Executive Engineer JPDCL Batote
Oo Executive Engineer JPDCL Batote
Supply Survey Erection Testing and Commissioning for Creation of 250 KVA Substation at Arbal Banihal for deep drilling bore well pump room electro mechanical equipment sump tank delivery tank pipe network and water filling station under ED JPDCL Bato
2026_PDD_313273_1
eNIT 18 of 2026-27
Open Tender
Electrical Works
15 days
Batote
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Yes
Executive Engineer JPDCL Batote
₹39,800
Yes
23 Jun 2026
23 Jun 2026
1 Jul 2026
23 Jun 2026
30 Jun 2026
23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Creation of 250 KVA sub-station at Arbal Banihal with HT/LT network. | |||||
| 1.01 | 250 kVA (11/0.433-0.250KV;50Hz), Copper Wound
Distribution Transformer of latest Energy Efficiency
Level-2 (New), IS1180 Part-I; 2014 as per latest upto date
amendment with externally fitted MCCB with cable box and 4x4 Mtrs. suitable cable of ratings | 1 | No | - | - |
| 1.02 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer
housing, Stn. Type | 1 | Set | - | - |
| 1.03 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical | 1 | Set | - | - |
| 1.04 | 11 kV Horn Gap Fuse Set 3 Phase 200A | 1 | Set | - | - |
| 1.05 | 300 mm² (1ckt.) 1.1 kv Grade, PVC insulated stranded conductor FRLS type | 44 | mtr | - | - |
| 1.06 | 9 Mtr. Long Pole( ST-410 SP33) for sub station | 2 | No | - | - |
| 1.07 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and
80kV Negative, creepage distance 320mm | 3 | No | - | - |
| 1.08 | GI Channel/Angle/Flat of sizes including clamps | 300 | Kg | - | - |
| 1.09 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. | 3 | No | - | - |