Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.9 LAccepted-AOC | 1 | Accepted-AOC Lowest | |
| 2 | 2₹9.8 L+₹60,157 (6.52%)Rejected-Finance M S CHANANA ENGINEERS CONTRACTORS AZAD CHOWK FEROZEPUR CANTT FEROZEPUR PUNJAB 152001 | FIROZEPUR | PUNJAB | 152001 | 2 | Rejected-Finance Higher | |
| 3 | 3₹10.0 L+₹76,127 (8.25%)Rejected-Finance RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | 3 | Rejected-Finance Higher | |
| 4 | Rejected-Technical | - | Rejected-Technical No remarks, WLR Sep 20 CE (AF) WAC, Palam Delhi Cantt srl 172 and not enlisted for requisite category |
Tender Value
Refer Docs
Closing Date
29 Mar 2021, 4:00 pmClosed
GE Amritsar
GE Amritsar PIN 143001
REPAIR AND MAINT OF DG SETS INCLUDING COMPLAINTS AND CONNECTED ITEMS OF WATER SUPPLY AT OLD AMRITSAR CANTT
2021_MES_429427_1
GE/ASR-58/2020-21
Open Tender
Civil Works
Item Rate
334 days
GE Amritsar
Class E, Category bi
8 documents required · 8 mandatory
₹500
GE Amritsar
Exempted
15 Jun 2021
13 Mar 2021
30 Mar 2021
13 Mar 2021
29 Mar 2021
15 Mar 2021
Amount
M & L for supply, carrying out B check maintenance repair in 250 KVA Cummins DG set including the replacement of fuel filters, lub oil filters, SLO by pass filters and engine oil as per manufacturer specifications and quantity all as specified and directed by Engineer-in-Charge
M & L for supply, carrying out B check maintenance repair in 160 KVA / 125 KVA Cummins DG set including the replacement of fuel filter, lub oil filter, SLO by pass filter and engine oil as per manufacturer specifications and quantity all as specified and directed by Engineer-in-Charge
M & L for supply, carrying out B check maintenance repair in 100 KVA / Diesel driven pump make Kirloskar DG set including the replacement of fuel filter, lub oil filter, SLO by pass filter and engine oil as per manufacturer specifications and quantity all as specified and directed by Engineer-in-Charge
M & L for supply, carrying out B check maintenance repair in 63KVA / Diesel driven pump make Kirloskar DG set including the replacement of fuel filter, lub oil filter, SLO by pass filter and engine oil as per manufacturer specifications and quantity all as specified and directed by Engineer-in-Charge
M & L for supply, carrying out B check maintenance repair in 35KVA / 25KVA Diesel driven pump make Kirloskar DG set including the replacement of fuel filter, lub oil filter, SLO by pass filter and engine oil as per manufacturer specifications and quantity all as specified and directed by Engineer-in-Charge
M & L for supply, carrying out B check maintenance repair in 10 KVA Diesel driven pump make Kirloskar DG set including the replacement of fuel filter, lub oil filter, SLO by pass filter and engine oil as per manufacturer specifications and quantity all as specified and directed by Engineer-in-Charge
S & Fixing Air cleaner elements as per manufacture in 250 KVA DG sets all as specified and directed by Engineer-in-charge
S & Fixing Air cleaner elements as per manufacture in 160/125 KVA DG sets all as specified and directed by Engineer-in-charge
S & Fixing Air cleaner elements as per manufacture in 100 KVA DG sets all as specified and directed by Engineer-in-charge
S & Fixing Air cleaner elements as per manufacture in 63 KVA DG sets all as specified and directed by Engineer-in-charge
Supply only coolant concentrate for radiator of DG set of any capacity as per manufacture all as specified and directed by Engineer-in-charge
Supply only distilled water for radiator and batteries of DG set
Dismantling, transporting, repair and calibration, testing and commissioning of PT fuel pump for 250 KVA DG set including the replacement of all service kits as specified and directed by Engineer-in-charge
Dismantling, transporting, repair and calibration, testing and commissioning of PT fuel pump for 160/125 KVA DG set including the replacement of all service kits as specified and directed by Engineer-in-charge
S & Fixing in replacement AVR suitable for 250 KVA DG set Make; Kirloskar / Altex
S & Fixing in replacement AVR suitable for 160/125 KVA DG set Make; Kirloskar / Altex
S & Fixing in replacement AVR suitable for 100/63 KVA DG set Make; Kirloskar / Altex
M & L for painting of DG Set complete including alternator and Engine and all area of DG Set of Cap 250 KVA /160 KVA/125 KVAby applying with two coat of synthetic enamel paint heat resistant of approved quality and colour by spray painting followed by two coats of primer after preparation of old paint surface cleaning and scrapping and sticker pasting of MES No., DG set specification, etc all as specified and directed by Engineer-in-charge
M & L for painting of DG Set complete including alternator and Engine and all area of DG Set of Cap 100/63 KVA by applying with two coat of synthetic enamel paint heat resistant of approved quality and colour by spray painting followed by two coats of primer after preparation of old paint surface cleaning and scrapping and sticker pasting of MES No., DG set specification, etc all as specified and directed by Engineer-in-charge
S & Fixing the lead acid battery 12 V DC 180 AH including the initial charge, terminals connector make : Exide / Amaron or equlvant
S & Fixing the lead acid battery 12 V DC 110 AH including the initial charge, terminals connector make : Exide / Amaron or equlvant
M & L in servicing of alternator capacity 250 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units, thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insualation tapes, heating and improving the insualtion of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, replacing both bearings, assembling all removed parts in the alterantor, fixing back into the engine and coupling and carryingout alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load all as specified and directed by Engineer-in-charge
M & L in servicing of alternator capacity 160/125 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units, thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insualation tapes, heating and improving the insualtion of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, replacing both bearings, assembling all removed parts in the alterantor, fixing back into the engine and coupling and carryingout alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load all as specified and directed by Engineer-in-charge
M & L in servicing of alternator capacity 100 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units, thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insualation tapes, heating and improving the insualtion of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, replacing both bearings, assembling all removed parts in the alterantor, fixing back into the engine and coupling and carryingout alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load all as specified and directed by Engineer-in-charge
M & L in servicing of alternator capacity 63 KVA by disconnecting from engine coupling system, complete dismantling of stator and rotor seperately, excitors and rotating rectifier units, thorough cleaning and decarbonising of stator and rotor coils by CTC liquid, checking and renewing the insualation tapes, heating and improving the insualtion of coils as required per the requirements, varnishing the coils and followed by bectol anti rust coating, replacing both bearings, assembling all removed parts in the alterantor, fixing back into the engine and coupling and carryingout alignment accurately, connecting the power cables and AVR system, excitation connections, starting and testing on load all as specified and directed by Engineer-in-charge
M & L for replacement of battery lead 1.25 Mtr long consisting of multistranded copper conductor PVC insulated single core cable of 25 Sqmm size connected with 1 No battery terminal clamp at one end and copper lug at other end all as directed.
S&F Fuel Flexible Pipe of cap 250 KVA ,complete all as specified and directed.
S&F Fuel Flexible Pipe of cap 160/125 KVA ,complete all as specified and directed.
S&F Fuel Flexible Pipe of cap 100/63 KVA ,complete all as specified and directed.
S&F Hose Pipe of cap 250 KVA ,complete all as specified and directed.
S&F Hose Pipe of cap 160/125 KVA ,complete all as specified and directed.
S&F Hose Pipe of cap 100/63 KVA ,complete all as specified and directed.
S&F Fan Belt ,complete all as specified and directed.
Taking down /dismantling complete DG set including alternator of cap 125 KVA and carry out repair from workshop and refixing after complete the job in same location complete all as specified and directed by Engr-in-Charge. Note : (a)The following items measured and paid separtely (b) T&P & any Transportation of minor items to workshop for supply only for the following item No 35 to 44 included in the quoted rate :-
Supply only crank case (block )of dg set as per manufacture complete all as specified and directed by Engr-in-Charge.
Supply only crank as per manufacture complete all as specified and directed by Engr-in-Charge.
Supply only crank shaft as per manufacture complete all as specified and directed by Engr-in-Charge.
Supply only Piston rod as per manufacture complete all as specified and directed by Engr-in-Charge.
Supply only liner as per manufacture complete all as specified and directed by Engr-in-Charge.
Supply only piston as per manufacture complete all as specified and directed by Engr-in-Charge.
Supply only piston ring as per manufacture complete all as specified and directed by Engr-in-Charge.
Supply only head gasket as per manufacture complete all as specified and directed by Engr-in-Charge.
Supply only push rocker as per manufacture complete all as specified and directed by Engr-in-Charge.
Supply only head seal as per manufacture complete all as specified and directed by Engr-in-Charge.
Repair/overhauling of self starter including replacement of armature, carbon brushes, brackets, bearings etc for 24 volt Lucas ,complete all as specified and directed.
Repair/overhauling of self starter including replacement of armature, carbon brushes, brackets, bearings etc for 12 volt Lucas ,complete all as specified and directed.
Repair to AMF panel and wiring for DG Set of cap 125/100 KVA dismantling/opening of complete electric connection incoming and out going and replacement of the defective parts and testing complete after repair on full load for 8 hours ,complete all as specified and directed.(Note - Parts shall be measured and paid for separately )
Dismantling the battery charge alternator from engine, carryingout repairs by complete dismantling and cleaning, renewal of carbon brushes, rectifier kit, diodes, varnishing the coils, replacing bearing, regulator, fixing back in the engine and connecting electrical system complete of 250/160 KVA DG set all as specified and directed by Engineer-in-charge
Dismantling the battery charge alternator from engine, carryingout repairs by complete dismantling and cleaning, renewal of carbon brushes, rectifier kit, diodes, varnishing the coils, replacing bearing, regulator, fixing back in the engine and connecting electrical system complete of 125/100 KVA DG set all as specified and directed by Engineer-in-charge
Dismantling the battery charge alternator from engine, carryingout repairs by complete dismantling and cleaning, renewal of carbon brushes, rectifier kit, diodes, varnishing the coils, replacing bearing, regulator, fixing back in the engine and connecting electrical system complete of 63 KVA DG set all as specified and directed by Engineer-in-charge
Supply and fixing MCCB 4 Pole, 415 V, thermally Adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in- Charge.
Supply and fixing MCCB 4 Pole, 415 V, thermally Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in- Charge.
Supply and fixing MCCB 4 Pole, 415 V, thermally Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in- Charge.
S&F off-load change over switch side handle 415 volts 4 pole 200 Amp including connection complete all as specified and directed by Engr-in-Charge. Make C&S/Havells/Standard
S&F off-load change over switch side handle 415 volts 4 pole 100 Amp including connection complete all as specified and directed by Engr-in-Charge. Make C&S/Havells/Standard
M & L for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised steel strip 32x6 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 15 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed.
Material and labour for servicing and painting /old worn out defective parts of pumping set of cap 10 HP to 20 HP applying two coats of synthetic enameled paint heat resistant of approved quality and colour by spray painting over one coat of primer after preparation of old paint surface cleaning and scrapping etc complete all as specified and directed. Note : Material will be paid separtely for supply only for the following item No from 58 to 62 :-
Supply only Nozzel for pump for 10/12 HP pumping set as per manufacture complete all as specfieid and directed.
Supply only water body for 10 /12 HP pumping set as per manufacture complete all as specfieid and directed.
Supply only ring set for 10 /12 HP pumping set as per manufacture complete all as specfieid and directed.
Supply only raidaitor water of brass make for 10 /12 HP pumping set as per manufacture complete all as specfieid and directed.
Supply only piston for 10 /12 HP pumping set as per manufacture complete all as specfieid and directed.
Attending complaint of DG sets of any type any capacity on required basis excluding items complete all as specified and directed by Engr-in-Charge. Note : Item will be measured paid and separately.
Supply and fixing in repair piston as per manufacture for 10 KVA DG set including connection complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair ring as per manufacture for 10 KVA DG set including connection complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair liner as per manufacture for 10 KV DG set including connection complete all as specified and directed by Engr-in-Charge.
Chanana Engineers & Contractors
TARA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .