Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST L1 | |
| 2 | L2₹28.6 L+₹14,870 (0.52%)Rejected-Finance H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹30.0 L+₹1.5 L (5.18%)Rejected-Finance | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹31.6 L+₹3.1 L (11.0%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest | |
| 5 | L5₹34.4 L+₹5.9 L (20.6%)Rejected-Finance | L5 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
20 Mar 2024, 6:00 pmClosed
GE Jaipur
GE Jaipur
REPAIR / MAINT OF INTERNAL ELECTRIFICATION WORK IN MH AREA AND ZONE - II (B) AREA UNDER AGE E/M OF GE JAIPUR
2024_MES_643576_1
GE/J-70/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE Jaipur
As per Tender Documents
5 documents required · 5 mandatory
₹500
GE Jaipur
₹84,000
Yes
8 May 2024
22 Feb 2024
22 Mar 2024
22 Feb 2024
20 Mar 2024
7 Mar 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings/fixing accessories and unwelded sunken galvanised pressed steel terminal modular boxes of thickness not less than 1.0 mm covered with modular cover plates for mounting modular switches, scokets, fan regulators as required for one light point controlled by one switch complete all as specified and directed.
All as per item No. 02 above but for one fan point controlled by one switch complete all as specified and directed.
All as per item No. 02 above but for one light point controlled by two, two way switch complete all as specified and directed.
All as per item No. 02 above but for socket outlet 6 Amps controlled by one switch on the same board with other swithces complete all as specified and directed.
All as per item No. 02 above but socket outlet 6 Amps controlled by one switch on independent board complete all as specified and directed.
All as per item No. 02 above but one bell point controlled by one bell push complete all as specified and directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 2.5 Sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings/fixing accessories and unwelded sunken galvanised pressed steel terminal modular boxes of thickness not less than 1.0 mm covered with modular cover plates for mounting modular switches, sockets as required for one 16 Amps socket outlet point controlled by one switch on independent board complete all as specified and directed.
M&L for point wiring with 1100 volts grade PVC insulatd FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) drawn into and including PVC casing-capping not less than 32x16 mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators etc for one light point controlled by one switch complete all as specified and directed.
All as per item No. 09 above but one fan point controlled by one switch complete all as specified and directed.
All as per item No. 09 above but one light point controlled by two, two way switch complete all as specified and directed.
All as per item No. 09 above but one socket outlet 6 Amps controled by one switch on the same board with other switches complete all as specified and directed.
All as per item No. 09 above but one socket outlet 6 Amps controlled by one switch on independent board complete all as specified and directed.
All as per item No. 09 above but one bell point controlled by one bell push complete all as specified and directed.
M&L for point wiring with 1100 volts grade PVC insulatd FRLS multistranded copper conductor cable 2.5 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 2.5 Sqmm (Green) drawn into and including PVC casing-capping not less than 32x16mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0mm covered with 3mm thick phenolic laminated white sheet cover for mounting switches, sockets etc for one 16 Amps socket outlet point controlled by one switch on independent board complete all as specified and directed.
S&F angle holder, insulated polycarbonate body with back plate complete all as specified and directed.
S&F switch piano flush button single pole one way 6 Amp complete all as specified and directed.
S&F switch piano flush button single pole one way 16 Amp complete complete all as specified and directed.
S&F switch piano flush button single pole two way 6 Amp complete all as specified and directed.
S&F bell push, flush type, 6 Amps 240 volts complete complete all as specified and directed.
S&F socket outlet, 2-in-1, 3 pin 6 & 16 Amps combined flush type compete complete all as specified and directed.
S&F socket outlet, 2-in-1, 3 pin 6 Amps flush type compete complete all as specified and directed.
S&F hum free electronic step fan regulator 120-280 volts of 100 watts capacity (socket type) including connecting up complete all as specified and directed.
S&F in repair switch piano flush button single pole one way 6 Amp complete all as specified and directed.
S&F in repair switch piano flush button single pole one way 16 Amp complete all as specified and directed.
S&F in repair switch piano flush button single pole two way 6 Amp complete all as specified and directed.
S&F in repair switch bell push flush type 6 Amp complete all as specified and directed.
S&F in repair socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type complete all as specified and directed.
S&F in repair socket outlet, 2-in-1, 3 pin 6 Amps flush type complete all as specified and directed.
S&F in repair hum free electronic step fan regulator 120-280 volts of 100 watts capacity (socket type) including connecting up complete all as specified and directed.
S&F door bell AC 240 volts, buzzer/ding dong single pole complete all as specified and directed.
S&F ceiling rose 3 plates polycarbonate body complete all as specified and directed.
S&F switch modular 1 way 6 Amps, 230 volts, 1 module complete all as specified and directed.
S&F modular socket 6 Amps, 2/3 pin combined 2 module AC 230 volts complete all as specified and directed.
S&F modular switch 1 way 16 Amps, 230 volts, 1 module complete all as specified and directed.
S&F modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts complete all as specified and directed.
S&F modular fan regulator 120 watts, 2-module AC 230 Volts complete all as specified and directed.
S&F modular switch, 6 Amp, two way, 1 module AC 230 volts complete all as specified and directed.
S&F in repair switch modular 1 way 6 Amps, 230 volts, 1 module as per existing make and size complete all as specified and directed.
S&F in repair modular socket 6 Amps, 2/3 pin combined 2 module AC 230 volts. as per existing make and size complete all as specified and directed.
S&F in repair modular switch 1 way 16 Amps, 230 volts, 1 module as per existing make and size complete all as specified and directed.
S&F in repair modular fan regulator 120 watts, 2-module AC 230 Volts step type as per existing make and size complete all as specified and directed.
S&F in repair modular switch 2 way 10 Amps, 230 volts, 1 module as per existing make and size complete all as specified and directed.
S&F in repair modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts as per existing make and size complete all as specified and directed.
S&F in repair door bell AC 240 volts, buzzer/ding dong single pole complete all as specified and directed.
Supply and fixing in replacement ceiling fan 1200mm sweep 50 Hz AC 230 votls, 5 star rated in white colour with BLDC fan motor, blade set, 0.45 mtr down rod, canopy set, rubber reel including 0.5 Sqmm three core PVC insulated flexible copper conductor multistranded wire from fan motor to ceiling and writing MES No. on fan body as required complete all as specified and directed.
S&F wire less door bell AC 230 volts, single pole all as specified and directed.
S&F LED lamp 9W, 230V edison screw type, energy saver, white warm / crystal white light complete all as specified and directed by the Engineer-in-Charge
S&F LED lamp 11W, 230V edison screw type, energy saver, white warm / crystal white light complete all as specified and directed by the Engineer-in-Charge
Supply only insulation electrical tape PVC self adhesive type with colour coding of size (18mmX8mtr) superior quality for day to day maintenece make: Anchor/Steelgrip/ or eqvt all as specified.
Taking down carefully sub main wiring with PVC casing capping / PVC surface conduit and making good disturbed surfaces complete all as specified and directed.
M&L for sub main wiring with two run of 4 Sqmm single core, PVC insulated, FRLS multistranded copper conductor cable alongwith one run of 4.0 Sqmm earth wire as earth continuity conductor (Phase-Red, Neutral-Black, Earth-Green) drawing into and including concealed PVC conduit of 20mm dia ISI marked ivory colour & accessories of suitable size including making connection as required complete all as specified and directed. NOTE - Two run of 4 sq.mm phase and neutral wire & One run of 4 sq.mm earth wire & One run of PVC conduit with accessories shall be measured as One length.
All as per item No. 52 above but two run of 6 Sqmm and one run of 6 Sqmm earth in 20 mm dia PVC conduit complete all as specified and directed.
All as per item No. 52 above but two run of 10 Sqmm and one run of 10 Sqmm earth in 25mm dia PVC conduit complete all as specified and directed.
Taking down MCB distribution board with incoming and outgoing controls any make and capacity after disconnecting complete all as specified and directed.
S&F MCBs Distribution board tripple pole and neutral (VTPN) 4 ways, powder coated, CRCA steel sheet, suitable for MCCB incomer upto 160amp, degree of protection IP-43, IK09 with reversible double door, 415V, recess mounted having insulated 200 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
S&F MCBs Distribution board SPN, 4 ways, powder coated, CRCA steel sheet, degree of protection IP-43, IK-09 with reversible double door, 415V, recess mounted having insulated 100 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
S&F MCBs Distribution board SPN, 8 ways, powder coated, CRCA steel sheet, degree of protection IP-43, IK-09 with reversible double door, 415V, recess mounted having insulated 100 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
S&F MCBs Distribution board SPN, 12 ways, powder coated, CRCA steel sheet, degree of protection IP-43, IK-09 with reversible double door, 415V, recess mounted having insulated 100 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
S&F MCBs Distribution board TPN, 4 ways, powder coated, CRCA steel sheet, degree of protection IP-43, IK-09 with reversible double door, 415V, recess mounted having insulated 100 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
S&F in repair MCBs of 'C' series single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
S&F in repair MCBs of 'C' series SPN 10 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
S&F in repair MCBs of 'C' series SPN 40 to 63 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
S&F in repair MCBs of 'C' series four pole 63 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.
S&F in repair MCCB four pole, 415 volt, adjustable type, 63amp with breaking capacity 16KA, thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB including reqd cable connections with copper lugs of suitable size and testing & commisioning and make goodcomplete all as specified and directed.
S&F in repair MCCB four pole, 415 volt, adjustable type, 125 amp with breaking capacity 16KA, thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB including reqd cable connections with copper lugs of suitable size and testing & commisioning and make goodcomplete all as specified and directed.
S&F LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete all as specified and directed. Make - Philips Cat part BN308C LED20S-6500 L120 PSU WH, Crompton Cat part CIS-305-40-57-SL-DP-NWH, Havells Cat no STOUTPLUS600BS20WLED840SPCWH.
S&F in repair LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficiency of 115 lumen per watt and total power consumption not more than 18/20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a colour temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete all as specified and directed. Make - Philips Cat part BN308C LED20S-6500 L120 PSU WH, Crompton Cat part CIS-305-40-57-SL-DP-NWH, Havells Cat no STOUTPLUS600BS20WLED840SPCWH.
Supply and fixing in replacing old FTL light with energy efficient recessed mounted LED luminaire suitable for 2'x2' grid ceiling with fullglow fully diffused diffuser and lumen output of 3600 lumens having constant current electronic driver of 36 watt duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable as required.
S&F in repair LED batten fitting (0.6mtr long) made CRCA sheet housing with a PC glossy diffuser duly prewired connection having a normal system lumen output of 900 lumens at a minimum system efficiency of 100 lumens per watt at a total power consumption not more than 9 watts (including LED driver) having colour temperature 6500K, CRI>80, THD<10% and PF >0.95, Long Life including making connection complete all as specified and directed.
S&F in repair LED bulk head light fitting 9/10 watt IP 66 & IK 09 with polycarbonate body with LED driver duly prewired connection with 0.75sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable complete all as specified & directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6.0mm buried directly in ground, vertically to depth not less than 2.25mtr below normal ground level with top edge of the earth plate at depth not less than 1.5 metre below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI lead wire 4.0mm dia by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe medium grade 20mm bore for watering, 40mm bore GI pipe medium grade for protection of GI wire upto test point including providing funnel and wire mesh GI frame and 10cm thick suitably reinforced RCC pit cover, PCC chamber pit with PCC (1:3:6) type C2 using 40mm graded stone aggregates complete including excavation and earth work in any type of strata, disposal of surplus soil to a distance not exceeding 50 mtr, all as specified ans shown in Electrical plate No. 3 of SSR Part-1, PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit including testing on completion complete. (Note - GI lead wire size 4.0mm upto 7.5 m included in the item).
S&F in repair 20 amp, single pole and neutral, socket outlet, with 2 pole and earth, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 20 amp as required as per approved complete all as specified & directed.
S&F in repair air ventalation fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, 1200 RPM, Copper winding of sweep 200mm complete all as specified & directed.
S&F in repair air ventalation fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified & directed.
S&F in repair air ventalation fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm complete all as specified & directed.
Supply and fixing in repair PVC insulated alluminium service cable of 10 Sqmm twin core cable with fixing arrangement incl necessary clamp, nut, bolt & washers etc.fixed at wall / ceiling/ laid under floor complete all as specified & directed.
M&L for fixing / repairing loose and disconnected point wiring or diverting the route of point wiring upto a length not exceeding 2.0 metre including required cable of same size and carrier (PVC casing caping or conduit, domestic gang box etc) with fasteners etc and making good disturbed surfaces even and smooth using CM (1:3) as required complete all as specified & directed.
Material and Labour for taking out old buzzer system including panel from wall and repairing buzzer system with replacing indicating light and push switch as required or all connected items or as directed
S&F high efficiency post top lantern LED type 15 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F greenline high efficiency LED light luminaire 35 watt complete with driver, pressure die cast aluminium housing, UV stablized polycarbonates cover, inbuilt power unit, IP-65 protection including mounting bracket made of 25mm GI pipe, medium grade ISI marked not less than 1.2m, bend in shape, fix with 02 no clamps, nut, bolt and washers as reqd complete all as specified & directed.
S&F in repair of AC film capacitor 2.5 mfd, 440 volts suitable for any type ceiling fan in FR plastic casing including connection complete all as specified and directed.
S&F in repairs high efficiency LED diriver for LED luminaare 2X2 panel grid ceiling of capacity 36 watt any make and model as reqd on site complete all as specified and directed.
S&F in repair LED flood light 100 watt, lumen output 3000K, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F bollard LED garden light 8 watt 1 Mtr hight with aluminium housing, glare free PMMA difuser, IP-65 complete with required earth work, including fasteners, nuts, bolts, washers, copper connecting cable & PCC (1:2:4) type B 1 using 20 mm graded stone aggregate (size 0.40 m x 0.30 m x 0.45 m) complete all as directed.
S & F in repair plastic surface boxes 3 module for fixing modular switch and socket complete all as specified and directed.
S & F in repair plastic surface boxes 4 module for fixing modular switch and socket complete all as specified and directed.
S & F in repair plastic surface boxes 6 module for fixing modular switch and socket complete all as specified and directed.
S & F in repair plastic surface boxes 8 module for fixing modular switch and socket complete all as specified and directed.
Supply and fixing DLP Plastic trunking 105 mm & 50 mm size for cable tray riser to DB and DB to sub DB for sub main wiring including all connected accessories i.e. flexible cover, adjustable internal/ external angle, clip, cover joint, base joint etc reqd for fixing and making good to disturbed wall surfaces complete all as directed by the EIC. Make : Legrand, Finolex, Supreme or equivalent as approved by GE.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
PARADISE INFRA POWER COMPANY
Shree Karni Electrovision
M/s Prakash Enterprises
LAKSHMI ASSOCIATES
Gaurav & company
Bluemax Associate
M/S Sheeba Enterprises
SHREE BHAGWATI ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .