dia horizontal/verticle type ISI marked complete all as specified and as directed.
Supply and fixing in replacement of metal clad plug top 20 Amps complete,all as specified and directed.
Supply and fixing in replacement of metal clad socket 20 Amps complete,all as specified and directed.
Supply and fixing in replacement of metal clad socket and plug top complete with sheet metal enclosure complete,all as specified and directed
Material and labour for repair/servicing of water filter , UF stabilized TDS controller of kent Elite MRO model through authorized service representative and replace the defective components and filter made functional,
Supply & fix in replacement membrane suitable for water filter kent complete all as specfied and as directed.
S& F in replacement candle for sedimentation filter complete all as specfied and as directed.
S &F in replacement candle for pre/ post carbon filter complete all as specfied and as directed.
Supply & fix in replacement PVC connector for filter complete all as specifed and as directed.
Supply & fix in replacement booster pump for filter complete all as specified and as directed
Supply & fix in replacement for TDS controller of filter complete all as specfed and as directed.
Repair to hot water storage tank of solar water heating system including detecting the leakage, cleaning of inner tank, bracing to leakage portion testing for leakage etc for any type, capacity of solar water heating hot water tank including removing, diamantling, assembling refixing and making water and electric connections complete,all as specified and directed.
Supply and fix in replacement of heating elements for solar water heating system 03/05 KW with rubber gasket for any type of geyser
Supply and fix in replacement of solar water steel tank cap 500 to 750 ltrs complete all as specified and directed.
Supply and fix in replacement of solar water steel tank cap 300 to 400 ltrs complete all as specified and directed.
Supply and fix in replacement of Syntex tank cap 1000 ltrs complete all as specified and directed.
Supply and fix in replacement of Syntex tank cap 500 ltrs complete all as specified and directed.
Supply and fix in replacement of GI Pipe medium grade with insulation dia 20 mm complete all as specified and directed.
Supply and fix in replacement of GI Pipe medium grade dia 20 mm complete all as specified and directed.
Supply and fix in replacement thermostat for Solar water heater, AC, SP 220 volts including making necessary connection, ISI marked, complete all as specified and as directed.
Supply and fix in replacement of temparature gauge for water heating system ISI marked, complete all as specified and as directed.
Material and labour in replacement of solar glass panel complete all as specified and directed including collant quiet, absorbing plates , flow tube , insulation coolant outlet certificate for transmissibly will be provided from approved company complete all a specified and directed.
Supply and fix in replacement modular single phase motor starter , 250V AC, 25 Amp, 2 module, panel mounting type as per existing make complete all as specifed and as directed.
M&L for replacement of geyser assembly including heating element , relay , thermostat etc complete suitable for 25 ltr cap geysers as per existing make Complete all as specified and as directed by Engr-in-Charge.
M/S MAHAJAN CONSTRUCTION CO
Bharat Builder
Chanana Engineers & Contractors
M/s. M Company
CHINAR ENGINEERS AND BUULDERS
Santokh Singh and Associates
AVTAR SINGH RAJU
Intrernational Engineers
M/s. Saffron Construction Co
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .