Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹5.2 L
EMD Value
₹10,394
Closing Date
25 Jul 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (Electrical Tenders)
O/o Sr. Chief Engineer (Electrical), BSNL TamilnaduElectrical Zone, 5th Floor Tamilnadu Telecom Complex,No.60,Ethiraj Salai,Chennai - 600008
SITC of LT CT Meter panel and Misc. electrical works for HT to LT Conversion at TE CTMX exchange Coimbatore
2024_BSNL_201456_1
19/CEE/BSNL-TNEZ/2024-25
Open Tender
Electrical Works
Item Rate
30 days
Coimbatore
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts Officer (Cash), O/o GMT, BSNL, Coimbatore
₹10,394
Yes
26 Jul 2024
15 Jul 2024
26 Jul 2024
15 Jul 2024
25 Jul 2024
15 Jul 2024
ITC of CT metering panel i/c all acessories i/c dismantling loading shifting from TE Ganapathy unloading at TE CTMX as required
ITC of LT panel having 250A switch , fuse cut out i/c all acessories i/c dismantling loading shifting from TE Ganapathy unloading at TE CTMX as required
S/F of 12mm thick Hylam sheet for fixing EB Meter and glass window in the front. Apprx dimension 400mmx500mm
Test Terminal block compartment with 12mm thick hylam sheet for fixing the TTB.
3ø Busbar with 25mm x 10mm cu.strip for phases and 25m x 6mm cu.strip for neutral with supports for fixing CTs.
200/5 A. class: 0.5 S Cast resin type CT's-3 Nos (TNEB approved make)
Supplying and fixing of 250A, TPN switch disconnector fuse unit with sheet steel enclosure, with cable gland box for cable termination with suitable HRC fuses for operation on 415V, 50Hz, 3 Phase AC supply including fixing on surface of wall testing and commissioning etc as reqd.,(make:- L& T FN 250 or SS make)
Supplying of one number 31/2X 185sqmm PVC insulated and PVC sheathed / XLPE Aluminium power cable of 1.1 KV grade etc as reqd
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
(a) 3½ x 185 sq. mm
Supplying & Drawing of 70 Sq.mm single core PVC insulated copper Conductor wire for interconnections etc as reqd.,
Supplying and making end termination only with lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
(a) 70Sq.mm Cu. Cable
(b) 120 Sq.mm Al. Cable
Laying 5" dia 'B' Class GI Pipe in Over Head for protection of UG Cable etc as reqd.,
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.,
Breaking the existing cement concrete floor of 0.25mx0.3mx 9 mtr by suitable tools and man power and making the same as good after completing the work with suitable concrete mixture etc as reqd
De-commissioning the HT supply system by switching off air-break switch, removing HT fuses, earthing the HT fuse points, turning off MOCBs, removing the LT cable of the transformers in the MV Panel etc and testing & commissioning the LT Supply.
Supplying and fixing the following MS chennel/Angle iron in the existing cable truch with necessary tools and plant i/c cutting,welding and granding etc as reqd
75x40x5mm thick MS chennel
35x35x5mm MS angle iron
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Attending of Fault in ACB neutral contactor necessary servicing etc as required.
Shifting and relaying/ fixing of existing MS angle iron trays from Dtax race course to TE CTMX i/c cutting the same for suitable size joining the trays with suitable boltsnuts including drilling/ welding , paiting etc as required VERTICAL RUN I/C DIGGGING GROUND AND PROVIDING CONCRETE finishing etc as required
Shifting and relaying/ fixing of existing MS angle iron trays from Dtax race course to TE CTMX i/c cutting the same for suitable size joining the trays with suitable boltsnuts including drilling/ welding , paiting etc as required HORIZONTAL RUN
S/L of 4x1.5 sq.mm PVC insualted and PVC sheathed armoured copper conductor cable on surface of wall i/c terminations at both ends etc as required (ISI marked)
S/F 4' 20watts LED light fittings i/c connections etc as reqd. (Make: philips/ havells/ crompton/ Similar Superior Make)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on cable tray as required above 95 sqmm and up to 185 sqmm (25/40 x 3mm ms flat)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on cable surface of wall as required above 95 sqmm and up to 185 sqmm (25/40 x 3mm ms flat)
SAIDAPET ELECTRICALS
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .