Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.4 LAccepted-AOC 6 2 B 1 SHASTRI NAGAR KHANDARI AGRA UTTAR PRADESH 282002 | AGRA | UTTAR PRADESH | 282002 | 1 | Accepted-AOC Due to L-1 and credit | |
| 2 | 2₹17.2 L+₹1,721 (0.10%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹18.5 L+₹1.3 L (7.78%)Rejected-Finance 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹20.5 L+₹3.3 L (19.1%)Rejected-Finance | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹21.7 L+₹4.6 L (26.5%)Rejected-Finance | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Feb 2024, 6:00 pmClosed
GE (AF) Adm Area Agra 282008
GE (AF) Adm Area Agra 282008
REPAIR/ MAINT OF CEILING FANS, EXHAUST FANS, WALL FANS WITH CONNECTED ITEMS IN DOMESTIC AREA, 4 AREA INCLUDING NEW MAP-II AREA UNDER AGE EM OF GE(AF) ADM AREA AGRA.
2024_MES_638913_1
8000-2128/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE AF Adm Area Agra
₹40,000
Yes
6 Mar 2024
24 Jan 2024
21 Feb 2024
24 Jan 2024
19 Feb 2024
7 Feb 2024
Amount
Taking down/collect the unserviceable/burnt ceiling fan/exhaust fan/pedestal fan/wall mounted fan/cabin fan any sweep from any height of building/site for repair/rewinding/overhauling and re-fixing the same after repair/overhauling and testing fans complete at same place or where directed complete all as specified. NOTE :- (i) Fixing of repaired fan in any location of camp area shall be contractors responsibility at his own arrangement of transport and T& P. (ii) Old burnt wire will be contractors property and necessary credit shall be recovered as per sch of credit attached) Note – Repair/rewinding/overhauling shall be measured & paid separately under respective items of Sch.
M&L for strip opening of ceiling fan 1200/1400 mm sweep for overhauling including cleaning, greasing, oiling and minor repair work, including checking nuts and bolts, clamps etc complete and reassembling the same after testing on full load with blade complete all as specified and directed. (Note: Capacitor, Bearings, Regulators, Rubber reel and other connected items shall be measured and paid separately under respective items as supply and fixing).
Description all as per Item No 2 here-in-before but for exhaust fan size 300 to 450 mm sweep complete all as specified and directed.
Description all as per Item No 2 here-in-before but for wall mounted fan/cabin fan of size up to 450 mm sweep complete all as specified and directed.
M&L for rewinding of ceiling fan motor 1200/1400 mm sweep any make with super enameled copper winding wire ISI marked of gauge as per existing including cutting and getting out old US winding, sleeve work, varnishing , threading incl. making connections with three core copper flexible wire of suitable size and reassembling the same and two coats of synthetic enamel paints with spray painting and writing MES number ind. cleaning the fan with cleaning materials or thimmbles after testing at full load with blades to the entire satisfaction of Engineer incharge complete all as specified and directed. Note: Rewinding work of ceiling fan/ exhaust fan/ cabin/wall mounted fan shall be carried out inside the camp area at the location provided by department.
Description all as per Item No 5 here-in-before but exhaust fan of size 300 mm sweep, 230 V, AC complete all as specified and directed.
Description all as per Item No 5 here-in-before but exhaust fan of size up to 450 mm sweep, 230 V, AC complete all as specified and directed.
Description all as per Item No 5 here-in-before but for wall mounted/cabin fan of size up to 450 mm sweep complete all as specified and directed..
M&L for machining the shaft of ceiling fan to suit the gun metal bushes off sizes complete all as directed.
S&F in repair Ball bearing of ceiling fan of size 6201/6202 complete all as specified and directed.
S&F in repair Ball bearing of exhaust fans of size 6203/6204 complete all as specified and directed.
S&F in repair Gun metal bushes for exhaust fans of suitable sizes complete all as specified and directed.
S&F in repair capacitor 2.5 MFD, 230V, AC complete all as specified and directed.
S&F in repair capacitor 3.15 MFD, 230V, AC complete all as specified and directed.
S&F in repair capacitor 4 MFD, 230V, AC complete all as specified and directed.
S&F in repair shackle rubber bush/rubber reel of suitable sizes for ceiling fan 1200 / 1400 mm sweep complete all as specified and directed.
S&F in repair flexible wire 23/0.0076 size three core, 1100 V, twisted, PVC insulated, copper conductor multistrand for connection complete all as specified and directed.
S&F in repair MS nut & bolt with cut washers 8 mm dia and safety pin of suitable length for hanging of the ceiling fans complete all as specified and directed.
S&F in repair MS clamp including rubber washer, nut, bolt, washer and safety pin for hanging the ceiling fans of suitable size complete all as specified and directed.
S&F in repair Down rod MS 15mm dia, heavy duty of size 300 mm long including making hole for hanging ceiling fan complete all as specified and directed.
S&F in repair Down rod MS 15mm dia, heavy duty of size 450 mm long including making hole for hanging ceiling fan complete all as specified and directed.
S&F in repair ceiling fan regulator electronic switch type 5 stage speed variation ISI marked complete all as specified and directed.
S&F in repair ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed.
M&L for preparing the surface of ceiling fan, exhaust fan, pedestal fan including cleaning, removing grease, carbon dust and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number complete all as specified and directed.
Supply and fixing in replacement of energy effiecient 5 star rating, ceiling fan 1200mm sweep with remote operated suitable to work on single phase AC, 26/28 W 230 volts 50Hz complete with connecting electrically to ceiling rose or connector black using PVC insulated and over all sheathed 3 core cable of size 0.75 Sqmm with flexible copper conductor all as required at site or directed. MAKE:-Orient, Crompton, Havells, Bajaj Note:- Old fan ceiling fan shall be deposited at E/M store yard.
S&F in repair 15 mm bore GI Pipe, ‘medium grade’ for making down rod of required size for hanging ceiling fan including MS clamps of suitable size and shape complete all as specified and directed.
S&F in replacement sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 25 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
S&F in repair GI tubing 40 mm bore light grade with required fittings at site for provision of hanging of ceiling fans including making hole and making good the disturbed surface to match with existing specifications complete all as specified and directed.
S&F in repair mild steel louvers/shutters suitable for 300 mm sweep exhaust fan complete all as specified and directed.
S&F in repair mild steel louvers/shutters suitable for 450 mm sweep exhaust fan complete all as specified and directed.
Disconnecting and taking down old energy meter and Supply, installing, testing & commissioning of smart RF single Phase meter with AC single phase two wire, tamper proof static meter of class 1.0, 240 V, 50 Hz, 10 A to 60 A confirming to IS-16444 and relevant IEC standards within built 865-867 MHz Radio frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti temper features, Microprocessor and LED/LCD based circuitry. Meter should support sending the 15/30 mint instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for cumulative energy and Max demand to software data. Meter should have connect/disconnect functionality operable from MDM/billing software and prepaid features should be MDM/billing end as per IS-15959 part 2. The meter should support open communication protocol DLMS with the software complete all as directed. Make:- L&T cat part No. WM101BC7DLPR6INN or equivalent in Secure/Havells/HPL Note:- Old Electric meter shall be deposited at E/M store yard.
S&F in replacement existing U/S light fitting with energy saving decorative LED batten 20 watt (4 Feet), 230 volts, energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffusre & integrated electronic driver complete with all accessories prewired and includeing making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Note:- Power factor should not be less thtn 0.95 Make- Halonix Cat part No- HLTLD-04-20-CW-HL2, ORIENT Cat part No-LBLN-20-C-AL /Phlips Cat part No- BN021C LED22S PSU CW GR
S&F in replacement 18 W LED tube with builtin driver complete all as specified and directed Make :- ORIENT Cat part No-LTXL-18-C, Phillps cat part No-MAS LEDTUBE 18W, 865T8I-1800LM, Havells Cat part No- PHOTONULTRAE2.01213T8SSTL18WLED865SPC
Taking down old unserviceable copper/aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators, sockets and defective main switch/DB/MCB/Metal plug etc. by unscrewing carefully from boards etc and making good disturbed surfaces of walls complete all as specfied and directed.
M & L for point wiring for light/fan controlled by one switch with 1.5 sqmm single core 1100V grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including MS pressed steel shet (1.6mm thick) sunk box with 3mm thick ISI marked laminated bakellite sheet fixed with cromium / nicckel plated screws and washers for switches and sockets, including 1.5 sqmm single core 1100v grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduiting and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified and directed .
S&F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed.
S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed.
Supply and fixing exhaust fan 300 mm sweep steel body, AC, Single phase, 230 volts complete with louvers shutters and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan complete all as specified and directed.
Supply and fixing exhaust fan 250 mm sweep PVC body, AC, Single phase, 230 volts complete with louvers shutters and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan complete all as specified and directed.
NATIONAL AUTO MOBILES
Industrial Traders
M/S J J ENTERPRISES
TRIVENI ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .