| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC | L1 | Accepted-AOC Lower rate quoted | |
| 2 | L2₹27.6 L+₹5.4 L (24.2%)Rejected-Finance | L2 | Rejected-Finance Higher rate quoted | |
| 3 | L3₹29.9 L+₹7.6 L (34.4%)Rejected-Finance OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | L3 | Rejected-Finance Higher rate quoted |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
30 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2021_MES_427828_1
8400-528/E8
Open Tender
Civil Works - Water Works
Works
180 days
PANAGARH
Class D, Cat a (ii)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹64,000
Yes
29 Jul 2021
4 Mar 2021
1 Apr 2021
4 Mar 2021
30 Mar 2021
17 Mar 2021
60 days
Amount
Taking out vertical hollow shaft motor , (existing make Kirloskar), 3 Phase 45 HP/40HP, 1440 RPM , 50 Cycle and dismantling the rotor complete and rewinding the startor with proper gauge of super enamelled copper wire including changing of insulating material, varnishing heating properly and reassembling and refitment to its original position with replacement of connection plate including testing complete all as specified and directed. Note :- Rate quoted is deemed to inclusive to & FRO transportation charges.
Taking out rusted/worn out threaded foundation bolt after dismantling old cement concrete foundation base and S &F new anchor bolt with fasteners to bolts of size 20mm dia, 12 inch long with proper cement concrete foundation and making fair finished to match with the existing surfaces complete all as specified and directed.
Supply and laying rubber insulating mat one side chequered size 2 mtr x 1 mtr x 20 mm and duly ISI mark complete all as specified and directed.
Taking out U/S ratchet plate assembly from VT motor of any size / capacity and S&F ratchet plate assembly complete with ratchet, balls hexagonal bolts etc complete all as specified and directed.
Lifting of submersible pump of any type and capacity alongwith column pipe and 3 core flat cable complete after disconnecting of all elect and water line connection for the any make of pump & motor complete all as specified and directed.
Dismantling of submersible pump bowl assembly of any make and capacity and size complete( to be measured only after lifting against Srl item No 05 here-in above) carefully without damaging any parts of the pump and setting aside in Pump house of ascertaining the serviceability of existing dismantled parts including reassembling complete pump with the following works :- (a) Cleaning of complete pump assembly items dischagre case, impellor , Shaft suction casing bowls disc & bearing etc.(b) Checking of all rotary and statutory parts of pump bowl & stage casing assembly and making free for their satisfactory run ( Note : cost of minor spares is rubber 'O' ring , oil seal etc. is deemed to be included in the item).
S&F of the following spare parts of submersible pump of any capacity and make as per existing (M/s KSB/Kirloskar). (a) Suction Cover (Heavy)
(b) Half coupling pump
(c ) S.S Shaft (V Stg)
(d) Neck Ring
(e) S.S Sleeve
(f) Top S.S Sleeve
(g) Top Washer
(h) Allen key
(j) Key for shaft
(k) Bowl bush
(l) Coupling bush
(m) Bowl threded
(n) Discharge Outlet
(o) Non return Valve
(p) Impeller
Lowering the submersible pumping set alongwith motor, cable,column pipe and other connected accessories incl making all electrical connection,commission & testing complete all as specified and directed.
Dismantling and taking out burnout winding from the stator of motor and rewinding with PVC copper cable as replacement the quality incl connection commissioning & testing complete all as specified and directed.
Supply and laying flexible flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 25 Sqmm 3 core including jointing material and connection work complete all as specified and as directed.
Supply and laying flexible flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 10 Sqmm 3 core including jointing material and connection work complete all as specified and as directed.
S & F round strand steel wire rope dia 12 mm and connected clamp nut bolts fixed complete all as specified and directed.
M & L for Submersible pump Fully Automatic Star delta Starter In sheet Enclosure Type MU-G Motor rating AC-3,Duty 415v, 50 Hz 3 Phase to 25 HP,Relay range of 30-50 A as per existing after taking out old U/S one complete all as specified and directed.
M & L Fully Automatic Star delta Starter In sheet Enclosure Type MU-G Motor rating AC-3,Duty 415v, 50 Hz 3 Phase to 30 HP,Relay range of 30-50 A as per existing after taking out old U/S one complete all as specified and directed.
M & L for Fully Automatic Star delta Starter In sheet Enclosure Type MN Motor rating AC-3,Duty 415v, 50 Hz 3 Phase to 50 HP,Relay range of 30-50 A as per existing after taking out old U/S one complete all as specified and directed.
M & L for Timer Star Delta time of 3 sec-30 sec Voltage range 240-415VAC.Contact arrangement 1 C/O (Star)+1 C/O (Delta) as per existing after taking out old U/S one complete all as specified and directed.
M & L for 3 Pole Power Contactor type MNX, AC 3 80A as per existing after taking out old U/S one complete all as specified and directed.
M & L for Over Load Relay Direct Mounting Relay range of 30-50A as per existing after taking out old U/S one complete all as specified and directed.
M & L for Change Over switch In Sheet Enclosure rating of 200A as per existing after taking out old U/S one complete all as specified and directed.
M & L for Start Push Button as per existing after taking out old U/S one complete all as specified and directed.
M & L for Stop Push Button as per existing after taking out old U/S one complete all as specified and directed.
M&L voltmeter desutak 0-500V capacity as per existing after taking out old unserviceable one complete all as specified and directed.
M&L Ampmeter 96x96 size digital with CT ratio of 0-100 Amp as per existing after taking out old unserviceable one complete all as specified and directed.
Lifting/ lowering of vertical turbine Pump set (as per existing make and capacity). Lifting : By disconnecting of all electrical connections to motor and pump , and dismantling the motor from foundation by unscrewing foundation nuts after disconnecting delivery main and kept aside inside pump house , Lifting of VT pump assembly from bore of any depth alongwith column pipe /shaft and connected items are kept inside pump house to check the unserviceability. Lowering :- Lowering of pump assembly in bore of any depth alongwith column pipe, shaft and connected items after repair against respective item here-in- after and installation of pump motor in its original foundation, connections the same with top shaft as well as delivery main including electrical connectiion of both end i.e. with starter and motor terminals. Note :-(a) Rate quoted against items deemed to be included for lifting /lowering. (b) Chain pulley block will be used according to the load of pump alongwith column pipe and connected items.(c) Any damages to equipment due to negligence of contract during lifting/lowering to be born by contractor at this own risk & cost complete all as specified and directed.
Dismantling of turbine pump bowl asembly of any make and capacity and size complete carefully without damaging any parts of the pump and setting aside in pump house for ascertaining the serviceability of existing dismantling parts, with the following works :- (a) Through removing sludging and cleaning of complete bowl assembly items, such as bowl, discharge case , suction case , Impeller , lock collect, bearing /bushes, pump shaft complete etc. after assembling the pump. Checking of all rotary and statutory parts of pump bowl assembly and making free for their satisfactory run complete all as specified and directed.
S&F of the following spare parts of vertical turbine pump of any capacity. (Note : Make of spares shall be garden reach ship builders & engineers /WPIL) (a) Packing box bearing brass/bronze suitable for 40 mm shaft as required at site.
(b) As per item No 26 (a) same in above but 25mm shaft as per required at site
(c) All as per item No 26 (a) to (b) above but for packing box gasket
(d) Line shaft 10 feet long both end threaded 40 mm (SS)
(e) All as per item No 26 (d) here in before but for 25 mm dia (SS)
(f) Line shaft 5 feet long both end threaded 40 mm (SS)
(g) All as per item No 26 (f) here in above but for 25 mm dia (SS)
(h) Line shaft coupling suitable for 40mm dia shaft (SS)
(i) All as per item No 26 (h) above but suitable for 25 mm dia (SS)
(j) Head shaft (Top shaft , SS not exceeding 40 mm dia and 9 feet long as required at site)
(k) Head shaft (Top shaft , SS not exceeding25 mm dia and 9 feet long as required at site)
(l) Rubber bush for line shaft bearing retainer suitable for 40 mm dia line shafts and suitable for 6 inch dia column pipe as required at site.
(m) Rubber bush for line shaft bearing retainer suitable for 25 mm dia line shafts and suitable for 6 inch inch dia column pipe as required at site.
(n) Bearing retainer bronze suitable for 6" dia column pipe and 40 mm dia line shaft as required at site.
(o) All as per item No 26(m) here in above but 6'' dia coloum pipe and for 25mm dia shaft.
(p) Shaft sleeve as suitable for line shaft 40mm dia (SS)
(q) Shaft sleeve as suitable for line shaft 25 mm dia (SS)
(r) MS Column pipe wall thickness minimum 6.90 mm, 6 inch dia, 10 feet long both end threaded (8 TPI) fitted with coupling at one end.
(s) All as per item No 26(q) above but for 6" dia, 5 feet long
(t) Intermediate bowl CI 10 cc/1607 as per existing sample.
(u) MS column coupling suitable for 6 inch dia , column pipe (8TPI) 7.1 mm minimum thickness ( internally threaded ) heavy duty.
(v) Intermediate bowl bush rubnber 25 mm for any type and size of bowl
(w) Intermediate bowl bush rubber 40 mm for any type and size of bowl
(x) All as per item No 26(u&v) above but brass gun metal .
(y) Impellor lock collect carbon steel suitable for upto 40mm dia pump shaft as per existing sample
(z) Suction/discharge case CI suitable for 10CC/1607 or any type of bowl as per existing sample
(aa) Suction / discharge case bearing bronze suitable for item No 3 (al) above upto 40mm dia pump shaft or as per existing sample.
(ab) Impeller close type bronze suitable for 10 CC/1607 upto 40mm dia pump shaft or as per existing smaple
(ac) Bowl stud suitbale for 1607 or any type and size of bowl or as per sample make : OKW/TVS or equivalent.
(ad) pump shaft SS upto 40mm dia 9 feet long suitable for 10 stage bowl assembly having 1607 bowl or any type of bowl or as per existing sample
(ae) Split packing gland suitable for 40 mm head shaft with packing gland stud and nut complete.
(af) -do- but 25 mm shaft
(ag) Packing box suitable for upto 20000 GPH pump set
(ah) Adjusting nut alongwith lock screw for 40 mm dia top shaft.
(aj) Adjusting nut alongwith lock screw for 25 mm dia top shaft.
(ak) pump shaft and hallow shaft motor coupling complete suitable for 20000 GPH pump set
Cutting , facing and threading of column pipe upto 150mm dia of length n.exc 10 feet each all as directed as required at site ( Rate are inclusive of transportation, loading /unloading etc of the item from installation to civil workshop & back.)
All as per item No 27 here-in-above but for line shaft/top shaft any type n.exc 40mm dia & 10 feet long complete all as specified and directed.
Transportation of complete pump shaft, line shaft, head shaft ( top shaft) etc of any VT pump asembly and complete impeller assembly Old/New from pump house to civil workshop for carrying out the under mentiioned work and back to installation for refitment etc :- (a) Proper alingment of pump shaft, line shaft and top shaft. (b) Proper balancing of the impellers
Decoupling of VT hollow shaft motor 45 HP , 3 Phase ( make : Kirloskar), from pump, supply and fixing with new thrust bearing 7220B ( Make : SKF/TATA or equivalent) incl greasing after taking out the old U/S thrustbearing from motor complete all as specified and directed.
All as per item No 30 above but ball bearing 6311 ( make : SKF/TATA or equivalent) complete all as specified and directed.
SUPPLY ONLY CALCIUM BASED GRANULAR DISINFECTANT MORE STABLE THAN CHLORINE GAS AND STRONGER THAN BLEACHING POWDER AND SODIUM HYPOCHLORITE) PACKING IN 45 KGs PLASTIC DRUMS FOR POWER HOUSE 2 WATER SUPPLY FOR THE FOLLOWING PUMPS (Make: M/s Shree Rayalaseema Hi-Strength Hyp Ltd & equivalent, Brand : Purichlor):- (a) PH- D Camp Reservoir capacity 1,00,000 Glns. (b) PH- 19 Reservoir capacity 1,00,000 Glns. (c) PH-4 Reservoir capacity 1,00,000 Glns. (d) PH-Swimming Pool 10000 Glns (e) PH-6 Reservoir capacity 10,000x2 Glns. (f) PH- EME Line Reservoir capacity 50,000 Gln. (g) PH-16 Reservoir capacity 50,000 Glns. (h) PH-104 KLP Reservoir capacity 50,000 Glns. (j) PH- 15 Reservoir capacity 10,000x2 Glns. (h) ILP PH-1,2&3 Reservoir capacity 50,000x3 Glns.
Taking out chlorine Dozing machine, transporting to workshop of manufacture or authorized dealer, dismantling the dozing plant, cleaning, disconnecting electric connection of all Job parts taking out all defective parts and supply and fix new parts for replacement (New parts will be measured and paid separately under Item No-34 and 35 here-in- after reassembling, testing and re-fixing complete all as specified and directed.
Supply following spare parts of Decrin dozing Pumps Make : (Existing make) Declibac to be incorporated against Item No 33.00 here in before. (Fixing rate deemed to be included in the item No-33) (a) Rotor assembly with brackets & tolerance rings part No.PMBRPL2
(b) 7 Pump Head (Ferrules 1/4" & duckbill included) Part No.UCPH7FD
(c) 7 Pump Tube Part No.MCCP207 (5 PK)
(d) Injection check valve3/8" Part No.MCINJ38 (5 PK)
(e) Weighted suction line strainer 3/8" Part No.ST138
(f) 3/8" weighted suction /discharge tubing Part No- MALT002
(g) Checkvalve duckbill only (PK of 5)Part No-MCCVDBO
(h) Connecting nut 3/8"Part No-MANUT00
(j) Rollar Assambly 4 -Pack Part No MC3ASYD
(k) Coil 250 V 50 Hz Part No MP6J222
Supply following spare parts of Chemical chlorine dozing Make :(As per existing make) Sataya Saibac to be incorporated against Item No-33 here in before. (Fixing rate deemed to be included in the item No-33) (a) PVC dosing head assembly with suction and delivery with NRV for 25 LPH
(b) PVC NRV set with glass ball for suction and delivery adopter.
(c) PVC adopter for suction and delivery without NRV
(d) PVC stainer washer type heavy duty or Y type stainer for suction.
(e) Teflon gland square type 3 mm
(f) Chemical oil seal with cap
(g) Dosing aligator gear box 25 LPH
(h) Plunger assembly without plunger dosing head 25 LPH
(i) Plunger assembly with PVC dosing head complte 25 LPH
(j) Heavy duty FRP Tank capacity 150 ltr.
M&L for nylon tube ¼ “ dia for chlorine dozing system complete all as specified and directed.
S&F NRV (antisyphon valve) for chlorine dozing system complete all as specified and directed.
Supply and laying of UPVC (SCHD 80 ) concealed pipes 20 mm outer dia, UV stabilized and having thermal stability for hot & cold water supply all fittings laid in trenches / wall including all fittings including taking out old U/S one complete all as specified and directed.
Repair to the motor (230 Volt 50 Hz) Power 120 watt) of agitator belongs to chlorine dozing system by dismantling the rotor complete rewinding the stator with proper gauge of super enamelled copper wire including changing of insulating material proper heat varnish, painting replacement of bearing complete & connected with chlorine dozing system afitetor complete all as specified and directed.
S & F LT Indoor type Panel board (shock proof, rust proof, corrosion free, acid & chemical resistant, fire retardant, having high impact made of halogen and silica free recycle material, UV resistant) polycarbonate body suitable size floor mounted having high grade gasket made of polyurethane should withstand glow wire test at 960 centigrade. should be flame retardant, approved by (CPRI) type tested as per IEC-60 439-1, IP54(EN60529) with following accessories with commissioning and testing complete( make- HENSEL/EMITER/ABB) 1. Temperature rise 2. Dielectric Properties 3. Short circuit test 4. Effectiveness of Protective Circuits 5. Clearance & Creepage Distance 6. Mechanical Operation 7. Polycarbonate thermoplastic Board (a) Incoming MCCB 200 Amps, 415 V, 3 phase, 50 Hz, Four Pole, 25 KA- 1 No, (b) Outgoing (i) MCCB 125Amps,415 V, 3 phase, 50 Hz, 3 Pole, 25 KA- 2 No, (ii) MCB 40Amps,TPN - 02 Nos (c) Change over switch 200 Amps 4 pole - 01 Nos (d) Fully Automatic Star delta Starter In PVC sheet Enclosure Type MN Motor rating AC-3,Duty 415v, 50 Hz 3 Phase to 50 HP,Relay range of 30-63 A.- 02 Nos (e) Copper Busbar rating- 300 Amps- 04 Nos (f) LED Indicating lamp- 03 Nos (g) Digital Ammeter - 1 Nos (h) MCB SP 6 Amps for fuse unit - 6 Nos (i) Digital Voltmeter - 01 Nos (l) CTR 200/5 Amps - 03 Nos
BANSAL CONSTRUCTION
M/S Ali Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .