Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.7 Cr
EMD Value
₹3.3 L
Closing Date
8 May 2024, 5:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Facilities Management Division, Bangalore
HINDUSTAN AERONAUTICS LIMITED Facilities Management Division, Bangalore
Extension of First Floor for ALH Store at Helicopter Division HAL HC
7008
TENDER NOTICE/NCP/51/23-24/02
Works
Contract Section Civil-FMD-Bangalore
₹0
₹3.3 L
8 May 2024
13 Apr 2024
13 Apr 2024
8 May 2024
Name of the Individual / Firm / Company: * Mandatory
Type of ownership
Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, Contractor registration No etc.,
Address for correspondence:
PAN No.:
Service Tax Registration No
Goods and Service Tax ID No.
Contact details
Please Enter Contact person Name
Pls Enter Mobile No
Registered Contractor
Average annual financial turn over during the last 3 years, ending 31st March 2023 of the previous financial year [ should not be less than 30% of Amount put to tender]
TURN OVER IN Rs.
Pls Enter Turn over in Rupees for all the 3 years
ESI & PF Nos with proof
Remarks if any
Bank(s) details: [Copy of the cheque leaf to be uploaded]
Related Document to be Uploaded to eProcurement Portal (Note Canceled cheque leaf to be uploaded)
Latest Bankers Solvency Certificate from Nationalized/ scheduled Bank issued NOT before 12 months from the last date of Tender submission
Pls Enter Details to 'Name of the Bank' , 'Date of Issue','Value in Rs
Experience of having successfully completed similar works during last 7 years ending last day of previous month. [Latest work experience certificate may be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated cost. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated cost. (iii) ONE similar completed work each costing not less than the amount equal to 80% of Amount put to the tender.
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Please enter Details for Work No 1
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No II
work done
Type of Work: [ Incase of private works the same shall be supported with TDS certificate]
Pls Enter Details for Work No III
Details of person holding the power of Attorney (If different from contact person)
Related Document to be Uploaded to eProcurement Portal
Pls Enter Details for Person holding Power of Attorney
DECLARATION I
DECLARATION II
Pls Accept the Delaration II
Specification
Removing / transporting the surplus excavated earth including debris, vegetation waste etc., to a distance upto 5000m/ outside HAL premises/ to contractor's own yard including loading, unloading, depositing, spreading, levelling, etc., all complete as directed by Engineer-in- Charge.
Earth work in surface excavation for all kinds of soils not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as well as clearing away all grass, vegetation, saplings, shrubs, undergrowth, roots, etc., all complete as directed by Engineer-in- Charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas in all kinds of soft / hard soil for foundations, footings, column pedestals or members as per the drawing etc., (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including removal of vegetation and in-equalities, shoring, strutting for protecting the sides of foundation if required, removing slips or falls in excavation, forming steps in sides of deep excavations and their removal or covering up, levelling, ramming the bottom of excavation, getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m with all labour, tools & tackles, plant & machinery, hire & fuel charges, etc.,all complete as directed by Engineer-in-charge.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas in all kinds of soft / hard soil for foundations, footings, column pedestals or members as per the drawing etc., (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including removal of vegetation and in-equalities, shoring, strutting for protecting the sides of foundation if required, removing slips or falls in excavation, forming steps in sides of deep excavations and their removal or covering up, levelling, ramming the bottom of excavation, getting out and disposal of excavated earth lead upto 50 m and lift from 1.5m to 3m with all labour, tools & tackles, plant & machinery, hire & fuel charges etc., all complete as directed by Engineer-in-charge.
Returning / filling in with useful excavated soil (excluding rock), free from salts, organic or other deleterious matter (Other than black cotton soil & rock etc., in trenches, plinth,sides of foundations etc., spreading in layers not exceeding 20 cm thick, watering, breaking / removing clods exceeding 50 mm, ramming and consolidation of each deposited layer etc., with all labour, tools & tackles, plant & machinery, etc., lead upto 50 m and for all lifts, all complete as directed by the Engineer-in-Charge.
Supplying, mixing and placing plain cement concrete (1:2:4) (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate) of required thickness using 20 mm nominal size down graded hard stone/granite aggregate in accordance with IS 456 in Cills, fillets, coping,etc upto floor five level, including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., but excluding the cost of centering, shuttering and finishing, all complete as directed by the Engineer-in-Charge.
Providing and fixing up to floor five level precast cement concrete solid block of 200mm/100mm with ordinary mix ratio of 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) for walls at all levels, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) and along with necessary formwork, curing, finishing, making or leaving holes & chases and making good etc., all complete as directed by the Engineer-in-Charge.
Supplying, mixing and placing plain cement concrete (1:4:8) (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate) of required thickness using 40 mm down graded hard stone/granite aggregate in accordance with IS 456 in foundations, mass concrete, sub bases and other similar works including formwork, mechanical mixing, transporting, vibrating, consolidation, levelling, curing, dewatering if any, all materials, labour, lead & lift, tools, plant & machinery, keeping concrete well wetted during the curing period and protecting it in extreme weather conditions etc., but excluding the cost of centering, shuttering and finishing, all complete as directed by the Engineer-in-Charge.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary curing, excavation, levelling & dressing & finishing the top smooth, all complete as directed by the Engineer-in-Charge.
Formwork upto 3.5m (Centering and shuttering including strutting, propping etc, and removal of form) for the following RCC members which are defined as below, in fair finished by providing timber, wooden planks, runners / M.S. sheets with all supports, struts, braces, wedges, scaffolds, bracings, ladders, gangways, dressing with oil including M.S. bolts nuts and washers, temporary openings, filleting for a stop, chamfered edges, internal / external splayed, rounded angles or grooves for forming throating including making temporary openings in the forms for pouring concrete etc., all complete as directed by the Engineer-in-Charge for the sub-items mentioned below. Note : Formwork material is contractor's own property and shall be removed after completion of work.
Supplying, straightening, fabricating (cutting & bending), placing in position and binding steel reinforcement of TMT bars of not less than Fe 500 D conforming to IS 1786 for all concrete reinforcment members / works above/below plinth level, including cutting to length, bending to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with mild steel wire (Annealed) not less than 0.9 mm dia or securing with clips, including fixing and bracing, wastage, welding, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it etc., complete all as per specifications, drawings and as directed by the Engineer-in-Charge. Note : a) Only authorized laps, chairs etc. shall be considered for measurement. b) The exposed Reinforcement bars shall be coated with cement slurry.
Providing and laying in position ready mixed or site batched M25 Grade with minimum cement content of 330 kg/m3 design mix cement concrete for reinforced cement concrete work; using coarseaggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, consolidation, levelling, curing, scaffolding, all materials, labour, carriage for all leads & lifts; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge. Note: (i) Mix design to be obtained from Govt. / NABL laboratory for site batching concrete.
All works upto plinth level including necessary openings and packing if any for laying pipes, cables etc.
All works above plinth level upto floor V level including necessary openings and packing if any for laying pipes, cables etc.
Providing and fixing expansion hold fasteners with threaded dia of 6mm on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc all complete as per the architectural drawings and the directions of engineer-in-charge .
Providing and fixing Ceramic glazed wall tiles/Vitrified tiles/Anti skid/ Matt finished conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and set & jointing with neat grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete , including machine cutting, curing etc., all complete as directed by the Engineer-in-Charge. Note : Quoted rate shall be inclusive of screed, pointing etc.
Supplying, fabricating and fixing second class teak wooden plain, solid, straight chowkats and frames of doors ,windows and other frames, wrought framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed to wall or in position with hold fast lugs or with dash fasteners of required dia & length etc., all complete as directed by the Engineer-in-Charge. Note: The timber in contact with masonry shall be treated with anti-termite paint. Hold fast lugs or dash fastener shall be paid separately.
Providing and fixing Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading to the windows, ventilators,etc all complete as per the architectural drawings and the directions of engineer-in-charge .
Providing, fabricating and fixing 35mm thick flush door shutters for main entrance conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood & lipping with 2nd class teak wood battens 25 mm minimum depth on all edges and well matched commercial 3ply veneering with vertical grains or cross bands including ISI marked Stainless Steel butt hinges with necessary screws and face veneers on both faces of shutters and provision of rebates,suitable blocks for taking mortice locks, latches or other fittings, fitting to frames/chowkats etc., all complete as directed by the Engineer-in-Charge. Note : Fittings / hardware shall be paid separately.
Providing, fabricating and fixing 30mm thick flush door shutters for Toilet entrance conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood & lipping with 2nd class teak wood battens 25 mm minimum depth on all edges and well matched commercial 3ply veneering with vertical grains or cross bands including ISI marked Stainless Steel butt hinges with necessary screws and face veneers on both faces of shutters and provision of rebates,suitable blocks for taking mortice locks, latches or other fittings, fitting to frames/chowkats etc., all complete as directed by the Engineer-in-Charge. Note : Fittings / hardware shall be paid separately.
Providing and fixing 12mm dia chromium plated brass curtain rod (towel rail) having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary, including necessary screws, plugs etc.,all complete as directed by the Engineer-in-Charge.
Providing and fixing M.S. grills of required pattern in openings/ wooden frames of windows, Ventilators etc. with rawl plugs screws, ends of bars shouldered and/or riveted, welded etc., of approved design using MS structurals such as flats, angles, round/square bars etc., including necessary cutting, welding, embedding in concrete, masonry etc.,including priming coat with approved steel primer all complete as directed by the Engineer-in-Charge.
Supplying and fixing the 40x5 mm flat iron hold fast 40 cm long of approved make and design to door with all required screws, bolts, nuts, washers etc including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) all complete as directed by the Engineer-in-Charge.
Supplying and fixing the Polished (bright finished) brass barrel type tower bolts 250 mm long X 10 mm with barrel of extruded sections of brass, of approved make and rolled or drawn brass bolt, design to door with all required screws, bolts, nuts, washers etc., conforming to IS 204 (Part 2) all complete as directed by the Engineer-in-Charge.
Providing and fixing bright finished brass mortice latch and lock of minimum 4 levers, vertical type, and a pair of 100mm lever brass handles of approved quality, polished bright of approved manufacture to door with all necessary screws, bolts, nuts and washers of approved manufacture, etc., all complete as directed by Engineer-In-Charge.
Providing and fixing Polished (bright finished) extruded brass handles fabricated type 125 mm long with screws, conforming to IS 208 and with continuous plate to door with all necessary screws, bolts, nuts,etc all complete as directed by Engineer-In-Charge.
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete as directed by Engineer-In-Charge.
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete as directed by Engineer-In-Charge.
Providing and fixing aluminium sliding door bolts (Aldrop) 250 mm long X 16mm, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc.all complete as directed by Engineer-In-Charge
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame, all complete as directed by the Engineer-in-Charge.
Providing and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels, including provision of internal wood lipping, rebates, suitable blocks for taking mortice locks, latches or other fittings, fitting to frames/chowkats etc., conforming to IS: 14856, all complete as directed by the Engineer-in-Charge.
Providing & Fixing decorative high pressure 1.0mm thick laminated sheet of plain / wood grain in gloss / matt/ suede finish on one side with high density protective surface layer and reverse side of adhesive bonding quality and other side with painting conforming to IS : 2046 Type S, including cost of adhesive of approved quality, all complete as directed by the Engineer-in-Charge.
Providing and fixing zinc alloyed (white powder coated) Touch lock for UPVC/Aluminium sliding window with necessary screws etc. all complete as per the architectural drawings and the directions of Engineer-in-charge .
Providing and fixing stainless steel ( Grade 304) railing of approved size/design by welding etc. made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.), all complete as directed by the Engineer-in-Charge.
Supplying, mixing, laying 40 mm thick plain cement concrete flooring (1:2:4) using 20 mm nominal size graded aggregates in sub bases, floors and pavings etc., finished with a floating coat of neat cement, including cement slurry, including consolidation, necessary formwork, curing, materials, labours, tools and tackels, plants etc.,but excluding the cost of nosing of steps etc, all complete as per specifications and as directed by the Engineer-in-Charge.
Providing and laying Double Charged vitrified floor tiles polished finish size of tile Size of 600 X600 mm or nearest available size in floors over a screed of cement mortar (1:4) 20 mm thick for Paper Joint ( Thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 course sand), including grouting the joints with grey cement slurry @ 3.3 Kg/Sqm including grouting the joints with white cement and matching pigments etc. all, complete as directed by he Engineer in charge.
Providing and laying Glazed vitrified tiles Matt/ Anti skid polished finish size in floors as indicated below for Paper Joint of tile size of 600 X 600 mm ( Thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 course sand), including grouting the joints with grey cement slurry @ 3.3 Kg/Sqm including grouting the joints with white cement and matching pigments etc. all, complete as directed by he Engineer in charge. Note : Quoted rate shall be inclusive of screed, pointing etc.
Providing and laying Vitrified tiles in Skirting over a screed of cement mortar (1:3) -Size of Tile 600x600 mm or nearest size available (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. all, complete as directed by he Engineer in charge.
Providing and laying flamed finish Granite stone of Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent colour flooring in required design and patterns, for steps including threads & risers in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing, round nosing etc. all complete as specified and as directed by the Engineer-in-Charge.
Providing, fixing, testing and commissioning single socketed pipes of 110mm dia, on wall face unplasticised Rigid PVC rain water pipes of 6 kg/cm² SWR grade and of approved make conforming to IS : 13592 Type A, including jointing together with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion and all necessary fittings & specials, bends, branches, sockets, clamps, pipe cutting and wastages, cutting and making good the walls, connecting to existing lines etc., along with removal of existing rain water pipes, all complete as directed by the Engineer-in-Charge.
Providing, applying and laying 12 mm thick cement plaster work in for internal/ External areas of Ceilings, Chajjas etc in CM(1:4) including forming grooves n.exc 10mm wide and n.exc 10mm deep as per requirement as directed including preparation of surface by hacking etc., at all levels with necesary materials, labour, scaffoldings, curing, tools and tackles, plants etc., threading if any as directed, all complete as directed by the Engineer-in-Charge.
Providing, applying and laying cement mortar (1:6) plastering 15 mm thick on brick/solid blocks/concrete surfaces, finished even and smooth with trowel for Internal/External walls etc., including supply and fixing of hexagonal chicken mesh minimum 150 mm wide having opening 20 mm x 20 mm of 26 gauge at juncitons of concrete & brick work or between different material, including making grooves as per the requirement n.exc 10mm width and n.exc 10mm deep with necesary materials, labour, scaffolding, curing, tools and tackles etc., at all heights, all complete as directed by the Engineer-in-Charge.
Providing, applying and laying 18 mm thick cement plaster work in two coats for external areas as directed. First coat 12 mm thick in cement mortar (1:5) made rough to recieve top coat, second coat 6 mm thick in cement mortar (1:6) , final surface finished with a floating coat of neat cement after necessary preparation of surface, at all levels including supply and fixing of hexagonal chicken mesh minimum 150 mm wide having opening 20 mm x 20 mm of 26 gauge at juncitons of concrete & brick work or between different material, with necesary materials, labour, scaffoldings, curing, tools and tackles, plants etc., threading if any as directed, all complete as directed by the Engineer-in-Charge.
Painting newly plastered external surfaces with two or more coats applied at 1.43 litre/10 sqm/ as per manufacturer specifications of 100% premium acrylic emulsion paint having VOC less than 50 grams/ litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint with silicon additives of approved make, colour, shade, tint & pattern at all levels, over and including a coat of approved acrylic primer including preparing the surface by removing loose dirt and any organic growth, filling of cracks, necessary scaffolding etc., all complete as directed by the Engineer-in-Charge. Note: The paint shall have anti-algal, anti-fungal, UV resistant & anti-tarnishing qualities with 100% acrylic base and silicon or elastomeric additives.
Painting Wooden surfaces of any description with two coats of synthetic enamel paint conforming to IS 2932, of approved colour and manufacture over a coat of primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content,with ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre including preparation of surface by rubbing with fine grade of abrasive paper to ensure smooth and even surface, applying knifing paste filler putty before painting the first coat etc., all complete as directed by the Engineer-in-Charge.
Painting Steel surfaces of any description with two coats of synthetic enamel paint of approved colour,brand and manufacture to give an even shade, including preparation of surface by rubbing with fine grade of abrasive paper to ensure smooth etc., all complete as directed by the Engineer-in-Charge.
Painting newly plastered interior surfaces with two coats of premium acrylic emulsion paint of interior grade having VOC (Volatile Organic Compound) content less than 50 grams/ litre conforming to IS 15489, of approved make, brand, colour, shade, tint, manufacture & pattern at all levels, including preparing the surface by removing loose dirt and any organic growth, smoothening the surface by using suitable emery paper, filling crevices and finishing even and smooth by providing and applying white cement based putty of average thickness of 1mm in 2 coats of approved brand and manufacture over the plastered wall surface and followed by the applying priming coat with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With water thinnable cement primer on applied putty having VOC content less than 50 grams/litre, necessary scaffolding etc., all complete as directed by the Engineer-in-Charge.
Disconnecting the existing overhead PVC water storage tank of any size including discoonecting the existing water supply line and removing from the terrace, shifting to ground level or to the maintainance department as per direction of Engineer-in-charge.
Demolition of cement concrete work of description of nominal concrete ratio of 1:3:6 or rich mix (even design mix) in any position manually/ by mechanical means using pneumatic tools, breaking to pieces of any thickness or volume, if necessary and disposal of demolished/ rubbish/ unserviceable/ dismantled or waste material (Except saleable materials) by mechanical transport outside HAL upto a total lead of 10.05 kms for all lifts, all complete as directed by the Engineer-in-Charge.
Demolition of reinforced cement concrete work of any description and in any position manually/ by mechanical means using pneumatic tools, breaking to pieces of any thickness or volume, if necessary and stacking servicable and unservicable materials seperately and disposal of demolished/ rubbish/ unserviceable/ dismantled or waste material (Except saleable materials) by mechanical transport outside HAL upto a total lead of 10.05 kms for all lifts, all complete as directed by the Engineer-in-Charge.
Demolition of existing brick masonry work, built in cement mortar manually/ by mechanical means of any description at any height and position with requried scaffolding etc., including stacking of serviceable material and disposal of demolished/ unserviceable material (Except saleable materials) outside HAL for a lead upto 10.05 kms for all lifts, all complete as directed by the Engineer-in-Charge.
Providing and fixing, testing and commissioning 8 mm dia C.P. / S.S. Jet ( health faucet ) with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved with necessary fittings, all complete as directed by the Engineer-in-Charge.
Providing and fixing of toilet paper holder of C.P brass type all complete as specified and directed by EIC.
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets embedded in cement mortar (1:3), connecting the waste pipe to floor trap with all necessary fittings and accessories like 32 mm dia semi-rigid PVC waste pipe(concealed in the wall) including PVC waste fittings, clamps etc all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing 600x450 mm beveled edge mirror of min. 4mm thick superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing White Vitreous China Wash basin of size 630x450 mm or nearest available size of approved make with a pair of 15 mm C.P. brass pillar tap of approved model & make, C.I. brackets, 32 mm C.P. brass waste fitting, 32 mm dia semi-rigid PVC waste pipe, including painting of fittings and brackets, cutting and making good the walls, connecting to floor trap and with all necessary fittings and accessories etc. wherever require all complete as directed by the Engineer-in-Charge.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, all complete as directed by the Engineer-in-Charge.
Providing, fixing, testing and commissioning trap ( floor trap ) of approved make with 100 mm inlet and 75 mm outlet of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors , connection with PVC soil / waste pipe, necessary 150 mm thick cement concrete (1:2:4) for embedding the trap,etc.,all complete as directed by the Engineer-in-Charge.
Providing and fixing of ball valve (brass) 25 mm nominal bore dia, of approved quality, High or low pressure, with plastic floats, screwed for iron pipe or brass ferrule and fixed,including necessary fittings i.e flynut, etc., all complete as directed by the Engineer-in-Charge.
Providing and placing in position at terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes.
Supplying, jointing, testing and commissioning, approved make GM body gate valves with C.I wheel and screwed ends etc. complete all as directed by the Engineer-in-Charge.
Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms fixed to the health faucet, all complete as directed by the Engineer-in-Charge.
Providing and fixing Concealed Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, fixing the pipe with clamps at 1.00 m spacing, necessary reducers, tank adaptors etc. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints and making good the walls etc. complete as per direction of Engineer in Charge.
15 mm dia
20 mm dia
25 mm dia
32 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
40 mm dia
Making connection of drain or sewer line with existing manhole including breaking/cutting into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with C.M 1:3 ( 1 cement : 3 caorse sand ), finished with a floating coat of neat cement and making necessary channels for the drain etc all complete as directed by the Engineer-in-Charge.
Providing, fabricating and fixing aluminium work for ventilators (Min. thickness of powder coating 50 microns) made up of aluminium extruded sections 63.5 X 38.1 X 1.7 weight n.less than 0.9Kg/m conforming to designaton 63400 of IS 1285 and of approved make, doors, windows of Min. thickness of powder coating 50 microns made up of aluminium extruded sections conforming to designaton 63400 of IS 1285 and of approved make comprising of the following: a) Top, bottom and lock side sections of the shutter shall not be less than (39.4 x 17.7 x 1.2) mm and weighing not less than 0.43 kg/m. b) Interlock side section of the shutter shall not be less than (39.4 x 17.7 x 1.2) mm and weighing not less than 0.51 kg/m. c) Top and side sections of the frame shall not be less than (91.8 x 31.75 x 1.5) mm and weighing not less than 0.98 kg/m to accomodate the shutter section. d) Bottom section of the frame shall be with gutter and not less than (91.8 x 45.5 to 37.5 x 1.5) mm and weighing not less than 1.57 kg/m. and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. e) Shutters are to be provided with minimum 5 mm thick plain glass conforming to IS 2835 for two shutters and stainless steel fly proof mesh for one shutter fixed with good quality tapered aluminium interlocking screwless snap on type glazing clip not less than 0.9 mm thick.
Aluminium work for shutters of doors, windows Powder coated aluminium windows (minimum thickness of powder coating 50 micron) & ventilators in moving position including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) all complete as per the architectural drawings and the directions of engineer-in-charge .
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) along with EPDM rubber / neoprene gasket etc. all complete as per the architectural drawings and the directions of engineer-in-charge .
Providing and laying Integral cement based water proofing treatment With average thickness of 120 mm and minimum thickness at khurra as 65 mm. including preparation of surface as required for treatment of roofs, (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge . Note: (i) A performance guarantee bond for 5 years on non-judicial stamp paper of Rs. 200/- shall be given by the contractor. The 10% of completed value of this item shall be dedcuted as defect liability deposit and the same shall be returned after sucessful completion of 5 years from the date of completion of contract / project as a whole. (ii) Plan area shall be measured for payment. (iii) The quoted rate shall be for the entire work and nothing extra shall be paid on this account.
Supplying and Fixing of Curvilinear Urinal Partitions Plates/wall made out of 8mm thick glass with frosting and fixed to the walls with SS fittings of size 900 H and 450mm W at requisite levels as per the manufacturers instruction including necessary screws, fittings and fixures etc as directed by EIC.
Supplying, laying, testing and commissioning the following dia PVC pipes of 6 kg/cm² SWR grade and of approved make with rubber ring joints conforming to IS 5382, jointed together with solvent, in trenches and floors, including all necessary fittings & specials, bends, branches, sockets, pipe cutting and wastages, cutting and making good the floors etc., all complete as directed by the Engineer-in-Charge
75 mm dia
110 mm dia
Providing and fixing (Jaguar make) C.P liquid soap holder with dispenser of available size and standard shape with bracket of the same materials with snap fittings of approved quality and colour, including cutting and making good the walls etc., all complete as directed by the Engineer-in-Charge.
Providing and fixing (Jaguar make) C.P brass Angle cock with all necessary fittings along with washers,leak proof rubber gasket arrangement etc and packing with white cement, all complete as directed by the Engineer-in-Charge.
Providing and fixing Wall mounted White Vitreous china Water Closet (Hindware or Jaguar) with ISI marked, auto close white solid plastic seat and lid with concealed S.S flush valve fixed over steel plate, with suitable stop cock, angle cocks, Health faucets etc., with all connecting fittings and fixtures to make it operational completely, including cutting and making good the walls and floors wherever required complete as per direction of Engineer-in-charge.
Rupees One Crore Thirty Three Lakh Twenty One Thousand Eight Hundred Twenty and Ninety Five Paise Only
Supply, fixing on ceiling, testing & commissioning of surface mounting type square LED lighting fixture of wattage not exceeding 36watt made out of white powder coated CRCA housing/ aluminium housing, front frame with translucent /polycarbonate cover including control gear. The luminaire should have Lumen efficacy ≥100 lm/watt and lumen output not less than 3600lumens with PF >0.9 and Colour temperature shall be ≥5700K operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections and other standard accessories complete in all respects and as directed by Engineer incharge. LED used in the lighting fixtures should be one of the approved make. LM79 certification for luminaires & LM80 certificate for LED shall be produced.The LED Light fixture shall be of Crompton model no:LCTLSNE-36-FO-CDL /Equivalent model in other approved makes luminaries which meets the above technical specification. LED used in the luminaire should be one of approved make as per approved make list of HAL.
Supply and fixing on ceiling testing & commissioning of round type Surface/recess mounted LED downlighter with PDC aluminium housing and high translucent frosted plastic diffucer makes it a robust luminaire, wattage not less than 18W LED lighting fixture, lumens efficiency ≥ 100lm/w at luminaire level, effficent heat sink, Colour temprature shall be ≥5700K, operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V. 79 certification for luminare & LM80 certificate for LED shall be produced. including control gear, power factor of control gear shall be >0.90. Crompton model no:LCDSPLN-S-18-CDL/Equivalent model in other approved makes luminaries which meets the above technical specification. LED used in the luminaire should be one of approved make as per approved make list of HAL.
Supply and fixing on existing wall/ceiling/frame work, testing & commissioning of surface mounting, water proof industrial luminaire with polycarbonate housing and diffuser suitable for 1X18W/20W T8 LED Tube light (four feet) Luminaries with minimum lumens output of 1600 lumens, operating on single phase 230V 50Hz AC supply, built-in electronic driver, Other standard accessories including necessary inter-connections , complete in all respects and as directed by engineer-in-chage. The LED tube & batten shall be of Crompton IPFC121LT8 /Equivalent model in other approved makes luminaries which meets the above technical specification. LED used in the luminaire should be one of approved make as per approved make list of HAL.
Supply, fixing directly to the ceiling/wall using suitable mounting arrangements testing & commissioning of surface mounting Decorative type 10W LED mirror light fitting, including driver, the driver shall have PF >0.9 and Colour temprature shall be >5700K, THD <20% operating on single phase 230V voltage 50 Hz AC supply with voltage range 140-270V including necessary interconnections between driver and lighting fixtures complete in all respect and as directed by EIC. The lighting fixture shall be Bajaj make Model-BCLSB 10W WH/Equivalent make in other approved makes.
Supply & fixing on existing MS hook 1200mm sweep, Ceiling fans complete with blades, down rods, and accessories, 230V single phase 50Hz AC supply. Minimum air delivery 210cu.m/min with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) complete, erected in position with necessary flexible copper leads of required colour and with canopy, down rod 300mm length, necessary rubber bushings, clamps nuts,bolts etc., complete in all respects and as directed by Engineer-in-charge.
Supply, installation, testing & commissioning of 300mm dia 900 rpm heavy duty exhaust fan of any approved make with louvers, connecting cord with 6A, 3 pin plug top and with all necessary accessories, including making wall openings and replastering to smooth finish with matching paint etc., complete in all respects and as directed by Engineer-in-charge.
Supply, fixing, testing & commissioning of the following factory built powder coated Double door MCB/MCCB DB of any approved make fabricated out of M.S. sheet steel enclosure & necessary cutouts for operating the MCB knobs & comprising of 200 amps tinned copper busbars & earthing bus with tapped holes including internal wiring with stranded copper PVC wires or suitable size copper strips etc. & fixing the DB in flush with wall/ on wall as per site requirement with necessary M.S. angle supports, chipping the wall and replastering to smooth finish etc., wherever required as per site condition, complete in all respects, as directed by Engineer-in-charge and comprising the following as detailed below:
6 way (4 + 18), Double door Horizontal MCB DB
6 way (4+18) Double door VTPN MCCB DB
63 amps. ratings, TP MCB, "C" curve, 10 KA breaking capacity.
32 amps. ratings, 4P MCB, "C" curve, 10 KA breaking capacity.
32 amps. ratings , TP MCB, "C" curve, 10 KA breaking capacity.
63 amps. ratings , TP MCB, "C" curve, 10 KA breaking capacity.
125 A, 415V 36KA, FP MCCB
10 amps. ratings , SP MCB, "C" curve, 10 KA breaking capacity.
Wiring for light point / fan point / exhaust fan point/call bell point from nearest switch box with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, fan regulator, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (as per detailed CPWD specifications for Group C wiring)
Wiring to single light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to two light point controlled by 1 No 6A, 250V gr. flush type modular SP switch complete in all respects.
Wiring to fan point controlled by 1 No. 6A, 250V gr. flush type modular SP switch including providing 1No box type MS Fan hook in ceiling whereever required, 2 module type electronic five stepped speed regulator etc., complete in all respects.
Wiring to exhaust fan point using 6A, 250V gr. flush type modular SP switch housed along with other lighting switches/separate switch box if required and 3pin 6A, 250V gr. modular type socket housed near the exhaust fan complete in all respects.
Wiring to Staircase light point controlled by 1 No 2 way 6A, 250V gr. flush type modular SP switch.
Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required(Wiring from Distribution board to Switch box and Switch box to Switch box)
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 x 10 sq. mm + 2 x 6 sq. mm earth wire
4 x 16 sq. mm + 2 x 6 sq. mm earth wire
Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sm. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
6A one-way flush type modular SP switch.
16A one-way flush type modular SP switch.
6A, 3 pin flush type socket outlet.
16A, 3 pin flush type socket outlet.
Supplying and fixing following Modular base & cover plate (coloured or white as decided by OIC/EIC) on existing modular metal boxes etc. as required.
3 Module
6 Module
Supplying and fixing of follwing size GI box in flush with wall including cutting the wall and making good finish with same.
Modular GI box for 3 module
Modular GI box for 6 module
Supply & laying in the already excavated cable trench/fixing on wall/duct wall with necessary M.S clamps /on tray/ encasing in pipes etc., testing & commissioning of 3.5 CX 70 Sqmm size XLPE insulated Aluminium(Al)conductor 1.1KV gr., earthed Armoured(Arm) U.G cables as amended upto date as directed and as per technical specification and as detailed below. (Note:- Excavation, sand & Brick Protection, concrete cutting, reconcreting, casing pipes will be measured separately.)
Supplying and making end termination with brass compression gland and aluminium/Copper lugs for 3.5C x 70 Sqmm. size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
Earthing
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying & laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Rupees Six Lakh Seventy Five Thousand Seven Hundred Eighty Nine and Sixty Three Paise Only
Rupees One Crore Thirty Nine Lakh Ninety Seven Thousand Six Hundred Ten and Fifty Eight Paise Only
Approximate Amount Put to Tender
BELOW
Rupees Twenty Five Lakh Nineteen Thousand Five Hundred Sixty Nine and Ninety Paise Only
Rupees One Crore Sixty Five Lakh Seventeen Thousand One Hundred Eighty and Forty Eight Paise Only
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
TN51.pdf
TENDER_DOCUMENT • 2.72 MB
177CHECKLIST.pdf
TENDER_DOCUMENT • 0.17 MB
177PQ.xls
TENDER_DOCUMENT • 0.36 MB
177PBF.pdf
TENDER_DOCUMENT • 0.63 MB
177PB.xls
TENDER_DOCUMENT • 0.35 MB
electricaldrawing.pdf
TENDER_DOCUMENT • 1.27 MB
177PQF.pdf
TENDER_DOCUMENT • 0.21 MB
177UNDERTAKING.pdf
TENDER_DOCUMENT • 0.55 MB
177ECSForm.pdf
TENDER_DOCUMENT • 0.46 MB
177Amd.pdf
TENDER_DOCUMENT • 0.51 MB
177TBF.pdf
TENDER_DOCUMENT • 3.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .