Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | ₹1.4 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.4 Cr+₹2.0 L (1.42%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹1.4 Cr+₹2.0 L (1.42%) | L2 | Rejected-Finance Other than being lowest |
| 3 | L3₹1.5 Cr+₹3.6 L (2.53%)Rejected-Finance | ₹1.5 Cr+₹3.6 L (2.53%) | L3 | Rejected-Finance Other than being lowest |
| 4 | Rejected-Technical SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | - | - | Rejected-Technical Not Meeting eligibility criteria |
| 5 | Rejected-Technical 1446 ELITE ENTERPRISES NORTH SOLAPUR NEAR SUSHIL MARATHI SCHOOL SOLAPUR MAHARASHTRA 413004 | SOLAPUR | MAHARASHTRA | 413004 | - | - | Rejected-Technical Not Meeting eligibility criteria |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
26 Oct 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
MANNING AND OPERATION OF MEENA RAW WATER PUMP HOUSE INCLUDING MAINT OF EXTERNAL RAW WATER SUPPLY LINE, OH RAW WATER TANK AND INTERNAL RAW WATER SUPPLY PIPE LINE AND ASSOCIATED WORKS AND REPAIR /ROUTINE MAIENTENANCE OF RO PLANT, WATER SUMPS AND ITEMS
2024_MES_679389_1
8602/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) NOFRA
Class B
category a (ii) and c (vii)
7 documents required · 7 mandatory
₹1,000
GE (NW) NOFRA
₹2.2 L
Yes
17 Dec 2024
14 Oct 2024
28 Oct 2024
14 Oct 2024
26 Oct 2024
21 Oct 2024
14 Oct 2024 - 19 Oct 2024
Amount
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cable /Laying of pipe/erection of pole/stay pit and and getting out in hard/dense soil complete all as specified.
Returning filling in , including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified.
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified.
Material & labour for PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) for filling in hard standing/ plinth protection of semi under ground tank and suport to water supply line including necessary formwork complete all as directed by Engineer-in-Charge.
Material & labour for repair to broken brick masonry valve pit of approx size 0.75 x 0.75 x 0.75 mtr to 1.1 x 1.1 x 1.1 mtr as under completed all as specified and directed : i) Taking down old internal and external plaster and rendering 15mm thick in CM (1:4) and finished fair and even. ii) Demolition of existing PCC coping and providing 50mm thick PCC 1:2:4 type B-1 copping including necessary formwork. iii) Providing 4 mm thick MS sheet cover with both side openable of suitable size with 45mm x 45mm x 6mm thick angle iron frame embeded in PCC coping with required hold fasts , 2 Nos MS heavy duty hinges on each side and 2 Nos lifting handle including in built locking arrangement including lock and key and and applying two coats of synthetic black enamel paint over a coat of red oxide primer iv)Excavation in any type of soil, earth work in any type of soil as per site requirement. v) Removing debris and surplus soil outside MD land
Material & labour for attending complaints of underground pipe line leakage of 100 mm to 150 mm bore pipe embeded upto 2 mtr depth from GL including excavation and earth work in any type of soil/ hard standing/ under road including welding work and labour charges complete all as specified and directed by Engr in Charge. Note : Any pipe/ pipe fittings/rubber packing/any type of joint required for stopping the leakage up to 5 mtr length of pipe included in the above quoted rate.
Material & labour for attending complaints of underground pipe line leakage of 40 mm to 80 mm bore pipe embeded upto 2 mtr depth from GL including excavation and earth work in any type of soil/ hard standing/ under road including welding work and labour charges complete all as specified and directed by Engr in Charge. Note : The cost of pipe/ pipe fittings/rubber packing/any type of joint required for stopping the leakage up to 5 mtr length of pipe shall be included in the above quoted rate.
Material & labour for attending complaints in leakage of rising pipe line of 40 mm to 50 mm bore in high rising bldg upto G+15 including stopping leakage ,providing suitable size GI clamp,welding work and labour charges complete all as specified and directed by Engr in Charge. Note :The cost of fittings such as tee, socket, union , welding work, clamps, reducer and other minor parts shall be included in the quoted rate. Only pipe will be measured and paid separately.
Supply & fixing in repairs GI tubing medium grade with all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc fixed to walls and ceilings with suitable size GI clamps or laid in floors, trenches in the bldg of height upto G+15 complete all as specified and directed by Engineer-in-Charge for the following sizes:-
40 mm bore
50 mm bore
80 mm bore
100 mm bore
Supply and Fixing in repairs gun metal gate valve with iron wheel head ISI marked screwed both ends for GI pipe complete all as specified and directed by Engineer-in-Charge for the following sizes:-
40 mm bore
50 mm bore
80 mm bore
Supply and Fixing in repair sluice valve, cast iron body ISI marked flanged end drilled and non rising type brass spindle with long body, class P N 1.6, conforming to IS 14846 of 2000 including flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water in valve chamber all as specified and directed for following sizes:-
80 mm bore
100 mm bore
Supply and Fixing in repair PVC float valve (ISI marked ) high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed. ( Minimum weight 40mm- 690 Grams 50mm- 830 Grams ) complete all as specified and directed by Engineer-in-Charge for the following sizes:-
40mm bore
50mm bore
Supply & fixing in repairs rotational moulded polyethylene water storage tank 5000 Ltr capacity,three layer (cylindrical vertical with closed top) including all connections for inlet, outlet, over flow and wash out etc hoisted and fixed in position in High rise building upto G+15 all as specified in SSR Part-I including approved PVC cover with locking arrangement complete all as specified. fixed in position complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repairs rotational moulded polyethylene water storage tank 2000 Ltr capacity,three layer (cylindrical vertical with closed top) including all connections for inlet, outlet, over flow and wash out etc hoisted and fixed in position in High rise building upto G+15 all as specified in SSR Part-I including approved PVC cover with locking arrangement complete all as specified. fixed in position complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs PVC polythene water storage tank lid (Cover) of any capacity including locking arrangement complete as specified and directed by Engr-in-Charge.
Taking up old rusted existing Meena STP board of size 6' x 3' and material and labour for new Glow Sign Board showing "MEENA RAW WATER PUMP HOUSE" with radium letter of appropriate size of complete length of gate alongwith two leg and Supply and Fixing angle frame of of suitable size complete all as specified and directed.
Supply & fixing in repairs rotational moulded polyethylene water storage tank 3000 Ltr capacity,three layer (cylindrical vertical with closed top) including all connections for inlet, outlet, over flow and wash out etc hoisted and fixed in position in High rise building upto G+15 all as specified in SSR Part-I including approved PVC cover with locking arrangement complete all as specified. fixed in position complete all as specified and directed by Engineer-in-Charge.
Supply and fixing post top lantern LED type 40 watt, lumens 100lm/ Watt, 230 Volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant including driver and lamp complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED flood light 120 watt, lumens 100lm/ watt, 230 Volts, AC, outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete all as specified and directed by Engineer-in-Charge.
Material & labour for earthing complete with G .l earth plate electrode 600 x 600 x 6 mm thick burried directly in ground vertically (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50m, including PCC chamber made out of PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) with pre- cast RCC 1:2:4 cover reinforced with XPM jali not less than 4 Kg /Sqm with handle , watering arrangement with funnel internally secured with wire mesh, 20 mm bore medium grade GI pipe for watering, 40 mm bore light grade Gl pipe for lead protection including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified and indicated including testing on completion as directed by Engineer-in-Charge.
Supply and fixing in repairs 100 mm bore CI foot valve ISI marked along with screen filter of size sewage collection tank/ treated water sumpas specified and directed by Engineer-in-Charge.
Material and labour for attending and rectification of Raw water supply complaints mentioned below as directed by Engineer-in-Charge. Note : (a) The rate quoted shall including providing scaffolading as per site requirement for rectification of complaint. (b) Necessary complaint book shall be provided and maintained by the contractor, complaint slip shall be deposited very next day in the complaint cell of NOFRA w/s duly signed by the occupant (c) Rates for minor fittings and parts are deemed to be included in the quoted item rate however pipes, valves, PVC connection shall be measured and paid seperately under relevent items.
Internal complaint (in side Room) Including Flush tank Cleaning 2 Nos
External complaint upto 4th floor
External complaint upto 8th floor
External complaint upto 12th floor
External complaint upto 16th floor
Supply & fixing GI tubing medium grade with all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc fixed to walls and ceilings with suitable size GI clamps or laid in floors in the bldg of height upto G+15 complete all as specified and directed by Engineer-in-Charge for the following sizes:-
25 mm bore
20 mm bore
15 mm bore
Supply and fixing in repair gun metal gate valve, with iron wheel head, screwed both ends for GI pipe of following sizes (ISI Marked) fixed in existing line and in position complete all as specified and directed by Engineer-in-Charge
25 mm bore
20 mm bore
15 mm bore
Supply & fixing in repairs 15 mm bore angular stop valve cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union complete all as specified.
Supply & fixing in repairs low level PVC flushing cistern of heavy duty, 10 Ltrs capacity, syphonic action type complete with inlet, ball valve, float and handle including cast iron bracket and 32 mm bore PVC flush pipe and connecting to WC complete all as specified.
Supply and fixing in repair 450 mm long PVC connectors with brass adapters, washers etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair concealed stop valve CP fancy type ISI marked fixed to 15mm bore GI pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair stop valve CP fancy type ISI marked fixed to 15mm bore GI pipe complete all as specified and directed by Engineer-in-Charge.
Cleaning of raw water OHT tanks of capacity up to 5000 ltrs in existing position by mechanised pressure cleaned by Mechanical high pressure spray and steel wire brush to remove algae/dirt/foreign material completely and soaking out water/dirt with a high pressure wet vaccum pump and removing spoils outside of MD land and providing sticker showing the date of cleaning complete all as specified and directed by Engineer-in-Charge
Material and Labour for cleaning of GI pipes by opening of fittings, removing mud, sludge, etc and refixing the fittings as per existing for pipes of following size:- NOTE :For attending compaints contractor has to arrange one qualified Plumber with one Helper daily including Sunday & holiday to report at Complaint Cell for repair/ replacement of pipe line including plumbing works, attending complaints of leakage, air lock in pipe line etc and rates shall be included in Unit Rate quoted.
25 mm bore
20 mm bore
15 mm bore
Manning and Operation of raw water Meena Pump House consisting of electrically operated pump sets of different capcity at Meena Pump House ( for raw water) including Sundays and public holidays by one FGM- Skilled and one Mate FGM- Semi- skilled in each shift including taking care of pumps / valves/ overflow of tanks and other minor repairs and leakages daily in two shifts from 0600 to 1400 hours, 1400 to 2200 hours Each shift- 02 persons (1 FGM + 1 Mate FGM) The quoted rate per shift per month shall be for 1 FGM & 1 Mate FGM Combined Note- Log book shall be maintained by the contarctor duly signed and kept at installation .
Manning and Operation of raw water Meena Pump House consisting of electrically operated pump sets of different capcity at Meena Pump House ( for raw water) including Sundays and public holidays by one Mate FGM- Semi- Skilled in one shift including taking care of pumps / valves/ overflow of tanks and other minor repairs and leakages daily in one shift from 2200 to 0600 hours Each shift- 01 person ( 1 Mate FGM)
Manning and Operation of two R.O Plants in one shift with one FGM - Skilled from 0900 hrs to 1700 hrs including Sundays and holidays with cleaning and up keep of the installation operating the submersible pump installed in raw water bore well -02 Nos and operation of treated water pump set including taking care from any pilferage, theft or damage of RO plant etc complete all as specified and directed by Engineer-in-Charge. Notes :- (i) RO operator : 01 No (ii) RO Plants- 02 Nos. (iii) Quoted rate shall be deemed to be included for the both RO Plant and shall have out put of water capacity not less than 40,000 liters per day. (iv) The Quality of out put water shall confirm to IS 10500 of 1991 (As amended)
Notes for Item Nos 32.00 and 34.00 : The rate quoted shall be deemed to be included the following :- (i) The shift time shall be first shift 0600hrs to 1400hrs, second shift 1400hrs to 2200hrs & third shift 2200hrs to 0600hrs.. (ii) The contractor has to apply for entry pass, for the labours to be employed against the work, from Naval Police with valid documents and shall submit Police verification of labours after receipt of work order through GE (iii) Operator must be skilled & must have knowledge of operation & maintenance of RO plants, Pump Sets, DG Sets, Panel and controlling valves etc. (iv) Valve Man must be semi skilled & must have knowledge of controlling valves etc. (v) Consumable stores such as cotton waste, Grease including tools required shall be provided by the contractor. (vi) Operator must ensure cleanliness of Pump Sets/ DG Sets/ Panels and Pump house bldg. (vii) The rate quoted by the contractor shall be inclusive of Life insurance of all the tradesmen employed by him in case of untoward incident such as injuries, fracture or casualty while on duty. (viii) Checking of leakage /water level in the radiator,checking of leakage of oil from the engine,compressor etc, shall be carried out by the operator and noted in the register with signature of all concern.
(ix) Inform the JE/AGE E&M in charge of any electric faults, water supply failure, Diesel requirement for Gen Sets and any other mishappenings. (x) Any Major repair of Machineries, replacement of batteries and filing of Diesel for Gen Set will be carried out by the MES. (xi) Any other work not specifically mentioned above but ordered by the Engineer-in-Charge for the smooth functioning of Pump House for supply of water will have to be carried out without any extra cost. Rates quoted shall be deemed to be included accordingly (xii) Rate quoted shall be inclusive for Relief Staff to the persons employed in shifts. (xiii) After issue of work order, contractor has to submit the list of employees including reliver alongwith relevant documents as mentioned is PS to the Engineer-in-Charge. (xiv) Payment to employees shall be done by Aadhaar linked bank account only and it shall not be less than minimum fair wages as per act in vogue. The contractor shall submit proof of payment slip to Engineer-in-Charge before claiming any payment. (xv) Contractor has to submit proof of payment of EPF/ESI subscription made by him alongwith RAR failing which RAR will not be progressed for payment. (xvi) The rates quoted by the contractor shall be deemed to be included provision of all latest labour laws / regulations including all relevant taxes as applicable. (xvii) Contractor shall quote the rates considering their monthly leaves, releiver etc as per labour laws and nothing extra shall be paid on account of the above. In case of absence of staff/tradesman from duty, payment of that shift will not be paid. In addition to that a penalty of Rs 700/- per shift per person will be recovered from contractors dues. Also in case of long absence (more than one week) of staff/tradesman, the penalty shall be recovered including Sundays & Holidays if any. The contractor shall have no claim on this account. Reliver will be provided by the contractor in the quoted rate.
(xviii) If the quoted amount is less than the estimated cost given at SCH A Note at Page No 14 the lowest bidder will have to depost FDR/BGB as elaborated herein after in favour of Accepting Officer within 07 days of opening of financial bid (cover No 2). (xix) The deposited amount shall be the difference between estimated cost given at SCH A Note at Page No 14 and amount quoted by lowest bidder for respective item. FDR/BGB shall be released only after satisfactory completion of work. If the contractor fails to pay minimum wages to employees, the department shall have right to with hold the said amount which will beverified by GE. The decision of Accepting Officer regarding amont to be withheld shall be final and binding. The withheld amount will be utilised by GE for payment to employees if contractor fails to pay minimum wages and balance amount if any shall only be released. If the lowest bidder fails to deposit the amount as stated above within 07 days, the contractor shall be banned for 06 months & his bid shall be rejected. The contractor shall submit 03 Nos of BGNs/FDRs of equal amount as mentioned above. The BGBs/FDRs validity shall be 04 months, 08 month & 12 months respectively for the purpose of encashment release as the case may be. (xx) The rates quoted shall be inclusive of suitable reliver wherever sundays & holidays are mentioned for working.
Routine maintenance of RO plants No. 1 & 2 installed at Vandana and Vishakha complex having out put capacity of drinking water not less than 40,000 ltrs / day, maintenance of chlorine dosing system,coagulant dosing system,antiscalant dosing system carrying out the routine maintenance recommended by the manufacturer for daily, weekly, monthly and quarterly including repairs/ replacement of parts such as bearings, repairs of pumps, filters, welding of cracked/ broken any mild steel items/ foundation, PVC pipes and their fittings, LT panel boards etc complete all as specified & directed by Engineer-in-Charge including testing of treated water in the approved laboratory for bacteriological test and potability test for every month. Notes :- (a) Chemicals required for operation of RO plant will be measured and paid seperately under Schedule 'A' Part - III (b) RO Plant shall be maintained for smooth functioning and for out put capacity of drinking water not less than 40,000 liters / per day.
Removing surplus soil to a distance outside MoD land complete all as specified and directed. Note: The place of disposal shall be find out by the contractor.
Supply & fixing in repairs Reverse Osmosis membrane for RO plant of cap 40000 LPD as per existing type and make complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs induction motor of 1.5 HP Capacity, 3 phase, 2860 rpm, 50 HZ, 415 Volts,Head range 35-50 meter complete to match the existing and connecting up with existing control / electric system including all accessories and testing after completion complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs control panel for RO plant of capacity 40000 ltr per day complete to match the existing and connecting up with existing control / electric system including all accessories and testing after completion complete all as specified and directed by Engineer-in-Charge.
Supply and demonstration of chlorine residual test kit portable range upto 6 PPM with enclosure & orthodin solution bottle 500 ml capacity complete all as spificied and directed.
Material and labour for overhauling of submersible motor of capacity 2 to 3 HP installed at Vandana and Vishakha complex and including replacement of minor spare parts complete all as specified and directed by Engineer-in-Charge.
Material and labour for taking out submersible motor of capacity 2 to 3 HP from bore well and rewinding the same with existing size using super enameled copper winding, varnishing and heating up at desired temperature to achieve the Ohm resistance as per manufacturers instructions and connected in existing position after reapair and testing after completion complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs cartridge filter of RO plant complete to match the existing and connecting up with exisiting system including all accessories complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repairs 80 mm dia foot valve CI body ISI marked with flange / thread type as per site requirment conforming to IS 4038 complete all as specified and directed by Engineer- in- charge
Supplying and fixing 32mm bore CPVC pipes SDR 11 including Plain CPVC SDR 11 fittings as required laid in floors or fixed to walls and ceilings with suitable size GI clamps including taking down old CPVC pipe and fittings complete all as specified.
Supplying and fixing 40mm bore CPVC pipes SDR 11 including Plain CPVC SDR 11 fittings as required laid in floors or fixed to walls and ceilings with suitable size GI clamps including taking down old CPVC pipe and fittings complete all as specified.
Supply and fixing in repair PVC sheathed submersible copper conductor cable of size 2.5 sqmm 3 Core complete all as specifed and directed by Engr in Charge.
Supply and fixing in repairs sand core in Filter vessel of RO plant complete to match the existing and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs carbon media for water softner in FRP Filter of RO plant complete as per existing make suitable for existing RO and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge.
Supply only Antiscalant chemical for RO Plant as per existing make suitable for existing RO complete all as specified and directed by Engineer-in-Charge.
Supply only cleaning Chemical for RO Plant as per existing make suitable for existing RO complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs multiple valve of RO plant as per existing make suitable for existing RO and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge.
Supply only Calcium Hypochlorite in granular form in 45 Kg drum, having minimum 70% of available chlorine Ca(OCI)2 with anti-corrosive and anti-scaling properties suitable for human consumption. Note: Contractor shall produce test certificate & original purchase voucher from manufacturer alongwith RAR/FB.
Supply and fixing in repairs FRP Housing of membrane for supporting and balanceing existing membrane of RO plant of capacity 40000 LPD complete to match the existing and connecting up with existing system including all accessories complete all as specified and directed by Engineer-in-Charge.
Material & labour for draining out water from Semi under ground RCC sump of cap 01 lakh ltrs, scraping out bottom, top and sides of wall with wire brush to remove scaling, fungus and bleaching powder, flushing thoroughly with clean water and applying two coats of white wash, cleaning external surfaces of RCC sump and applying one coat of cement base paint and writing tank capacity, date of cleaning and due date of cleaning in capital letters of 20mm size on external surface of wall with white enamel paint over black paint surface complete all as directed by Engr-in-Charge
Supply & fixing in repairs dosing Pump high pressure single head gear motored adjustable with all accessories including lead tubing, connecting nuts, injection check valve, clay weight, ferules etc complete all as specified and directed.
Supply, install, testing and commissioning of indoor type, floor mounted,double door, factory fabricated,CPRI approved LT panel board of suitable size made out of 2 mm thick CRCA sheet mounted on MS angle 45mm x 45mm x 6mm thick , well ventilated, dust and vermin proof, cubical type with individual compartments for enclosures, with necessary arrangement for top entry of incoming and outgoing cables suitable for operation on 3 phase 50 Hz, 415 Volts and panel board should be front opening including locking arrangement complete including internal wiring with 1100 volts grade single core PVC insulated copper conductor FRLSH cables of suitable current carrying capacity and making good all connection of incoming and outgoing cables by using suitable size copper lugs including 600 Amps rated aluminium bus bar with RYB & N PVC sleeves wrapped on it duly powder coated of approved colour mounted on PCC 1:2:4 type B1 foundation of approved size including dismantling existing LT panel board after disconnecting all connections carefully and making good disturbed surfaces as per existing complete all as specified and with following accessories (a) ON load change over switch 400 Amps -01 No (b) MCCB four pole, 415 Volts, 50 HZ, 400 Amp with Ics = 100% Icu -01 No. (c) MCCB 3 pole, 415 Volts, 50 HZ, 100 Amp with Ics = 100% Icu -02 Nos. (d) MCCB 3 pole, 415 Volts, 50 HZ, 63 Amp with Ics = 100% Icu -08 Nos (e) DOL starter suitable for 3 HP submersible pump - 02 Nos (f) Star Delta starter suitable for 10 HP centrifugal pump set - 04 Nos (g) Phase indicator lamp complete with copper control wiring and suiable size of CT.
Supply, install, testing and comminssioning of indoor type, floor mounted,double door, factory fabricated,CPRI approved LT panel board of suitable size made out of 2 mm thick CRCA sheet mounted on MS angle 45mm x 45mm x 6mm thick , well ventilated, dust and vermin proof, cubical type with individual compartments for enclosures, with necessary arrangement for top entry of incoming and outgoing cables suitable for operation on 3 phase 50 Hz, 415 Volts and panel board should be front opening including locking arrangement complete including internal wiring with 1100 volts grade single core PVC insulated copper conductor FRLSH cables of suitable current carrying capacity and making good all connection of incoming and outgoing cables by using suitable size copper lugs including 600 Amps rated aluminium bus bar with RYB & N PVC sleeves wrapped on it duly powder coated of approved colour mounted on PCC 1:2:4 type B1 foundation of approved size including dismantling existing LT panel board after disconnecting all connections carefully and making good disturbed surfaces as per existing complete all as specified and with following accessories (a) MCCB 3 pole, 415 Volts, 50 HZ, 100 Amp with Ics = 100% Icu -01 No. (b) MCCB 3 pole, 415 Volts, 50 HZ, 63 Amp with Ics = 100% Icu -01 No. (c) Isolator 63 Amp, C curve, 4 pole -02 Nos. (d) Isolator 32 Amp, C curve, 4 pole -04 Nos. (e) DP 32 Amp, C curve -01 No. (f) DOL starter suitable for 3 HP submersible pump - 02 Nos (g) Phase indicator lamp complete with copper control wiring and suiable size of CT.
Supply and fixing in repairs 80mm bore CI butterfly valve ISI marked complete all as specified and directed by Engr in Charge.
Supply and fixing in repairs 50mm bore CI butterfly valve ISI marked complete all as specified and directed by Engr in Charge.
Supply and fixing in repairs ON load changeover switch of 315 Amp 415 Volts, 4 pole ISI marked alongwith enclosure complete all as specified and directed by Engr in Charge.
Supply and fixing in repairs carbon filter vessel polyethylene material, volume 450 Ltrs, pressure 10 bar suitable for RO plant of capacity 40000 LPD complete all as specified and directed by Engr in Charge.
Supply and fixing in repairs sand filter vessel polyethylene material, volume 450 Ltrs, pressure 10 bar suitable for RO plant of capacity 40000 LPD complete all as specified and directed by Engr in Charge.
Material and labour for rewinding the electric motor of capacituy 7.5HP to 10 HP capacity, disconnecting the electic connection of motor, earth connections, decoupling motor and pump, removing foundation nuts/bolts and removing the motor from its existing position to authorised workshop of OEM including the following :- (a) Removing the split case/body cover of motor, seperate stator/rptar and cutting the complete burnt/defective copper winding. (b) Cleaning the stator body complete by rubbing and removal all carbons. (c) Insert insulating materials such as insulating paper , sleeves etc. (d) Rewinding the stator with existing size of super enameled copper winding, varnishing and heaating up at desired temperature for achieve the particular Ohm resistance. (e) Clean the rotor and assembling in motor. (f) Connecting/coupling the motor with pump, connect all electric/earth connection foundation nuts.bolts at its original position and testing on load complete all as specified and directed.
Supply and Fixing in repairs dosing system tank consisting of 40 ltr-100 ltr PE/FRP with PE/FRP Lid & level gauge along with agitator with shaft & blade in plastic tank complete all as specified and directed by Engr in Charge.
Material & labour for taking out existing pump set, dismantling the rusted foundation bed of the motor and pump set, and fabrication of the foundation beds with MS channels, angle as per existing size suitable for pump set of capacity 5 HP to 10 HP and duly applying one coat of red oxide primer and two coats of bitumen paint of approved quality and errction the pump and motor including providing nut, bolts, washers etc and testing to the entire satisfaction of Engineer-in-Charge. Note:- The quoted rate shall deemed to be included for welding work, nuts, bolts, washer and MS fasteners including PCC 1:2:4 type B1 required for foundation as directed by Engineer-in-Charge.
Supply and fixing in repair bronze impeller suitable for 60/75 HP pump all as per manufacturer's design as per staging and eye of the impeller complete all as per specified and directed.
Supply and fixing in repair bronze impeller suitable for 40 HP pump all as per manufacturer's design as per staging and eye of the impeller complete all as per specified and directed.
Supply and fixing repair bronze impeller suitable for 10 HP pump all as per manufacturer's design as per staging and eye of the impeller complete all as per specified and directed.
Material & labour for in repair maintenance free chemical earthing of environment friendly earth electrod set comprising of 17.2 mm dia , 3 m long rod low carbon steel molecular copper bounded for a thickness of 250 micro Omhs highly conductive ANS/INSF STD -60 certified carbon bound backfill compound which shall set like concrete accordingly to BS 7430 & IEEE 80 each bag shall contain 50 ibs complete ass as specified and directed.
Supply & fixing in repairs MCCB,4Pole, 400 Amps, 25kA, 415Volts,50Hz AC supply complete all as specified and directed by Engr-in-charge.
Supply & fixing in repairs MCCB 4Pole, 200 Amps, 25kA, 415Volts,50Hz AC supply complete all as specified and directed by Engr-in-charge.
Supply & fixing in repairs MCCB 4Pole, 160 Amps, 25kA, 415Volts,50Hz AC supply complete all as specified and directed by Engr-in-charge.
Disconnecting the electric connections form starter and taking out burnt submersible water sensor from the existing position and supply and fixing new water sensor starter 3 phase suitable for 3 HP submersible pump complete all as specified and directed by Engr in Charge.
Shree Ayyappa Engineering (BID ID -3150786)
shubham construction (BID ID -3148837)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .