Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC P O PURUWALA TEHSIL PAONTA SAHIB DISTT SIRMOUR 173025 H P | PAONTA SAHIB | SIRMOUR | HIMACHAL PRADESH | 173025 | ₹2.9 L Quoted ₹3.0 L | L1 | Accepted-AOC Awarded to L1 |
| 2 | L2₹3.1 LRejected-Finance | ₹3.1 L | L2 | Rejected-Finance L2 |
| 3 | L3₹3.1 LRejected-Finance VILL KAGAR PO BAGTHAN TEHSIL PACHHAD HIMACHAL PRADESH | ₹3.1 L | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical 1301 3 SHASTRI NAGAR MEERUT U P 250004 | MEERUT | UTTAR PRADESH | 250004 | - | - | Rejected-Technical as requested by contractor |
| Sl No | Description | Qty | Unit | Budh Raj Singh L1 | Chaman Lal Electrical and Hardware Contractor L3 | Veena Devi L2 |
|---|---|---|---|---|---|---|
| 1.00O&M of GPH/ R/m of 6.6 S/stn Gumma | ||||||
| 1.01 | Repair and Servicing of Air Circuit Breaker 2 Nos i,e Distribution transformer supply and station transformer supply Air Circuit Breaker . Specification :- Make -SIEMENS AIR CIRCUIT BREAKER 3WE 48
800A , 660V 50Hz (P2 Category) 415- 500- 660V
I Break 50 50 45Ka RMS
I Make 110 110 95Ka PEAK
1 sec withstand =50Ka RMS
Complete inspection, servicing, testing and replacement of defective components with new one such as protection relay, spring charging motor, closing coil and shunt trip coil, Ampere meter and Voltmeter along with cleaning and calibration of the breaker mechanism to ensure reliable operation alongwith testing and commissioning of Air Circuit Breaker to ensure proper functioning.
All works will be carried out by qualified technical personnel using suitable tools and standard procedures . | 1 | Job | 24,500 ₹2.0 L | 24,600 ₹2.0 L | 24,560 ₹2.0 L |
| 1.02 | Checking of wiring of MCCB and Replacement of defective indication lamp with new LED Indication Lamp 130-230 volt, 2.6 watt ( Red, yellow, Blue ) of MCCB of various capacity in service board . | 1 | Job | 1,910 ₹15,469.80 | 1,930 ₹15,729.40 | 1,930 ₹15,705.80 |
| 1.03 | Providing and fixing of spring charge motor 220 volt DC of VCB OF Machine-1 along with testing to ensure proper functioning
Specification
Make – ROTOMAKE
Model – SS-VCB-220
1.4 Ampere
250 W
2600 rpm
CLS- FS2-10 min. | 1 | Job | 7,740 ₹62,823.20 | 7,760 ₹64,085.80 | 7,760 ₹63,035.60 |
| 1.04 | Providing and fixing of push button of VCB (S&S Make). With assembly Green and Red of 5 nos VCB. As per sample alongwith testing to ensure proper functioning.
Any extra material if required will be provided by contractor | 1 | Job | 3,800 ₹31,329 | 3,900 ₹32,096 | 3,880 ₹31,517.80 |
Tender Value
₹2.5 L
EMD Value
₹2,500
Closing Date
17 Apr 2026, 11:00 amClosed
RE Andhra
Resident Engineer, AndhraPower House Division, HPSEBL, Chirgaon, Distt.ShimlaHP-171208
Repair and servicing of Air Circuit Breaker , replacement of defective indication lamp of MCCB, OF 2X1.50 MW Gumma Power House .Providing and Fixing of spring charge motor of VCB and providing and fixing of push button of VCB of Sub Stn Gumma
2026_HPSEB_133354_1
APHD/2026-27-01
Open Tender
Electrical Works
30 days
Chirgaon
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
Yes
₹2,500
Yes
22 Apr 2026
4 Apr 2026
17 Apr 2026
4 Apr 2026
17 Apr 2026
4 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
O&M of GPH/ R/m of 6.6 S/stn Gumma | - | - | - | - | BI01010001010000000000000515BI0100001112 | |
| 1.01 | Repair and Servicing of Air Circuit Breaker 2 Nos i,e Distribution transformer supply and station transformer supply Air Circuit Breaker . Specification :- Make -SIEMENS AIR CIRCUIT BREAKER 3WE 48
800A , 660V 50Hz (P2 Category) 415- 500- 660V
I Break 50 50 45Ka RMS
I Make 110 110 95Ka PEAK
1 sec withstand =50Ka RMS
Complete inspection, servicing, testing and replacement of defective components with new one such as protection relay, spring charging motor, closing coil and shunt trip coil, Ampere meter and Voltmeter along with cleaning and calibration of the breaker mechanism to ensure reliable operation alongwith testing and commissioning of Air Circuit Breaker to ensure proper functioning.
All works will be carried out by qualified technical personnel using suitable tools and standard procedures . | 1 | Job | - | - | - |
| 1.02 | Checking of wiring of MCCB and Replacement of defective indication lamp with new LED Indication Lamp 130-230 volt, 2.6 watt ( Red, yellow, Blue ) of MCCB of various capacity in service board . | 1 | Job | - | - | - |
| 1.03 | Providing and fixing of spring charge motor 220 volt DC of VCB OF Machine-1 along with testing to ensure proper functioning
Specification
Make – ROTOMAKE
Model – SS-VCB-220
1.4 Ampere
250 W
2600 rpm
CLS- FS2-10 min. | 1 | Job | - | - | - |
| 1.04 | Providing and fixing of push button of VCB (S&S Make). With assembly Green and Red of 5 nos VCB. As per sample alongwith testing to ensure proper functioning.
Any extra material if required will be provided by contractor | 1 | Job | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.11 MB
vol-I.pdf
Tender Documents • 2.39 MB
Vol-II.pdf
Tender Documents • 1.52 MB
BOQ_197197.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid