| 1 | L1₹54.9 LAccepted-AOC | L1 | Accepted-AOC RADHE KRISHNA CONSTRUCTIONS 1st Loest amount Quart | |
| 2 | L2₹55.7 L+₹86,418.37 (1.57%)Rejected-AOC | L2 | Rejected-AOC Ranjan Kumar Singh 2nd Loest amount Quart |
Tender Value
₹55.5 L
EMD Value
₹1.1 L
Closing Date
13 Mar 2024, 11:00 amClosed
Executive Engineer NREP1 ranchi
Executive Engineer NREP1 ranchi Vikash Bhawan Ranchi
Construction of 4 Class Room in Bhakti Vedanta Vidya Bhawan Gurukul Vidyalaya Kutam Muri Ranchi
2024_NREPR_85045_1
NREP1/45_I/23-24
Open Tender
Civil Works
Item Rate
270 days
Ranchi
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
Yes
₹1.1 L
Yes
30 Jun 2024
6 Mar 2024
14 Mar 2024
6 Mar 2024
13 Mar 2024
6 Mar 2024
Amount
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l.
Extra for earthwork in hard soil as per specification and direction of E/l (vide classification of soil item-B)
Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume).
Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including' cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume).
Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level: 1:2 :4 (1 cement : 2 coarse sand(zone-III) :4 graded stone aggregate 20 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1½ :3 (1 cement : 1½ coarse sand(zone-III) :3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns pillars, piers, abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering, shuttering and finishing and reinforcement : 1:1½ :3 (1 cement : 1½ coarse sand(zone-III) :3 graded stone aggregate 20 mm nominal size)
Providing designation 75 A brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing and laying damp proof course 50mm thick with cement concrete 1:2 :4 (1 cement : 2 coarse sand(zone-III) :4 graded stone aggregate 20 mm nominal size)
Providing designation 75 B brick work in C.M.(1 :6) in superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.
Reinforced cement concrete work in beams, suspended floors, roof having slope up to 15o landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases, and spiral staircases above plinth level upto floor five level excluding cost of centering, shuttering and finishing and reinforcement with 1:1½ :3 (1 cement : 1½ coarse sand(zone-III) :3 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for Column, pillars, piers, abutments, posts and struts
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. Roof slab
Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, chajjas, corbels etc. including edges. Chhajja
Supplying, fitting and fixing 20 guage G.C.I, sheet gate fitted on M.S. Angle frame of size 60x60x6mm. including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l.
Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.)
Providing and laying Double charge vitrified floor tiles in diiierent sizes (thickness to be specified by by the manufacturer) with water absorption less than 0.08% and conformrng to lS 15622 / ISO 13006 of approved make in all colours and shades ,laid on 20 mm thick cement mortar 1: 4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc cornplete Size of Tiles 600x600 mm
Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l.
Finishing wall with Premium Acrylic Smooth exterior paint of required shade New work ( two or more coats applied @ 1.67 ltr./10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kgs/ 10 sqm.)
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/l.
Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion (i)Single socketed pipes
Providing and fixing on wall face unplasticised-PVC moulded fitting/accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. 110 mm
110 mm bend
Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised -PVC rain water pipes by means of 50x50x50 mm hard wood plugs screwed with MS screws of required length including cutting brickwork and fixing in cement mortar1:4(1 cement :4 coarse sand) and making good the wall etc.complete.110 mm
Providing Tor steel reinforcement of 8mm. dia. rods as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. TMT Fe 500 (Only Valid for SAIL & TATA Steel, JSPL ,Electro Steel Ltd. and Vizal Steel)
Providing Tor steel reinforcement of 10mm. ,12mm & 16mm dia. bars as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (TMT,Coil Fe 500) (Only Valid for SAIL & TATA Steel, JSPL ,Electro Steel Ltd. and Vizal Steel) (a) 10mm
Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement : 3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation, levelling & dressing & finishing the top smooth.
Providing 250mm. wide brick drain in cement mortar (1:6) with av. 250mm. clear depth and 250mm. apron including cost of earthwork involved with 75 mm. ~ cement concrete (1:4:8) over one brick designation 75A flat soling in proper grade and slope at the base, the drain duly plastered in C.M.(1:3) with punning over exposed surface all complete as per building specification and direction of E/l.
Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I (a) Sand Lead-8km pucca
(b) Brick Lead-8km(1k+7p)
(c) Stone chips Lead-10km Pucca
(d) Stone metal Lead-10km pucca
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with piano type switch phenolic laminated sheet, suitable size PVC / GI box etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing 3 pin 5 amp. Ceiling rose on the existing junction box/wooden block including connection etc. as required
Supplying and fixing batten/angle holder including connection etc. as required
Installation, testing and commissioning of pre-wired, flourescent fitting/ compact fluorescent fitting of all type complete with all accessories and tubes etc. direcly on ceiling/wall including connection with 1.5 sq. mm FRPVC insulated, copper conductor, single core cable and earthing as required.
Supply installation, testing and commissioning of following size ceiling fan 3 Blades conforming to IS:374:2019 including wiring the down rod of standard length (upto 30 cm) with 1.5 sq.mm. FR PVC insulated, copper wire suitable for 230V 50 Hz, single phase supply etc complete as required. 1200mm (48") ceiling Fan
Supply installation, testing and commissioning of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. S/F following sizes of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit etc. as reqd. 20 mm PVC Conduit
25 mm PVC Conduit
S/F folloing Piano type switch / Socket on the existing switch box/cover including connection etc. as reqd. 5/6 amps, one way switch
3 Pin 5/6 amps, socket outlet
Supplying and fixing PVC/GI box of following size on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required. 170 mm x221 mm x 48 mm deep / (8" x10")
Supplying and fixing following way single pole neutral, sheet MCB distribution board, 240 Volts, on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, phosphatized and powder painted including earthing etc. as required (but without MCB / RCCB / Issolator) 8 way double door
Supplying and fixing 6 amps to 32 amps rating 240 volts 'B' Series miniature circuit breaker suitable for lighting and other loads of following pole in the existing MCB DB complete with connection testing and commissioning etc. as reqd. Supplying and fixing following, 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6/32 amps, D.P.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with piano type switch phenolic laminated sheet, suitable size PVC / GI box etc. as required.Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing 3 pin 5 amp. Ceiling rose on the existing junction box/wooden block including connection etc. as required
Supplying and fixing batten/angle holder including connection etc. as required
Installation, testing and commissioning of pre-wired, flourescent fitting/ compact fluorescent fitting of all type complete with all accessories and tubes etc. direcly on ceiling/wall including connection with 1.5 sq. mm FRPVC insulated, copper conductor, single core cable and earthing as required.
Supply installation, testing and commissioning of following size ceiling fan 3 Blades conforming to IS:374:2019 including wiring the down rod of standard length (upto 30 cm) with 1.5 sq.mm. FR PVC insulated, copper wire suitable for 230V 50 Hz, single phase supply etc complete as required. 1200mm (48") ceiling Fan
Supply installation, testing and commissioning of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required. 20/22W LED Tube light
S/F following sizes of PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit etc. as reqd. 20 mm PVC Conduit
25 mm PVC Conduit
S/F folloing Piano type switch / Socket on the existing switch box/cover including connection etc. as reqd. 5/6 amps, one way switch
3 Pin 5/6 amps, socket outlet
Supplying and fixing PVC/GI box of following size on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required. 170 mm x221 mm x 48 mm deep / (8" x10")
Supplying and fixing following way single pole neutral, sheet MCB distribution board, 240 Volts, on surface / recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, phosphatized and powder painted including earthing etc. as required (but without MCB / RCCB / Issolator) 8 way double door
Supplying and fixing 6 amps to 32 amps rating 240 volts 'B' Series miniature circuit breaker suitable for lighting and other loads of following pole in the existing MCB DB complete with connection testing and commissioning etc. as reqd. 6/32 amps, single pole of "B" Series
Supplying and fixing following, 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6/32 amps, D.P.
Add 18% GST (In Basic Rate must fill 18)
Add 1% Labour Cess (In Basic must Rate fill 1)
RANJAN KUMAR SINGH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .