Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹48.8 LAccepted-AOC | L 1 | Accepted-AOC L1 BIDDER | |
| 2 | L 2₹49.1 L+₹21,300 (0.44%)Rejected-AOC | L 2 | Rejected-AOC OTHER THAN L1 | |
| 3 | L 3₹52.5 L+₹3.6 L (7.38%)Rejected-AOC 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L 3 | Rejected-AOC OTHER THAN L1 |
Tender Value
₹44.9 L
EMD Value
₹89,700
Closing Date
22 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh. Rahul Meena, IDSE, EE, Garrison Engineer, CEA
GARRISON ENGINEER KASAULI, DISTT SOLAN (HP) PIN 173204 PH 01792273107
PROVN OF CERTAIN SANCTIONED WORKS AT KASAULI and DAGSHAI UNDER GE KASAULI
2023_MES_611792_4
GEK-70/2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
kasauli and dagshai udner ge kasauli
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE KASAULI
₹89,700
Yes
11 Dec 2023
31 Oct 2023
25 Nov 2023
31 Oct 2023
22 Nov 2023
8 Nov 2023
Amount
Schedule 'A' Section - I
M & L for point wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC conduit concealed in wall of conduit size 20mm with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing sunken boxes for mounting of switch, socket etc complete all as specified and directed for the following :-
One Light/Fan/Bell point controlled by one, one way switch 6 Amp complete
One switch socket outlet 3 pin, 5 Amp on the independed board
One switch socket outlet 3 pin, 5 Amp on same board
Ditto all as per item No 1.02 above but with 2.5 Sqmm cross sectional area electric cable for 15 Amp socket outlet on independent board, complete all as specified and directed.
All as per item No 2.00 but point wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 Sqmm (Nominal area) drawn in and including PVC conduit concealed in wall of any type of conduit size 20mm with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly for one 16 Amps socket (Power) point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket etc complete all as specified and directed.
M & L in replacement sub main wiring with single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC conduit concealed in wall of any type of conduit size 25 mm with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces etc after incl down unsv if reqd all as specified and directed.
S & F switch piano flush button single pole one way, 6 Amps, 240 Volt complete all as per specified and directed.
S & F socket outlet 2-in-1 5 pin, 6 Amps flush type complete all as specified and as directed.
S & F in replacemnt ceiling rose surface, backelite, three terminal, 240 volts complete all as specified and directed.
S&F in replacement switch piano flush button single pole one way, 16 Amps, 230/240 V complete all as specifed and directed
S&F in replacement socket outlet 2-in-1 5 pin, 6 & 16 Amps flush type complete all as specified and as directed.
S & F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engg-in-Charge.
Supply & fixing in repair LED tube light batten fitting 18/20W, (single Side Connection) including LED Rod including all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply & fixing/fixing in repair LED mirror light 10W including rod complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F Surface mounted LED bulk head 10 watt luminaire with ABS body & polycarbonate diffuser IP 65 including connecting to ceiling rose with 0.5 sqmm two core copper flexible conductor cable fixed in repair incl lamp incl taking down unsv complete all as per specified and directed.
S&F self ballasted LED Retrofit Bulb 5 Star Bulbs 12 Watt with PBT body shell and PC diffuser. 210 digree wide distruction CCT 6500K, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL/LED Bulb complete all as specified and as directed.
Supply & fix 15mm dia PVC connection with brass chrome plated nuts 900 mm long , suitable for hot water supply ,complete with 2 Nos brass nuts complete all as specified and directed.
Supply & fix 15mm dia PVC connection with brass chrome plated nuts 900 mm long , suitable for cold water supply ,complete with 2 Nos brass nuts complete all as specified and directed.
Supply and fix electric water heater (geyser),storage type steel body with copper inner tank and heating element upto 2KW capacity 25 litre, BEE 5 star rated complete with al accessories such as safety valve, thermostate,NRV, connection piece etc.
Taking out old unsv and S&F Exhaust Fan 300mm Sweep Metal body, 1500 RPM including cutting hole of suitable size in wall and making good the disturbed surfaces to match the existing, complete all as specified and directed.
S&F Recess mounting ceiling fitting 2'X2' LED 36/40 Watt light Edgelit slim panel having white powder coated extruded aluminium body with high quality LPG and PMMA diffuser. Separate HPF driver. Suitable for Armstrong and Grid ceiling, PF min 0.95 complete all as specified and as directed
S&F MCB DB SPN 8 way double door, IP 42, CRCA sheet powder coated factory made suitable for incorporating MCB as out going connecting incoming and outgoing cables & blaking plate as required incl taking out existing unsv DB of any size and making good disturbed surface to match with existing incl taking down unsv complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs/MCCBs will be done with suitable thimble).
S&F MCB SPN 32 Amp to 40 Amp, 10 KA, 240 volts, IS/IEC 60898-1, 'B' curve complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs will be done with suitable thimble).
S&F MCB SP 6 Amp to 32 Amp 10 KA, 240 volts, IS/IEC 60898-1, 'B' curve complete all as specified and as directed. (Note :- Connection of cable in the DB Boxes/MCBs will be done with suitable thimble).
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium, conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 Sq. mm x 2 Core nominal cross section in service connections complete all as per specifed and directed.
DETAILS SPECIFICATION SERVO CONTROLLED VOLTAGE STABILIZER :- (a) Technology -. - Servo controlled (b) Type - 3 Ph, Indoor, Un balanced. (c) Input voltage - 340 V to 480 V AC, 3 Ph. (d) Output voltage - 415 ± 1%, 50 Hz, 3 Ph, 4 Wire. (e) Cooling - Oil cooled. (f) Insulation Class - A (g) Temperature rise - 50ᴼC in oil. (h) Efficiency - 98.5-99% at full load at unity power factor. (j) Control. - Auto / Manual (k) Waveform Distortion - NIL (l) Back up protection - Suitable MCCB at I/P. (m) Indications - LED for each Phase to indicate mains ON, Output ON, Under voltage, Over voltage, Overload, Single Phasing & Trip.
DETAILS SPECIFICATION SERVO CONTROLLED VOLTAGE STABILIZER :- (Contd....) (n) Winding - Copper. (o) Response Time - Less than 8V / Sec per Phase. (p) Trip - Incorporated by means of contactor to trip in event of under voltage, Over voltage, Overload, Single Phasing alongwith audio alarm. (q) Metering - Digital Microprocessor Based Cards for voltage, Output load current with CT. (r) Protections - Overload, Short Circuit, High/Low Voltage cut off & Bypass arrangement to be provided. (s) Oil - First filling of oil to be provided. (t) Ref Standard - IS 9815 (u) Fittings - Four Plain Rollers, Two Earthing Terminals, Four Lifting Hooks, Oil filling hole with cap, drain wall, oil level indicator, Sillica Gel breather, Oil temperature indicator, Thermometer pocket. (v) Testing - All routine tests as per DGAQA & IS to be conducted & Test reports to be furnished along with equipment.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium, conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 25 Sq. mm x 3.5 Core nominal cross section in service connections complete all as per specifed and directed.
Supply, installation, commissioning and testing of Diesel Engine driven factory assembled, floor mounted ,silent type diesel generating set of capacity 30 KVA output at NTP with AMF control panel, 3 phase, 4 wire, 50 Hz, 415 Volts 1500 RPM power factor of 0.8, as per IS 10001/10002 complete with safety contact and metering equipment mounted on common base frame on PCC platform with anti-vibration pads as recommended by manufacturer including inbuilt type Manual Control Panel from DG set manufacturer’s with all fixing arrangement complete all as specified, directed and comprising the following:- NOTE:- Later any price varitaion due to change in government policy, No extra payment will be done by department.
PRIME MOVER : Prime mover directly coupled with water cooled engine suitable rated matching BHP but not less than 40 BHP for driving 30 KVA (24 KW) capacity alternator, 1500 RPM , electric-start four stroke diesel engine confirming to ISO -3046/ BS- 5514 and IS 10001/10002 for continuous running and capable for taking 10% over load for one hour for every 12 hours with the following accessories:-
Cooling sytem
Heavy duty Radiator Cooled
Engine Mounted water pump
Thermostat
Coolant
Self contained piping
Fuel system
High pressure common rail fuel system
Spin on type fuel filter
Self contained piping
Lubrication System
Lube Oil pump
spin on type Lube Oil filter
Self contained piping
Air Intake system
Dry type replaceable paper element Air Filter
Air Intake Manifold with necessary connections
Turbo charger
Exhaust system
Exhaust Manifold
Flexible piping
Silencer Hospital Grade
Governing System
Power Command (PC) Microprocessor based Controller system
Starting System
DC starter
Battery Charging Alternator
Inbuilt regulator
Other System
Fly wheel with fly wheel housing
Any other items required for functional requirement as per OEM
ALTERNATOR : Alternator 30 KVA at 0.8 Power factor self regulated three phase 4 wire system with neutral, 415 volts, 50 Hz, 1500 RPM conforming to BS 2613 or BS 5000/IS-4722 complete with automatic voltage regulator to give rated output at NTP conditions. (i) The alternator shall be self excited, self regulated, self ventilated in brushless design, provided with suitable automatic voltage regulator and shall conform to BS 2613 or BS 5000. Alternator foot mounted fitted with ball or roller bearing including making cable connections. The alternator shall be suitable for tropical climatic condition of Kasauli. The excitation system consists of an electronic automatic regulator having very fast response to load changes. The silent features of alternator are:- (i) (+) or (-) 1% voltage regulation under static conditions. (ii) Class H insulation. (iii) Permanently lubricating bearing. (iv) 10% over load allowed for one hour for every 12 hour. (v) Copper winding with Star connection (all six leads shall be brought out of stator frame).
Control Panel with AMF Panel :- Control Panel shall be made of CRCA sheet of suitable gauge and powder coated for weather proof and long lasting finish. The control panel shall consist of the following features:- (i) Microprocessor based control panel for generator set monitoring, metering and control system with LCD display designed to meet the demands of engine driven DG sets having Digital AVR, electronic governing with temp compensation, start/stop, Engine Metering Oil pressure, coolant temp, battery voltage, engine speed and AC alternator metering L-L Voltage, L-N voltage, current, Volt-Ampere, frequency. Engine protection:- low lube oil pressure, High/Low coolant temp, over speed, battery over/under/waek volts fail to crank/start, sensor failure.AC alternator Protector:- over/under voltage, over/under frequency, over current, short circuit and loss of AC sensing and also having Data logging history of engine etc with protection against phase sequence, phase missing & earth fault tripping complete. (ii) Aluminium Bus Bar of Suitable rating with incommimg/ outgoing terminals. (iii) Indication Lamps for load ON and set Running. (iv) MCCBs of suitable rating with overload and short circuit protections. (v) Contactor of suitable rating with control wiring including all metering accessories complete.
ACOUSTIC ENCLOSURE : Floor mounted Accoustic enclosure (canopy) suitable for 30 KVA DG set as per CPCB norms of the same make as that of DG set to be provided with following provisions/ specifications:- (i) The accoustic enclosure is made from CRCA sheet of suitable gauge and specially designed to meet stringent CPCB norms of 75dBA @ 1Mtr at 75% load under free field condition. (ii) The sheet metal components are Hot dip not less than seven tank pretreatment process. (iii) It is purepolyster based powder coated(inside as well as outside). All nuts / bolts / hardware are zinc coated. (iv) Baterry is accommodated in a tray inside the enclosure. (v) The doors are fitted with gasket with high quality EPON gasket to avoid leakage of sound. (vi) Sound proofing of enclosure is done with high density fire retardant PU foam conforming to IS 8183.
ACOUSTIC ENCLOSURE : Contd... (vii) Hospital Grade silencer shall be provided within enclosure to control exhaust noise. (viii) Adequate ventilation shall be provided to meet requirement for combustion and heat removal. If required a blower shall be used to meet total air requirement and air changes. (ix) Temperature of enclosure does not exceed beyond 50 degree C of ambient temperature. (x) Enclosure shall be provided with 'High enclosure temperature safety device'. (xi) There shall be provision of emergency shut down from outside the enclosure. (xii) There is arrangement of proper illumination inside the canopy. (xiii) Enclosure is provided Air inlet louvers,drains for lube oil/ fuel, fuel filling arrangement etc. (xiv) Two point for lifting for easy handling.
(i) Maintenance free sealed lead acid battery of appropiate AH and volts as per OEM recommendation along with all accessories along with battery lead copper, connector with in built trolley for battery. (ii) Starter motor (iii) Starter gearing (iv) Start/Stop push button (v) Invertor cum battery charger 500 VA capacity suitable to work on 230 volts 50 Hz AC supply system for charging of DG set batteries externally when DG set is in off position (vi) Alternator/Dynamo of suitable capacity to charge the battteries while DG set running complete with cut out all as per manufacturer's recommendation .
Daily services fuel tank in built type suitable for full load running of DG set for min 8 hours enclosed within the canopy all as per CPCB norms with level indicator inlet, outlet, drain plug, air vent and locking arrangement etc including fuel pipe connections etc complete.
Standard safety device and self starter having 12 volts DC
Heavy duty base frame of sturdy design made of MS stud with necessary reinforcement and lifting arrangements.
Sets of AVM pads between the engine alternator feet and the base frame as per OEM.
Exhaust system shall be provided with thermal insulation by using fire retardant / non igniting foam conforming to ISO 3046/ BS-5514 to prevent excess heat radiation on the engine and safety of operator including flexible coupling with guards.
Tools:- Following set of tools shall be provided alongwith DG Set and the cost of the same shall deemed to be included in the unit rate quoted for DG set:- (i) Set of DE spanner – 6 – 32 mm - 1 set (ii) Insulated cutting plier 250mm - 1 No (iii) Ring spanner 300mm - 1 No (iv) Screw driver set - 1 No (v) Ring spanner set (Ratchet type) – 6mm to 32mm - 1 Set of 10. (vii) Allen key set - 1 Set (1.5mm to 10mm) (viii) Cell tester - 1 No (ix) Hydrometer - 1 No (x) Tool box-01 No (xi) Rotary type fuel pump-01 No
Note:- (i) The engine of DG set shall be suitably designed to give output of 30 KVA at NTP including 10% overload. (ii) The quoted rate for DG set is inclusive of PCC foundation. The foundation for DG set shall be made of PCC as per OEM recommedations. The size of platform shall be as per manufacturers recommondations complete all as specified and directed. (iii) The DHPP (fuel) required for testing of DG set shall be arranged by the contractor and the cost of the same shall deemed to be included in the unit rate quoted for DG set. (iv) DG Set shall be composite type with Control panel, Prime mover, alternator and allied accesories in one enclosure.
Disconnecting the electrical cable connections of existing 10 KVA DG Set along with AMF panel after dismantling carefully of DG set and AMF panel from Dagshai Mil station (Near AL 08) complete and transporting the same to the MES GE Kasauli office and make provision of PCC platform of dimension as required and installed again as per OEM recommendation with making connections to the existing panel for street lights compete all as specified and as directed. Note : (a) No extra payment will be made for PCC platform and fixing of cables used for connection. (b) Any damage to the equipment will be make good to the satisfaction of Engg-in charge without any extra cost. (c) Earthing will be paid separately.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in hard/dense soil for stay assembly/laying of cable/erection of poles etc, complete all as specified and directed by Engr-in-charge.
Returning, filling of hard/dense soil including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engr-in-charge.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-charge.
M & L for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 10.0 Sqmm x 4 core with required aluminium cable lugs complete all as specified and directed by Engr-in-charge.
S & F GI tubing light grade 50mm bore, ISI marked, for cable protection at road crossingcomplete all as specified and directed by Engr-in-charge.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-charge.
M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (11.0 metres long) complete all as specified and directed by Engr-in-charge. (Note : PCC work for erection of poles with PCC 1:3:6 mix, type D-2, using 40 mm graded stone aggregate as in foundation, filling and mass concrete and PCC 1:2:4 mix, type B-1, using 20 mm graded stone aggregate as in copings to be done and cost for the same shall be included in the quoted rate of item itself).
M & L for sub main wiring with 2 x 2.5 Sqmm nominal cross sectional area (two single core cable of 2.5 Sqmm for Phase and neutral + 01 single core cable of 2.5 Sqmm for earth wire), 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including steel conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth in the junction box and making connections upto street light fittings complete all as specified and directed by Engr-in-charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engr-in-charge. Note - The units rate includes the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 20mm GI pipe (light grade) for watering & 40mm GI protection pipe (medium grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
S & F Security light Bracket made out of galvanised steel light grade pipe of 40mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos mild steel clamp 50mm x 50mm and 04 sets of nuts, bolts and washers painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
S & F Street light junction box of size 200mm x 140mm x 95mm outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable/wire complete comprising with the followings :- (a) Bus bar with two aluminium strips, 63 Amps capacity, insulated with insulators, with colour coding, incl PVC cable of suitable size from bus bar to MCB (b) MCB SPN 5 to 30 Amps - 01 No (c) Clamps made out of 25mm x 3mm flat iron duly welded with nuts & bolts complete all as specified and directed by Engr-in-charge.
DETAILS SPECIFICATION SERVO CONTROLLED VOLTAGE STABILIZER :- (a) Technology -. - Servo controlled (b) Type - 3 Ph, Indoor, Un balanced. (c) Input voltage - 300 V to 480 V AC, 3 Ph. (d) Output voltage - 415 ± 1%, 50 Hz, 3 Ph, 4 Wire. (e) Cooling - Oil cooled. (f) Insulation Class - A (g) Temperature rise - 50ᴼC in oil. (h) Efficiency - 98.5-99% at full load at unity power factor. (j) Control. - Auto / Manual (k) Waveform Distortion - NIL (l) Back up protection - Suitable MCCB at I/P.
DETAILS SPECIFICATION SERVO CONTROLLED VOLTAGE STABILIZER :- Contd... (m) Indications - LED for each Phase to indicate mains ON, Output ON, Under voltage, Over voltage, Overload, Single Phasing & Trip. (n) Winding - Copper. (o) Response Time - Less than 8V / Sec per Phase. (p) Trip - Incorporated by means of contactor to trip in event of under voltage, Over voltage, Overload, Single Phasing alongwith audio alarm. (q) Metering - Digital Microprocessor Based Cards for voltage, Output load current with CT. (r) Protections - Overload, Short Circuit, High/Low Voltage cut off & Bypass arrangement to be provided. (s) Oil - First filling of oil to be provided. (t) Ref Standard - IS 9815 (u) Fittings - Four Plain Rollers, Two Earthing Terminals, Four Lifting Hooks, Oil filling hole with cap, drain wall, oil level indicator, Sillica Gel breather, Oil temperature indicator, Thermometer pocket. (v) Testing - All routine tests as per DGAQA & IS to be conducted & Test reports to be furnished along with equipment.
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 40mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed by Engr-in-charge. Note : The units rate includes the cost of excavation & earth work in any type of soil charcoal & salt in altemate layers, 20mm GI Pipe (light grade) for watering 40mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium, conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 70 Sq. mm x 3.5 Core nominal cross section in service connections complete all as per specifed and directed.
S&F HDPE (DWC) duct pipe 40 mm outer dia confirming to IS: 14930 (Part-II) of approved colour with all accessories, bends, joints, nuts, bolts, clamps etc fittings for cable protection complete all as specified and directed.
Supply and fixing H beam pole 150 mm x 150 mm of 14 mtr height (weight = 37 kg per RM) complete all as specified and directed by Engr-in-charge.
Supply and fix Stay assembly complete comprising of MS galvanised stay plate 23 cm x 23 cm x 6 mm, MS galvanised stay bow 40 cm long with 2 nos galvanised thimbles with and including all fittings and accessories as shown in electrical plate No. 1 complete all as specified and directed by Engr-in-charge. (loop type insulator, stay clamps, excavation and concrete measured separately)
M&L for ACSR conductor including jointing with existing conductor and stringing on pole and proper fastening to insulators with aluminium binding wires and required jumpering connection complete all as specified and directed by Engr-in-charge.
M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (11.0 metres long) complete all as specified and directed by Engr-in-charge.
S & F Loop type insulator, vitreous porcelain, white, brown or green Large size, with overall dimensions 140mm, clearance of hole 25.5mm complete all as specified and directed by Engr-in-charge.
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engr-in-charge.
M & L for Air termination, single pointed aluminum rod 12 mm dia and 300 mm long laying at proper distance as specified and directed incl all cutting /welding complete all as specified and directed by Engr-in-charge.
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25 mm, drilled and screwed including 3 Nos. 8 mm dia 25 mm long hex. Head screw and MS cover made of 2mm thick sheet including provision for entry/exit of earth strip complete all as specified and directed by Engr-in-charge.
M & L for PCC 1:3:6 mix, type D-2, using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed by Engr-in-charge.
M & L for PCC 1:2:4 mix, type B-1, using 20 mm graded stone aggregate as in bed blocks/copings, etc complete all as specified and directed by Engr-in-charge.
Excavation in trenches n exc 1.5 mtr wide and n exc 3.0 mtr in depth and getting out in soft/ loose soil for erection of poles, etc, complete all as specified and directed by Engr-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed by Engr-in-charge.
M & L for Aluminum strip of size 25 x 3.15 mm with saddles from above test point to Air Termination rods inter connections including brazing for joints copper/brass nuts , bolts /washers with insulators for necessary fixing on wall/laid on roof conductors and down conductors above ground complete all as specified and directed by Engr-in-charge.
M & L for Galvanised iron strip of size 32 x 6 mm for earth continuity from test point to aluminium conductors above for inter connections including brazing for joints copper/brass nuts, bolys/ washers with insulators for necessary fixing on wall/trenches etccomplete all as specified and directed by Engr-in-charge.
Demolition of Cement concrete of any description and in any position not otherwise specifically provided for in landing and shelves etc complete all as specified.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting ou and getting out in soft /loose soil
M&L for PCC (1:4:8 ) type- D2 (using 40mm graded aggregate) in foundation filling and mass concrete incl necessary form work.
M&L Mild steel TMT bars 10mm dia and over cut to length bend to shape as required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips .
M&L Mild steel TMT bars 6 to 8 mm dia cut to length bend to shape as required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
M&L for reinforcement cement concrete Nominal Mix Type B1 1:2:4 (20 mm graded aggregate) as in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M&L reinforcement cement concrete Nominal Mix Type B1 1:2:4 (20 mm graded aggregate) as incolumns, pillars, piers, posts and struts complete all as specified and directed.
M&L reinforcement cement concrete Nominal Mix Type B1 1:2:4 (20 mm graded aggregate) as in Beams, cantilevers,bressummers, lintels over1.5m span
M&L for form work to flat rough finish side of concrete foundations, footings, beses of columns, raft and raft beams, sides and soffit (if any) of foundation and plinth beams, and similar work, vertical or to batter flat fair finished surface of concrete complete all as specified and directed.
M&L for form work to flat rough finish sides of Square, rectangularpillars, posts, struts, piers, columns and stanchions of fair finished square, rectangular surface complete all as specified and directed.
M&L for Formwork to flat rough finish sides and soffits of floor or roof beams, beam haunch ings, lintels, cantilevers, shelves including sup- ports, overhangs, etc.
Provding cement concrete type B-1 1:2:4 (20mm graded agg) as in coping,weathering slightly rounded or chamfered angle throating etc incl necessary form work.
M&L for Brick work with old size subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6
M&L for Brick work with old size subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4.
M&L for rendering 10 mm thick on brick masonry surface or surface other than fair face of brick-work in 1:6 and finished even and smooth with out using extra cement
M&L two coat cement plaster ,first coat 10mm thick CM 1:6 and second coat cement plaster 5mm thick in CM 1:4 with WPC finished even and smooth without using extra cement. (WPC will be paid seperately under respective item)
Supply only WPC
M&L for preparation of plastered or unplastered new surfaces of walls of and applying two coat of cement base paint over a coat of cement priming coat of any approved tint complete all as specified & as directed.
Preperation of newly plastered surfaces of wall & applying two coat of oil bound distemper over one coat of chalk whiting complete all as specified and directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface
M&L PCC 75mm thick 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of flooring all as specified and directed.
S & F coloured Glazed ceramic tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in CM 1:3, complete all as specified.
M & L Non-Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer in CM 1:4 for laying glazed tiles in floors etc. , complete all as specified complete all as specified and as directed .
Steel work in tubular trusses ,purlin including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240
M&L for rolled mild steel section as in roof trusses (framed), trusses, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats gusset plate etc.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Ditto but fixing only.
S&F for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/clading to wall, fixed with self tapping screws as specified.
Dismantling timber scantlings in unframed works 40sq. cm and over in section, in any position.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed .
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified.
M & L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 as in retaining wall ,parapet wall etc complete all as specified and directed
-ditto- as abve but except stone
Taking down chowkats or frames without taking down shutters from the frame n exc. 1.5 sq. m each complete all as specified.
Taking down chowkats or frames without taking down shutters from the frame exc. 1.5 sq. m but n.exc.4 sqm each complete all as specified.
M&L 2nd class H/W, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed.
Supply and Fixing 35mm thick, 2nd class HW, Plain framed, factory made panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and as directed .
Supply and Fixing 30mm thick 2nd class hardwood, factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.20 (b) complete all as specified and as directed .
Supply and fixing for butt hinge ISI Marked 100mm size, medium weight, cold rolled mild steel complete all as specified and as directed.
S&F 300mm Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled of drawn brass bolts and fixed complete all as specified & directed.
S&F for wall mounted Health faucet of stainless steel body and exceeding 1 mtr long cromium plated spiral cord and wall hook complete all as specified and directed.
S&F for Vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe),including plastic water closet seat, black, closed pattern with flat bottom and seat cover, and mild steel chromium plated or aluminised/ hinging device complete all as specified.
S&F of Vitreous china squatting pan, "Orissa pattern" of size 680 x 470 mm white with integral foot rests(excluding flushing cistern, flush pipe and waste pipe), cast iron P or S trap including provision of cement concrete (1:5:10) type E2 with stone aggregate for setting the trap & pan,complete all as specified
S & F for 10 litre PVC valveless, syphonic action type,dual flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed .
S&F for Wash basins with pedestal, vitreous China, colour, (flat back angle back type) size 550x400mm including cutting for and pinning in ends of bracket erecting stand but exclusive of fixing of supply and waste pipe, complete all as specified and directed.
S&F for 15mm bore CP fancy type brass bib taps cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule and fixed (weight not less than 400gms).
S&F for 15mm dia Swan neck Pillar taps, cast copper alloy, with capstan heads,chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe and fixed
S&F Mild steel work for framed work such as grills, (12mm sqm bars for window / ventilators for guard bars) grating, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
S & F 4 mm thick frosted on one side sheet glass ordinary quality and glazing with oil putty or wooden beads in square area not exc. 0.5 Sqm in each pane complete all as specified.
S&F Factory made solid PVC frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with mild steel square tube, suppling and fixing in opening as per specificaiton and drawing.
M&L for factory made solid panel PVC moulded door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes fot top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC 'C channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either siude & as gap insert for top rail, lock rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
Supply and fixing for stainless steel butt hinge ISI Marked 75mm size, medium weight, cold rolled mild steel complete all as specified and as directed.
S&F 200mm Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed as in repair including taking down the unserviceable existing tower bolt complete all directed.
M&L for mirror polished Machine cut kota stone slab flooring 18-20 mm thick size not less then 550X550 mm over 15mm thick screed in CM(1:4) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.
M&L Kota stone slab 12-15 mm thick mirror polished in skirting, steps riser etc over 15mm thick plater in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.
Material and Labour for preparing new wood surfaces of any description, not otherwise descri-bed, over 10cm in width or girth, & applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified
M & L Coloured Prepolished chequered cement conc tiles (30cmx30cmx25mm thick) in white cement and pigment in floors etc , set and jointed in neat cement slurry, over and including 20mm thick screed bed in cement mortar 1:4 complete all as specified.
Demolition of wall ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs blankets any thickness including cover fillets, complete all as specified and directed.
M&L Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately)
S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed screwed bothe ends, each screwed end to be fitted with washers and one hexagonal or square nut diameter of neck 5 to 10 mm exc 5 cm and n exc 10 cm long complete all as specified and directed
M&L for Excavating in post holes (in Soft/loose soil) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm.
Supply and Fixing in repair of 150mm Extruded brass handles, fabricated type polished complete all as specified and as directed .
S&F 15mm dia tubes medium grade gavanised with all fittings and fixed coplete to walls and ceiling or laid in floors complete incl the holes in walls and floors shall be bade by drilling with drill or jumper and not by dismantling the brick/concrete. After fixing holes shall be made good with CM 1:3 properly
Cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, cutting n exc 10cm girth. pinning in, making good to facings where required and pointing in CM 1:3 on stone walls.
S&F 20mm dia tubes medium grade gavanised with all fittings and fixed complete to walls and ceiling or laid in floors complete incl the holes in walls and floors shall be bade by drilling with drill or jumper and not by dismantling the brick/concrete. After fixing holes shall be made good with CM 1:3 properly.
S&F 15mm bore stop cock CP fancy type with butter fly handle, screwed down, high pressure for iron pipes or for unions fixed in repairs (weight not less than 400gms).
S&F 15mm bore PVC connection with brass nut of length 450mm fixed as in repairs including taking out the existing unserviceable complete all as specified and as directed.
S&F Wash hand basin mixture cast copper alloy, with capstan heads, chromium plated, screwd down high pressure, with lettered 'hot' or 'cold' with long screwed shanks and fly-nuts, screwed for iron pipes and fixed in repairs.
S&F of Mixer 15 mm dia Brass CP Wall mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified.
S&F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
S&F 20mm bore Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed.
M & L for 500 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by the Engineer-in-Charge
S&F of oval shape Wash basins with waste pipe and coupling size 560x410mm including cutting of RCC slab and granite complete all as specified and directed.
Supply and fixed 18-20 mm thick Granite of any shade ( table rubbed and polished ) in steps, jambs, pillars, windowcills, cooking plateforms and like in cement mortor 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match shade of the slabs etc all as specified and directed.
M & L 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified
S & F 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed .
S & F 75mm bore PVC (SWR) pipes single socketed in any length by using necessary clamps fixed in trenches complete all as specified and as directed .
S & F 75mm bore PVC (SWR) bends any radius complete all as specified and as directed .
S & F 100mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement
Material and Labour for preparing new steel surface of any description, over 10cm in width or girth,not otherwise described & applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified
S&F for Vitreous China half stall urinals,complete including providing and fixing plugs, bedding urinal against wall in cement mortar1:2, securing urinal to plugs with and including coupling,waste pipe,Urinal spreader of PTMT and 60mm long brass screws, pointing around urinal back in cement
Dismentling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified
Amount of credit of Rs. 12800.50 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
Rajesh Agencies
Bairagi Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .