Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 38 MUTHI MUTHI MUTHI JAMMU JAMMU KASHMIR 181205 | JAMMU | JAMMU AND KASHMIR | 181205 | Admitted-Finance |
Tender Value
₹6.0 L
Closing Date
28 Apr 2023, 4:30 pmClosed
Executive Engineer
Office of the Executive Engineer Mechanical Division Kathua
Installation, Testing and commissioning of 250 KVA DG SET for supplying power backup to 50 bedded (Pre-fabricated Structure)Hospital along with Construction of Tin shed over 250 KVA DG set and along with chain link fencing and other allied works
2023_PWDJK_209804_1
MDK/Tech/e-NIT/ 2023-24/01
Open Tender
Electrical and Maintenance Works
Lump-sum
60 days
GMC Kathua
As per e-NIT
2 documents required · 2 mandatory
₹200
Executive Engineer Mechanical Division Kathua
Exempted
11 May 2023
13 Apr 2023
29 Apr 2023
13 Apr 2023
28 Apr 2023
13 Apr 2023
Shifting of 250 KVA DG Set with the help of Hydra machine from ground level to place it on new constructed RCC foundation
Supplying, laying, jointing ,testing and commissioning 1100 volts grade LT XLPE insulated PVC sheathed as per IS-7098 (part 1), 1988 with latest amendments, galvanized steel strips or wire armored ,heavy duty electric cables with multi stranded aluminum conductors laid in trenches /passing through pipe/duct/road crossing or fixed on poles walls with suitable size clamps made out of mild steel flat iron including jointing materials such as crimping type lugs made out of mild steel iron including jointing materials such as crimping type lugs brass cable glands heavy duty double compression type etc. for making connection from 1. Electric substation / LT Pole to incomer bus of main power supply of AMF Panel of DG set. From panel to AMF Panel of DG set 2. AMF Panel of DG set to Distribution Control Panel already installed. 3. AMF Panel of DG set to DG set , 3.5 core armound 400 sq.mm.
Providing and laying of 4 core armouned cu cable of 4 sq.mm. from Automatic main failure panel of DG set to 250 KVA DG set
Earthing : The G.I plate earthing (Neutral Grounding )shall be provided with copper strip. the body earthing should be generally be of GI . Gi earth plate of 600 mm x 6mm thick including accessories providing masonry enclose with cover plate having locking arrangement and watering pipe etc. with complete as required. Earth pith up to 3m in depth and suitable width. Chemical for using earth electrode. Providing and fixing of 32x6 mm cu strip in .40 mm size medium class GI pipe from earth electrode in ground Four number of earthing are required:- 2 earthing sets for genset /control panel body 2 set earthing sets for neutral .
Cost of running DG set for 8 hour test run @25ltr/hr for testing purpose.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .