Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAdmitted-Finance | ₹12.8 L | L1 | Admitted-Finance |
| 2 | L2₹13.0 L+₹21,720 (1.70%)Admitted-Finance | ₹13.0 L+₹21,720 (1.70%) | L2 | Admitted-Finance |
| 3 | L3₹13.4 L+₹58,740 (4.60%)Admitted-Finance RAM KALA MANDIR GALI K K ELECTRICALS COURT ROAD UDHAMPUR RAMNAGAR CHOWK UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹13.4 L+₹58,740 (4.60%) | L3 | Admitted-Finance |
| 4 | L4₹14.5 L+₹1.7 L (13.5%)Admitted-Finance JAMMU KASHMIR HORTICULTURAL PRODUCE MARKETING PROCESSING CORPORATION JKHPMC LTD HORTICULTURE DEPARTMENT JAMMU KASHMIR GOVERNMENT OPPOSITE PRESENTATION CONVENT SCHOOL RAJBAGH J K190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | ₹14.5 L+₹1.7 L (13.5%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S SHAH ELECTRICAL ENGINEERS AND CO L2 | AKIB AHMAD L4 | M/S K.K ELECTRICALS L3 | M/S RATHER CONSTRUCTIONS AND TRADERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00Creation of 250 KVA sub-station at Arbal Banihal with HT/LT network. | |||||||
| 1.01 | 250 kVA (11/0.433-0.250KV;50Hz), Copper Wound
Distribution Transformer of latest Energy Efficiency
Level-2 (New), IS1180 Part-I; 2014 as per latest upto date
amendment with externally fitted MCCB with cable box and 4x4 Mtrs. suitable cable of ratings | 1 | No | 6,67,000 ₹6,67,000 | 8,10,000 ₹8,10,000 | 6,00,000 ₹6,00,000 Lowest | 6,50,000 ₹6,50,000 |
| 1.02 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer
housing, Stn. Type | 1 | Set | 3,500 ₹3,500 Lowest | 6,500 ₹6,500 | 4,500 ₹4,500 | 8,000 ₹8,000 |
| 1.03 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical | 1 | Set | 10,500 ₹10,500 | 12,000 ₹12,000 | 11,000 ₹11,000 | 10,000 ₹10,000 Lowest |
| 1.04 | 11 kV Horn Gap Fuse Set 3 Phase 200A | 1 | Set | 4,700 ₹4,700 | 7,000 ₹7,000 | 4,500 ₹4,500 Lowest | 5,000 ₹5,000 |
| 1.05 | 300 mm² (1ckt.) 1.1 kv Grade, PVC insulated stranded conductor FRLS type | 44 | mtr | 850 ₹37,400 | 400 ₹17,600 Lowest | 600 ₹26,400 | 400 ₹17,600 Lowest |
| 1.06 | 9 Mtr. Long Pole( ST-410 SP33) for sub station | 2 | No | 20,500 ₹41,000 | 19,500 ₹39,000 | 19,000 ₹38,000 | 17,500 ₹35,000 Lowest |
| 1.07 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and
80kV Negative, creepage distance 320mm | 3 | No | 750 ₹2,250 | 500 ₹1,500 | 300 ₹900 Lowest | 600 ₹1,800 |
| 1.08 | GI Channel/Angle/Flat of sizes including clamps | 300 | Kg | 110 ₹33,000 Lowest | 110 ₹33,000 Lowest | 120 ₹36,000 | 140 ₹42,000 |
| 1.09 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. | 3 | No | 1,050 ₹3,150 Lowest | 6,500 ₹19,500 | 2,200 ₹6,600 | 3,000 ₹9,000 |
Tender Value
Refer Docs
EMD Value
₹39,800
Closing Date
30 Jun 2026, 2:00 pmClosed
Executive Engineer JPDCL Batote
Oo Executive Engineer JPDCL Batote
Supply Survey Erection Testing and Commissioning for Creation of 250 KVA Substation at Arbal Banihal for deep drilling bore well pump room electro mechanical equipment sump tank delivery tank pipe network and water filling station under ED JPDCL Bato
2026_PDD_313273_1
eNIT 18 of 2026-27
Open Tender
Electrical Works
Turn-key
15 days
Batote
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Yes
Executive Engineer JPDCL Batote
₹39,800
Yes
11 Jul 2026
23 Jun 2026
1 Jul 2026
23 Jun 2026
30 Jun 2026
23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Creation of 250 KVA sub-station at Arbal Banihal with HT/LT network. | |||||
| 1.01 | 250 kVA (11/0.433-0.250KV;50Hz), Copper Wound
Distribution Transformer of latest Energy Efficiency
Level-2 (New), IS1180 Part-I; 2014 as per latest upto date
amendment with externally fitted MCCB with cable box and 4x4 Mtrs. suitable cable of ratings | 1 | No | - | - |
| 1.02 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer
housing, Stn. Type | 1 | Set | - | - |
| 1.03 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical | 1 | Set | - | - |
| 1.04 | 11 kV Horn Gap Fuse Set 3 Phase 200A | 1 | Set | - | - |
| 1.05 | 300 mm² (1ckt.) 1.1 kv Grade, PVC insulated stranded conductor FRLS type | 44 | mtr | - | - |
| 1.06 | 9 Mtr. Long Pole( ST-410 SP33) for sub station | 2 | No | - | - |
| 1.07 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and
80kV Negative, creepage distance 320mm | 3 | No | - | - |
| 1.08 | GI Channel/Angle/Flat of sizes including clamps | 300 | Kg | - | - |
| 1.09 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. | 3 | No | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
SBD12.pdf
Tender Documents • 0.71 MB
BOQ_1013776.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .