Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAccepted-AOC 144 VIKAS BAZAR MATHURA UP 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | ₹38.3 L | L1 | Accepted-AOC THE LOWEST TENDERER |
| 2 | L2₹39.9 L+₹1.6 L (4.08%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | ₹39.9 L+₹1.6 L (4.08%) | L2 | Rejected-Finance NOT THE LOWEST TENDERER |
| 3 | L3₹47.8 L+₹9.5 L (24.7%)Rejected-Finance | ₹47.8 L+₹9.5 L (24.7%) | L3 | Rejected-Finance NOT THE LOWEST TENDERER |
| 4 | L4₹48.7 L+₹10.4 L (27.1%)Rejected-Finance NADUA GAON POST NADUA DIKOM DIST DIBRUGARH ASSAM 786 101 | DIBRUGARH | DIBRUGARH | ASSAM | 786101 | ₹48.7 L+₹10.4 L (27.1%) | L4 | Rejected-Finance NOT THE LOWEST TENDERER |
| 5 | L5₹57.0 L+₹18.6 L (48.6%)Rejected-Finance | ₹57.0 L+₹18.6 L (48.6%) | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
11 Jun 2024, 6:00 pmClosed
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
REPAIR/MAINTENANCE AND IMPROVEMENT OF LT FEEDER PILLAR BOX LT PANEL BUS BAR PANEL LT SWITCH GEAR AND OTHER ALLIED WORK AND REPAIR MAINT OF STREET LIGHTS SECURITY LIGHT AND ALLIED WORKS AT ZONE D AREA UNDER GE (EAST) MATHURA
2024_MES_652212_1
8200-1419/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE EAST MATHURA
₹1 L
5 Sept 2024
3 May 2024
18 Jun 2024
3 May 2024
11 Jun 2024
28 May 2024
3 May 2024 - 4 Jun 2024
Amount
Excavation in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for foundations, laying of cables etc. and getting out as in soft/loose soil complete all as specified and as directed.
All as per item serial No 1.00 here-in-before but depth exc 1.5m but n exc 3.00 m complete all as specified and as directed.
Returning filling in earth obtained from excavation including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for clean dry Yamuna sand laid in trenches/ducts for bedding and cushioning to cable including spreading and levelling complete all as specified and as directed. Note : Punned thickness of sand shall only be measured for payment purpose.
Supply and Laying in trenches Unreinforced precast concrete cable cover class LV type 1, flat, size 250mmx150mmx40mm for cable protection cover laid adjacent to each other lengthwire perpendicular to central axis of cable complete all as specified and as directed.
Supplying, laying or fixing or passing through pipe, testing and commissioning XLPE insulated, steel tape/wire, armoured heavy duty electric underground cable, aluminium stranded conductor 1100 volt grade of following cross sectional area :- Note : Excavation and earth works shall be measured and paid separately under appropriate items of this BOQ.
10 Sqmm 2 core.
10 Sqmm 4 core.
16 Sqmm 4 core.
25 Sqmm 4 core.
35 Sqmm 3.5 core.
50 Sqmm 3.5 core.
70 Sqmm 3.5 core.
95 Sqmm 4 core.
120 Sqmm 4 core.
S&F steel tubes light grade galvanised with all fittings fixed to walls/ under floors/along poles/ road crossing etc of following sizes complete all as directed:-
40mm bore.
50mm bore.
80mm bore.
M&L for dismantaling of old unserviceable MS pole any type and size complete all as specified and as directed.
Supply and erecting steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & screws made out of mild steel tubing, type 410 SP -31 (9 Mtr long) including marking pole No on pole including applying two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) on exposed surface over a coat of red oxide primer and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and as directed. Note : Earth work and PCC in foundation shall be measured and paid separately.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping complete all as specified and as directed.
Cutting wild grass, bushes, creaper, unwanted vegetation from inside / surrounding of E/M installations, near transformers, pole structures etc including cutting creapers from barbed / cattle fencing of the installations as when directed and removing of unwanted material from installation compound and depositing complete all as specified and as directed. Note : The item shall be operated maximum three times in entire period of contract in the same installations. (Area shall measured separately each time).
M&L & tools for trimming tree branches upto 100 mm girth of any location around existing HT/LT OH lines giving clearance of 1.5 m on all sides complete all as specified and as directed. Note : Trimming of tree branches irrespective in numbers in each tree shall be measured as one unit).
Supply, installing, commissioning and testing of LT panel board Kiosk type (factory made of approved CPRI) made out of CRCA sheet 3.15mm thickness for outer sheet and 2mm thickness for inner sheet dust proof, powder coated from both side as per latest IS/IEC, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and water proof duly supported on 40 x 40 x 6mm angle iron frame, opening arrangement from front & rear both duly fitted with compression cable glands for entry & exit of cables having minimum clearance of 450mm above ground level complete comprising of the following including taking down old U/S LT panel all as directed by Engineer-in-Charge:- (a) Aluminium bus bar -- 03 Nos. For phase of capacity 100 Amp and 1 Nos 100 Amps for neutral, duly taped in colour coded FRP sleeves. (c) LED Indicating lamps Red, Yellow and Blue in colour, complete with lamp holders, 220 volts AC.- 01 Set of 3 (d) Panel wiring with 2.5 Sqmm PVC Sheathed, PVC insulated FR-HR stranded copper conductor cable through MCB DP 10 A mounted on DIN rail. (e) MCCB 4 Pole, 100/125 Amp, (Ics=100%Icu) 415 V, 36 KA - 01 No (incoming) (f) MCCB 4 Pole, 63 Amp, (Ics=100%Icu) 415 V, 16 KA - 04 No (outgoing) Note : (i) Drawing of LT panel shall be got approved from Engineer-in-Charge before placing order for procurement. (ii) Cost of taking down of Panel is deemed to be included under unit rate quoted.
Supply, installing, commissioning and testing of LT outboard panel board Kiosk type (factory made of approved CPRI) made out of CRCA sheet 3.15mm thickness for outer sheet and 2mm thickness for inner sheet dust proof, powder coated from both side as per latest IS/IEC, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and water proof duly supported on 40 x 40 x 6mm angle iron frame, opening arrangement from front & rear both duly fitted with compression cable glands for entry & exit of cables having minimum clearance of 450mm above ground level complete comprising of the following including taking down U/S LT panel all as directed by Engineer-in-Charge:- (a) Panel mounted Multi-function for voltage, current, frequency, power factor and power Type EM-VIFP -01 set (b) Aluminium bus bar -- 03 Nos. For phase of capacity 400 Amp and 1 Nos 400 Amps for neutral, duly taped in colour coded FRP sleeves. (c) LED Indicating lamps Red, Yellow and blue in colour, complete with lamp holders, 220 volts AC.- 01 Set of 3 (d) Panel wiring with 2.5 Sqmm PVC Sheathed, PVC insulated FR-HR stranded copper conductor cable through MCB DP 10 A mounted on DIN rail. (e) MCCB 4 Pole, 250 Amp, (Ics=100%Icu) 415 V, 36 KA - 01 No (incoming) (f) MCCB 4 Pole, 125 Amp, (Ics=100%Icu) 415 V, 16 KA - 02 No (outgoing) (g) MCCB 4 Pole, 100 Amp, (Ics=100%Icu) 415 V, 16 KA - 03 No (outgoing) Note : (i) Drawing of LT panel shall be got approved from Engineer-in-Charge before placing order for procurement. (ii) Cost of taking down of Panel is deemed to be included under unit rate quoted.
Supply, installing, commissioning and testing of LT outboard panel board Kiosk type (factory made of approved CPRI) made out of CRCA sheet 3.15mm thickness for outer sheet and 2mm thickness for inner sheet dust proof, powder coated from both side as per latest IS/IEC individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and water proof duly supported on 40 x 40 x 6mm angle iron frame, opening arrangement from front & rear both duly fitted with compression cable glands for entry & exit of cables having minimum clearance of 450mm above ground level complete comprising of the following including taking down old U/S LT Panel all as directed by Engineer-in-Charge:- (a) Panel mounted Multi-function for voltage, current, frequency, power factor and power Type EM-VIFP -01 set (b) Aluminium bus bar -- 03 Nos. For phase of capacity 400 Amp and 1 Nos 400 Amps for neutral, duly taped in colour coded FRP sleeves. (c) LED Indicating lamps Red, Yellow and blue in colour, complete with lamp holders, 220 volts AC.- 01 Set of 3 (d) Panel wiring with 2.5 Sqmm PVC Sheathed, PVC insulated FR-HR stranded copper conductor cable through MCB DP 10 A mounted on DIN rail. (e) MCCB 4 Pole, 250 Amp, (Ics=100%Icu) 415 V, 36 KA - 01 No(incoming) (f) MCCB 4 Pole, 100 Amp, (Ics=100%Icu) 415 V, 16 KA - 04 No(outgoing) (g) MCCB 4 Pole, 63 Amp, (Ics=100%Icu) 415 V, 16 KA - 01 No(outgoing) Note : (i) Drawing of LT panel shall be got approved from Enginrrt-in-Charge before placing order for procurement. (ii) Cost of taking down of Panel is deemed to be included under unit rate quoted.
Supply, installing, commissioning and testing of LT panel board outdoor type, cubical type made out CRCA sheet 3.15 mm thick, inner sheet 2.0 mm thick, dust and vermin as per IS/IEC-:61439-1:2011, 61439-2:2011 having thimble and cable entry boxes with cable glands. Panel should individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and water proof duly supported on 40x40x6mm angle iron frame, opening arrangement from front & rear both side duly fitted with compression cable glands for entry and exit of cables having minimum clearance of 450mm above ground level complete comprising of the following including taking down U/S LT Panel as directed by Engineering-in-Charge:- (a) Panel mounted Multi-function for voltage, current, frequency, power factor and power Type EM-VIFP -01 set (b) Aluminium bus bar -- 03 Nos. For phase of capacity 400 Amp and 1 Nos 400 Amps for neutral, duly taped in colour coded FRP sleeves. (c) LED Indicating lamps Red, Yellow and blue in colour, complete with lamp holders, 220 volts AC.- 01 Set of 3 (d) Panel wiring with 2.5 Sqmm PVC Sheathed, PVC insulated FR-HR stranded copper conductor cable through MCB DP 10 A mounted on DIN rail. (e) MCCB 4 Pole, 500 Amp, (Ics=100%Icu) 415 V, 36 KA - 01 No (incoming) (f) MCCB 4 Pole, 160 Amp, (Ics=100%Icu) 415 V, 26 KA - 02 No (outgoing) (g) MCCB 4 Pole, 100 Amp, (Ics=100%Icu) 415 V, 26 KA - 01 No(outgoing) (h) MCCB 4 Pole, 125 Amp, (Ics=100%Icu) 415 V, 26 KA - 01 No (outgoing) (j) MCCB 4 Pole, 63 Amp, (Ics=100%Icu) 415 V, 16 KA - 02 Nos (outgoing) Note : (i) Drawing of LT panel shall be got approved from GE before placing order for procurement. (ii) Cost of taking down of Panel is deemed to be included under unit rate quoted.
Supply, installing, commissioning and testing of LT outboard panel board Kiosk type (factory made of approved CPRI) made out of CRCA sheet 3.15mm thickness for outer sheet and 2mm thickness for inner sheet dust proof as per latest IS/IEC, powder coated from both side, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and water proof duly supported on 40 x 40 x 6mm angle iron frame, opening arrangement from front & rear both duly fitted with compression cable glands for entry & exit of cables having minimum clearance of 450mm above ground level complete comprising of the following including taking down U/S LT Panel all as directed by Engineer-in-Charge:- (a) Panel mounted Multi-function for voltage, current, frequency, power factor and power Type EM-VIFP -01 set (b) Aluminium bus bar -- 03 Nos. For phase of capacity 400 Amp and 1 Nos 400 Amps for neutral, duly taped in colour coded FRP sleeves. (c) LED Indicating lamps Red, Yellow and blue in colour, complete with lamp holders, 220 volts AC.- 01 Set of 3 (d) Panel wiring with 2.5 Sqmm PVC Sheathed, PVC insulated FR-HR stranded copper conductor cable through MCB DP 10 A mounted on DIN rail. (e) MCCB 4 Pole, 250 Amp, (Ics=100%Icu) 415 V, 36 KA - 01 No (incoming) (f) MCCB 4 Pole, 100 Amp, (Ics=100%Icu) 415 V, 16 KA - 05 No (outgoing) Note : (i) Drawing of LT panel shall be got approved from Engineer-in-Charge before placing order for procurement. (ii) Cost of taking down of Panel is deemed to be included under unit rate quoted.
Supply, installing, commissioning and testing of LT outboard panel board Kiosk type (factory made of approved CPRI) made out of CRCA sheet 3.15mm thickness for outer sheet and 2mm thickness for inner sheet dust proof as per latest IS/IEC, powder coated from both side, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and water proof duly supported on 40 x 40 x 6mm angle iron frame, opening arrangement from front & rear both duly fitted with compression cable glands for entry & exit of cables having minimum clearance of 450mm above ground level complete comprising of the following including taking down U/S LT panel all as directed by Engineer-in-Charge:- (a) Aluminium bus bar -- 03 Nos. For phase of capacity 400 Amp and 1 Nos 400 Amps for neutral, duly taped in colour coded FRP sleeves. (b) LED Indicating lamps Red, Yellow and blue in colour, complete with lamp holders, 220 volts AC.- 01 Set of 3 (c) Panel wiring with 2.5 Sqmm PVC Sheathed, PVC insulated FR-HR stranded copper conductor cable through MCB DP 10 A mounted on DIN rail. (d) MCCB 4 Pole, 125/160 Amp, (Ics=100%Icu) 415 V, 36 KA - 01 No (incoming) (f) MCCB 4 Pole, 63 Amp, (Ics=100%Icu) 415 V, 16 KA - 06 No (outgoing) Note : (i) Drawing of LT panel shall be got approved from Engineer-in-Charge before placing order for procurement. (ii) Cost of taking down of Panel is deemed to be included under unit rate quoted.
Supply and fixing in replacement of MCCB 250 Amp rating, (ICS=100% of ICU) 4-pole 415V, thermal adjustable megnetic type breaking capacity 36KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 200 Amp rating, (ICS=100% of ICU)4-pole 415V, thermal adjustable megnetic type breaking capacity 36KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 125 Amp rating, (ICS=100% of ICU) 4-pole 415V, thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 100 Amp rating, (ICS=100% of ICU) 4-pole 415V, thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
Supply and fixing in replacement of MCCB 63 Amp rating, (ICS=100% of ICU) 4-pole 415V, thermal adjustable megnetic type breaking capacity 16KA complete all as specified and as directed.
M&L for stay assembly complete with MS Stay plate 300x300x6mm thick galvanised stay rod not less than 20mm dia 2.15 m long glavanised stay bow with thimble,stay clamp,earth work, cement work, stay wire, loop insulator including taking down U/S stay assembly complete all as specified and as directed.
Supply and fixing in replacement of LED street light fitting 70 watt 230V AC outdoor type with high pressure diecast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and as directed.
Supply and fixing in replacement of LED flood light fittings 120 Watt 230V AC outdoor type with thermal management in multi optics and equipped with IP-66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Supply and fixing in replacement of LED flood light fitings 150 Watt 230V AC outdoor type with thermal management in multi optics and equipped with IP-66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
S&F in replacement LED Bollard light flare fitted with low glare diffuser 12 watt with integrated driver with uniform light distribution complete all as specified and as directed.
M&L for applying one coat of synthetic enamel paint on outer surface of Panel and minor repair of LT Panel including welding work/repair to door/hinges etc as reqd at site complete all as specified and as directed.
M&L for earth pit cover of size 450x450x50mm thick of RCC M-15 Nomnial mix using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm@ 150mm centre to centre both ways,MS handle 10mm dia made to shape complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil omplete all as specified and as directed.
Dismantling fencing wire mesh (Chain link fencing) any type and size complete all as specified and as directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, embedded in concrete, brick work including taking out embedded portion and making good disturbed area and post embedded in ground concrete, brick work masonery etc complete all as specified and as directed.
Supply only chain link fencing made out mild steel galvanized wire of any size or type complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete as specified and as directed.
Supply and fix mild steel section for Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts for post and struts for fencing including cutting top to shape as directed drilling hole notching for wire etc.or flat iron fillet (for securing wire mesh etc)including all necessary drilling bolting,using steel section of grade E-165 (Fe-290).complete as specified and as directed.
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long & dia of shank 5 mm to 10mm long complete as specified and as directed.
M&L for mild steel round bars 10mm dia and over, cut to length, bent to shape required for holding chain link fencing complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified and as directed.
Supply and laying broken stone of gauge 45mm at installation complete all as specified and as directed.
Supply and fixing in replacement of 3 phase volt meter, 0-500 volt digital type square or rectangle type 96 sqmm lamp accurracy glass-1 complete all as specified and as directed.
Supply and fixing in replacement of 3 phase volt meter, 0-200 volt digital type square or rectangle type 96 sqmm lamp accurracy glass-1 complete all as specified and as directed.
Supply and fixing in replacement of indicating lamp, set RYB for phase indication operating 240 volt, 50Hz AC with new one LED panel mounting type complete to match existing one complete all as specified and as directed.
Supply and fixing cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material (Epoxy based) and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and as directed.
Supply and fixing cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material (Epoxy based) and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 120 Sqmm to above complete all as specified and as directed.
M&L for GI strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and as directed.
M&L for copper strip of size 32x6mm as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle complete all as specified and as directed. Note : Cost of insulating saddle for fixing of copper strip on wall/roof/floor etc shall be included in quoted rates.
M&L for Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6.0mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not than 1.5mtr below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 15mm bore GI water pipe medium grade and 40mm bore medium grade GI pipe for protection of earth strip from plate to main switch board, common salt, charcoal dust including testing on completion complete all as specified and as directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost complete.
M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead 4mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I connected to earthing point and testing on completion with and including PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work complete all as specified and as directed.
Taking down unserviceable LED street / security /flood light fittings of any type / wattage / make etc fitted on LT poles, High Mast light poles, building etc for repairing including complete dismantling, checking for repair / replacement of unserviceable parts as required and making the LED light fittings operational to give rated illumination by replacing unserviceable spare parts and refixing the same at existing location or any other location as directed at site and making electrical connections with existing wire complete all as directed. Notes - (i). Cost of taking down carefully from existing position after disconnecting electric connections, sealing cable ends, bringing to MES store yard (If required for repair), is deemed to be included under unit rate quoted. (ii) Cost of supply and fixing of major items required to make the lights serviceable shall be measured and paid separately under item No 54.00 to 56.00 of this schedule. (iii). Cost of items or works not mentioned under item 2.01 to 2.03 and however required to make the lights serviceable will be provided by the contractor without any extra cost to the department and cost thereof shall deemed to be included in the unit rate quoted. (iv) Contractor shall be responsible for day to day repair / Maint works as per schedule and as directed by Engr-in-Charge alongwith all necessary required Tool & Plant & vehicle (for timely repair) to make functional all security/street lights at the station.
Supply and fix in replacement Electronic LED driver suitable for LED street light fitting capacity 30/45/60 Watt installed at site of existing make and specification and as directed.
Supply and fix in replacement Electronic LED driver suitable for LED street light/flood light fitting capacity 60/90/150 Watt installed at site of existing make and specification and as directed.
Supply and fix in replacement surge protection device suitable for LED Street light/flood light any wattage complete all as specified and as directed.
Note for item serial No 54 to 56 : Electronic LED driver should be consist of all safety controll feature like SMPS based constant current supply with lower THD, Output Open / Short Circuit protection, Phase to Phase protection, Over Voltage protection,Surge Voltage protection.
Supply and fixing in replacemnt of sheet moulding compound junction box shock and rust proof, termite resistant, tamper proof , front openable type for single phase, two wire rating of size 250x200x105mm complete with one no. MCB SP 6 Amp including non metallic clamps and GI nut bolts and washers of suitable size and fixed on pole/wall complete all as specified and as directed.
Supply & fixing in replacement multifunctional digital timer switch with inbuilt function for switching on/off street lights according to the rising/setting of the sun with combination function according to astronomical time or fixed preset times including fitting of all connection to existing panel complete all as specified and as directed.
Supply & fixing in replacement Automatic Security light control panel having sheet steel enclosure power coated CRCA sheet suitable for three phase 6 KW rating, outdoor installation, floor mounted, IP 54 protected including making all connections and grouted in cement concrete 1:2:4, type B-1 with foundation should be 100mm above ground level complete with comprising of the following switch gears:- (a) MCB TPN 40 Amp rating - 01 No (b) Multifuctional Digital Timer Switch - 01 No (c) Contactor with nominal current rating 32 Amp TP (d) Outgoing MCB SP with suitable rating - 03 Nos (e) Auto/Manual switch (f) Incoming and outgoing terminal suitable for three phase supply.
M&L for scraping, scratching, cleaning the old paint, preparation of the surface for repainting. Painting LT Pole 09 Mtr long steel tubular pole with two coats of aluminium paint and writing pole Nos. including applying one coat of cement base paint on PCC muff complete all as specified and as directed.
M&L for street light bracket made out of 40mm dia medium grade GI pipe of 1.2m length bent to required shape suitable for fixing street light/security light fitting on Steel tubular pole/RCC pole/building wall including two Nos clamps made out 30mm X 5mm flat with suitable nuts and bolts (clamp type - as per site requirement ) including applying two coats of aluminium paint over a coating of red oxide primer and Taking down of existing unserviceable rusted street light brackets with clamps, nuts and bolts etc complete all as specified and as directed.
Supply and fixing in replacemnt MS clamps including nuts, bolts and washers made out of mild steel flat strip 30 x 5mm thick including cutting, bending, drilling holes in shape and size as per the pole size and fixing with PCC/steel tubular pole for holding of GI brackets for mounting of street lights complete all as specified and as directed.
S&F in replacement 1100 volts grade heavy duty flat service electric cable with stranded aluminium conductor of size 10 Sqmm twin core, weather proof, PVC insulated with inner sheathing of PVC tape and overall PVC sheathed for providing electrical connections to existing security/street lights complete all as specified and as directed.
Supply & fixing in replacement Weather proof flat twin core aluminium conductor cable of size 2.5 Sqmm, 1100 volts grade including dismantling existing unserviceable cable any description and complete all as specified and as directed.
Supply and fixing in replacement of LED street light fitting 30 watt 230v AC Outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and as directed.
Supply and fixing in replacement of LED street light fitting 45 watt 230v AC Outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and as directed.
Supply and fixing in replacement of LED street light fitting 100 watt 230v AC Outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and as directed.
Supply and fixing in replacement of LED street light fitting 120 watt 230v AC Outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and as directed.
Supply and fixing in replacement of LED flood light 100 watt 230v AC Outdoor type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistant complete with driver and lamp complete all as directed at site.
Supply and fixing in replacement of LED flood light 200 watt 230v AC Outdoor type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistant complete with driver and lamp complete all as directed at site.
Supply and fixing in replacement of Post top lantern LED type 30 Watt 230V AC outdoor type with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
Supply and Fixing in replacement MCB single pole 6 Amp-32 Amp for street light junction box/panel including connection complete all as specified and as directed.
Supplying and fixing in replacement MCB single pole 230 volts 50 Hz AC of rating 40 to 63 Amp including connection complete all as specified and as directed.
Supply & Fixing in replacement Power Contactor 63-80 Amp rating 4 pole including all connected accessories with suitable rating like coil / auxiliary Contact etc) as per site requirement and suitable for street light controll panel with all connection complete all as specified and as directed.
Supply & Fixing in replacement Power Contactor 25 to 40 Amp rating single pole including all connected accessories with suitable rating like coil/auxiliary Contact etc) as per site requirement and suitable for street light controll panel with all connection complete all as specified and as directed.
M&L for cutting/Pruning/trimming of tree branches in vicinity of LT over head electric line and to be made free over head line from trees branches for avoid any short circuit between conductor complete including disposal the wastage branches by dumping in low lying area complete all as specified and as directed. Note : (i) Labour / Tools / Ladder / Vehicle for Cutting / Pruning / trimming of tree branches shall be provided by contractor and rate for the same are included in the quoted rate of item.
S&F in replacement Aviation obstruction light luminaries fittings having integral LED aviation light comprising of aluminium housing with polycarbonate enclosure at the top of the pole and making necessary electric connection and fixing arrangement of aviation light complete all as specified and as directed.
S&F Double wall corrugated HDPE pipe of size 40mm outer dia and 32mm inner dia confirming to IS-14930 Part-II including necessary pipe fittings such as couplers, end cpas, bend etc laid in trenches/fixed to wall with suitable clamps for cable protection complete all as specified and as directed.
M&L for rewinding of electric motor upto 2.5 HP capacity with super enamel copper wire of existing gauge including insulation and varnishing, including repair to gear box after dismantling all electrical and mechanical connection from High Mast light, testing and commissioning at site complete all as specified and as directed.
M&L for replacement of high mast wire rope of existing size complete all as specified and as directed.
Ms Kamal Kant Agarwal
M/S S S CONSTRUCTION
M/S United Builders
M/s M S CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .