Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 CrAdmitted-Finance CITY TOWER BUILDING ROOM NO 306 CIRCULAR ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | NAGALAND | 797112 | ₹30.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹32.3 CrAdmitted-Finance 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | ₹32.3 Cr | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Gupta Construction L2 | M/S ALLIED CONSTRUCTION L1 |
|---|---|---|---|---|---|
| 1.00Note:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and General conditions of contracts before entry/quoting the rates. Schedule 'A' Part-I ( PRE-FABRICATED BUILDINGS) Note :- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs. 0.00" under Col - 5 signifies this fact only. | |||||
| 1.01 | Design and construction of Pre-fabricated building for OFFICE AND ADM BUILDING , Single Storey, with all fittings , fixtures etc. complete all as specified and shown in architectural drawings No. BP/2020/WD/194 Sheet 1/14 to 2/14 dated 23-06-22 and Sheet 3/14 dated 22-09-22. | 1 | Each Block | 1,78,64,450 ₹1.8 Cr | 1,49,50,000 ₹1.5 Cr |
| 1.02 | Design and construction of Pre-fabricated steel building for OFFICERS MESS for 18 Officers, Single Storey, with all fittings , fixtures etccomplete all as specified and shown in architectural drawings No. BP/2020/WD/198 Sheet 1/17 to 2/17 dated 23-06-22 and Sheet 3/17 dated 22-09-22. | 1 | Each Block | 1,57,93,900 ₹1.6 Cr | 1,50,00,000 ₹1.5 Cr |
| 1.03 | Design and construction of Pre-fabricated steel building for SINGLE LIVING ACCN FOR OFFICERS (01 COL & 01 LT COL), Single Storey, with all fittings , fixtures etc. complete all as specified and shown in architectural drawing No BP/2020/WD/203 Sheet 1/6 dated 22-09-22. | 1 | Each Block | 35,58,786 ₹35.6 L | 27,60,000 ₹27.6 L |
| 1.04 | Design and construction of Pre-fabricated steel building for SINGLE LIVING ACCN FOR OFFICERS (08 MAJ) Double Storey, with all fittings , fixtures etc.complete all as specified and shown in architectural drawings No BP/2020/WD/199 Sheet 1/11, 2/11 dated 23-06-22 & 3R/11 dated 22-09-22 | 1 | Each Block | 1,63,12,050 ₹1.6 Cr | 1,45,00,000 ₹1.4 Cr |
| 1.05 | Design and construction of Pre-fabricated steel building for SINGLE LIVING ACCN FOR OFFICERS( 07 CAPT & 01 LT), Double Storey, with all fittings , fixtures etc. complete all as specified and shown in architectural drawings No BP/2020/WD/202 Sheet 1/10 dated 23-06-22 & 2/10 dated 22-09-22. | 1 | Each Block | 1,41,09,700 ₹1.4 Cr | 1,27,50,000 ₹1.3 Cr |
| 1.06 | Design and construction of Pre-fabricated steel building of SINGLE LIVING ACCN FOR 05 HAVS & 105 ORS FOR Double Storey, with all fittings , fixtures etc. complete all as specified and shown in architectural drawings No BP/2020/WD/200 Sheet 1R/17 dated 19-09-22, Sheet 2/16 to 5/16 dated 23-06-22 6/17 dated 22-09-22, & drawing No BP/2020/WD/201 Sheet 1R/16 dated 19-09-22, 2/16 to 5/16 dated 23-06-22 & 6/17 dated 22-09-22. | 4 | Each Block | 4,26,10,250 ₹17.0 Cr | 3,90,00,000 ₹15.6 Cr |
| 1.07 | Design and construction of Pre-fabricated steel building for COOK HOUSE & DINING HALL for 10 Hav and 210 OR's Single Storey, with all fittings , fixtures etc. complete all as specified and shown in architectural drawings No BP/2020/WD/196 Sheet 1/11 to 2/11 dated 23-06-22, 3/11 dated 22-09-22, & BP/2020/WD/197 Sheet 1/12 to 2/12 dated 23-06-22 & 3/12 dated 22-09-22. | 2 | Each Block | 1,12,67,850 ₹2.3 Cr | 1,27,00,000 ₹2.5 Cr |
| 1.08 | Design and construction of Pre-fabricated steel building for ARMOUR SHOP AND ARMOURIES, Single Storey, with all fittings , fixtures etc. complete all as specified and shown in architectural drawings BP/2020/WD/195 Sheet 1/8 dated 23-06-22 & 2/8 dated 22-09-22. | 1 | Each Block | 1,05,41,550 ₹1.1 Cr | 1,10,00,000 ₹1.1 Cr |
| 1.09Note for items Sr. No. 1.01 to1.08 - Quoted amount shall be inclusive of cost of following items- 1. Design of prefabricated buildings including design of foundation. 2.Third party vetting from any IIT /NIT/Govt reputated college 3.Internal services as shown in respective architectural drawings and Sch of finishes except only item covered in Sch A part III, Part IV, Part XIII and XIV which shall be measured and paid under respective schedules. | |||||
Tender Value
₹38 Cr
EMD Value
₹15 L
Closing Date
13 Oct 2022, 6:00 pmClosed
Chief Engineer Shillong Zone
HQ Chief Engineer Shillong Zone Spread Eagle Falls Shilling 793001
PROVN OF PRE-FABRICATED SHELTERS AT UMROI MIL STN UNDER GE UMROI
2022_MES_549804_1
CESZ/UMR/ /OF 2022-23
Open Tender
Civil Works
365 days
As per tender documens
As per NIT
2 documents required · 2 mandatory
₹3,000
Yes
GE Umroi
₹15 L
Yes
19 Oct 2022
3 Sept 2022
15 Oct 2022
3 Sept 2022
13 Oct 2022
1 Oct 2022
5 Sept 2022 - 12 Sept 2022
Amount
Note:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and General conditions of contracts before entry/quoting the rates. Schedule 'A' Part-I ( PRE-FABRICATED BUILDINGS) Note :- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs. 0.00" under Col - 5 signifies this fact only.
Design and construction of Pre-fabricated building for OFFICE AND ADM BUILDING , Single Storey, with all fittings , fixtures etc. complete all as specified and shown in architectural drawings No. BP/2020/WD/194 Sheet 1/14 to 2/14 dated 23-06-22 and Sheet 3/14 dated 22-09-22.
Design and construction of Pre-fabricated steel building for OFFICERS MESS for 18 Officers, Single Storey, with all fittings , fixtures etccomplete all as specified and shown in architectural drawings No. BP/2020/WD/198 Sheet 1/17 to 2/17 dated 23-06-22 and Sheet 3/17 dated 22-09-22.
Design and construction of Pre-fabricated steel building for SINGLE LIVING ACCN FOR OFFICERS (01 COL & 01 LT COL), Single Storey, with all fittings , fixtures etc. complete all as specified and shown in architectural drawing No BP/2020/WD/203 Sheet 1/6 dated 22-09-22.
Design and construction of Pre-fabricated steel building for SINGLE LIVING ACCN FOR OFFICERS (08 MAJ) Double Storey, with all fittings , fixtures etc.complete all as specified and shown in architectural drawings No BP/2020/WD/199 Sheet 1/11, 2/11 dated 23-06-22 & 3R/11 dated 22-09-22
Design and construction of Pre-fabricated steel building for SINGLE LIVING ACCN FOR OFFICERS( 07 CAPT & 01 LT), Double Storey, with all fittings , fixtures etc. complete all as specified and shown in architectural drawings No BP/2020/WD/202 Sheet 1/10 dated 23-06-22 & 2/10 dated 22-09-22.
Design and construction of Pre-fabricated steel building of SINGLE LIVING ACCN FOR 05 HAVS & 105 ORS FOR Double Storey, with all fittings , fixtures etc. complete all as specified and shown in architectural drawings No BP/2020/WD/200 Sheet 1R/17 dated 19-09-22, Sheet 2/16 to 5/16 dated 23-06-22 6/17 dated 22-09-22, & drawing No BP/2020/WD/201 Sheet 1R/16 dated 19-09-22, 2/16 to 5/16 dated 23-06-22 & 6/17 dated 22-09-22.
Design and construction of Pre-fabricated steel building for COOK HOUSE & DINING HALL for 10 Hav and 210 OR's Single Storey, with all fittings , fixtures etc. complete all as specified and shown in architectural drawings No BP/2020/WD/196 Sheet 1/11 to 2/11 dated 23-06-22, 3/11 dated 22-09-22, & BP/2020/WD/197 Sheet 1/12 to 2/12 dated 23-06-22 & 3/12 dated 22-09-22.
Design and construction of Pre-fabricated steel building for ARMOUR SHOP AND ARMOURIES, Single Storey, with all fittings , fixtures etc. complete all as specified and shown in architectural drawings BP/2020/WD/195 Sheet 1/8 dated 23-06-22 & 2/8 dated 22-09-22.
Note for items Sr. No. 1.01 to1.08 - Quoted amount shall be inclusive of cost of following items- 1. Design of prefabricated buildings including design of foundation. 2.Third party vetting from any IIT /NIT/Govt reputated college 3.Internal services as shown in respective architectural drawings and Sch of finishes except only item covered in Sch A part III, Part IV, Part XIII and XIV which shall be measured and paid under respective schedules.
Subtotal of Sch "A' Part-I
Lumpsum price workedout by the tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule ‘A’ Part-II.
Lumpsum price workedout by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III.
Lumpsum price workedout by the tenderer for INTERNAL ELECTRIFICATIONS as listed in Schedule ‘A’ Part-IV.
Lumpsum price workedout by the tenderer for ROADS / PATH / CULVERT / PARKING AREA as listed in Schedule ‘A’ Part-V.
Lumpsum price workedout by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI.
Lumpsum price workedout by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII.
Lumpsum price workedout by the tenderer for RETAINING WALL as listed in Schedule ‘A’ Part-VIII.
Lumpsum price workedout by the tenderer for SECURITY FENCING / GATE as listed in Schedule ‘A’ Part-IX.
Lumpsum price workedout by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-X.
Lumpsum price workedout by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-XI.
Lumpsum price workedout by the tenderer for REFRIGERATION / DEEP FREEZER as listed in Schedule ‘A’ Part-XII.
Lumpsum price workedout by the tenderer for HOT WATER SUPPLY as listed in Schedule ‘A’ Part-XIII.
Sch 'A' Sec-XIV (Miscellaneous Items)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Supply and fix for 15 mm dia chromium plated health faucet complete all as specified and directed
S&F for stainless steel jet spray for EWC complete all as specified and directed
Supply, installation, testing & commissioning of heater water storage type electric geyser (vertical cylindrical type) 25 Litre capacity with BEE 5 star rating (minimum) and metallic body, porcelain enamel glass lined inner tank including fixing arrangement with providing and including suitable capacity flexible cable 3 core with 3-pin plug of 16A capacity maximum 2metre length, PVC Connection pipe of suitable length for Hot and Cold Water, fixing on Walls with and including all necessary fitting material i.e. Mild Steel Bolts (Bolts to be grouted), Nuts, Washers, etc complete all as specified and as directed.
Supply, installation, testing & commissioning of solar geyser ETC type collector connected to an insulated tank of capacity 100 liter insulated with high density injected PUF insulation with electric back up in and including all fixing arrangement of solar tank collector, water & electric connection with suitable capacity flexible cable 3 core with and all necessary water pipe connection to the system complete all as specified and as directed.
Material and Labour for painting lines, dashes, arrows etc on road using thermoplastic road mariking paint 2.5mm uniform thickness finished with glass beads (MORTH grade) white or yellow colour n. exc 100mm wide with the help of road marking machine including cleaning the surface throughly and removing all dirt complete all as specified.
Material and Labour for liquid seal coat, applying evenly binder @ 9.8 kg per 10 sqm blinding with 6.3mm size stone chippings @ 0.09 cum per l0 sqm and rolled to a uniform smooth surface complete all as specified.
Cutting of existing GI/DI/CI pipes of size 150 mm bore in position for taking out branch connection and including one number DI Tee of size 150 mm x 150 mm x 100 mm and connected to pipe including jointing material and necessary earthwork in any types of soil, complete all as specified and directed.
Supply, laying and jointing of ductile iron pipes with spigot and socket ends conforming to IS 8329 : 2000, suitable for push on rubber joint centrifugally cast, class (K-7), inner side cement lining and outer side black bitumen coating and any length, laid in trenches of 100mm bore pipe and including push on rubber (EPDM) ring with ISI marked complete all as specified complete.
Supply and fixing of 50 mm cast iron air release valve conforming to IS 14845, with drilled flanged ends, pressure rating (PN-1) and tamper proof with two air outlets with nuts, bolts and washers including fixing up in DI pipe of size 100 mm dia complete all as specified and directed.
Construction of VALVE PIT TYPE 'A' of PCC block Masonry and of size 60 cm x 60 cm x 60 cm (inner dimension) with all fittings and fixtures complete all as specified and shown on drawing No. TD/EM/6 Sheet 1/2
Construction of VALVE PIT TYPE 'A' of PCC block Masonry and of size 90 cm x 90 cm x 90 cm (inner dimension) with all fittings and fixtures complete all as specified and shown on drawing No. TD/EM/6 Sheet 1/2
Supply and laying for sub class 'B' brick (designated 75) laid in trenches across the trench as cable protection complete all as specified and directed
Supply and fix cable route indicator oval shaped size 200x150x6mm thick CI/MS with letter embosed as HT/LT UG cable fixed on 25x25x6mm MS angle iron of 50cm long embaded in PCC (1:3:6) type C1 using 20mm stone aggregate including two coats of red oxide primer on exposed complete all as specified and as directed.
Material and labour for expulsion fuse assembly single pole vertically mounted on MS channel 11000 volts grade above 25A & upto 50 Amps capacity including making connections with HT cables/GOD with provision of jumper suitable crimped/fixed with appropriate size of lugs/connectors all as specified and as directed.
M&L for Lightening arrestor single pole zinc oxide (gap less) surge type heavy duty complete with all fittings, station class, discharge capacity 10 KA for 11 KV, 50 Hz conforming to IS :3070, 1993 complete all as specified.
Supply and fixing cable Junction box of size 167x125x82 mm IP 65 made of impact resistance plastic & heat resistant materials including MCB SP 6A- 01 No, terminal of suitable capacity and fixing to the street light pole with suitable sizes of clamps, nuts and bolts all as specified. mounted on DIN rail and connecting all the incoming and outgoing cable teminals with lugs complete all as specified.
Supply and fixing for LED street light fitting 60 watt including pressure die cast RAPTOR NEO street lights are aerodynamically designed for all weather Conditions with excellent thermal management, made with pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection. Efficacy ≥ 110LPW10KV SPD Included (60/70SL) aluminium housing, heat resistance glass, with IP 65 including wiring with 1.5 sqmm PVC insulated unsheathed multistranded copper conductor FRLS including PVC pipe medium grade 20mm dia for wiring from junction/terminal box to light fitting and GI pipe bracket of size 40mm light grade of 1.5 mtr long, bend to shape including 2 Nos clamps, nuts, bolts & washer of suitable size including two coats of aluminium paint over a coat of red oxide zinc chrome primer and testing on completion, complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in gound (earth pit not less than 2.25m deep below normal ground level) with top edge plate not less than 1.5m deep below normal ground level connected to galvanized steel iron earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers made of glavanized iron,20mm dia GI pipe (med grade) for watering, 15mm dia GI pipe (light grade) for protection of earth lead wire,including necesary earth work in any type of soil, PCC (1:3:6) Type C1 concerete pit, RCC (1:1.5:3) type A1 precast cover (54 x 54 x 5cm) duly reinforced with including 8mm dia TMT bar @ 150mm c/c both ways, one lifting handle made of 8mm dia TMT bar, embebed in precast cover slab complete all as specified and shown in electrical plate No 3 of SSR Part-I including testing on completion.
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI strip 32 x 6mm as earthing lead connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layers complete as shown in electrical plate No. 3 of SSR Part-I all as specified and directed by Engr-in-Charge.
Supply, install, testing and commissioning of outdoor distribution transformer step down with necessary provision of wheel and channel, copper wounded having primary side for 11KV & secondary for 433 Volt, 3 phase, 50 hz capacity of 250 KVA with the following specification :- (i) No load voltage ratio-11/0.433 KV (ii) Nos of phase- Three (iii) Type of cooling-ONAN (iv) Frequency-50 hz (v) Vector group-DYN 11 (vi) Two earthing terminals for body earthing and two additional for neutral rought out on a bushing. (vii) Oil level gauge indicating oil level minimum and maximum. (viii) Lifting lugs. (ix) Rating and terminal marking plates. (x) Dehydrating breathing device which would not permit ingress of moisture, rain water and insects. (xi) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug (xii) Thermometer pocket (for transformers of rating above 25 KVA). (xiii) Oil filling hole (1-1/4" Nominal size thread) with cover (xiv) Connection- Delta/Star (xv) Temperature rise in oil-45 deg Centigrade (xvi) Temperature rise in winding- 55 deg Centigrade. (xvii) Material winding-Copper wound (xviii) High voltage/low voltage-Bushing with box.
Supply, installation, testing and commissioning CPRI approved outdoor type LT feeder pillar box of suitable size, pedestal mounted factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15mm thick CRCA sheet, base frame with 50x50x6 mm thick MS angle iron and legs of size 0.9m long, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external sufaces with approved powder coated paint including mounting on PCC platform made out of PCC 1:3:6, 100mm thick all round the panel board and suitable for 500 volts, 50 Hz, 3 phase 4 wire system including the following accessories complete housed in :- BUSBAR :- 500 Amps rated copper bus bar TPN duly insulated with coloured PVC sleev as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (square/round) insulators of suitable size and good insulation resistance. (Incoming) (a) MCCB AC 415 volts, 50 Hz, 4 pole 320 Amps current rating, 50 KA rupturing capacity, Ics = 100% Icu, with thermal magnetic release - 01 No (b) LCD Multifunction meter-01 No (c) Current Transformer 400/5A range - 03 Nos (d) Indicator lamp LED type R-Y-B - 01 Set (e) Copper control internal wiring for measuring instrument & indiator (Outgoing) (a) MCCB AC 415 volts, 50 Hz, 4 pole 200 Amps current rating, 35 KA rupturing capacity, Ics = 100% Icu, with thermal magnetic release - 01 Nos (b) MCCB AC 415 volts, 50 Hz, 4 pole 160 Amps current rating, 35 KA rupturing capacity, Ics = 100% Icu, with thermal magnetic release - 02 Nos
Supply, installation, testing and commissioning CPRI approved outdoor type LT feeder pillar box of suitable size, pedestal mounted factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15mm thick CRCA sheet, base frame with 50x50x6 mm thick MS angle iron and legs of size 0.9m long, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external sufaces with approved powder coated paint including mounting on PCC platform made out of PCC 1:3:6, 100mm thick all round the panel board and suitable for 500 volts, 50 Hz, 3 phase 4 wire system including the following accessories complete housed in :- BUSBAR :- 300 Amps rated copper bus bar TPN duly insulated with coloured PVC sleev as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (square/round) insulators of suitable size and good insulation resistance. (Incoming) (a) MCCB AC 415 volts, 50 Hz, 4 pole 200 Amps current rating, 35 KA rupturing capacity, Ics = 100% Icu, with thermal magnetic release - 01 Nos (b) LCD Multifunction meter - 01 No (c) Current Transformer 200/5A range - 03 Nos (d) Indicator lamp LED type R-Y-B - 01 Set (e) Copper control internal wiring for measuring instrument & indiator (Outgoing) (a) MCCB AC 415 volts, 50 Hz, 4 pole 63 Amps current rating, 18 KA rupturing capacity, Ics = 100% Icu, with thermal magnetic release - 02 Nos (b) MCCB AC 415 volts, 50 Hz, 4 pole 40 Amps current rating, 18 KA rupturing capacity, Ics = 100% Icu, with thermal magnetic release - 02 Nos
ITEM NO 14.23 CONT.... (c) MCCB AC 415 volts, 50 Hz, 4 pole 25 Amps current rating, 18 KA rupturing capacity, Ics = 100% Icu, with thermal magnetic release - 01 No (d) MCB Double Pole 'C' Curve 10A, 240V AC, 10 KA - 02 Nos (e) Three pole Power contactor 25A & Digital timer switch single phase 240V AC - 01 each
Supply, installation, testing and commissioning CPRI approved outdoor type LT feeder pillar box of suitable size, pedestal mounted factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15mm thick CRCA sheet, base frame with 50x50x6 mm thick MS angle iron and legs of size 0.9m long, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external sufaces with approved powder coated paint including mounting on PCC platform made out of PCC 1:3:6, 100mm thick all round the panel board and suitable for 500 volts, 50 Hz, 3 phase 4 wire system including the following accessories complete housed in :- BUSBAR :- 250 Amps rated copper bus bar TPN duly insulated with coloured PVC sleev as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (square/round) insulators of suitable size and good insulation resistance. (Incoming) (a) MCCB AC 415 volts, 50 Hz, 4 pole 160 Amps current rating, 35 KA rupturing capacity, Ics = 100% Icu, with thermal magnetic release - 01 Nos (b) LCD Multifunction meter - 01 No (c) Current Transformer 200/5A range - 03 Nos (d) Indicator lamp LED type R-Y-B - 01 Set (e) Copper control internal wiring for measuring instrument & indiator (Outgoing) (a) MCCB AC 415 volts, 50 Hz, 4 pole 40 Amps current rating, 18 KA rupturing capacity, Ics = 100% Icu, with thermal magnetic release - 04 Nos (b) MCCB AC 415 volts, 50 Hz, 4 pole 32 Amps current rating, 18 KA rupturing capacity, Ics = 100% Icu, with thermal magnetic release - 02 Nos (c) Provision for accommodating 02 Nos MCCB in future.
M & L for PVC conduit Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit pipe medium grade of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One light/fan/Bell point controlled by one,one way switch all as specified and as directed
M & L for conduit Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit pipe medium grade of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly forOne light point controlled by two,two way switch 6 A all as specified and as directed
M & L for conduit Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit pipe medium grade of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches, socket, regulators etc complete including FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One socket outlet point 6 A on independent board all as specified and as directed
M & L for conduit point wiring with 4.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit pipe medium grade of adequate size with all fittings and accessories including mild steel terminal boxes with laminated sheet for mounting switches & socket, including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 04 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one 16 Amp socket outlet on independent board all as specified and as directed
M & L for conduit Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit pipe medium grade of adequate size with all fittings and accessories excluding mild steel terminal box with cover plate for mounting switches, sockets, regurator etc complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One light/fan/Bell point controlled by one,one way switch all as specified and as directed
M & L for conduit Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit pipe medium grade of adequate size with all fittings and accessories excluding mild steel terminal box with cover plate for mounting switches, sockets, regurator etc complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One socket outlet point 6 A on independent board all as specified and as directed
M & L for conduit Point wiring with 1.5 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit pipe medium grade of adequate size with all fittings and accessories excluding mild steel terminal box with cover plate for mounting switches, sockets, regurator etc complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for One light pint controlled by two,two way switch 6 A all as specified and as directed
M & L for Modular conduit point wiring with 4.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multi stranded copper conductor single core cable drawn through and including non-metallic rigid PVC conduit pipe medium grade of adequate size with all fittings and accessories excluding mild steel terminal box with cover plate for mounting switches, sockets, regurator etc complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 04 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly for one 16 Amp socket outlet on independent board. all as specified and as directed
S & F Modular Blank plate 1 module suitable for Modular switch boards all as specified and as directed
S & F modular blank metal flush box 8 Module all as specified
S & F Modular blank metal flush box 6 modules
S & F Modular blank metal flush box 4 modules
S & F Modular blank metal flush box 3 modules
S & F Modular blank metal flush box 2 modules
S & F Modular blank metal flush box 1 modules
S & F modular cover plate with Frame 8 Module all as specified
S & F modular cover plate with Frame 6 Module all as specified
S & F modular cover plate with Frame 4 Module all as specified
S & F modular cover plate with Frame 3 Module all as specified
S & F modular cover plate with Frame 2 Module all as specified
S & F modular cover plate with Frame 1 Module all as specified
M & L for Sub main Wiring with two run of 6.0 Sqmm (nominal cross-sectional area) FRLSH PVC insulated & unsheathed 1100 volts grade multistranded copper conductor single core cable drawn through and including PVC conduit pipe medium grade of adequates size and fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLSH PVC insulated & unsheathed single core multistranded copper conductor cable of size 6.0 Sqmm green in colour as earth continuity conductor connected to common earth and earth dolly complete all as specified and directed.
Supply and fixing Exhaust fan 230/225 mm sweep PVC body AC single phase 230V with self closing louvers, electrically connecting with twisted three core PVC insulated unsheated flexible cord of 0.70 Sqmm copper conductor cable from ceiling rose to Exhaust fan complete all as specified and directed.
Supply, installation, testing and commissioning refrigerator of capacity 308 ltr/ nearest available capacity, frost free, multi flow type with separate chill compartment with plastic shelves, ice maker unit vegetable/ fruit drawer, colour body as approved with suitable locking arrangement working on Non-CFC eco friendly refrigerant gas with 5 star energy rating suitable for single phase, 230 V system all as specified and as directed.
Supply, installation, testing and commissioning refrigerator of capacity 394 ltr/ nearest available capacity, frost free, multi flow type with separate chill compartment with plastic shelves, ice maker unit vegetable/ fruit drawer, colour body as approved with suitable locking arrangement working on Non-CFC eco friendly refrigerant gas with 5 star energy rating suitable for single phase, 230 V system all as specified and as directed.
Construction of Brick Masonry SOAK WELL OF SIZE 2.40 M DIA & 3.00 M DEPTH with all fittings and fixtures complete all as specified and shown on drawing No TD/SZ/502 Sheet 1R/1
Construction of Brick Masonry SOAK WELL OF SIZE 3.00 M DIA & 4.50 M DEPTH with all fittings and fixtures complete all as specified and shown on drawing No. TD/SZ/502 Sheet 1R/1
Construction of Steel gate 5.50m wide & 2.1m height with RCC pillar complete all as specified and shown on drawing No. CESZ/2017/TD/34 Sheet 1/3 to 3/3
Construction of Steel wicket gate 1.20m wide & 2.1 m height with RCC pillar complete all as specified and shown on drawing No. CESZ/2017/TD/34 Sheet 1/3 to 3/3
Supply and erect/construction of LLDPE modular Vertical /Horizontal Septic Tank 30 users capacity, made out of polyethylene resins, designed to carry sewage and sludge water complete all as specified
RCC Septic tank 100 users with upflow filter type designated to carry sewage and sullage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design mix in walls, base slab, baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc, complete with effective depth 1.5 mtr and over all depth of 3 mtr for all as specified
Switch socket combination 2 in 1, 5 Pin, 6 Amps flush type, 230 V (ISI marked) complete all as specified.
Switch socket combination 2 in 1, 6 Pin, 6 and 16 Amps flush type, universal 230 V (ISI marked) complete all as specified.
Supply & fixing Sluice valve cast iron body class PN 1.6 with flanged ends drilled suitable for bore of pipe 100mm ISI marked having brass spindle with iron wheel at top including necessary fixing arrangements such as Mild Steel Nuts, Bolts, Washers, Gaskets, etc. including testing, complete all as specified and as directed.
M&L for hilti M-16 anchor bolt of dia 16w/150mm and length of bolt as per site requirement complete all as specified and as directed.
Supply and Fix Sheet metal enclosure DB TPN 415 Volts 12 Way double door glazed type with 200 Amps rated bus bar for fixing MCB complete all as specified and as directed.
Supply and Fix Sheet metal enclosure DB TPN 415 Volts 4 Way double door glazed type with 200 Amps rated bus bar for fixing MCB complete all as specified and as directed.
Supply and Fix Sheet metal enclosure DB SPN 240 Volts 8 Way double door glazed type with 200 Amps rated bus bar for fixing MCB complete all as specified and as directed.
Material and labour for prepainted chequered cement concrete tiles 30cmX30cmX25mm thick with mixture of white & grey cement in equal proportions & no pigments, set jointed and pointed in neat cement slurry complete all as specified and as directed.
Felling of tree exc. 30 cm and n exc. 100 cm girth including cutting of trunk, and branches and stacking of serviceable material and disposal of unserviceable material to a distance n exc. 100 m and clearing site complete all as specified and as directed. Note: Each cut tree shall be done in pieces of 2.5 Mtr to 3 Mtr length and stack at a distance not exceeding 100 Mtr from the construction site as directed by Engr-in-Charge. The cost of this is deemed to be included in this item and nothing Extra shall be Paid to the Contractor by the Department.
M/s Gupta Construction
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.27 MB
Td8.pdf
Additional Documents • 5.12 MB
MD.pdf
Additional Documents • 9.16 MB
TD1.pdf
Additional Documents • 21.53 MB
TD2.pdf
Additional Documents • 24.83 MB
TD3.pdf
Additional Documents • 28.39 MB
TD4.pdf
Additional Documents • 12.61 MB
TD5.pdf
Additional Documents • 7.34 MB
TENDER.pdf
Tender Documents • 16.67 MB
TD6.pdf
Additional Documents • 20.71 MB
TD7.pdf
Additional Documents • 26.52 MB
BOQ_614913.xls
BOQ • 0.62 MB
Download all tender documents and submit your bid