Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹64.9 L+₹6.8 L (11.7%)Rejected-AOC H M APARTMENT 4C S J ROAD ATHGAON GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-AOC L2 | |
| 3 | L3₹69.0 L+₹10.9 L (18.7%)Rejected-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L3 | Rejected-AOC L3 | |
| 4 | L4₹73.6 L+₹15.5 L (26.6%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹74.5 L+₹16.3 L (28.1%)Rejected-AOC SHREE KUNJ HOUSE NO 22B JIBAN KRISHNA PATH NEAR L P SCHOOL HENGRABARI GUWAHATI PIN 781036 | GUWAHATI | KAMRUP | ASSAM | 781036 | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
14 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Borjhar
Commander Works Engineers AF Military Engineer Services Borjhar PO Borjhar Airport Guwahati 15 Assam Pin 781015 Tele 0361 2841626
WORK SERVICES FOR SHIFTING OF ELECTRIC MAIN PANEL AT AF STN BORJHAR (2ND CALL)
2021_MES_451320_2
CWE(AF)/BOR/TOKEN-14 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Borjhar
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE AF Borjhar
₹1.6 L
Yes
13 Oct 2021
26 Aug 2021
16 Sept 2021
26 Aug 2021
14 Sept 2021
30 Aug 2021
60 days
Amount
SCHEDULE 'A' PART-I (B/R PORTION)
Material and labour for taking down old out dated indoor type panel board including disconnection and PCC work complete as as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out in soft / loose soil complete all as specified and directed.
Material and labour for sand cushioning (dry) in trenches for protection of UG cable 8 cm thick before laying the cable and 15 cm thick after laying and stretching the cable as mechanical protection complete all as specified and directed (Note : Punned thickness shall be measured & paid).
Supply and laying old size sub class 'B' bricks well burnt, best quality locally available, of size 230x115x75mm, laid flat with width equal to length of the brick in trenches over sand cushioning for UG cable protection complete all as specified and directed
Re-laying only old brick, in trenches for UG cable protection (Serviceable brickes obtained from taking down of cable shall be used ), laid flat with width equal to length of the brick in trenches complete all as specified and directed.
Returning, filling in including, spreading, levelling, watering and well ramming in layers not exceeding 250 mm in soft/ loose soil complete all as specified and directed.
Removing excavated materials (soils) to a distance not exceeding 50.00 m and depositing where directed at a level not exc 1.50 m above the starting point in soil, complete all as specified and as directed.
Taking down existing, galvanized steel tubing 40/50 mm bore of any grade in trenches or fixed to poles/ walls etc including all fittings complete all as specified and directed
Supply, fixing, testing and commissioning 200 Amps capacity MCCB 4 pole adjustable type of breaking capacity 36 KA suitable for MCCB DB complete all as specified and directed.
Supply, fixing, testing and commissioning 150 Amps capacity MCCB 4 pole adjustable type of breaking capacity 36 KA suitable for MCCB DB complete all as specified and directed.
Material and labour for Factory made precast cement concrete cable route indicator of size 150 x 50 x 600mm for UG cable including duly engraved with symbol HT/LT and necessary excavation & earth work complete all as specified and directed by Eng-in-Charge.
Taking down existing, galvanized steel tubing 80 mm bore, of any grade, in trenches or fixed to poles/ walls etc including all fittings complete all as specified and directed
Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with standard aluminium conductor 1100 volts grade of cross sectional area 6 Sqmm 2 core, laid in trenches/duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc including taking out old unserviceable cable complete alongwith bricks and stacking aside all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately)
Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with standard aluminium conductor 1100 volts grade grade of cross sectional area 10 Sqmm 2 core, laid in trenches/ duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc including taking out old cable alongwith bricks and stacking aside complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately)
Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with standard aluminium conductor 1100 volts grade of cross sectional area 16 Sqmm 2 core, laid in trenches/ duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc including taking out the old unserviceable cable alongwith bricks and stacking aside complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately)
Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with standard aluminium conductor 1100 volts grade of cross sectional area 10 Sqmm 4 core, laid in trenches/ duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc including taking out the old unserviceable cable alongwith bricks and stacking aside complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately)
Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heave duty electric power cable with standard aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 4 core, laid in trenches/ duct/ on pole including all necessary fixing arrangment such as lugs, glands end termination etc including taking out old unserviceable cable alongwith bricks and stacking aside complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately)
Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with standard aluminium conductor 1100 volts grade of cross sectional area 25 Sqmm 4 core, laid in trenches/ duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc including taking out old unserviceable cable alongwith bricks and stacking aside complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately)
Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with standard aluminium conductor 1100 volts grade of cross sectional area 35 Sqmm 3.5 core , laid in trenches/ duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc including taking out old unserviceable cable alongwith bricks and stacking aside complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid seperately)
Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with standard aluminium conductor 1100 volts grade of cross sectional area 50 Sqmm 3.5 core, laid in trenches/ duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc including taking out old unserviceable cable alongwith bricks and stacking aside complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately)
Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with standard aluminium conductor 1100 volts grade of cross sectional area 70 Sqmm 3.5 core, laid in trenches/ duct/ on pole including all necessary fixing arrangment such as lugs, glands end termination etc including taking out old unserviceable cable alongwith bricks and stacking aside complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately)
Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with standard aluminium conductor 1100 volts grade of cross sectional area 95 Sqmm 3.5 core, laid in trenches/ duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc including taking out old unserviceable cable alongwith bricks and stacking aside complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately)
Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with standard aluminium conductor 1100 volts grade cross sectional area 120 Sqmm 3.5 core, laid in trenches/ duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc including taking out old unserviceable cable alongwith bricks and stacking aside complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately)
Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with standard aluminium conductor 1100 volts grade of cross sectional area 185 Sqmm 3.5 core, laid in trenches/ duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc including taking out old unserviceable cable alongwith bricks and stacking aside complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid seperately).
Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with standard aluminium conductor 1100 volts grade of cross sectional area 240 Sqmm 3.5 core, laid in trenches/ duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc including taking out old unserviceable cable alongwith bricks and stacking aside complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately)
Material and labour submain wiring with two single core PVC insulated unsheathed stranded copper conductor cable 4 sqmm (nominal area) drawing through and including PVC casing caping and 2.5 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly complete all as specified and directed. (Note :- 2 x 4 Sqmm + 1 x 4 Sqmm including casing caping shall be measured and paid as one unit)
Material and labour submain wiring with two single core PVC insulated unsheathed stranded copper conductor cable 6 sqmm (nominal area) drawing through and including PVC casing caping (ISI marked) and 6 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly complete all as specified and directed. (Note :- 2 x 6 Sqmm + 1 x 6 Sqmm including casing caping shall be measured and paid as one unit)
Material and labour submain wiring with two single core PVC insulated unsheathed stranded copper conductor cable 10 sqmm (nominal area) drawing through and including PVC casing caping (ISI marked) and 10 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly complete all as specified and directed. (Note :- 2 x 10 Sqmm + 1 x 10 Sqmm including casing caping shall be measured and paid as one unit)
Material and labour submain wiring with two single core PVC insulated unsheathed stranded copper conductor cable 10 sqmm (nominal area) drawing through and including stove enamelled black MS conduit (ISI marked) with accessories and 10 sqmm stranded copper conductor cablle PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly complete all as specified and directed. (Note :- 2 x 10 Sqmm + 1 x 10 Sqmm including MS condiut and accessories shall be measured and paid as one unit)
Material and labour submain wiring with two single core PVC insulated unsheathed stranded copper conductor cable 16 sqmm (nominal area) drawing through and including stove enamelled black MS conduit (ISI marked) with accessories and 16 sqmm stranded copper conductor cablle PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly complete all as specified and directed. (Note :- 2 x 16 Sqmm + 1 x 16 Sqmm including MS condiut and accessories shall be measured and paid as one unit)
Material and labour submain wiring with two single core PVC insulated unsheathed stranded copper conductor cable 25 sqmm (nominal area) drawing through and including stove enamelled black MS conduit (ISI marked) with accessories and 25 sqmm stranded copper conductor cablle PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly complete all as specified and directed. (Note :- 2 x 25 Sqmm + 1 x 25 Sqmm including MS condiut and accessories shall be measured and paid as one unit)
Supply and fixing MCB DB TPN 415 volt with 200 Amps bus bar and double door 8 Way complete all specifiled and direced
Supply and fixing MCB DB TPN 415 volt with 200 Amps bus bar and double door 4 Way complete all specifiled and direced
Supply and fixing cable jointing kit for 1100 volt (Earthed) grade cable for end termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/ 4 core XLPE armoured aluminium conductor cable of size 70 to 150 sqmm complete all as specified and directed.
Supply and laying/ fixing as per site requirement GI pipe 50 mm bore light grade for protection of UG cable with all accessories (clamps, nutbolt etc) complete all as specified and directed
Supply and laying/ fixing as per site requirement GI pipe 40 mm bore light grade for protection of UG cable with all accessories (clamps, nutbolt etc) complete all as specified and directed
Supply and laying/ fixing as per site requirement GI pipe 80 mm bore light grade for protection of UG cable with all accessories (clamps, nutbolt etc) complete all as specified and directed
Supply and fixing of electrozinc galvanized wiremesh cable tray with wire dia from 3.9 mm to 5.9 mm for differenct size of trays including support. It shall be manufactured with a longitudinal T welded safety edge. Tray shall be constructed with 50mm/100mm match configuration. Accessories for coupling and making T's and bends CE25/ CE30 screw based system combination must be used and mounting accessories are required of same finish of same manufacturer as per the site requirement (Ceiling/ Wall mounted). The deflection of cable tray must be within 1/200- th of the distance between to supports and tested in accordance with the standard IEC 61537. Wire cable tray must be designed with an optimum span of 1.5 mtr, taking into account maximum load carrying capacity as authorised by the manufacturer. Assembly with E30/ E90 certificate the loading capacities of the brackets and the hanger torques must be tested accordance with the standard IEC 61537. No hot work for trays is allowed at site. Make : LEGRAND (CABLOFIL)/ COPE/ LEVITON/ PANDUIT.
Supply and fixing copper strip 32 mm x 6 mm thick buried in ground/ wall/ ceiling and roof of the hanger including suitable size of insulator with nuts, bolts and washers complete all as specified and directed by Engr-in-Charge.
Material and labour for boring holes under road, pavement, hard standing by trenchesless technology using ultra sounding technique and neccessary machine including HDPE pipe of 150 mm bore suitable for 0.4 mpa working pressure complete all as specified and directed by Engr-in-Charge.
Supply and fixing aluminium strip 32 mm x 3 mm thick complete with saddles and fixing screws for fitting the strip complete all as specified and directed
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded 10 Sqmm copper conductor served with innner sheathing of PVC tape and overall PVC sheathed for service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm dia suspension wire one twin core cable flat or circular including taking out old existing unserviceable one complete all as specified and directed.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded 6 Sqmm copper conductor served with innner sheathing of PVC tape and overall PVC sheathed for service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm dia suspension wire one twin core cable flat or circular including taking out old existing unserviceable one complete all as specified and directed.
Material and labour for chemical earthing complete with copper plate electrode of size 90 cm x 60 cm x 5 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 m below normal ground level connected to copper earth strip 50 x 6 mm, all as shown on electrical plate No 3 of SSR Part-I, using 5 Nos alternate layers of charcol, common salt and salt crystal additionally mixing magnesium sulphate of 50 Kg in the soil and connected to earth test point including 25 mm bore GI medium grade pipe for watering with funnel and wire mesh and 63 mm bore GI light grade pipe for protection of earth strip and providing water supply connection from nearest water supply point and testing including PCC chamber complete all as specified and as directed. Note :- (i) The unit rate shall deemed to include for earth work in hard/ dense soil, PCC (1:2:4) type B-1 chamber, RCC (1:1.5:3) cover 50 mm thick reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways, funnel with watering pipe 25 mm bore medium grade, GI protection pipe light grade 63 mm bore and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub-heading earthing, specified on SSR Part-II. (ii) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on GI plate above 45 cm from GL as per colour code followed in AF Station. (iii) If the desired earth resistance is not achieved during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissible. (iv) Copper strip shall be provided upto earth test points as directed.
Material and labour for earthing complete with copper earth plate electrode of size 600 mm x 600 mm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of plate not less than 1.5 m below normal ground level connected to copper earth strip of size 25 x 3 mm as earthing lead by means of nut, bolts and washers made out of galvanised iron and 40 mm bore GI pipe "light grade" for protection of earth lead and connected to control board or main switch or as directed by Eng-in-Charge including earthing pit in PCC (1:3:6) type C-1, pre-cast RCC 1:1.5:3 cover slab of size 300 x 300 x 100 mm reinforced with 8 mm dia TMT bars @ 150 mm c/c and one handle made out of 8 mm dia round bar, 20 mm bore GI pipe medium grade for watering, funnels, wire mesh and provided charcoal and common salt in alternate layers of 15 cm thick including necessary earth work complete all as shown in electrical plate No 3 of SSR Part I and testing complete all as specified and as directed. Note :- (i) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on GI plate above 45 cm from GL as per colour code followed in AF Station. (ii) If the desired earth resistance is not achieved during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable.
M/S. SUBHAS CONSTRUCTION CO.
PURBANCHAL BUILDERS
M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS
M/S PRASANTA MAHANTA
M/s. GAURAV ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .