Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | L2₹11.0 L+₹1.2 L (12.8%)Rejected-Finance | L2 | Rejected-Finance Not a lowest bid | |
| 3 | L3₹11.0 L+₹1.3 L (13.6%)Rejected-Finance | L3 | Rejected-Finance Not a lowest bid | |
| 4 | L4₹11.9 L+₹2.2 L (22.2%)Rejected-Finance SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L4 | Rejected-Finance Not a lowest bid |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
16 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE MCEME SECUNDERABAD
GE MCEME SECUNDERABAD MCEME CAMPUS TRIMULGHERRY SECUNDERABAD 500015
CLEANING AND REPAIRS TO SEWAGE LINE SEPTIC TANKS AND SOAKAGE PITS AT ZONE I AREA UNDER GE MCEME SECUNDERABAD
2020_MES_371175_1
GE/MCEME/11 OF 2020-2021
Open Tender
Civil Works
Item Rate
330 days
SECUNDERABAD
as per NIT
7 documents required · 7 mandatory
₹500
GE MCEME SECUNDERABAD
₹29,000
Yes
23 Oct 2020
21 Aug 2020
18 Sept 2020
21 Aug 2020
16 Sept 2020
1 Sept 2020
60 days
Amount
Cutting/ cleaning of tree branches, bushes and vegetation etc around septic tank & for sewage line if required complete all as specified.
Mechanically pumping out sewage water / sludges from Septic Tanks / Soak Wells / Sumps etc., of any size / dia by means of mechanical operated equipment / trolley mounted Browsers duly taking all precautionary measures and removing sludge / water out side and away from the MD land (working on foul condition) complete all as specified and directed.
Labour only for cleaning of filter media material from filter bed of any size and depth incl bailing out water, removing the filter media out of septic tanks scarifying, washing and screening to sizes as directed and loose filling back in the filter bed old materials complete as directed.
Supply and loose filling with broken stone aggregate of gauge 40 to 80mm as filter media in filter beds, soak pits etc all as specified and directed.
Supply and loose filling with broken stone aggregate of gauge 20mm as filter media in filter beds, soak pits etc all as specified and directed.
Supply and loose filling with broken stone aggregate of gauge 12.50mm as filter media in filter beds, soak pits etc all as specified and directed.
Demolition and breaking up of drain pipes (Salt glazed ware, AC or Reinforced concrete) of 100mm internal dia set in cement mortar complete all as specified and as directed.
Description all as per Item No. 7 above but pipes of 150/200mm internal dia.
S&F 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, laid in trenches or in floors incl taking down existing unsv pipe.
All as per item No. 9 above but fixed to walls.
S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors incl taking down existing unsv pipe .
All as per item No. 11 above but fixed to wall
Excavation in trenches not exc. 1.5 mtr wide and n.exc. 1.5 mtr in depth for foundations, manholes, laying of sewage lines etc., n.exc. 10Sqm on plan and getting out in hard/dense soil complete all as specified and as directed by Engineer-in-Charge.
Description all as per Item No. 13 above but depth exc. 1.5m and n.exc. 3 mtr.
M&L for 100 mm dia pipe (Grade ‘A’ pipe) Salt glazed stone ware drain pipes laid in trenches and jointed in CM 1:1 complete all as specified and as directed.
Description all as per Item No. 15 above but pipes of 150mm bore.
M & L RCC drain pipes of 200mm bore, class NP2, with collars laid and jointed, laid in tenches and jointed in CM 1:1 complete all as specified and as directed.
M&L for PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) concrete bed to drain pipes of 100/110 mm dia, including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified.
Description all as per Item No. 18 above but PCC bed for pipes of 150mm bore.
Description all as per Item No. 18 above but PCC bed for pipes of 200mm bore.
Returning, filling in with approved soil obtained from excavation including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removal of excavated surplus soil to a distance not exc 50m away and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry built in Cement Mortar including all quoins, arches, pillars etc complete all as directed.
M&L Brick work with Fly ash bricks (old size bricks) straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls,etc. including raking out joints, hacking for keys scrubbing down with water etc., complete all as specified and as directed.
M & L for Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified and as directed.
S&F in repairs PVC(SWR) bend/shoe with access door for 110 mm dia complete.
S&F in repairs PVC(SWR) bend/shoe with access door for 75 mm dia complete.
S&F in repairs PVC (SWR) vent cowl for 75 mm dia complete.
S&F in repairs PVC (SWR) vent cowl for 110 mm dia complete.
S&F in repairs PVC(SWR) bend/shoe for 75 mm dia , any radius complete.
S&F in repairs PVC(SWR) bend/shoe for 110 mm dia , any radius complete.
Cutting holes into or through brick walls built in cement mortar for removing/ refixing PVC/CI fittings and making good in CM 1:3 or PCC 1:2:4 Type B-1 as required, superficial area n exc 150 sq cm each
M&L in repairs salt glazed stone ware gully traps square or rounded mouthed type 'P' of size 150x150mm fixed in cement concrete complete
Demolition of cement concrete(un-reinforced) in floors and paving n'exc 15cm thickness below or above ground floor complete all as specified and as directed.
M&L for PCC 1:4:8, type D2 using 40mm graded stone aggregate as in foundations, mass concrete , filling etc., complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in surface drain/ benching for manholes, haunching around manhole frame for setting etc including weathering, slightly rounded or chamfered angles and throating and including necessary form work complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in copings, including weathering, slightly rounded or chamfered angles and throating and including necessary form work complete all as specified and as directed.
Demolition of RCC work of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for Mild steel TMT bars 6 to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips all as specified.
M&L for precast cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate), as in manhole cover slabs etc including necessary form work and set in CM 1:4, complete all as specified and as directed. Note:- Reinforcement will be measured and paid separately
S&F in repairs Cast iron Nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), Diameter of outlet in 75mm, etc complete all as specifed and directed.
M&L 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection, finished even and smooth w/o using extra cement complete all as specified and as directed
Cleaning / clearing of all blockages of any type in entire zone I MCEME area in sewage lines such as in Gully/Floor traps, inspection chamber and from 1st manhole to branch sewer line, main sewer line, manholes of any size and depth and desludging completely including foreign materials manually or mechanically or by way of any other suitable means and rodding with 6mm dia MS round bars / plain flexible Bamboo pieces tied with protective cushion / waste cloth on top till clearing the sewer lines between the blocked manholes and keeping the sewage line all time functional upto septic tank or central sewage treatment plant and / or soakage well complete (working in foul condition with taking suitable precautionary measures). The sludge obtained from the manholes and sewage line shall be removed to out side and away from MD land.
Note for Item No. 44 : Note 1 : Contractor will deploy 2 Nos sweeper and 2 Nos helper per day in the MES Office / Complaint cell and they will report to the concerned JE / Engr-in-Charge daily at 9.00 AM to 5.00 PM. Note 2 : If any of the sweeper / helper fails to report daily to the concerned authority, a sum of Rs. 696/- will be deducted per men/day from the payment of the contractor. Note 3 : The sweeper / helper will always be in posession of the cleaning tools like 6mm MS round bar / rod, plain flexible bamboo pieces and cleaning pump with wooden / PVC handle. The rate quoted is deemed to be inclusive of the cost of T & P for maintenance/ cleaning work.
LAKSHMI ENGINEERS
M/S M.N.Reddy
SAI RUPA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .