| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹41.3 L+₹1.3 L (3.33%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹43.5 L+₹3.5 L (8.84%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹45.3 L+₹5.3 L (13.2%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Documents asked in shortfall not submitted |
Tender Value
₹43.6 L
EMD Value
₹87,300
Closing Date
31 Jan 2023, 6:00 pmClosed
CWE Mathura
HQ CWE Mathura
As per tender documents
2022_MES_570759_2
CWE/MTR/E / 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (East) Mathura
As per NIT
7 documents required · 7 mandatory
₹500
GE (East) Mathura
₹87,300
Yes
25 Mar 2023
9 Jan 2023
7 Feb 2023
9 Jan 2023
31 Jan 2023
17 Jan 2023
Amount
Design, Supply, install, testing, connecting, charging and commissioning of solar PV modules to meet cumulative rated capacity of 70 KW.+/- 10% as per suitabilty with quantity , Modules will be of mono Crystalline type silicon modules with minimum 72 cells and rating of 335 Wp to 540Wp with positive tolerance, with minimum 1100 mm (+) & (-) cable length including with end MC4 connectors. Module efficiency of not less that 17.0% fill factor >0.7, module will be PID resistant, module connector suitable for MC4/Bizlink and juntion box with minimum, IP 67 rating. Module NOCT (Nominal operating cell temperature) will be 45±3° with temperature coefficient of power ˂0.4%/°C, and will be suitable for operation from - 20° to + 60°C ambient temperature. Modules will be combined to make array & string of panels to maximize power output along with supply and installation of necessary accessories like fuses, array/string junction box etc, Modules will be certified for relevant dust standards (Applicable standard would be IEC 60068-2-68). Modules shall be deployed with RF id tag inside lamination as per MNRE guidelines. Modules shall be certified as per IEC 61215- Edition -ll, IEC 61646 and IEC 61730-1 & 2 ISO 9001: 2008 Quality Management System, ISO 14001 : 2004 :Environmental management system or equivalent and other applicable IEC/IS standards.
NOTES :- (i) Each PV module & solar cells should be manufactured indigenously i.e. Indian made & should be BIS approved & IEC certified. The bidder shall produce all the certificate from manufacturer. The contractor shall procure & install module and cells of the same Indian manufacturer, the department reserve the right to inspect the manufacturing facility of OEM during the process of manufacturing of cells and modules. (ii) Solar Module Glass should have with anti reflective coating, excellent performance in low light, torsion and corrosion resistant with anodized aluminum frame. (iii) Solar PV modules shall have manufacturer’s warranty against all manufacturing defect, raw material, workmanship, inspection and testing etc. for a period of minimum 10 years from the date of commissioning. After successful commissioning of Solar Power plant the guaranteed electrical generation of power should not be less than the 90% after ten years of period and should not be less than 80% after 25 years of period of the output watt capacity of solar plant i.e. 70 KW.
(iv) Each PV module must use a RF identification tag (RFID), which must contain following information : (a) Name of the manufacturer of PV modules & Solar cells. (Indigenously made). (b) Month and year of the manufacture (Separately for solar cell and modules). (c) Country of origin (Separately for solar cell and module). (ALMM). (d) I-V curve for the module. (e) Peak Wattage, Im, Vm and FF for the module, also Unique serial no and Model No of the module. (f) Date and year of obtaining IEC PV module qualification certificate. (g) Name of the test lab issuing IEC certificate. (h) Other relevant information on traceability of solar cells and modules as per BIS approved specification.
Design, Supply, fixing and fabricate modules mounting structure (for 70 KW Solar power Plant) structure member should be hot dipped galvanized mild steel or Pre GAL with coating not less than 85 microns on galvanised steel and electrolytically compatible channels, bracing, purlins , electromagnetic washers, nuts, bolts including cutting, drilling etc. The design should be as per IS code and suitable for the wind speed as per Wind Zone of plant location. The design life should be more than 25 years and grade of steel should be YST310. Properties of RHS will conform to IS 4923 : 2017. HDG Fasteners of 4.6 grade and 8.8 grade for structure. The module mounting structure should be suitable for easy removing and refixing / replacing of PV modules of the Solar Plant. All MMS, foundation & fixing arrangement shall be according to the design and drawings approved from Accepting Officer. MMS installation work and associated work complete as per the approved design & drawings. complete all as specified and directed.
NOTES:- (i) Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, Its fasteners, nuts and bolts. Necessary protection towards rusting needs to be provided either by coating or anodization. (ii) MMS design & foundation design should be as per relevant IS code and shall be supported with design and shall be submitted for the approval of the Accepting Officer. (iii) The MMS structures and steel shall be as per latest IS 2062:2011 and galvanization of the mounting structure shall be in compliance of latest IS 4759. (iv) The fasteners used should be made of stainless steel of grade SS316. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from the SPV panels. (v) The PV array structure design shall be appropriate with a factor of safety of min. 1. (vi) Regarding civil structures the bidder needs to take care of the load bearing capacity of the roof and need to arrange suitable structures based on the quality of roof.
(vii) The structures should be fixed on roof top as per manufacturer's design with use of M-20 concrete mixture, water proofing shall be provided in the area where MMS is fixed on roof slab. (viii) The total load of the structure (when installed with PV modules) on the terrace should be less than 60 kg/m2. The load shall be well distributed so that point loads are well within the limits. (ix) The minimum clearance of the structure from the roof level should be sufficient to allow ventilation for cooling, also ease of cleaning and maintenance of panels as well as cleaning of the terrace. (x) Warranty of MMS shall be of 10 years and Service life 25 Years. Any defect arising with in 24 Months the defective part of the structure shall be replaced by the contractor at his own cost.
Supply and laying cable in trenches or fixed on structure on wall floor ceiling etc of power control cables single core double insulated solar cable with fine copper wire multistranded, single core 6 Sqmm FLX-SOL-XL type, Tuv certified according to latest regulations -40°C to +120°C (permanent) UV, ozone and hydrolysis-resistant including all accessories and fixing arrangement complete all as specified and as directed. Make: Polycab,finolex, Havells
Design, Supply, install, testing, connecting and commissioning of solar DC DB box comprising as per string design to meet cumulative rated capacity of 70 KW Solar module string complete with fuses, connector, SPD, isolator in polycarbonate box IP65 and suitable for outdoor installation with fixing arrangements complete all as specified and directed.
Design, Supply, install, testing, connecting and commissioning Grid connected String type solar inverters of 70KW , microprocessor based , inbuilt wifi connectivity to monitoring data and Inverter shall be capable of synchronisation with grid supply complete with all controll wiring and suitable for outdoor installation with fixing arrangement and having following specifications :- (i) Ambient temp : 4° C to 60° C (ii) Relative humidity : 0-100 % non-condensing (iii) Environmental condition : outdoor, wet location (iv) Protection degree : IP-65 (v) Pollution degree : IV (vi) Safety class : class I metal enclosure (vii) MPP Tracker 2MPP trackers (viii) No. of inputs minimum 12 Nos MC4 or as per String design (ix) Frequency rated : 50 Hz (x) Total Harmonic distortion shall be less than 3% (xi) Power factor shall be more than 90% at any load (xii) Inverter Efficiency >93% (In case of 10 KW or above with inbuilt galvanic isolation) >97% (In case of 10 KW or above without inbuilt galvanic isolation) >90% (In case of less than10 KW) (xiii) External communication: RS-485 Port (xiv) Grid frequency Tolerance range +3 or more (xv) No load losses less than 1% (xvi) Protection against DG set run & grid isolation with synchronisation Make (DELTA, STRUDER, Schnider, ABB, Goodwe,sungrow )
INPUT (DC) : M50A Max recommended PV module - 70kWp, Max input voltage-1500 Volts, DC voltage range -200-1500 Volts and as suitable Start-up voltage >250 Volts, Start-up power -40 Watt, MPPT voltage range -200-1500 Volts, MPP voltage range full power -520-800 Volts, Nominal DC voltage -600 Volts, Max input current (total MPPT 1 /MPPT 2)- 100 Amp (50 Amp/50 Amp), Max short circuit current total (MPPT 1/MPPT 2)-120 Amp (60 Amp/60 Amp), Nos of Independent MPP tracker -2 Nos, Nos of DC input -12 or as per String design , Max asymmetry -60/40% : 40/60% Input connection type - Multi connect MC4, DC connect switch -Yes (inbuilt)
Output (AC) : (i) MPPT of inverter not less than 70 kW ( capacity of inverter) with associated control and protection devices integrated to convert DC Power into 3 Phase AC voltage, along with grid synchronizing facility - voltages 415 Volt AC, 3 Phase 50 Hz, Peak Effficiency > 98%, THD < 3% , Temp range -10°C to +55°C power factor Control range > 0.95 lead or lag including all measuring meters complete - 01 Set (ii) Protection switchgear based with overlead, short circuit, earth fault and instantaneous over current digital metering system. NOTE : The Inverter (PCU) shall be warranted for minimum 5 years against all material / manufacturing defects and workmanship after date of completion of work.
S&F Cable Connectors (MC4 male & female) 1500V (IEC/CEI), 600V (UL), With safety clip that requires a tool to unlock (NEC2008 compliant) Certified for applications with modules according to IEC 61730, Safety class II, Directive 2002 / 95 / EC on the restriction of the use of certain hazardous substances in electrical and electronic equipment - with Minimal voltage drop, High current-carrying capacity, Minimal power loss, Minimal contact resistance, High durability contacts withstand up to 1 million mating cycles, Operating temperatures up to 350°C, higher temperatures permitted for short periods complete all as specified and as directed.
S&F nominal 3.0 mm + 10% thick insulating mats made of elastomer conforming to IS-15652: 2006 and meeting the requirement of IS- 5216 (Part -1 & 2) IS 8437, IEC-479 Pub -1 along with suitable adhesive / homebound, PV resin water proofing compound and sealing material as per recommendation of Annex 'A’, Clause- 'C’ of IS- 15652 and suitable for class - C upto 33 kV complete all as specified and as directed.
M&L lightening arresters ESE (Eearly streamer emission) type with 4 metres and accordance with NFC 17-102 2011 and suitable for all types of lightning discharges (negative, positive or lateral), neeeding no external power source and protection radius not less than 80mtere including all mounting and fixing arrangement and chemical copper earthing with copper Strip 32 x 6 mm upto test point and 25 x 3 mm copper strip test point to Lightning Arrester with suitable porcelaine insulator complete all as specified & directed.
Supply and laying flexible DWC HDPE pipe ISI UV resistant in trenches under floor, wall etc 32 mm inner dia and 40mm outer dia including necessary fixing clamp complete all as specified and directed.
M&L for earthing of machinery/equipment/ Panel etc. complete with galvanized steel earth plate electrode size 600 mm x 600 mm x 6 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 32 x 6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40mm dia connected to main earth lead on pole or control board and GI pipe medium grade 20 mm dia for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion complete all as specified & directed. Note : GI strip & protection pipe beyond 7.5 Mtr length from earth electrode shall be measured and paid separately
S & F earth continuity conductor or main earthing lead of 25 mm X 3.15 mm aluminium strip fixed to wall on batten or recess or chases or buried in ground including with drawn in conduit /pipe or fixed to poles , walls or any other indicated situation for loop earthing including with use porcelain insulator etc. as required complete all as specified and as directed.
S & F earth continuity conductor or main earthing lead of 32 mm X 6 mm galvanised mild steel strip fixed to wall on batten or recess or chases or buried in ground including with drawn in conduit /pipe or fixed to poles , walls or any other indicated situation for loop earthing including with use porcelain insulator etc. as required complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 95 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under road / floors/ wall with use of suitable fixing clamps and passing through HDPE DWC pipe complete all as specified and as directed. Make of cable : Havells / Gloster / Polycab Note : HDPE DWC Pipe shall be measured & paid separetly under relevent item
Supply and install of 100W LED flood light with 230 V AC outdoor type, IP-66 degree of proction,corrosion resistant, with luminaire efficiecy of greater than 80Lumen/Watt. The luminaire should have 5 KV surg protection, PF ≥ 0.9 ,voltage range of 140-280V should be provided. Over voltage proction should be there after 300 V +/- 10%, Luminaire should have top maintanable driver compartment for easy access to driver during maintenance, including suitable clamp with nut & bolts aditional as per directed in fixing of pole/roof top /wall with all connections complete all as specified and directed. Make of fitting : Crompton Greaves/ Bajaj/Philips/ Havells
Excavation in trenches in any type of soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables/GI pipe and getting out complete all as specified and as directed.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables/ GI pipe have been laid and tested complete all as specified and as directed.
M&L for HDPE Double Wall Corrugated pipe of size 63mm outer dia and 50mm inner dia confirming to IS:14930 Part-II including necessary pipe fittings such as couplers, end caps, bend etc. laid in trenches/ fixed to wall with suitable clamps for cable protection complete all as specified and directed. Make : Gemini/Stiple or equivalent
Supply and fixing of PVC insulated round sheathed (flexible) industrial cable weather proof three core copper conductor cable of size 6 Sqmm for connections of motor / flood light including heavy duty PVC conduit pipe with suitable fixing arrangement complete all as specified and as directed.
Supply and fixing self priming 1 HP Monoblock Pump Set incl DOL Starter, Single Phase 240V ,1500 RPM,delivery size 25mm and head upto 40mtr, discharge range 3000-800 ltrs/hour complete with connecting & testing including fixing of suitable sheet canopy for protection of motor from raining complete all as specified and as directed.
Supply & fixing for hose reel drum with 20mm dia rubber hose pipe 30 mtr long ISI marked IS 444 hose reel with mounting glove valve 20 mm including adjustable gun nozzle complete all as specified and as directed.
M & L Plain Cement Concrete 1:2:4 type B1 using 20mm graded stone aggregate as in foundations of motor, filling mass concrete including rendering 10mm thick on fair faces concrete surfaces in Cement Mortar (CM) 1:6 with finished even and smooth without using extra cement complete all as specified and directed.
Supply,install,testing and commissioning of CPRI approved factory made LT Outdoor Type Panel box ,floor mounted , single phase 200amp and having sheet steel enclosure powder coated CRCA sheet double door (outer shell thickness 3.15mm and inner shell thickness 2mm and having legs 60cm made out of 50x50x6mm angle iron), front openable door with locking arrangement and including foundation 1:2:4 type B1 and including necessary incoming and out going cable connection with proper size aluminium lugs, nut bolts, glands etc and comprising of the following switch gears:- (i) MCB 20 Amp, DP 10KA rating -01 No (incommer) (ii) MCB 10 Amp, SP 10KA rating -02 No (Outgoing) (iii) DOL Pump Starter Single Phase for 1 HP Motor - 01 Nos (iv) Digital universal meter with LED display for 1-ph Amp, Volt, Frequency and P.F Cl 0.5 Make- L&T (Cat Part No WL411021OOOO) (v) Complete Panel wiring with LED type AC 220 Volt Phase Indicator
M&L for steel water tubes of 25mm dia, medium grade, galvanised, with all fittings , laid in trenches /roof /fixed in wall with suitable clamping and connecting with existing lines with suitable GI Tee including testing complete all as specified and directed.
M&L for steel water tubes of 15mm dia, medium grade, galvanised, with all fittings , laid in trenches /roof /fixed in wall with suitable clamping including testing complete all as specified and directed.
M&L for Gun Metal gate valve with iron wheel head, screwed both ends for iron pipe of size 25mm dia complete all as specified and directed.
M&L for Gun Metal gate valve with iron wheel head, screwed both ends for iron pipe of size 15mm dia complete all as specified and directed.
Supply & fix Rotational moulded polythylene water storeage tanks (for storage of cold water & cleaning of collector) of capacity 2000 ltrs, ISI marked (cylinderical vertical with closed top ) triple layer hoisted and fixed in position complete all as specified and directed in SSR Part-I .
S & F Ball brass valve high pressure with polythene float and flynut complete screwed from iron pipe or brass ferrule and fixed of size 25mm complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode size 600 mm x 600 mm x 6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth lead on pole or control board and GI pipe light grade 20 mm dia for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion complete all as specified & directed. Note : GI wire and protection pipe upto 7.5 Mtr length from earth electrode shall be included in quoted rate of item.
M & L for GI Pipe light grade 40mm bore for earth strip protection in floor/road crossing/along pole complete all as specified and as directed.
M & L for GI Pipe light grade 15mm bore for earth wire protection in ground/floor/hard standing/along pole complete all as specified and as directed.
M&L for GI GI wire 4mm dia as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle .
Phase - II (Item No.35)
Comprehensive maintenance of complete 70 KW solar power plant and its related civil & E/M works by deploying trained personal for carrying out maintenance & task given below :- (a) Weekly Task :- (i) Cleanig of PV modules / tightening of nut / bolt, checking of all electrical connections etc minimum once in a week or as per manufacturers instructions and or as directed by Engr-in-Charge / GE to make a solar plant fully functional. (ii) Daily maintain a log sheet for recording of total generated readings of solar plant, grid shutdown details as directed by Engr-in-Charge / GE and submit once in a week to Engr in Charge. (b) Periodical inspection of plant once in a month by Engineer of the solar firm installing the plant to ensure maximum output of plant. (c) The thermal imaging of PV panel should be taken once in a year for checking its health incluidng hot spots. (d) The shutdown duration of plant should be monitered, recorded and analysised. (e) All fire safety and fire fighting measures shall be ensured by the contractor during the comprehensive maintenance period irrerpective of provisions available. Note :-(i) Repair / replacement of defective parts / civil repair works of any part / work executed in Part I will be carried out by the contractor as per defect liability and guarntee / warranty clause and nothing extra will be paid for the same. (ii) All stationary / registers, T&P, minor items reqd to maintain the installations 100% functionable condition provided by the contractor and cost shall be included in quoted rate of item.
Sunskrity Energy Pvt Ltd
Ms Kamal Kant Agarwal
SOLARIUM GREEN ENERGY PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .