CWE (A) Jaisalmer
HQ CWE (ARMY) JAISALMER-345001
REPAIR AND MANT OF DG SETS, STREET LIGHT
2023_MES_628779_1
84129/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
POKARAN
AS PER NIT
8 documents required · 8 mandatory
₹500
AGE(I) POKARAN
₹29,000
Yes
20 Feb 2024
18 Nov 2023
30 Dec 2023
18 Nov 2023
28 Dec 2023
8 Dec 2023
18 Nov 2023 - 25 Nov 2023
Amount
M&L maintenance of DG Set of capacity 20 KVA to 30 KVA and carrying out 'B' check after 250 hours run or 3 months period which ever is earlier including cost of replacement of new 'B' check kit such as oil filter, bypass filter, airfilter, CR element and CR plates complete with 'O' rings and draining of engine oil and filling up new engine oil, spares as required and calibration of ijectors and pumps including testing complete all as specified and directed for the DG set of any make/type and various areas under AGE (I) Pokaran complete all as specified and directed. Notes :- (i) Engine oil shall be measured and paid seperately (ii) Labour &Transportation shall deemed to be included in the unit rate quoted. (iii) Repairs to DG Sets shall be carried out through authorised representative of OEM. (iv) Make of DG sets to be Repaired:- Kirloskar/Cummin/Cater Pillar/Greaves Cotton.
All as pet Item No. 01.00 above but for DG Set of capacity 45 KVA To 63 KVA complete all as specified and directed.
All as pet Item No. 01.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed.
M&L for dismantling the cylinder heads from diesel engine and sent to foundry work (work shop) for calibration and repairs by replacing the spares such as Valves, Valve Guides, Valves seats and repairs kit and re-assembling to its original position with necessary Engine cylinder head gasket and O rings for DG Set of capacity 20 KVA to 30 KVA including testing complete all as specified and directed.
All as pet Item No. 04.00 above but for DG Set of capacity 45 KVA To 63 KVA complete all as specified and directed.
All as pet Item No. 04.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed.
M&L for disconnecting all electrical connections from the unserviceable self starter of any type /make /model, opening and dismantling of self starter suitable for the DG set of capacity 20 KVA to 30 KVA for carrying out repair, complete overhauling of the system including replacing the unserviceable parts such as bearing, carbon brushes, clutch plates etc assembling and refixing the self starter in its original position and connecting all connections and testing complete all as specified and directed. Note:- Armature coil and D coil field shall be measured seperatly under relevent items of BOQ.
All as pet Item No. 07.00 above but for DG Set of capacity 45 KVA To 63 KVA complete all as specified and directed.
All as pet Item No. 07.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed.
Taking down old unserviceable armature coil from self starter for the DG set of capacity 20 KVA to 30 KVA, 12 volts and S&F armature coil suitable for any make/type of DG set including testing complete all as specified and directed.
All as pet Item No. 10.00 above but for DG Set of capacity 45 KVA To 63 KVA complete all as specified and directed.
All as pet Item No. 10.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed.
M&L rewinding of field coil for self starter of 12 volts with fine enamelled copper conductor of same gauge with 'F' class insullation, size twins and weight with necessary insulating materials, guage of conductor suitable for any make or type of DG set of capacity 20 KVA to 30 KVA as required for the DG set and testing complete all as specified and directed
All as pet Item No. 13.00 above but for DG Set of capacity 45 KVA To 63 KVA complete all as specified and directed.
All as pet Item No. 13.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed.
M&L for removing the defective charging dynamo of capacity 24 volts DC of any type / model / make of any capacity and opening it by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling and lubricating of the same replacing the armature and field coils reconnecting the same and refixing all items in original position testing and commissioning complete all as specified and directed.
All as per Item No. 16.00 above but for 12 volts DC Charging dynamo complete all as specified and directed.
M&L for disconnecting and dismantling of fuel pump assembly from its original position by opening of nuts and bolts, renewing of pump repair kit and fuel pipe refixing the same after overhauling including calibration and testing complete for the DG sets of capacity 20 KVA to 30 KVA complete all as specified and directed.
All as pet Item No. 18.00 above but for DG Set of capacity 45 KVA To 63 KVA complete all as specified and directed.
All as pet Item No. 18.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed.
M&L for calibration of water pump complete, overhauling, replacing of gaskets, nuts, washers etc and reassembling the same and refixing the pump to the engine and testing including taking down the old unservicable water pump of any capacity of DG set from the engine and taking it to out side workshop, for the DG set of capacity 20 KVA to 30 KVA complete all as specified and directed.
All as pet Item No. 21.00 above but for DG Set of capacity 45 KVA To 63 KVA complete all as specified and directed.
All as pet Item No. 21.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed.
M&L disconnecting the cooler from any capacity and any type of DG set/make/size from the existing location duly removing of all mechanical and electrical connections and taking down the same for servicing, opening the parts and cleaning thoroughly by using suitable material and acid complete all as specified and directed.
M&L disconnecting the unservicable DC wiring from DG set of any type and rewiring the same with suitable new wire of existing guage by providing flexible pipe and testing complete for any type of DG set/make/size etc complete all as specified and directed.
M&L disconnecting the oil cooler of any DG set of capacity 20 KVA to 30 KVA any make and model from the existing location duly removing of all the mechanical and electrical connections and taking down the same for complete servicing, opening the connected parts and cleaning thoroughly by using with suitable material and acid complete all as specified and directed
All as pet Item No. 26.00 above but for DG Set of capacity 45 KVA To 63 KVA complete all as specified and directed
All as pet Item No. 26.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed
M&L taking down defective Turbo Charger Assembly duly disconnecting the mechanical and electrical connections from DG Set of capacity 100 KVA to 160 KVA, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit and spares as required at site including any mechanical and reassembling and refixing the turbo charger assembly to its original position and reconnecting the same and including testing complete all as specified and directed.
Draining out fuel from fuel tank of DG set of capacity 20 KVA to 30 KVA any type and keeping it in separate container safely, disconnecting all the fuel lines and other electrical and mechanical connections and taking out the fuel tank for cleaning of tank both internally and externally for removing all the accumulated dusts or sediments, leak testing the tank, welding and brazing including one coat of synthetic enamel paint and refixing the tank to its original position, replacing the drain plug and PVC pipe protecting with flexible pipe, calibrating the fuel tank, refilling the drained out fuel back in to the tank and marking of litres in guage and provision of locking arrangement complete all as specified and directed
All as pet Item No. 30.00 above but for DG Set of capacity 45 KVA To 63 KVA complete all as specified and directed
All as pet Item No. 30.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed
Supply only engine oil of grade 20W/40 for DG sets complete all as specified and directed.
Supply only engine oil of grade15W/40 (Multi grade) for DG sets complete all as specified and directed.
Supply and topping up of Acid Mixture suitable for Lead Acid Batteries of capacity 12V / 24V complete all as specified and as directed.
Supply and topping up of distilled water suitable for Lead Acid Batteries of capacity 12V / 24V complete all as specified and as directed.
S&F Automatic Voltage Regulator (AVR) suitable to DG set of capacity 20 KVA to 30 KVA including disconnecting of all electrical connections of existing unserviceable automatic voltage regulator of any size/make complete all as specified and directed.
All as pet Item No. 37.00 above but for DG Set of capacity 45 KVA To 63 KVA complete all as specified and directed
All as pet Item No. 37.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed
M&L attending complaints for any type of DG set of emergency basis to clear/rectify both electrical and mechanical faults of DG set installed at various locations under AGE (I) Pokaran complete all as specified and directed.
M&L repairs to AMF Panel for DG Set of capacity 100 KVA To 160 KVA including checking of wiring / circuits and locating or rectfying faults including replacement of relays, Timer set and other required items if any for its function as per OEM of manufacture firm complete all as specified and as directed.
S&F in replacement of Line Voltage Monitors (LVMS) of existing make to DG set of 100 KVA to 160 KVA capacity with all listed parameters including testing complete all as specified and as directed.
S&F in replacement of Rectifiers of existing Make to DG Set of 100 KVA to 160 KVA capacity with all listed parameters including testing complete all as specified and directed.
S&F 12 V, 180 AH maintenance free battery suitable for DG set complete all as specified and directed.
S&F heavy duty battery cable lead of copper conductor with copper lugs terminal for the 12 V, 180 AH maintenance free battery suitable for DG set complete all as specified and directed.
S&F battery brass terminal and jelly complete all as specified and directed.
M&L taking down the old unservicable Radiator assembly of DG Set of capacity 20 KVA to 30 KVA by unscrewing all mechanical and electrical connections from the existing mounting and disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of the radiator and cleaning throughly the chocked pipes of the radiator by using detergent like castic soda, cotton watse etc and refixing the same to its original position with suitable size of nuts and bolts, washers etc complete all as specified and directed.
All as pet Item No. 47.00 above but for DG Set of capacity 45 KVA To 63 KVA complete all as specified and directed.
All as pet Item No. 47.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed.
S&F in replacement of microprocessor based control unit suitable to DG set of 100 KVA to 160 KVA capacity with all listed parameters including testing complete all as specified and directed.
S&F in replacement of 'V' Belts for any capacity/make of DG Set complete all as specified and directed.
S&F in replacement of Fan Belts for any capacity/make of DG Set complete all as specified and directed.
S&F in replacement of Dinamo Belts for any capacity/make of DG Set complete all as specified and directed.
S&F in replacement of Water Belts for any capacity/make of DG Set complete all as specified and directed.
Supply only coolant (DFC 50%) for DG sets complete all as specified and directed.
S&F in repairs air cleaning element inner and outer with necessary 'O' ring for the DG set of capacity 20 KVA to 30 KVA as that of existing make and model complete all as specified and directed.
All as pet Item No. 56.00 above but for DG Set of capacity 45 KVA To 63 KVA complete all as specified and directed.
All as pet Item No. 56.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed.
Calibration of PT Pump and replacement of PT Pump kit, gasket, etc whichever is required for smooth functioning of DG set complete all as specified and directed.
S&F and testing run the Fly wheel Ring of existing model size suitable for DG set of any capacity including taking down old unserviceable fly wheel ring complete all as specified and directed.
S&F 12 V, 80 AH maintenance free battery suitable for DG set complete all as specified and directed.
S&F 4 sqmm 2 core, 240 volts aluminium solid conductor cable heavy duty PVC insulated ISI marked complete all as specified and directed.
M&L for repair to LED street light fitting 35/45/60/90 Watt incl replacement of unsv items like driver, module, controller any size of watt, and taking down LED street light, nut bolt, clamp and refixing after reapir on same pole etc complete all as specified and directed.
S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Taking down old unserviceable LT cable of cross sectional area 10Sqmm 2 Core and supply and Laying in trenches/through pipes/ducts or on poles/walls jointing to OH conductor, LT panels, main switch with cable size aluminum lugs and testing XLPE insulated, armoured heavy duty electric cables with aluminum conductor, 1100 volt grade complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and n. exc 1.5M deep for fdn / trenches and getting out for soft / loose soil.
Removing excavated material any type n exc 50m and depositing at a level n.exc 1.5M above ground.
Returning in filling in layers, spreading leveling, watering and well ramming in layers n.exc 25m in sof/loose soil.
M&L for sand cushioning to PVC cable with tibba sand and punning to provide required cover complete all as specified and directed. Note:- Punned thickness shall be maeasured and paid.
M&L for cleaning down complete body including fitting and fixture of desert cooler of air flowing capacity 4000/5000 Cum/per hour of any make with wire including removal of all sludges, loose paints, dust, dirt etc and prepared the surface clean for painting and applying two coats of rubber based paint inside the water tank complete, including rewriting of MES No. complete all as specified and directed.
S&F fan motor of single phase 230 Volt, 1400 RPM 3 speed 1/8 HP for desert cooler incl cast iron rings for motor with clamps nuts & bolts complete all as specified and directed.
All as per Item No 73.00 above but fan motor 24" sweep 900 RPM complete all as specified and directed.
S&F PVC flexible pipe of 16 mm outer dia complete with PVC elbow, tee as required complete all as specified & directed.
S&F repair wood wool pad (set of three) minimum weight 0.8 Kg, proper fixed in 3 side of panels of desert cooler complete all as specified & directed.
S&F in repair, plug top 3 pin 5 Amp with cable upto 2mtr, 230 Volt (ISI marked) complete all as specifide & directed.
S&F in repair, PVC insulated and PVC sheathed round flexible three core copper conductor cable of size 40/0.0076 Sqmm including making necessary connections for desert coolers complete all as specifide & directed.
S&F in repair capacitor 4 Mfd for fan motor of desert cooler complete all as specifide & directed.
Supply and replace water spray pump 1/30 HP for desert cooler complete all as specified and directed.
S&F PVC fan blade for fan motor of desert cooler of 20" sweep complete all as specifide & directed.
M/s Rashid Mohammed
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .